Xiang Li, Keyi Wang, Yan Lin Wang and Kui Cheng Wang

Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture…

Abstract

Purpose

Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture plays a critical role for rehabilitation, footwear design, clinical diagnostics and sports activities, and so on. This paper aims to review plantar force measurement technologies based on piezoelectric materials, which can make the reader understand preliminary works systematically and provide convenience for researchers to further study.

Design/methodology/approach

The review introduces working principle of piezoelectric sensor, structures and hardware design of plantar force measurement systems based on piezoelectric materials. The structures of sensors in plantar force measurement systems can be divided into four kinds, including monolayered sensor, multilayered sensor, tri-axial sensor and other sensor. The previous studies about plantar force measurement system based on piezoelectric technology are reviewed in detail, and their characteristics and performances are compared.

Findings

A good deal of measurement technologies have been studied by researchers to detect and analyze the plantar force. Among these measurement technologies, taking advantage of easy fabrication and high sensitivity, piezoelectric sensor is an ideal candidate sensing element. However, the number and arrangement of the sensors will influence the characteristics and performances of plantar force measurement systems. Therefore, it is necessary to further study plantar force measurement system for better performances.

Originality/value

So far, many plantar force measurement systems have been proposed, and several reviews already introduced plantar force measurement systems in the aspect of types of pressure sensors, experimental setups for foot pressure measurement analysis and the technologies used in plantar shear stress measurements. However, this paper reviews plantar force measurement systems based on piezoelectric materials. The structures of piezoelectric sensors in the measurement systems are discussed. Hardware design applied to measurement system is summarized. Moreover, the main point of further study is presented in this paper.

Article
Publication date: 30 October 2020

Gaoxin Cheng, Linsen Xu, Jiajun Xu, Jinfu Liu, Jia Shi, Shouqi Chen, Lei Liu, Xingcan Liang and Yang Liu

This paper aims to develop a robotic mirror therapy system for lower limb rehabilitation, which is applicable for different patients with individual movement disability levels.

Abstract

Purpose

This paper aims to develop a robotic mirror therapy system for lower limb rehabilitation, which is applicable for different patients with individual movement disability levels.

Design/methodology/approach

This paper puts forward a novel system that includes a four-degree-of-freedom sitting/lying lower limb rehabilitation robot and a wireless motion data acquisition system based on mirror therapy principle. The magnetorheological (MR) actuators are designed and manufactured, whose characteristics are detected theoretically and experimentally. The passive training control strategy is proposed, and the trajectory tracking experiments verify its feasibility. Also, the active training controller that is adapt to the human motor ability is designed and evaluated by the comparison experiments.

Findings

The MR actuators produce continuously variable and compliant torque for robotic joints by adjusting excitation current. The reference limb joint position data collected by the wireless motion data acquisition system can be used as the motion trajectory of the robot to drive the affected limb. The passive training strategy based on proportional-integral control proves to have great trajectory tracking performance through experiments. In the active training mode, by comparing the real-time parameters adjustment in two phases, it is certified that the proposed fuzzy-based regulated impedance controller can adjust assistance torque according to the motor ability of the affected limb.

Originality/value

The system developed in this paper fulfills the needs of robot-assisted mirror therapy for hemiplegic patients.

Details

Industrial Robot: the international journal of robotics research and application, vol. 48 no. 2
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 25 May 2022

Rameesh Lakshan Bulathsinghala, Serosha Mandika Wijeyaratne, Sandun Fernando, Thantirige Sanath Siroshana Jayawardana, Vishvanath Uthpala Indrajith Senadhipathi Mudiyanselage and Samith Lakshan Sunilsantha Kankanamalage

The purpose of this paper is to develop a prototype of a wearable medical device in the form of a bandage with a real-time data monitoring platform, which can be used domestically…

Abstract

Purpose

The purpose of this paper is to develop a prototype of a wearable medical device in the form of a bandage with a real-time data monitoring platform, which can be used domestically for diabetic patients to identify the possibility of foot ulceration at the early stage.

Design/methodology/approach

The prototype can measure blood volumetric change and temperature variation in the forefoot area simultaneously. The waveform extracted using a pulsatile-blood-flow signal was used to assess blood perfusion-related information, and hence, predict ischemic ulcers. The temperature difference between ulcerated and the reference was used to predict neuropathic ulcers. The medical device can be used as a bandage during the application wherein the sensory module is placed inside the hollow pocket of the bandage. A platform was developed through a mobile application where doctors can extract real-time information, and hence, determine the possibility of ulceration.

Findings

The height of the peaks in the pulsatile-blood-flow signal measured from the subject with foot ischemic ulcers is significantly less than that of the subject without ischemic ulcers. In the presence of ischemic ulcers, the captured waveform flattens. Therefore, the blood perfusion from arteries to the tissue of the forefoot is considerably low for the subject with ischemic ulcers. According to the temperature difference data measured over 25 consecutive days, the temperature difference of the subject with neuropathic ulcers occasionally exceeded the 4 °F range but mostly had higher values closer to the 4 °F range. However, the temperature difference of the subject who had no complications of neuropathic ulcers did not exceed the 4 °F range, and the majority of the measurements occupy a narrow range from −2°F to 2 °F.

Originality/value

The proposed prototype of wearable medical apparatus can monitor both temperature variation and pulsatile-blood-flow signal on the forefoot simultaneously and thereby predict both ischemic and neuropathic diabetes using a single device. Most importantly, the wearable medical device can be used domestically without clinical assistance with a real-time data monitoring platform to predict the possibility of ulceration and the course of action thereof.

Details

Research Journal of Textile and Apparel, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1560-6074

Keywords

Open Access
Article
Publication date: 28 August 2021

Luca Gabriele De Vivo Nicoloso, Joshua Pelz, Herb Barrack and Falko Kuester

There are over 40 million amputees globally with more than 185,000 Americans losing their limbs every year. For most of the world, prosthetic devices remain too expensive and…

2648

Abstract

Purpose

There are over 40 million amputees globally with more than 185,000 Americans losing their limbs every year. For most of the world, prosthetic devices remain too expensive and uncomfortable. This paper aims to outline advancements made by a multidisciplinary research group, interested in advancing the restoration of human motion through accessible lower limb prostheses.

Design/methodology/approach

Customization, comfort and functionality are the most important metrics reported by prosthetists and patients. The work of this paper presents the design and manufacturing of a custom made, cost-effective and functional three-dimensional (3D) printed transtibial prosthesis monocoque design. The design of the prosthesis integrates 3D imaging, modelling and optimization techniques coupled with additive manufacturing.

Findings

The successful fabrication of a functional monocoque prosthesis through 3D printing indicates the workflow may be a solution to the worldwide accessibility crisis. The digital workflow developed in this work offers great potential for providing prosthetic devices to rural communities, which lack access to skilled prosthetic physicians. The authors found that using the workflow together with 3D printing, this study can create custom monocoque prostheses (Figure 16). These prostheses are comfortable, functional and properly aligned. In comparison with traditional prosthetic devices, the authors slowered the average cost, weight and time of production by 95%, 55% and 95%, respectively.

Social implications

This novel digital design and manufacturing workflow has the potential to democratize and globally proliferate access to prosthetic devices, which restore the patient’s mobility, quality of life and health. LIMBER’s toolbox can reach places where proper prosthetic and orthotic care is not available. The digital workflow reduces the cost of making custom devices by an order of magnitude, enabling broader reach, faster access and improved comfort. This is particularly important for children who grow quickly and need new devices every few months or years, timely access is both physically and psychologically important.

Originality/value

In this manuscript, the authors show the application of digital design techniques for fabricating prosthetic devices. The proposed workflow implements several advantageous changes and, most importantly, digitally blends the three components of a transtibial prosthesis into a single, 3D printable monocoque device. The development of a novel unibody transtibial device that is properly aligned and adjusted digitally, greatly reduces the number of visits an amputee must make to a clinic to have a certified prosthetist adjust and modify their prosthesis. The authors believe this novel workflow has the potential to ease the worldwide accessibility crisis for prostheses.

