Search results

1 – 10 of 155
Article
Publication date: 5 July 2019

Said Hicham Boukhalkhal, Abd Nacer Touati Ihaddoudène, Luis Filipe Da Costa Neves, Pedro Colmar Gonçalves da Silva Vellasco and Wafa Madi

It is well known that the real behaviour of joints lies between the ideal pinned or rigid joint responses. Additionally the influence of this behaviour on the global structural…

Abstract

Purpose

It is well known that the real behaviour of joints lies between the ideal pinned or rigid joint responses. Additionally the influence of this behaviour on the global structural response has been widely studied in the past centred on the plastic resistance or the critical load. On the other hand, there are relatively few studies focusing on the dynamical response of these structures. This paper aims to discuss these issues.

Design/methodology/approach

Two types of structures with rigid and semi-rigid joints were considered. Their inelastic response was evaluated using the N2 conventional pushover method, and were later compared to the results from a full non-linear dynamic analysis.

Findings

The results indicated that increasing joint flexibility makes the structure less rigid, lengthening its fundamental period and enhancing its horizontal displacement. Furthermore, a parametric study showed that joint flexibility might be of paramount importance to low to medium rise buildings response.

Originality/value

The evaluation of the influence of joint flexibility on the inelastic behaviour of steel structures located in seismic zone is of paramount importance, and is tackled in this paper.

Details

International Journal of Structural Integrity, vol. 11 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 12 December 2016

Jing-feng Wang, Hai-Tao Wang, Wei-Wei Shi and Hong-Yu Sheng

This paper aims to obtain fire resistance of semi-rigid joints for concrete-filled steel tubular (CFST) composite frames and temperature filed distribution of composite joints in…

Abstract

Purpose

This paper aims to obtain fire resistance of semi-rigid joints for concrete-filled steel tubular (CFST) composite frames and temperature filed distribution of composite joints in fire.

Design/methodology/approach

The temperature filed model of semi-rigid joints to CFST columns with slabs was made by using ABAQUS finite element (FE) software, in considering temperature heating-up stage of fire modelling. The effects of composite slab, fire type and construction location were discussed, and the model was verified by the test results. The temperature distribution of composite joint under three-side or four-side fire condition was studied by the sequentially coupled thermal analysis method. The temperature versus time curves and temperature distribution of various construction and location were analyzed.

Findings

The paper provides FE analysis and numerical simulation on temperature field of semi-rigid joints for CFST composite frames in fire. The effects of composite slab, fire type and construction location were discussed, and the model was verified by the test results. It suggests that the temperature distribution of composite joint in three- or four-side fire condition showed a different development trend.

Research limitations/implications

Because of the chosen FE analysis approach, the research results may lack generalizability. Therefore, researchers are encouraged to test the proposed propositions further.

Practical implications

The research results will become the scientific foundation of mechanical behavior and design method of semi-rigid CFST composite frames in fire.

Originality/value

This paper fulfils an identified need to study the temperature field distribution of the semi-rigid joints to CFST columns and investigate the mechanical behavior of the semi-rigid CFST joints in fire.

Details

Journal of Structural Fire Engineering, vol. 7 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 April 2017

Hasan Katkhuda, Nasim Shatarat and Khaled Hyari

The purpose of this paper is to detect damages in steel structures with actual connections, i.e. semi-rigid connections. The method will detect the damages by tracking the changes…

Abstract

Purpose

The purpose of this paper is to detect damages in steel structures with actual connections, i.e. semi-rigid connections. The method will detect the damages by tracking the changes in the stiffness of structural members using only a limited number of dynamic responses and without knowing the type or time history of the dynamic force applied on the structure.

Design/methodology/approach

The paper proposes a technique that combines the iterative least-square and unscented Kalman filter (UKF) methods to identify the stiffness of beams and columns in typical two-dimensional steel-framed structures with semi-rigid connections. The detection of damages is by using nonlinear time-domain structural health monitoring method.

Findings

The technique is verified by using numerical examples using noise-free and noise-included dynamic responses from two different types of dynamic forces: harmonic and blast loads. The results showed that the UKF method with iterative least-square is a powerful approach to identify and detect damages in structures that have nonlinear behavior and the method was able to detect the damages in beams with a very high accuracy for noise-free and noise-included dynamic responses. In addition, the optimum number and locations of dynamic responses (accelerometer sensors) required for damage detection were determined.

Originality/value

This paper fulfills an identified need to detect damages in steel structures using only a limited number of accelerometer sensors.

