Publication date: 27 July 2017

Simon Mwangi

This paper aims to present the findings of a numerical investigation into the performance of the steel-concrete composite floor involved in Broadgate Phase 8 fire.

Abstract

Purpose

This paper aims to present the findings of a numerical investigation into the performance of the steel-concrete composite floor involved in Broadgate Phase 8 fire.

Design/methodology/approach

The investigation is conducted by carrying out a 3-D thermomechanical analysis of a composite floor similar to the one involved in the fire using ANSYS. Four fire scenarios are investigated, with each producing a unique stress – strain pattern. The results obtained are compared with the observations made after the fire and inferences drawn.

Findings

The results obtained are found to be correlated with the observations made after the fire. The performance of the composite floor is found to be dominated by development of large strains, leading to large deflections. Furthermore, colder parts of the structure, through redistribution of forces, are found to have a profound impact on the ability of a composite floor to resist heating effects. From the findings, it is concluded that connections’ design, occurrence of membrane action and thermal restraints were the key reasons the floor did not fail.

Originality value

The study takes a more forensic approach. This is a departure from majority of published literature, where comparison is usually between experimental and numerical results. By comparing the findings from a real fire with those of a numerical investigation, the study provides an insight into the accuracy of applying numerical models for the prediction of effects of fire on structural behaviour.

Details

Journal of Structural Fire Engineering, vol. 8 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 31 March 2022

Seyed Vahid Khonsari, Shahin Nejati, Mohammadreza Rahdan and Mahdi Ahmadi

The paper aims to report a fire test conducted on a three-dimensional frame in order to investigate the behaviour of bare steel flush end-plate connections with relatively low…

Abstract

Purpose

The paper aims to report a fire test conducted on a three-dimensional frame in order to investigate the behaviour of bare steel flush end-plate connections with relatively low thickness at elevated temperatures.

Design/methodology/approach

A half-scale model was fabricated and exposed to modified (scaled) ISO 834 heating curve using a semi-open furnace. The maximum temperature inside the furnace reached 1,026 °C.

Findings

The rotations of connections are reported and compared with those of a previous study on an exactly the same model with thick end-plates. Various modes of failure such as local buckling of the beams flanges and lateral-torsional buckling of beams were observed during the test. Finally, the structure collapsed after 29 min of heating due to the fracture of weld between one of the beams and one of its attached end-plates whilst the other beam had undergone a maximum deflection of 35 cm (≈ 1/6 span length). Other observed failure modes included bolt fracture, bolt thread stripping and large inelastic deformation of the end-plates.

Originality/value

Although the adoption of thin end-plates increased the rotational capacity of the connections, it did not improve the robustness of the structure under fire conditions.

Details

Journal of Structural Fire Engineering, vol. 14 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 December 2016

Serdar Selamet and Caner Bolukbas

This paper aims to present a numerical investigation on the fire performance of a single plate shear connection in a steel-framed composite floor. Large-scale fire experiments…

Abstract

Purpose

This paper aims to present a numerical investigation on the fire performance of a single plate shear connection in a steel-framed composite floor. Large-scale fire experiments show that the tensile membrane action of the concrete slab enhances the fire performance of composite floors. The enhancement in the performance is contributed to large slab deflections. However, these deflections cause significant rotations and tensile force in the single plate connection.

Design/methodology/approach

A finite element model is constructed, which consists of a secondary steel beam, concrete slab and shear connection components. The interaction between the connection components such as bolts and single plate is defined by contact surfaces. The analysis is conducted in two uncoupled phases: thermal analysis by creating fire boundaries on the composite floor model with convective and radiative heat transfer, and mechanical analysis by considering thermal expansion and changes in the material stiffness and strength due to temperature.

Findings

The thermo-mechanical analysis of the composite floor finite element model shows that the structure survives the 2-h Standard fire, but the connection fails by bolt shear and buckling of the connection plate.

Originality/value

This paper investigates the fire performance of a shear connection in a steel-framed concrete slab. Previous work generally focused on the concrete slab behavior only. The originality of the research is that the connection is considered as part of a sub-assembly and is subjected to forces due to concrete and steel beam interaction.

Details

Journal of Structural Fire Engineering, vol. 7 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 11 July 2017

Chrysanthos Maraveas

The DELTA® beam composite floor system is a recently developed shallow floor type that has seen many applications in contemporary construction. It involves partially encasing…

Abstract

Purpose

The DELTA® beam composite floor system is a recently developed shallow floor type that has seen many applications in contemporary construction. It involves partially encasing DELTA® steel beams in concrete, with the lower flange remaining exposed. Besides the satisfactory behavior of the system at ambient conditions, understanding its response under elevated temperatures is critical in evaluating its overall performance. Despite certification from the manufacturing company that the system has adequate fire resistance, its behavior under fire conditions has neither been investigated to depth nor reported in detail. The purpose of this paper is the detailed numerical investigation of their behavior in fire. For this reason, the finite element method was implemented in this paper to simulate the response of such beams subjected to fire. Material properties were modeled according to the Eurocodes. The coupled thermal-structural parametric analyses involved four different variations of the “shortest” and “deepest” cross-section (eight case studies in total) specified by the manufacturing company. Other simulations of these cross-sections, in which either the thermal expansion or the structural load were not taken into account, were carried out for comparison purposes.

