Search results

1 – 10 of 890
Article
Publication date: 14 January 2022

Xiang Li, Keyi Wang, Yan Lin Wang and Kui Cheng Wang

Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture…

Abstract

Purpose

Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture plays a critical role for rehabilitation, footwear design, clinical diagnostics and sports activities, and so on. This paper aims to review plantar force measurement technologies based on piezoelectric materials, which can make the reader understand preliminary works systematically and provide convenience for researchers to further study.

Design/methodology/approach

The review introduces working principle of piezoelectric sensor, structures and hardware design of plantar force measurement systems based on piezoelectric materials. The structures of sensors in plantar force measurement systems can be divided into four kinds, including monolayered sensor, multilayered sensor, tri-axial sensor and other sensor. The previous studies about plantar force measurement system based on piezoelectric technology are reviewed in detail, and their characteristics and performances are compared.

Findings

A good deal of measurement technologies have been studied by researchers to detect and analyze the plantar force. Among these measurement technologies, taking advantage of easy fabrication and high sensitivity, piezoelectric sensor is an ideal candidate sensing element. However, the number and arrangement of the sensors will influence the characteristics and performances of plantar force measurement systems. Therefore, it is necessary to further study plantar force measurement system for better performances.

Originality/value

So far, many plantar force measurement systems have been proposed, and several reviews already introduced plantar force measurement systems in the aspect of types of pressure sensors, experimental setups for foot pressure measurement analysis and the technologies used in plantar shear stress measurements. However, this paper reviews plantar force measurement systems based on piezoelectric materials. The structures of piezoelectric sensors in the measurement systems are discussed. Hardware design applied to measurement system is summarized. Moreover, the main point of further study is presented in this paper.

Article
Publication date: 26 April 2023

Yucheng Shi, Deren Kong and Xuejiao Ma

The purpose of this study is to clarify the mechanism of ambient and transient temperature effects on piezoelectric pressure sensors, and to propose corresponding compensation…

Abstract

Purpose

The purpose of this study is to clarify the mechanism of ambient and transient temperature effects on piezoelectric pressure sensors, and to propose corresponding compensation measures. The temperature of the explosion field has a significant influence on the piezoelectric sensor used to measure the shock wave pressure. For accurate shock wave pressure measurement, based on the actual piezoelectric pressure sensors used in the explosion field, the effects of ambient and transient temperatures on the sensor should be studied.

Design/methodology/approach

The compensation method of the ambient temperature is discussed according to the sensor size and material. The theoretical analysis method of the transient temperature is proposed. For the transient temperature conduction problem of the sensor, the finite element simulation method of structure-temperature coupling is used to solve the temperature distribution of the sensor and the change in the contact force on the quartz crystal surface under the step and triangle temperatures. The simulation results are highly consistent with the theory.

Findings

Based on the analysis results, a transient temperature control method is proposed, in which 0.5 mm thick lubricating silicone grease is applied to the sensor diaphragm, and 0.2 mm thick fiberglass cloth is wrapped around the sensor side. Simulation experiments are carried out to verify the feasibility of the control method, and the results show that the control method effectively suppresses the output of the thermal parasitic.

Originality/value

The above thermal protection methods can effectively improve the measurement accuracy of shock wave pressure and provide technical support for the evaluation of the power of explosion damage.

Details

Sensor Review, vol. 43 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 1 February 1992

B. Morten, G. De Cicco, A. Gandolfi and C. Tonelli

A study has been carried out on the relationship between the composition, poling condition and piezoelectric properties of thick film layers. Pastes based on…

Abstract

A study has been carried out on the relationship between the composition, poling condition and piezoelectric properties of thick film layers. Pastes based on lead‐titanate‐zirconate (PZT) powders, with either PbO or a lead‐alumina‐silicate glass frit as binder, were prepared. Microstructure, electrical and mechanical properties were analysed. Processing and poling conditions modify these properties; then a wide latitude of opportunities is offered in the choice of ferroelectric/piezoelectric characteristics of the layers used as sensing elements for sensors. A pressure sensor was realised where a circular diaphragm of alumina supports two piezoelectric layers obtained by screen printing and firing a PZT/PbO‐based ferroelectric paste. The design and the performance characteristics are described.

Details

Microelectronics International, vol. 9 no. 2
Type: Research Article
ISSN: 1356-5362

Article
Publication date: 12 December 2017

Yu Tian, Jun Zhang, Zongjin Ren, Wei Liu, Zhenyuan Jia and Qingbing Chang

This paper aims to improve calibration and force measurement accuracy of multi-sensorspiezoelectric dynamometer used in thrust measurement of rocket/air vehicle engine.

Abstract

Purpose

This paper aims to improve calibration and force measurement accuracy of multi-sensorspiezoelectric dynamometer used in thrust measurement of rocket/air vehicle engine.