Details

International Journal of Structural Integrity, vol. 8 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 17 June 2015

Ross P. D. Johnston, Mohammed Sonebi, James B. P. Lim, Cecil G. Armstrong, Andrzej M. Wrzesien, Gasser Abdelal and Ying Hu

This paper describes the results of non-linear elasto-plastic implicit dynamic finite element analyses that are used to predict the collapse behaviour of cold-formed steel portal…

Abstract

This paper describes the results of non-linear elasto-plastic implicit dynamic finite element analyses that are used to predict the collapse behaviour of cold-formed steel portal frames at elevated temperatures. The collapse behaviour of a simple rigid-jointed beam idealisation and a more accurate semi-rigid jointed shell element idealisation are compared for two different fire scenarios. For the case of the shell element idealisation, the semi-rigidity of the cold-formed steel joints is explicitly taken into account through modelling of the bolt-hole elongation stiffness. In addition, the shell element idealisation is able to capture buckling of the cold-formed steel sections in the vicinity of the joints. The shell element idealisation is validated at ambient temperature against the results of full-scale tests reported in the literature. The behaviour at elevated temperatures is then considered for both the semi-rigid jointed shell and rigid-jointed beam idealisations. The inclusion of accurate joint rigidity and geometric non-linearity (second order analysis) are shown to affect the collapse behaviour at elevated temperatures. For each fire scenario considered, the importance of base fixity in preventing an undesirable outwards collapse mechanism is demonstrated. The results demonstrate that joint rigidity and varying fire scenarios should be considered in order to allow for conservative design.

Details

Journal of Structural Fire Engineering, vol. 6 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 23 November 2020

Oliver Bahr

Unbraced one-bay composite frames are an interesting load-bearing structure for buildings with up to three storeys. However, their fire design is demanding given the lack of…

Abstract

Purpose

Unbraced one-bay composite frames are an interesting load-bearing structure for buildings with up to three storeys. However, their fire design is demanding given the lack of simplified design methods. This paper aims to deepen the understanding of the load-bearing behaviour of both unbraced and braced frames when exposed to fire.

Design/methodology/approach

In a previous paper, a numerical model for the fire design of these frames was established and validated with good agreement against fire tests. In the current paper, this model was used to compare the typical differences between braced, semi-braced and unbraced composite frames under fire conditions. Further studies addressed the effect of different heating regimes, i.e. partial fire exposure of the columns in the frames and varying location of the ISO standard fire.

Findings

Numerical investigations showed that it is necessary to take local failure and deformation limits of the fire-exposed frames into account. On this basis, unbraced composite frames can compete with braced frames as they have to endure less thermal restraints than braced frames.

Originality/value

In contrast to other investigations on frames, the numerical model is able to take into account the shear failure, which is especially important within the frame corners. Using this model, it is shown that limited sway is reasonable to reduce thermal restraints and hence local stresses. In this regard, the concept of semi-rigid composite joints with a distinct amount of reinforcement has proven to be very rational in fire design.

Details

Journal of Structural Fire Engineering, vol. 12 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 January 2018

Oliver Bahr

The purpose of this study is to gain a deeper understanding of the structural behaviour of fire-exposed unbraced composite frames. Designers to date paid little attention to…

Abstract

Purpose

The purpose of this study is to gain a deeper understanding of the structural behaviour of fire-exposed unbraced composite frames. Designers to date paid little attention to unbraced one-bay composite frames as structural system. There are two main reasons for this. First, codes lack simplified methods for the fire design of these frames due to their sway and the linked P-Δ effects when subjected to fire, which complicates the design. Second, it is demanding to construct external composite joints for the regarded one-bay frames. Thus, external joints in composite constructions are mostly constructed as steel joints. Nevertheless, these frames offer advantages. These include increased usable space and flexibility in the building’s use, large spans, fast construction times and inherent fire resistance.

Design/methodology/approach

To profit from these benefits, two different external semi-rigid composite joint were developed for the considered one-bay composite frames. The first solution based on concrete-filled steel tube columns and the second on concrete-filled double skin tube columns. Furthermore, a numerical model was established to study the fire performance of unbraced composite frames. The model was validated against four fire tests on isolated composite joints and two large-scale fire tests on unbraced composite frames.

Findings

Overall, the predictions of the numerical model were in good agreement with the test results. Thus, the numerical model is appropriate for further investigations on the fire performance of unbraced composite frames.

Originality/value

The sequence of construction results in significant stresses in the steel section, which creates difficulties in numerical modelling and may account for the relatively few studies carried out at room temperature. For the fire design, there was, to the best knowledge of the author, to date no numerical model available that was capable of considering the sequence of construction.

Details

Journal of Structural Fire Engineering, vol. 9 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 14 July 2017

Amir Saedi Daryan and Mahmood Yahyai

This paper aims to predicting the behavior of welded angle connections (moment-rotation-temperature) in fire using artificial neural network 10.

Abstract

Purpose

This paper aims to predicting the behavior of welded angle connections (moment-rotation-temperature) in fire using artificial neural network 10.

Design/methodology/approach

An artificial neural networking model is described to predict the moment-rotation response of semi-rigid beam-to-column joints at elevated temperature.

Findings

Data from 47 experimental fire tests and verified finite element model are used for training and testing and validating the neural network models. The model’s predicted values are compared with actual test results. The results indicate that the models can predict the moment-rotation-temperature behavior of semi-rigid beam-to-column joints with very high accuracy. The developed model can be modified easily to investigate other parameters that influence the performance of joints in fire.