Design/methodology/approach

The methodology for simulating such systems, which has been successfully implemented and validated against fire test results elsewhere (Maraveas et al., 2012) was also followed here. To investigate the statement made by Maraveas et al. (2014) and the equations proposed by Zaharia and Franssen (2012) that the insulation is not so effective for “short” cross-sections, two beams, one with a D20-200 (Deltabeam Technical Manual, 2013) cross-section (shallowest section) and one with a D50-600 (Deltabeam Technical Manual, 2013) cross-section (deepest section), were simulated in this paper for comparison purposes. Additionally, reasonable assumptions were made for the cross-sectional dimensions not specified by the manufacturer (Deltabeam Technical Manual, 2013) and parametric analyses were carried out to investigate their effect on the structural response of the system.

Findings

Composite DELTA® beams can achieve fire resistances ranging from 120 to 180 min, depending on the depth and geometry of their cross-section, with deeper sections displaying a better fire response. The intense thermal bowing that occurs when these beams are heated from below has a more pronounced effect, in terms of thermally induced deflections for deeper sections. The satisfactory fire resistance of these beams is achieved due to the action of the concrete encased web and the reinforcement which compensate for the loss of the exposed lower flange. Increasing the thickness of the web in deeper sections improves their fire rating up to 180 min. The thickness of the lower flange affects the fire rating of the beams only in a minor way.

Practical/implications

The paper describes a numerical methodology to estimate the fire resistance of complex flooring systems.

Details

Journal of Structural Fire Engineering, vol. 8 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 March 2017

Anthony Deloge Ariyanayagam and Mahen Mahendran

This paper aims to present the details of a study undertaken to develop an energy-based time equivalent approach to obtain the fire resistance ratings (FRRs) of light gauge steel…

Abstract

Purpose

This paper aims to present the details of a study undertaken to develop an energy-based time equivalent approach to obtain the fire resistance ratings (FRRs) of light gauge steel frame (LSF) walls exposed to realistic design fire curves.

Design/methodology/approach

The energy-based time equivalent method was developed based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of the standard fire time – temperature curve. The FRR predicted by the energy-based method for LSF wall configurations exposed to both rapid and prolonged fires were compared with those from fire design rules and finite element analyses (FEA).

Findings

The proposed energy method can be used to obtain the FRR of LSF walls in case of prolonged fires and cannot be used for rapid fires as the computed FRRs were higher than the results from FEA and fire design rules due to the influence of thermal bowing and its magnification effects at a high temperature gradient across the studs for rapid fires.

Originality/value

The energy-based time equivalent method was developed based on equal fire severity principles. Three different wall configurations were considered and exposed to both rapid and prolonged fires. The FRR obtained from the energy-based method were compared with fire design rules and FEA results to assess the use of the energy-based method to predict the FRR of LSF walls.

Details

Journal of Structural Fire Engineering, vol. 8 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 June 2017

Sivakumar Kesawan and Mahen Mahendran

This paper aims to present an investigation conducted to evaluate the effects of important parameters affecting the structural fire performance of light gauge steel frame (LSF…

Abstract

Purpose

This paper aims to present an investigation conducted to evaluate the effects of important parameters affecting the structural fire performance of light gauge steel frame (LSF) walls. It also evaluates the applicability of commonly used critical hot flange temperature method to determine the fire resistance ratings (FRR) of different LSF walls.

Design/methodology/approach

The effects of important parameters such as stud section profiles and their dimensions, elevated temperature mechanical property reduction factors of the steel used, types of wall configurations and fire curves on the FRR of LSF walls were investigated. An extensive finite element analysis-based parametric study was conducted to evaluate their effects (finite element analysis – FEA). For this purpose, finite element models which were validated using the full-scale fire test results were used. Using the structural capacities obtained from FEAs, the load ratio versus FRR curves were produced for all the different LSF walls considered.

Findings

Stud depth and thickness significantly affected the fire performance of LSF walls because of the differences in temperature development pattern, thermal bowing deflections and the failure modes of stud. The FRR of LSF walls increased significantly when steel studs with higher elevated temperature mechanical property reduction factors were used. FRR significantly changed when realistic design fire curves were used instead of the standard fire curve. Furthermore, both the critical hot and average flange temperature methods were found to be unsuitable to predict the FRR of LSF walls.

Originality/value

The developed comprehensive fire performance data would facilitate the development of LSF walls with enhanced fire performance, and, importantly, it would facilitate and advance the successful applications of hollow flange channel section studs in LSF walls.

Details

Journal of Structural Fire Engineering, vol. 8 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 4 September 2019

Richard Walls, Celeste Viljoen and Hennie de Clercq

This paper aims to provide a parametric investigation into the behaviour of steel, concrete and composite beams exposed to fire. This investigation gives insight into the…

Abstract

Purpose

This paper aims to provide a parametric investigation into the behaviour of steel, concrete and composite beams exposed to fire. This investigation gives insight into the structural behaviour of elements experiencing thermal and mechanical loading illustrating reasons for observed global structural behaviour, and identifying how selected design parameters influence results obtained. Non-linear heating/thermal bowing behaviour is specifically considered.

Design/methodology/approach

Cross-sectional stresses and strains, resultant thermal forces, bending stiffness, axial stiffness and deflections are plotted for beams subjected to different fire regimes or input values. The impact of changes in input parameters on beam section properties is illustrated. Unusual structural responses, localised effects and general trends are identified in relation to variations in thermal gradients, concrete tensile capacity, standard fire exposure time and the assumed concrete flange widths of composite beams.

Findings

Stress-strain plots highlighting cross-sectional structural behaviour, trends in beam properties and the influence of design parameters are provided. Some counter-intuitive behaviour is explained, such as increased member stiffness being offset by increased thermal effects, leading to this parameter having negligible impact on global behaviour but a significant effect on local stresses and strains. Increased concrete strengths may lead to increased thermal deformations, whilst the inclusion of concrete tensile capacity typically has a minimal influence.

Research limitations/implications

The research focusses on cross-sectional properties, although results generated illustrate how global behaviour is affected.

Practical implications

Design engineers are made aware of how selected input values influence predicted structural response. Also, localised stress and strain behaviour relative to imposed loads and thermal effects can be identified.

Originality/value

This paper provides novel insight into the (sometimes counter-intuitive) behaviour of beams exposed to fire, highlighting trends and the influence of important input parameters on predicted response.

Details

Journal of Structural Fire Engineering, vol. 11 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 January 1991

S. Hamilton

Current techniques for bonding thermal planes or heat sinks utilise materials and methods initially designed for other applications and so have several disadvantages. The new…

Abstract

Current techniques for bonding thermal planes or heat sinks utilise materials and methods initially designed for other applications and so have several disadvantages. The new system described in this paper has been developed to give the optimum combination of bonding properties for this specific application.

Details

Circuit World, vol. 17 no. 2
Type: Research Article
ISSN: 0305-6120

Article
Publication date: 27 November 2023

Maha Assad, Rami Hawileh, Ghada Karaki, Jamal Abdalla and M.Z. Naser

This research paper aims to investigate reinforced concrete (RC) walls' behaviour under fire and identify the thermal and mechanical factors that affect their performance.

Abstract

Purpose

This research paper aims to investigate reinforced concrete (RC) walls' behaviour under fire and identify the thermal and mechanical factors that affect their performance.

Design/methodology/approach

A three-dimensional (3D) finite element (FE) model is developed to predict the response of RC walls under fire and is validated through experimental tests on RC wall specimens subjected to fire conditions. The numerical model incorporates temperature-dependent properties of the constituent materials. Moreover, the validated model was used in a parametric study to inspect the effect of the fire scenario, reinforcement concrete cover, reinforcement ratio and configuration, and wall thickness on the thermal and structural behaviour of the walls subjected to fire.

Findings

The developed 3D FE model successfully predicted the response of experimentally tested RC walls under fire conditions. Results showed that the fire resistance of the walls was highly compromised under hydrocarbon fire. In addition, the minimum wall thickness specified by EC2 may not be sufficient to achieve the desired fire resistance under considered fire scenarios.

Originality/value

There is limited research on the performance of RC walls exposed to fire scenarios. The study contributed to the current state-of-the-art research on the behaviour of RC walls of different concrete types exposed to fire loading, and it also identified the factors affecting the fire resistance of RC walls. This guides the consideration and optimisation of design parameters to improve RC walls performance in the event of a fire.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 6 December 2021

Yu Liu, Shan-Shan Huang and Ian Burgess

In order to improve the robustness of bare-steel and composite structures in fire, a novel axially and rotationally ductile connection has been proposed in this paper.

130

Abstract

Purpose

In order to improve the robustness of bare-steel and composite structures in fire, a novel axially and rotationally ductile connection has been proposed in this paper.

Design/methodology/approach

The component-based models of the bare-steel ductile connection and composite ductile connection have been proposed and incorporated into the software Vulcan to facilitate global frame analysis for performance-based structural fire engineering design. These component-based models are validated against detailed Abaqus FE models and experiments. A series of 2-D bare-steel frame models and 3-D composite frame models with ductile connections, idealised rigid and pinned connections, have been created using Vulcan to compare the fire performance of ductile connection with other connection types in bare-steel and composite structures.

Findings

The comparison results show that the proposed ductile connection can provide excellent ductility to accommodate the axial deformation of connected beam under fire conditions, thus reducing the axial forces generated in the connection and potentially preventing the premature brittle failure of the connection.

Originality/value

Compared with conventional connection types, the proposed ductile connection exhibits considerable deformability, and can potentially enhance the robustness of structures in fire.

Details

Journal of Structural Fire Engineering, vol. 13 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

1 – 10 of 328