Article
Publication date: 3 October 2022

Sara Mirzabagheri and Osama (Sam) Salem

Since columns are critical structural elements, they shall withstand hazards without any considerable damage. In the case of a fire, although concrete has low thermal conductivity…

82

Abstract

Purpose

Since columns are critical structural elements, they shall withstand hazards without any considerable damage. In the case of a fire, although concrete has low thermal conductivity compared to other construction materials, its properties are changed at elevated temperatures. Most critically, the residual compressive strengths of reinforced concrete columns are significantly reduced after fire exposure. Validation of the worthiness of rehabilitating concrete structures after fire exposure is highly dependent on accurately determining the residual strengths of fire-damaged essential structural elements such as columns.

Design/methodology/approach

In this study, eight reinforced-concrete columns (200 × 200 × 1,500 mm) that were experimentally examined in a prior related study have been numerically modelled using ABAQUS software to investigate their residual compressive strengths after exposure to different durations of standard fire (i.e. one and two hours) while subjected to different applied load ratios (i.e. 20 and 40% of the compressive resistance of the column). Outcomes of the numerical simulations were verified against the prior study's experimental results.

Findings

In a subsequent phase, the results of a parametric study that has been completed as part of the current study to investigate the effects of the applied load ratios show that the application of axial load up to 80% of the compressive resistance of the column did not considerably influence the residual compressive strength of the shorter columns (i.e. 1,500 and 2,000-mm high). However, increasing the height of the column to 2,500 or 3,000 mm considerably reduced the residual compressive strength when the load ratio applied on the columns exceeded 60 and 40%, respectively. Also, when the different columns were simulated under two-hour standard fire exposure, the dominant failure was buckling rather than concrete crushing which was the typical failure mode in most columns.

Originality/value

The outcomes of the numerical study presented in this paper reflect the residual compressive strength of RC columns subjected to various applied load ratios and standard fire durations. Also, the parametric study conducted as part of this research on the effects of higher load ratios and greater column heights on the residual compressive strength of the fire-damaged columns is practical and efficient. The developed computer models can be beneficial to assist engineers in assessing the validity of rehabilitating concrete structures after being exposed to fire.

Details

Journal of Structural Fire Engineering, vol. 14 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 27 July 2020

Anjaly Nair and Osama (Sam) Salem

At elevated temperatures, concrete undergoes changes in its mechanical and thermal properties, which mainly cause degradation of strength and eventually may lead to the failure of…

Abstract

Purpose

At elevated temperatures, concrete undergoes changes in its mechanical and thermal properties, which mainly cause degradation of strength and eventually may lead to the failure of the structure. Retrofitting is a desirable option to rehabilitate fire damaged concrete structures. However, to ensure safe reuse of fire-exposed buildings and to adopt proper retrofitting methods, it is essential to evaluate the residual load-bearing capacity of such fire-damaged reinforced concrete structures. The focus of the experimental study presented in this paper aims to investigate the fire performance of concrete columns exposed to a standard fire, and then evaluate its residual compressive strengths after fire exposure of different durations.

Design/methodology/approach

To effectively study the fire performance of such columns, eight identical 200 × 200 × 1,500-mm high reinforced concrete columns test specimens were subjected to two different fire exposure (1- and 2-h) while being loaded with two different load ratios (20% and 40% of the column ultimate design axial compressive load). In a subsequent stage and after complete cooling down, residual compressive strength capacity tests were performed on each fire exposed column.

Findings

Experimental results revealed that the columns never regain its original capacity after being subjected to a standard fire and that the residual compressive strength capacity dropped to almost 50% and 30% of its ambient temperature capacity for the columns exposed to 1- and 2-h fire durations, respectively. It was also noticed that, for the tested columns, the applied load ratio has much less effect on the column’s residual compressive strength compared to that of the fire duration.

Originality/value

According to the unique outcomes of this experimental study and, as the fire-damaged concrete columns possessed considerable residual compressive strength, in particular those exposed to shorter fire duration, it is anticipated that with proper retrofitting techniques such as fiber-reinforced polymers (FRP) wrapping, the fire-damaged columns can be rehabilitated to regain at least portion of its lost load-bearing capacities. Accordingly, the residual compressive resistance data obtained from this study can be effectively used but not directly to adopt optimal retrofitting strategies for such fire-damaged concrete columns, as well as to be used in validating numerical models that can be usefully used to account for the thermally-induced degradation of the mechanical properties of concrete material and ultimately predict the residual compressive strengths and deformations of concrete columns subjected to different load intensity ratios for various fire durations.