Originality/value

The results indicate that the models can predict the moment-rotation-temperature behavior of semi-rigid beam-to-column joints with very high accuracy. The developed model can be modified easily to investigate other parameters that influence the performance of joints in fire.

Details

Journal of Structural Fire Engineering, vol. 9 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 January 2019

Said Hicham Boukhalkhal, Abd Nacer Touati Ihaddoudène, Luis Filipe Da Costa Neves and Wafa Madi

The purpose of this paper is to investigate the static and dynamic inelastic response of rigid and semi-rigid connections of steel structures with concrete-filled steel tube…

146

Abstract

Purpose

The purpose of this paper is to investigate the static and dynamic inelastic response of rigid and semi-rigid connections of steel structures with concrete-filled steel tube (CFST) columns built in high seismic areas, and to compare it with those with open section columns.

Design/methodology/approach

CFST columns are frequently used in moment resistant steel frames located in seismic areas due to their inherent advantages, including their ductility, energy absorption capacity as well as their high bearing capacity. The smart combination of steel and concrete makes it possible to benefit from the advantages of both components to the maximum. This research work presents the nonlinear dynamic response of moment resistant steel frames with CFST columns, with rigid or semi-rigid connections, built in high seismic areas, according to the Algerian seismic code RPA 99/2003, European EC8 and American FEMA 356 to show the nonlinear characteristics of this type of structures, and their advantages over steel frames with open section columns.

Findings

The paper presents the advantages of using CFST columns with rigid and semi-rigid connections on the seismic response of portal steel frames. A high performance level in terms of ductility, plastic hinges distribution and their order of appearance has been obtained. It also shows the low effect of seismic loading on the structural elements with CFST columns compared to structures with open section columns.

Originality/value

The investigation of the numerical results has shown the possibility of their use in the seismic areas for their adequate performance, and also with respect to the design limits specified in the seismic guidelines. In addition, this study represents a first step to develop seismic performance factors for steel structures with CFST columns in Algeria, where the Algerian code do not include a comprehensive specification for the composite steel structures.

Details

International Journal of Structural Integrity, vol. 10 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 17 May 2023

Abbas Rezaeian, Mona Mansoori and Amin Khajehdezfuly

Top-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded…

Abstract

Purpose

Top-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded top-seat angle connections.

Design/methodology/approach

A finite element (FE) model, including nonlinear contact interactions, high-temperature properties of steel, and material and geometric nonlinearities was created for accomplishing the fire performance analysis. The FE model was verified by comparing its simulation results with test data. Using the verified model, 24 steel-framed top-seat angle connection assemblies are modeled. Parametric studies were performed employing the verified FE model to study the influence of critical factors on the performance of steel beams and their welded angle joints.

Findings

The results obtained from the parametric studies illustrate that decreasing the gap size and the top angle size and increasing the top angles thickness affect fire behavior of top-seat angle joints and decrease the beam deflection by about 16% at temperatures beyond 570 °C. Also, the fire-resistance rating of the beam with seat angle stiffener increases about 15%, compared to those with and without the web stiffener. The failure of the beam happens when the deflections become more than span/30 at temperatures beyond 576 °C. Results also show that load type, load ratio and axial stiffness levels significantly control the fire performance of the beam with top-seat angle connections in semi-rigid steel frames.

Originality/value

Development of design methodologies for these joints and connected beam in fire conditions is delayed by current building codes due to the lack of adequate understanding of fire behavior of steel beams with welded top-seat angle connections.

Details

Journal of Structural Fire Engineering, vol. 15 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 2 January 2024

Xu Li, Zeyu Xiao, Zhenguo Zhao, Junfeng Sun and Shiyuan Liu

To explore the economical and reasonable semi-rigid permeable base layer ratio, solve the problems caused by rainwater washing over the pavement base layer on the slope, improve…

Abstract

Purpose

To explore the economical and reasonable semi-rigid permeable base layer ratio, solve the problems caused by rainwater washing over the pavement base layer on the slope, improve its drainage function, improve the water stability and service life of the roadbed pavement and promote the application of semi-rigid permeable base layer materials in the construction of asphalt pavement in cold regions.

Design/methodology/approach

In this study, three semi-rigid base course materials were designed, the mechanical strength and drainage properties were tested and the effect and correlation of air voids on their performance indexes were analyzed.

Findings

It was found that increasing the cement content increased the strength but reduced the air voids and water permeability coefficient. The permeability performance of the sandless material was superior to the dense; the performance of the two sandless materials was basically the same when the cement content was 7%. Overall, the skeleton void (sand-containing) type gradation between the sandless and dense types is more suitable as permeable semi-rigid base material; its gradation is relatively continuous, with cement content? 4.5%, strength? 1.5 MPa, water permeability coefficient? 0.8 cm/s and voids of 18–20%.

Originality/value

The study of permeable semi-rigid base material with large air voids could help to solve the problems of water damage and freeze-thaw damage of the base layer of asphalt pavements in cold regions and ensure the comfort and durability of asphalt pavements while having good economic and social benefits.

Details

International Journal of Structural Integrity, vol. 15 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords