Search results

1 – 10 of 28
Article
Publication date: 1 October 2018

Ehsan Bazarchi, Yousef Hosseinzadeh and Parinaz Panjebashi Aghdam

It is common practice in structural engineering to assume floor diaphragms infinitely stiff in their own plane. But, most of the code provisions lack clarity and unity in…

Abstract

Purpose

It is common practice in structural engineering to assume floor diaphragms infinitely stiff in their own plane. But, most of the code provisions lack clarity and unity in categorising floor diaphragms and discussing their behaviour based on the seismic response of the structures. Besides, although many of these code provisions have presented simple techniques and formulations for determining the level of flexibility in floor diaphragms, the implementation of these techniques on more complex floor systems such as the steel-deck composite floors is still under question. The paper aims to discuss these issues.

Design/methodology/approach

In this study, an equivalent concrete floor is employed as a representative of in-plane diaphragm action of steel-deck composite floor, using simple modelling techniques in SAP2000 and the results are validated by complex structural models developed in ABAQUS. Afterwards, the equivalent floor is inserted to 3, 5 and 7 storey steel structures with 2, 3 and 5 plan aspect ratios in two categories of structures with rigid diaphragms and analogous structures with flexible diaphragms and the responses are compared to each other.

Findings

The results show that the proposed technique is an effective method for evaluating the diaphragm action of steel-deck composite floors. Additionally, it is concluded that, the boundary values of plan aspect ratio equal to 3 and λ coefficient equal to 0.5 in steel-deck composite floors, mentioned in code provisions for categorising diaphragms, are not always conservative and need to be scrutinised.

Originality/value

The proposed methodology provides simple framework for assessing the effects of in-plane flexibility of steel-deck composite on seismic response of steel structures.

Details

International Journal of Structural Integrity, vol. 9 no. 5
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 27 July 2017

Simon Mwangi

This paper aims to present the findings of a numerical investigation into the performance of the steel-concrete composite floor involved in Broadgate Phase 8 fire.

Abstract

Purpose

This paper aims to present the findings of a numerical investigation into the performance of the steel-concrete composite floor involved in Broadgate Phase 8 fire.

Design/methodology/approach

The investigation is conducted by carrying out a 3-D thermomechanical analysis of a composite floor similar to the one involved in the fire using ANSYS. Four fire scenarios are investigated, with each producing a unique stress – strain pattern. The results obtained are compared with the observations made after the fire and inferences drawn.

Findings

The results obtained are found to be correlated with the observations made after the fire. The performance of the composite floor is found to be dominated by development of large strains, leading to large deflections. Furthermore, colder parts of the structure, through redistribution of forces, are found to have a profound impact on the ability of a composite floor to resist heating effects. From the findings, it is concluded that connections’ design, occurrence of membrane action and thermal restraints were the key reasons the floor did not fail.

Originality value

The study takes a more forensic approach. This is a departure from majority of published literature, where comparison is usually between experimental and numerical results. By comparing the findings from a real fire with those of a numerical investigation, the study provides an insight into the accuracy of applying numerical models for the prediction of effects of fire on structural behaviour.

Details

Journal of Structural Fire Engineering, vol. 8 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 February 1985

Margaret Law

In this country, as well as in most others, the level of structural fire protection is set by the regulatory authorities, in terms of a specified fire resistance period. The…

Abstract

In this country, as well as in most others, the level of structural fire protection is set by the regulatory authorities, in terms of a specified fire resistance period. The engineer must demonstrate that each element of structure would survive for the required period if it were subjected to the standard fire resistance test of BS476. This is normally demonstrated by using tabular data, such as the deemed‐to‐satisfy tables in the Building Regulations, or by obtaining a report of a test of a replica of the particular element.

Details

Structural Survey, vol. 3 no. 2
Type: Research Article
ISSN: 0263-080X

Article
Publication date: 7 October 2021

Lisa Choe, Selvarajah Ramesh, Xu Dai, Matthew Hoehler and Matthew Bundy

The purpose of this paper is to report the first of four planned fire experiments on the 9.1 × 6.1 m steel composite floor assembly as part of the two-story steel framed building…

Abstract

Purpose

The purpose of this paper is to report the first of four planned fire experiments on the 9.1 × 6.1 m steel composite floor assembly as part of the two-story steel framed building constructed at the National Fire Research Laboratory.

Design/methodology/approach

The fire experiment was aimed to quantify the fire resistance and behavior of full-scale steel–concrete composite floor systems commonly built in the USA. The test floor assembly, designed and constructed for the 2-h fire resistance rating, was tested to failure under a natural gas fueled compartment fire and simultaneously applied mechanical loads.

Findings

Although the protected steel beams and girders achieved matching or superior performance compared to the prescribed limits of temperatures and displacements used in standard fire testing, the composite slab developed a central breach approximately at a half of the specified rating period. A minimum area of the shrinkage reinforcement (60 mm2/m) currently permitted in the US construction practice may be insufficient to maintain structural integrity of a full-scale composite floor system under the 2-h standard fire exposure.

Originality/value

This work was the first-of-kind fire experiment conducted in the USA to study the full system-level structural performance of a composite floor system subjected to compartment fire using natural gas as fuel to mimic a standard fire environment.

Details

Journal of Structural Fire Engineering, vol. 13 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 August 2021

Paulo A.G. Piloto, Carlos Balsa, Felipe Macedo Macêdo Gomes and Bergson Matias

Most of the numerical research and experiments on composite slabs with a steel deck have been developed to study the effect of fire during the heating phase. This manuscript aims…

Abstract

Purpose

Most of the numerical research and experiments on composite slabs with a steel deck have been developed to study the effect of fire during the heating phase. This manuscript aims to describe the thermal behaviour of composite slabs when submitted to different fire scenarios, considering the heating and cooling phase.

Design/methodology/approach

Three-dimensional numerical models, based on finite elements, are developed to analyse the temperatures inside the composite slab and, consequently, to estimate the fire resistance, considering the insulation criteria (I). The numerical methods developed are validated with experimental results available in the literature. In addition, this paper presents a parametric study of the effects on fire resistance caused by the thickness of the concrete part of the slab as well as the natural fire scenario.

Findings

The results show that, depending on the fire scenario, the fire resistance criterion can be reached during the cooling phase, especially for the thickest composite slabs. Based on the results, new coefficients are proposed for the original simplified model, proposed by the standard.

Originality/value

The developed numerical models allow us to realistically simulate the thermal effects caused by a natural fire in a composite slab and the new proposal enables us to estimate the fire resistance time of composite slabs with a steel deck, even if it occurs in the cooling phase.

Details

Journal of Structural Fire Engineering, vol. 12 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 July 2019

Said Hicham Boukhalkhal, Abd Nacer Touati Ihaddoudène, Luis Filipe Da Costa Neves, Pedro Colmar Gonçalves da Silva Vellasco and Wafa Madi

It is well known that the real behaviour of joints lies between the ideal pinned or rigid joint responses. Additionally the influence of this behaviour on the global structural…

Abstract

Purpose

It is well known that the real behaviour of joints lies between the ideal pinned or rigid joint responses. Additionally the influence of this behaviour on the global structural response has been widely studied in the past centred on the plastic resistance or the critical load. On the other hand, there are relatively few studies focusing on the dynamical response of these structures. This paper aims to discuss these issues.

Design/methodology/approach

Two types of structures with rigid and semi-rigid joints were considered. Their inelastic response was evaluated using the N2 conventional pushover method, and were later compared to the results from a full non-linear dynamic analysis.

Findings

The results indicated that increasing joint flexibility makes the structure less rigid, lengthening its fundamental period and enhancing its horizontal displacement. Furthermore, a parametric study showed that joint flexibility might be of paramount importance to low to medium rise buildings response.

Originality/value

The evaluation of the influence of joint flexibility on the inelastic behaviour of steel structures located in seismic zone is of paramount importance, and is tackled in this paper.

Details

International Journal of Structural Integrity, vol. 11 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Book part
Publication date: 21 November 2018

Jun Xiu Low, Poi Ngian Shek and Mahmood Md Tahir

Composite slabs are gaining wide acceptance in many countries as they lend themselves to faster, lighter and more economic in construction buildings. The strength of composite

Abstract

Composite slabs are gaining wide acceptance in many countries as they lend themselves to faster, lighter and more economic in construction buildings. The strength of composite slabs system relies on the bonding action between the concrete and the steel deck, the shear connections and the cross-sectional resistance of steel beam. However, structural behaviour of composite slab is a complex phenomenon and therefore experimental study is often conducted to establish the actual strength of the structure under ultimate load capacity. The main objective of this study is to determine the structural behaviour of composite slab system until ultimate limit state. Total of two specimens are examined in order to obtain failure mechanism of the composite structure under full load capacity. A new design approach of composite slab for roofing system are proposed in this study to construct a composite slab system that can float in the water but not wash away by flood. The lightweight materials in this composite construction are cold-formed steel and foam concrete. The system focuses on the concept of Industrialised building system (IBS) to reduce the cost and construction time.

Details

Improving Flood Management, Prediction and Monitoring
Type: Book
ISBN: 978-1-78756-552-4

Keywords

Article
Publication date: 11 July 2019

Hendrig Marx and Richard Walls

The Southern African Institute of Steel Construction has developed a novel cellular beam structure (CBS) for multi-storey buildings that is entirely devoid of concrete. Channel…

Abstract

Purpose

The Southern African Institute of Steel Construction has developed a novel cellular beam structure (CBS) for multi-storey buildings that is entirely devoid of concrete. Channel sections between the cellular beams support a complex sandwich flooring system, which contains a fire-resistant ceiling board, metal sheeting, an interior fibre-cement board and an access-flooring system. As for all structures, the CBS requires a fire rating. This paper aims to investigate the thermal behaviour of the CBS using numerical modelling and experimental fire testing, as it has a unique setup.

Design/methodology/approach

Experimental fire tests on the flooring system were conducted to validate finite element models, which were developed in ABAQUS. These models were then extended to include floor beams and the structural steelwork.

Findings

Good correlations were found between the experimental and numerical results, with temperature variations typically in the range of 0-5%, although with localised differences of up to 20%. This allowed larger finite element models, representing the sandwich floor system of the CBS, to be developed and analysed. A 1-hour rating can be obtained by the system in terms of insulation and integrity requirements.

Practical implications

The CBS allows for more economical steel structures, due to the rapid construction of its modular panels. A suitable fire resistance will ensure the safety of the occupants and prevent major structural damage. Steelwork and flooring temperatures are determined which has allowed for global structural analyses to be carried out.

Originality/value

The originality of this study lies in thermal analysis and testing of a new cellular beam flooring system, through determining behaviour in fire, along with beam temperatures.

Article
Publication date: 19 October 2018

Naveed Alam, Ali Nadjai, Chrysanthos Maraveas, Konstantinos Tsarvdaridis and Charles Kahanji

The purpose of this study is to investigate the effect of the airgap on thermal behaviour and structural response of fabricated slim floor beams (FSFBs) in fire.

Abstract

Purpose

The purpose of this study is to investigate the effect of the airgap on thermal behaviour and structural response of fabricated slim floor beams (FSFBs) in fire.

Design/methodology/approach

A detailed analytical model is established and validated by replicating the response of FSFBs. The validated finite element modelling method is then used to perform sensitivity analysis. First, the influence of the airgap presence is analysed, and later, the effect of the airgap size on thermal behaviour and structural response of FSFBs at elevated temperatures is investigated.

Findings

Results from the study demonstrate that the presence of the airgap has a considerable influence on their thermal behaviour and structural response of FSFBs. The size of the airgap, however, has no significant influence on their thermal and structural response in fire.

Originality/value

No investigations, experimental or analytical, are available in literature addressing the effect of airgap on the structural response of FSFBs in fire. The presence of airgap is helpful and beneficial; hence, the findings of this research can be used to develop designs for structural members with airgap as an efficient and inexpensive way to improve their response in fire.

Details

Journal of Structural Fire Engineering, vol. 10 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 21 March 2022

Jason Martinez and Ann Jeffers

A methodology for producing an elevated-temperature tension stiffening model is presented.

Abstract

Purpose

A methodology for producing an elevated-temperature tension stiffening model is presented.

Design/methodology/approach

The energy-based stress–strain model of plain concrete developed by Bažant and Oh (1983) was extended to the elevated-temperature domain by developing an analytical formulation for the temperature-dependence of the fracture energy Gf. Then, an elevated-temperature tension stiffening model was developed based on the modification of the proposed elevated-temperature tension softening model.

Findings

The proposed tension stiffening model can be used to predict the response of composite floor slabs exposed to fire with great accuracy, provided that the global parameters TS and Kres are adequately calibrated against global structural response data.

Originality/value

In a finite element analysis of reinforced concrete, a tension stiffening model is required as input for concrete to account for actions such as bond slip and tension stiffening. However, an elevated-temperature tension stiffening model does not exist in the research literature. An approach for developing an elevated-temperature tension stiffening model is presented.

1 – 10 of 28