Details

Rapid Prototyping Journal, vol. 27 no. 11
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 18 October 2018

Zuhao Li, Chenyu Wang, Chen Li, Zhonghan Wang, Fan Yang, He Liu, Yanguo Qin and Jincheng Wang

This paper aims to review the latest applications in terms of three-dimensional printed (3DP) metal implants in orthopedics, and, importantly, the design of 3DP metal implants…

574

Abstract

Purpose

This paper aims to review the latest applications in terms of three-dimensional printed (3DP) metal implants in orthopedics, and, importantly, the design of 3DP metal implants through a series of cases operated at The Second Hospital of Jilin University were presented.

Design/methodology/approach

This paper is available to practitioners who are use 3DP implants in orthopedics. This review began with the deficiency of traditional prostheses and basic concepts of 3DP implants. Then, representative 3DP clinical cases were summarized and compared, and the experiences using customized prostheses and directions for future potential development are also shown.

Findings

The results obtained from the follow-up of clinical applications of 3DP implants show that the 3D designed and printed metal implants could exhibit good bone defect matching, quick and safe joint functional rehabilitation as well as saving time in surgery, which achieved high patient satisfaction collectively.

Originality/value

Single center experiences of 3DP metal implants design were shared and the detailed technical points between various regions were compared and analyzed. In conclusion, the 3DP technology is infusive and will present huge potential to reform future orthopedic practice.

Details

Rapid Prototyping Journal, vol. 24 no. 8
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 11 July 2019

Yaser Javed, Mohtashim Mansoor and Irtiza Ali Shah

Pressure, being one of the key variables investigated in scientific and engineering research, requires critical and accurate measurement techniques. With the advancements in…

2091

Abstract

Purpose

Pressure, being one of the key variables investigated in scientific and engineering research, requires critical and accurate measurement techniques. With the advancements in materials and machining technologies, there is a large leap in the measurement techniques including the development of micro electromechanical systems (MEMS) sensors. These sensors are one to two orders smaller in magnitude than traditional sensors and combine electrical and mechanical components that are fabricated using integrated circuit batch-processing technologies. MEMS are finding enormous applications in many industrial fields ranging from medical to automotive, communication to electronics, chemical to aviation and many more with a potential market of billions of dollars. MEMS pressure sensors are now widely used devices owing to their intrinsic properties of small size, light weight, low cost, ease of batch fabrication and integration with an electronic circuit. This paper aims to identify and analyze the common pressure sensing techniques and discuss their uses and advantages. As per our understanding, usage of MEMS pressure sensors in the aerospace industry is quite limited due to cost constraints and indirect measurement approaches owing to the inability to locate sensors in harsh environments. The purpose of this study is to summarize the published literature for application of MEMS pressure sensors in the said field. Five broad application areas have been investigated including: propulsion/turbomachinery applications, turbulent flow diagnosis, experimentalaerodynamics, micro-flow control and unmanned aerial vehicle (UAV)/micro aerial vehicle (MAV) applications.

Design/methodology/approach

The first part of the paper deals with an introduction to MEMS pressure sensors and mathematical relations for its fabrication. The second part covers pressure sensing principles followed by the application of MEMS pressure sensors in five major fields of aerospace industry.

Findings

In this paper, various pressure sensing principles in MEMS and applications of MEMS technology in the aerospace industry have been reviewed. Five application fields have been investigated including: Propulsion/Turbomachinery applications, turbulent flow diagnosis, experimental aerodynamics, micro-flow control and UAV/MAV applications. Applications of MEMS sensors in the aerospace industry are quite limited due to requirements of very high accuracy, high reliability and harsh environment survivability. However, the potential for growth of this technology is foreseen due to inherent features of MEMS sensors’ being light weight, low cost, ease of batch fabrication and capability of integration with electric circuits. All these advantages are very relevant to the aerospace industry. This work is an endeavor to present a comprehensive review of such MEMS pressure sensors, which are used in the aerospace industry and have been reported in recent literature.

Originality/value

As per the author’s understanding, usage of MEMS pressure sensors in the aerospace industry is quite limited due to cost constraints and indirect measurement approaches owing to the inability to locate sensors in harsh environments. Present work is a prime effort in summarizing the published literature for application of MEMS pressure sensors in the said field. Five broad application areas have been investigated including: propulsion/turbomachinery applications, turbulent flow diagnosis, experimental aerodynamics, micro-flow control and UAV/MAV applications.

Details

Sensor Review, vol. 39 no. 5
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 12 March 2018

Harish Kumar Banga, Rajendra M. Belokar, Parveen Kalra and Rajesh Kumar

Ankle–foot orthoses (AFOs) are assistive devices prescribed for a number of physical and neurological disorders affecting the mobility of the lower limbs. Additive manufacturing…

1407

Abstract

Purpose

Ankle–foot orthoses (AFOs) are assistive devices prescribed for a number of physical and neurological disorders affecting the mobility of the lower limbs. Additive manufacturing has been explored as an alternative process; however, it has proved to be inefficient cost-wise. This work aims to explore the possibilities of generating modular AFO elements, namely, calf, shank and footplate, with the localized composite reinforcement that aids in the optimization of the device in terms of functionality, aesthetics, rigidity and cost.

Design/methodology/approach

The conventional lower leg–foot orthosis configuration depends on thermoforming a polymer sheet around a mortar cast with a trademark firmness relying upon the trim-line with the inalienable plan restrictions. In manufacturing of AFO the expert, i.e. orthotist's, guidance is used. Polypropylene and polyethylene material is used in fabrication of AFO to complete all-round reported points of interest over the ordinary outlines, yet their mechanical conduct under administration conditions cannot be effectively anticipated.

Findings

AFOs made of polypropylene and polyethylene material are available in the market, which are used by children of age 3-5 years. With the existing AFO design, patients are facing excessive heating and sweating problems during long-term usage. After feedback from patients and orthotists (who prescribed AFO to patients), an attempt has been made to solve the problem with a new and improved AFO design of AFO by using finite element modelling and stress analysis. Also, the results indicate that the new design is similar to the actual product design.

Originality/value

This work introduces the low-cost 3D printing with reinforcement approach as an alternative route for the designing and manufacturing of orthotic devices with complex shapes. It is expected that new applications add-up to increase the body of knowledge about the behaviour of such products which will mix both areas, composite theory and additive manufacturing. This study investigated the fields related to 3D scanning, 3D printing and computer-aided designing for the manufacturing of a customized AFO.

Details

Rapid Prototyping Journal, vol. 24 no. 2
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 1 September 2007

Jeremy Turk

The area of behavioural phenotype research and related clinical practice is now recognised as one of high relevance to all practitioners who help people with learning…

Abstract

The area of behavioural phenotype research and related clinical practice is now recognised as one of high relevance to all practitioners who help people with learning disabilities, whatever their age. Knowledge continues to accumulate rapidly regarding aspects pertaining to aetiology, likely developmental, emotional and behavioural challenges, useful multidisciplinary interventions and supports and long‐term prognosis. This paper reviews the concept, its history and recent developments, focusing on those aspects which are of particular importance to clinical and other care and support professionals and their clients. There is a continuing need for widespread dissemination of the large body of relevant information, and its application to practice in order to maximise benefits for people with learning disabilities and their families.

Details

Advances in Mental Health and Learning Disabilities, vol. 1 no. 3
Type: Research Article
ISSN: 1753-0180

Keywords

Article
Publication date: 27 July 2021

Shahnawaz Anwer, Heng Li, Maxwell Fordjour Antwi-Afari, Waleed Umer, Imran Mehmood and Arnold Yu Lok Wong

Since construction workers often need to carry various types of loads in their daily routine, they are at risk of sustaining musculoskeletal injuries. Additionally, carrying a…

Abstract

Purpose

Since construction workers often need to carry various types of loads in their daily routine, they are at risk of sustaining musculoskeletal injuries. Additionally, carrying a load during walking may disturb their walking balance and lead to fall injuries among construction workers. Different load carrying techniques may also cause different extents of physical exertion. Therefore, the purpose of this paper is to examine the effects of different load-carrying techniques on gait parameters, dynamic balance, and physiological parameters in asymptomatic individuals on both stable and unstable surfaces.

Design/methodology/approach

Fifteen asymptomatic male participants (mean age: 31.5 ± 2.6 years) walked along an 8-m walkway on flat and foam surfaces with and without a load thrice using three different techniques (e.g. load carriage on the head, on the dominant shoulder, and in both hands). Temporal gait parameters (e.g. gait speed, cadence, and double support time), gait symmetry (e.g. step time, stance time, and swing time symmetry), and dynamic balance parameters [e.g. anteroposterior and mediolateral center of pressure (CoP) displacement, and CoP velocity] were evaluated. Additionally, the heart rate (HR) and electrodermal activity (EDA) was assessed to estimate physiological parameters.

Findings

The gait speed was significantly higher when the load was carried in both hands compared to other techniques (Hand load, 1.02 ms vs Head load, 0.82 ms vs Shoulder load, 0.78 ms). Stride frequency was significantly decreased during load carrying on the head than the load in both hands (46.5 vs 51.7 strides/m). Step, stance, and swing time symmetry were significantly poorer during load carrying on the shoulder than the load in both hands (Step time symmetry ration, 1.10 vs 1.04; Stance time symmetry ratio, 1.11 vs 1.05; Swing time symmetry ratio, 1.11 vs 1.04). The anteroposterior (Shoulder load, 17.47 mm vs Head load, 21.10 mm vs Hand load, −5.10 mm) and mediolateral CoP displacements (Shoulder load, −0.57 mm vs Head load, −1.53 mm vs Hand load, −3.37 ms) significantly increased during load carrying on the shoulder or head compared to a load in both hands. The HR (Head load, 85.2 beats/m vs Shoulder load, 77.5 beats/m vs No load, 69.5 beats/m) and EDA (Hand load, 14.0 µS vs Head load, 14.3 µS vs Shoulder load, 14.1 µS vs No load, 9.0 µS) were significantly larger during load carrying than no load.

Research limitations/implications

The findings suggest that carrying loads in both hands yields better gait symmetry and dynamic balance than carrying loads on the dominant shoulder or head. Construction managers/instructors should recommend construction workers to carry loads in both hands to improve their gait symmetry and dynamic balance and to lower their risk of falls.

Practical implications

The potential changes in gait and balance parameters during various load carrying methods will aid the assessment of fall risk in construction workers during loaded walking. Wearable insole sensors that monitor gait and balance in real-time would enable safety managers to identify workers who are at risk of falling during load carriage due to various reasons (e.g. physical exertion, improper carrying techniques, fatigue). Such technology can also empower them to take the necessary steps to prevent falls.

Originality/value

This is the first study to use wearable insole sensors and a photoplethysmography device to assess the impacts of various load carrying approaches on gait parameters, dynamic balance, and physiological measures (i.e. HR and EDA) while walking on stable and unstable terrains.

Details

Engineering, Construction and Architectural Management, vol. 29 no. 9
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 8 November 2022

Amin Eidi

Detection of low-frequency pressures such as heart rate in the range of 1 Hz is one of the applications of low-frequency resonator. In this paper, the structure of the resonator…

Abstract

Purpose

Detection of low-frequency pressures such as heart rate in the range of 1 Hz is one of the applications of low-frequency resonator. In this paper, the structure of the resonator is in the form of a plate, whose mathematical model has been extracted according to past works and is reported.

Design/methodology/approach

This paper presents an electromechanical microresonator that can be used as an ultra-low-frequency pressure sensor. It is very important to choose the right material for the sensors to have the optimal conditions. In this work, by proposing the innovative use of polytetrafluoroethylene material with low stiffness coefficient, the necessary conditions are provided to reduce the vibration frequency of the resonator.

Findings

The proposed design is simulated with the help of COMSOL, and its results are compared with the results of the mathematical model, which are very close to each other. Therefore, by inferring the results, the authors can rely on accurate simulations and finalize the similar designs with full confidence before fabrication.

Originality/value

There are important advantages regarding the geometry of the proposed design structure that is the possibility of detecting a pressure of 1 Pa only with voltages less than 2 V. On the other hand, the pull-in effect causes very low frequencies to be achieved in detection with the help of the proposed resonator. Also, the linear and nonlinear behavior of the resonator by applying different pressures has been studied and reported to find the appropriate operating range of the resonator and its limitations.