Details

Journal of Structural Fire Engineering, vol. 11 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 21 August 2023

Yaobing Wei, Xuexue Wang, Jianhui Liu, Jianwei Li and Yichen Pan

Engineering composite laminates/structures are usually subjected to complex and variable loads, which result in interlayer delamination damage. However, damaged laminate may cause…

Abstract

Purpose

Engineering composite laminates/structures are usually subjected to complex and variable loads, which result in interlayer delamination damage. However, damaged laminate may cause the whole structure to fail before reaching the design level. Therefore, the purpose of this paper is to develop an equivalent model to effectively evaluate compressive residual strength.

Design/methodology/approach

In this paper, taking carbon fiber reinforced composite T300/69 specimens as the study object, first, the compressive residual strength under different impact energy is obtained. Then, zero-thickness cohesive elements, Hashin failure criteria and Camanho nonlinear degradation scheme are used to simulate the full-process simulation for compression after edge impact (CAEI). Lastly, based on an improved Whitney–Nuismer criterion, the equation of edge hole stress distribution, characteristic length and compressive residual strength is used to verify the correctness of the equivalent model.

Findings

An equivalent relationship between the compressive residual strength of damaged laminates and laminates with edge hole is established. For T300/69 laminates with a thickness of 2.4 mm, the compressive residual strength after damage under an impact energy of 3 J is equivalent to that when the hole aperture R = 2.25 mm and the hole aperture R = 9.18 mm when impact energy is 6 J. Besides, the relationship under the same size and different thickness is obtained.

Originality/value

The value of this study is to provide a reference for the equivalent behavior of damaged laminates. An equivalent model proposed in this paper will contribute to the research of compressive residual strength and provide a theoretical basis for practical engineering application.

Details

International Journal of Structural Integrity, vol. 14 no. 5
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 17 July 2017

Hassan A.M. Mhamoud and Jia Yanmin

This study aims to investigate the effectiveness of different additives (individual effects) in improving the strength of concrete to resist temperatures of up to 60ºC.

Abstract

Purpose

This study aims to investigate the effectiveness of different additives (individual effects) in improving the strength of concrete to resist temperatures of up to 60ºC.

Design/methodology/approach

In all, 13 different mixtures with a constant water/binder ratio of 0.36 and grade M40 were prepared by using ordinary Portland concrete alone, or with partial replacement by fly ash (FA), blast-furnace slag, silica fume (SF) and a combination of all three. After 7 and 28 days under water, their strength and residual strength were measured.

Findings

The results of testing revealed that the addition of 10 per cent SF was found to result in the greatest increase in compressive strength and flexural strength along with decreased the residual strengths. The addition of FA increased the compressive strength and enhanced the residual compressive strength. However, it also decreased the residual flexural strength.

Originality/value

The addition of slag achieved better flexural strength and the best residual compressive strength. The combination of additives also enhanced the compressive strength but was not found to be better than using SF alone.

Details

Journal of Structural Fire Engineering, vol. 9 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 20 February 2020

Daniel Paul Thanaraj, Anand N. and Prince Arulraj

The purpose of this study is to investigate the effect of standard fire on the strength and microstructure properties of concrete with different strength grades.

Abstract

Purpose

The purpose of this study is to investigate the effect of standard fire on the strength and microstructure properties of concrete with different strength grades.

Design/methodology/approach

Different strength grades of concrete used for the investigation are M20, M30, M40 and M50. An electrical bogie hearth furnace was developed to simulate the International Standards Organization 834 standard fire curve.Concrete samples were subjected to high temperatures of 925, 1,029, 1,090 and 1,133°C for the duration of 1, 2, 3 and 4 h, respectively, as per standard fire curve. Compressive strength, tensile strength, thermal crack pattern and spalling of heated concrete specimens were evaluated by experimental investigation. Scanning electron microscopy and thermo-gravimetric analysis were performed to investigate the microstructure properties of heated concrete specimens.

Findings

Test results indicated reduction in the strength and changes in the microstructure properties of concrete exposed to elevated temperature. The degree of weight and the strength loss were found to be higher for concrete with higher grades. An empirical relation is proposed to determine the residual strength of concrete with different strength grade using regression analysis.

Social implications

Results of this research will be useful for the design engineers to understand the behavior of concrete exposed to elevated temperature as per standard fire.

Originality/value

When concrete is exposed to elevated temperature, its internal microstructure changes, thereby strength and durability of concrete deteriorates. The performance of concrete with different strength grade exposed to standard fire is well understood. This research’s findings will be useful for the designers to understand more about fire resistance of concrete. A simple relationship is proposed to determine the residual strength of concrete exposed to various durations of heating.

Details

Journal of Structural Fire Engineering, vol. 11 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 14 August 2017

Hassan A.M. Mhamoud and Jia Yanmin

This study aims to focus on the resistance to elevated temperatures of up to 700ºC of high-performance concrete (HPC) compared to ordinary Portland concrete (OPC) with regards to…

Abstract

Purpose

This study aims to focus on the resistance to elevated temperatures of up to 700ºC of high-performance concrete (HPC) compared to ordinary Portland concrete (OPC) with regards to mass loss and residual compressive and flexural strength.

Design/methodology/approach

Two mixtures were developed to test. The first mixture, OPC, was used as the control, and the second mixture was HPC. After 28 days under water (per Chinese standard), the samples were tested for compressive strength and residual strength.

Findings

The test results showed that at elevated temperatures of up to 500ºC, each mixture experienced mass loss. Below this temperature, the strength and the mass loss did not differ greatly.

Originality/value

When adding a 10 per cent silica fume, 25 per cent fly, 25 per cent slag to HPC, the compressive strength increased by 17 per cent and enhanced the residual compressive strength. A sharp decrease was observed in the residual flexural strength of HPC when compared to OPC after exposure to temperatures of 700ºC.

Details

Journal of Structural Fire Engineering, vol. 8 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 15 May 2019

Daniel Paul Thanaraj, Anand N. and Prince Arulraj

This paper aims to explain the influence of Standard Fire as per ISO 834 on the strength and microstructure properties of concrete specimens with different strength grade.

Abstract

Purpose

This paper aims to explain the influence of Standard Fire as per ISO 834 on the strength and microstructure properties of concrete specimens with different strength grade.

Design/methodology/approach

The strength grades of concrete considered for the experimental investigation were Fck20, Fck30, Fck40 and Fck50. The specimens were heated up to 1, 2, 3 and 4 h as per standard fire curve. Effect of elevated temperature on compressive and flexural behavior of specimens with various strength grades was examined. Effects of age of concrete, weight loss, surface characteristics and thermal crack pattern were also investigated.

Findings

Experimental investigation shows that strength grade, duration of exposure and age of concrete are the key parameters affecting the residual strength of concrete. For the beams exposed to 3 and 4 h of heating, the residual flexural strength was found to be so insignificant that the specimens were not able to even sustain their own weight. The loss in compressive and flexural strength of Fck50 concrete specimens heated up to 1 h were found to be 26.41 and 86.03 per cent of the original unheated concrete, respectively. The weight loss was found to be more for higher grade concrete specimens, and it was about 8.38 per cent for Fck50 concrete. Regression analysis was carried out to establish the empirical relation between residual strength and grade of concrete. Scanning electron microscopy and thermogravimetric analysis were carried out to examine the damage level of fire-affected concrete specimens.

Originality/value

Empirical relationship was developed to determine the residual strength of concrete exposed to elevate temperature, and this will be useful for design applications. This database may be useful for identifying member strength of reinforced beams subjected to various durations of heating so that suitable repair technique can be adopted from the available database. It will be useful to identify the proper grade of concrete with regard to fire endurance, in the case of concrete under compression or flexure.

Details

Journal of Engineering, Design and Technology , vol. 17 no. 5
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 28 February 2019

Hala Mohamed Elkady, Ahmed M. Yasien, Mohamed S. Elfeky and Mohamed E. Serag

This paper aims to inspect the effect of indirect elevated temperature on the mechanical performance of nano silica concrete (NSC). The effect on both compressive and bond…

Abstract

Purpose

This paper aims to inspect the effect of indirect elevated temperature on the mechanical performance of nano silica concrete (NSC). The effect on both compressive and bond strengths is studied. Pre- and post-exposure to elevated temperature ranges of 200 to 600°C is examined. A range covered by three percentages of 1.5, 3 and 4.5 per cent nano silica (NS) in concrete mixes is tested.