Design/methodology/approach

This paper presents a mapping solution method of sensors’ outputs based on the Kirchhoff thin plate theory, builds force-deformation differential equations with specific boundary conditions, uses finite difference (FD) method to solve the equations and analyzes outputs in offset loading forces in four-sensor square layout in main direction. The resultant force deviations calculated by the Kirchhoff theory are optimized with sequence quadratic program (SQP) method, and a calibration method of multiple loading points (MLP) based on the Kirchhoff theory is presented. Experiments of static calibration and verification are complemented to contrast the novel and single loading point (SLP) calibration method.

Findings

Experiments of static calibration and its verification show that at a loading force of 5,000N, the average resultant force deviations with MLP is 17.87N (0.35% FS) compared with single loading point method 26.45N (0.53% FS), improving calibration and measurement precision.

Originality value

A novel calibration method with MLP is presented. Force distributions of multiple sensors of main direction in piezoelectric dynamometer with offset loading force are solved with the Kirchhoff theory. The resultant force deviations calculated by Kirchhoff theory are optimized with the SQP method.

Article
Publication date: 23 December 2021

Ewa Klimiec, Piotr Zachariasz, Halina Kaczmarek, Bogusław Królikowski and Sławomir Mackiewicz

This paper aims to present the details of isotactic polypropylene (it-PP) films with a cellular structure (air-cavities) dedicated to pressure sensors. The polymer composites…

Abstract

Purpose

This paper aims to present the details of isotactic polypropylene (it-PP) films with a cellular structure (air-cavities) dedicated to pressure sensors. The polymer composites (thin films enriched with 5 and 10 wt% of mineral fillers as Sillikolloid P 87 and glass beads) should exhibit suitable structural elasticity within specific stress ranges. After the deformation force is removed, the sensor material must completely restore its original shape and size.

Design/methodology/approach

Estimating the stiffness tensor element (C33) for polymer films (nonpolar space-charge electrets) by broadband resonance ultrasound spectroscopy is a relatively simple method of determining the safe stress range generated in thin pressure sensors. Therefore, ultrasonic and piezoelectric studies were carried out on four composite it-PP films. First, the longitudinal velocity (vL) of ultrasonic waves passing through the it-PP film in the z-direction (thickness) was evaluated from the ω-position of mechanical resonance of the so-called insertion loss function. In turn, the d33 coefficient was calculated from accumulated piezoelectric charge density response to mechanical stress.

Findings

Research is at an early stage; however, it can be seen that the mechanical orientation of the it-PP film improves its piezoelectric properties. Moreover, the three-year electric charge stability of the it-PP film seems promising.

Originality/value

Ultrasonic spectroscopy can be successfully handled as a validation method in the small-lot production of polymer films with the air-cavities structure intended for pressure sensors. The structural repeatability of polymer films is strongly related to a homogeneous distribution of the electric charge on the electret surface.

Article
Publication date: 6 July 2015

Litesh N Sulbhewar and P. Raveendranath

Piezoelectric extension mode smart beams are vital part of modern control technology and their numerical analysis is an important step in the design process. Finite elements based…

Abstract

Purpose

Piezoelectric extension mode smart beams are vital part of modern control technology and their numerical analysis is an important step in the design process. Finite elements based on First-order Shear Deformation Theory (FSDT) are widely used for their structural analysis. The performance of the conventional FSDT-based two-noded piezoelectric beam formulations with assumed independent linear field interpolations is not impressive due to shear and material locking phenomena. The purpose of this paper is to develop an efficient locking-free FSDT piezoelectric beam element, while maintaining the same number of nodal degrees of freedom.

Design/methodology/approach

The governing equations are derived using a variational formulation to establish coupled polynomial field representation for the field variables. Shape functions based on these coupled polynomials are employed here. The proposed formulation eliminates all locking effects by accommodating strain and material couplings into the field interpolation, in a variationally consistent manner.

Findings

The present formulation shows improved convergence characteristics over the conventional formulations and proves to be the most efficient way to model extension mode piezoelectric smart beams, as demonstrated by the results obtained for numerical test problems.

Originality/value

To the best of the authors’ knowledge, no such FSDT-based finite element with coupled polynomial shape function exists in the literature, which incorporates electromechanical coupling along with bending-extension and bending-shear couplings at the field interpolation level itself. The proposed formulation proves to be the fastest converging FSDT-based extension mode smart beam formulation.

Details

Engineering Computations, vol. 32 no. 5
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 7 December 2015

Artur Szewieczek, Christian Willberg, Daniel Schmidt and Michael Sinapius

A design of sensor networks for structural health monitoring (SHM) with guided waves poses a hard challenge. Therefore different approaches are possible. A known one is the usage…

Abstract

Purpose

A design of sensor networks for structural health monitoring (SHM) with guided waves poses a hard challenge. Therefore different approaches are possible. A known one is the usage of probability of detection (POD) criteria. Here, areas of potential impact sensitivity are calculated for every sensor which leads to a POD. The number of sensors is increased until a demanded POD is reached. However, these calculations are usually based on finite element methods and underlie different assumptions and approximations which can cause different inaccuracies. These limitations are avoided by using an experimental data basis for virtual sensors in this paper. The paper aims to discuss these issues.

Design/methodology/approach

An air-coupled ultrasound scanning technique is used for guided wave investigations. Recorded displacements of a structure surface are used as stimulation of virtual sensors which can be designed by software and positioned within available data field. For the calculation of sensor signals an isogeometric finite element model is used. The virtually bonded layer of the virtual piezoceramic sensor interpolates with non-uniform rational B-Splines (NURBS) the measured nodal data for each time step. This interpolation corresponds to a displacement boundary condition and is used to calculate the electrical potential at the free surface of the sensor.

Findings

Experimental data based on air-coupled ultrasound scanning technique can be used for elimination of disadvantages in numerical simulations by developing sensor networks for SHM. In combination with a transfer matrix method (TM) a three-dimensional displacement of specimen surface for complex composites can be calculated. To obtain the sensor signal a surface-bonded sensor is modeled by an isogeometric finite element approach. A good accordance is found between calculated virtual sensor signal and its experimental verification.

Research limitations/implications

Some deviations between calculated signal and its experimental verification are mainly justified by different spectral transfer functions between wave field scanning technique and signal recording of applied sensors. Furthermore, sensor influence on wave propagation is neglected in the presented method.

Originality/value

In this paper, the principle of virtual sensors is applied on anisotropic multilayered lamina by using isogeometric finite elements for piezoelectric sensors. This enables any sensor dimension, layout and position on complex composites. Furthermore a bonding layer between specimen and sensor is considered. The method allows a detailed analysis of sensor behavior on a specimen surface and the design and optimization of entire sensor networks for SHM.

Details

International Journal of Structural Integrity, vol. 6 no. 6
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 December 2017

Shaoyi Xu, Fangfang Xing, Ruilin Wang, Wei Li, Yuqiao Wang and Xianghui Wang

At present, one of the key equipment in pillar industries is a large rotating machinery. Conducting regular health monitoring is important for ensuring safe operation of the large…

869

Abstract

Purpose

At present, one of the key equipment in pillar industries is a large rotating machinery. Conducting regular health monitoring is important for ensuring safe operation of the large rotating machinery. Because vibrations sensors play an important role in the workings of the rotating machinery, measuring its vibration signal is an important task in health monitoring. This paper aims to present these.

Design/methodology/approach

In this work, the contact vibration sensor and the non-contact vibration sensor have been discussed. These sensors consist of two types: the electric vibration sensor and the optical fiber vibration sensor. Their applications in the large rotating machinery for the purpose of health monitoring are summarized, and their advantages and disadvantages are also presented.

Findings

Compared with the electric vibration sensor, the optical fiber vibration sensor of large rotating machinery has unique advantages in health monitoring, such as provision of immunity against electromagnetic interference, requirement of less insulation and provision of long-distance signal transmission.

Originality/value

Both contact vibration sensor and non-contact vibration sensor have been discussed. Among them, the electric vibration sensor and the optical fiber vibration sensor are compared. Future research direction of the vibration sensors is presented.

Details

Sensor Review, vol. 38 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 6 September 2019

Andreas Diermeier, Dirk Sindersberger, Peter Angele, Richard Kujat and Gareth John Monkman

Ultrasound is a well-established technology in medical science, though many of the conventional measurement systems (hydrophones and radiation force balances [RFBs]) often lack…

Abstract

Purpose

Ultrasound is a well-established technology in medical science, though many of the conventional measurement systems (hydrophones and radiation force balances [RFBs]) often lack accuracy and tend to be expensive. This is a significant problem where sensors must be considered to be “disposable” because they inevitably come into contact with biological fluids and expense increases dramatically in cases where a large number of sensors in array form are required. This is inevitably the case where ultrasound is to be used for the in vitro growth stimulation of a large plurality of biological samples in tissue engineering. Traditionally only a single excitation frequency is used (typically 1.5 MHz), but future research demands a larger choice of wavelengths for which a single broadband measurement transducer is desirable. Furthermore, because of implementation conditions there can also be large discrepancies between measurements. The purpose of this paper deals with a very cost-effective alternative to expensive RFBs and hydrophones.

Design/methodology/approach

Utilization of cost-effective piezoelectric elements as broadband sensors.

Findings

Very effective results with equivalent (if not better) accuracy than expensive alternatives.

Originality/value

This paper concentrates on how very cost-effective piezoelectric ultrasound transducers can be implemented as sensors for ultrasound power measurements with accuracy as good, if not better than those achievable using radiation force balances or hydrophones.

Content available

Abstract

Details

Sensor Review, vol. 22 no. 4
Type: Research Article
ISSN: 0260-2288

Keywords

1 – 10 of 890