Design/methodology/approach

Pre-exposure mechanical tests (normal conditions – room temperature), using 3 per cent NS in the concrete mix, led to the highest increase in both compressive and bond strengths (43 per cent and 38.5 per cent, respectively), compared to the control mix without NS (based on 28-day results). It is worth noticing that adding NS to the concrete mixes does not have a significant effect on improving early-age strength. Besides, permeability tests are performed on NSC with different NS ratios. NS improved the concrete permeability for all tested percentages of NS. The maximum reduction is accompanied by the maximum percentage used (4.5 per cent NS in the NSC mix), reducing permeability to half the value of the concrete mix without NS. As for post-exposure to elevated-temperature mechanical tests, NSC with 1.5 per cent NS exhibited the lowest loss in strength owing to indirect heat exposure of 600°C; the residual compressive and bond strengths are 73 per cent and 35 per cent, respectively.

Findings

The dispersion technique of NS has a key role in NSC-distinguished mechanical performance with NSC having lower NS percentages. NS significantly improved bond strength. NS has a remarkable effect on elevated temperature endurance. The bond strength of NSC exposed to elevated temperatures suffered faster deterioration than compressive strength of the exposed NSC.

Research limitations/implications

A special scale factor needs to be investigated for the NSC.

Originality/value

Although a lot of effort is placed in evaluating the benefits of using nano materials in structural concrete, this paper presents one of the first outcomes of the thermal effects on concrete mixes with NS as a partial cement replacement.

Details

Journal of Structural Fire Engineering, vol. 10 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 October 2021

Indunil Erandi Ariyaratne, Anthony Ariyanayagam and Mahen Mahendran

This paper presents the details of a research study on developing composite masonry blocks using two types of mixes, conventional and lightweight mix, to enhance their…

Abstract

Purpose

This paper presents the details of a research study on developing composite masonry blocks using two types of mixes, conventional and lightweight mix, to enhance their fire/bushfire resistance and residual compressive strength.

Design/methodology/approach

Composite masonry blocks (390 × 190 × 90 mm) were fabricated using conventional cement–sand mix as the outer layer and lightweight cement–sand–diatomite mix as the inner layer. Material properties were determined, and all the mixes were proportioned by the absolute volume method. After 28 days of curing, density tests, compression tests before and after fire exposure and fire resistance tests of the developed blocks were conducted, and the results were compared with those of conventional cement–sand and cement–sand–diatomite blocks.

Findings

Developed composite blocks satisfy density and compressive strength requirements for loadbearing lightweight solid masonry units. Fire resistance of the composite block is –/120/120, and no cracks appeared on the ambient side surface of the block after 3 h of fire exposure. Residual strength of the composite block is higher compared to cement–sand and cement–sand–diatomite blocks and satisfies the loadbearing solid masonry unit strength requirements.

Practical implications

Composite block developed in this research can be suggested as a suitable loadbearing lightweight solid masonry block for several applications in buildings in bushfire prone areas.

Originality/value

Limited studies are available for composite masonry blocks in relation to their fire resistance and residual strength.

Details

Journal of Structural Fire Engineering, vol. 13 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 8 October 2020

Sachin V. and N. Suresh

Concrete is a widely used construction material which can be prepared using locally available resources (aggregates, cement and water) by following relevant standard guidelines…

169

Abstract

Purpose

Concrete is a widely used construction material which can be prepared using locally available resources (aggregates, cement and water) by following relevant standard guidelines. The residual properties of concrete determined by heating in an electric furnace may not produce a similar effect of fire. The purpose of this paper is to compare the effect of a fire with that coming from the exposure of normal strength concrete to predetermined reference temperatures, for which two sets of specimens were heated in a fire furnace provided with gas burners and an electric furnace.

Design/methodology/approach

The concrete cubes and cylinders were subjected to 200oC, 400oC, 600oC and 800oC temperature in a gas-controlled fire furnace and an electric furnace for 2 h. The physical properties and mechanical properties of concrete were determined after cooling the specimens in air. The quality of concrete specimens was determined using the ultrasonic pulse velocity test, and surface hardness of the heat-exposed cubes was recorded using the Schmidt rebound hammer.

Findings

The fire-exposed specimens were found to have lower residual compressive strength, tensile strength and higher porosity/voids/internal cracks than the specimens heated in an electric furnace at the same temperature. Further, a good agreement with compressive strength and rebound numbers was observed for each of the two heating systems (flames coming from gas burners and electric furnace).

Originality/value

Normal strength concrete specimens exposed to heat in an electric furnace will not give the same effect of fire having the same maximum temperature. Further, it is noticed that concrete subjected to elevated temperature is sensitive to heating modalities, be it the flames of a gas furnace or the radiation of an electric furnace.

Details

Journal of Structural Fire Engineering, vol. 12 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords