Search results

1 – 10 of 516
Article
Publication date: 12 June 2017

Sivakumar Kesawan and Mahen Mahendran

This paper aims to present an investigation conducted to evaluate the effects of important parameters affecting the structural fire performance of light gauge steel frame (LSF…

Abstract

Purpose

This paper aims to present an investigation conducted to evaluate the effects of important parameters affecting the structural fire performance of light gauge steel frame (LSF) walls. It also evaluates the applicability of commonly used critical hot flange temperature method to determine the fire resistance ratings (FRR) of different LSF walls.

Design/methodology/approach

The effects of important parameters such as stud section profiles and their dimensions, elevated temperature mechanical property reduction factors of the steel used, types of wall configurations and fire curves on the FRR of LSF walls were investigated. An extensive finite element analysis-based parametric study was conducted to evaluate their effects (finite element analysis – FEA). For this purpose, finite element models which were validated using the full-scale fire test results were used. Using the structural capacities obtained from FEAs, the load ratio versus FRR curves were produced for all the different LSF walls considered.

Findings

Stud depth and thickness significantly affected the fire performance of LSF walls because of the differences in temperature development pattern, thermal bowing deflections and the failure modes of stud. The FRR of LSF walls increased significantly when steel studs with higher elevated temperature mechanical property reduction factors were used. FRR significantly changed when realistic design fire curves were used instead of the standard fire curve. Furthermore, both the critical hot and average flange temperature methods were found to be unsuitable to predict the FRR of LSF walls.

Originality/value

The developed comprehensive fire performance data would facilitate the development of LSF walls with enhanced fire performance, and, importantly, it would facilitate and advance the successful applications of hollow flange channel section studs in LSF walls.

Details

Journal of Structural Fire Engineering, vol. 8 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 March 2017

Anthony Deloge Ariyanayagam and Mahen Mahendran

This paper aims to present the details of a study undertaken to develop an energy-based time equivalent approach to obtain the fire resistance ratings (FRRs) of light gauge steel

Abstract

Purpose

This paper aims to present the details of a study undertaken to develop an energy-based time equivalent approach to obtain the fire resistance ratings (FRRs) of light gauge steel frame (LSF) walls exposed to realistic design fire curves.

Design/methodology/approach

The energy-based time equivalent method was developed based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of the standard fire time – temperature curve. The FRR predicted by the energy-based method for LSF wall configurations exposed to both rapid and prolonged fires were compared with those from fire design rules and finite element analyses (FEA).

Findings

The proposed energy method can be used to obtain the FRR of LSF walls in case of prolonged fires and cannot be used for rapid fires as the computed FRRs were higher than the results from FEA and fire design rules due to the influence of thermal bowing and its magnification effects at a high temperature gradient across the studs for rapid fires.

Originality/value

The energy-based time equivalent method was developed based on equal fire severity principles. Three different wall configurations were considered and exposed to both rapid and prolonged fires. The FRR obtained from the energy-based method were compared with fire design rules and FEA results to assess the use of the energy-based method to predict the FRR of LSF walls.

Details

Journal of Structural Fire Engineering, vol. 8 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 17 January 2022

Irindu Upasiri, Chaminda Konthesingha, Anura Nanayakkara, Keerthan Poologanathan, Gatheeshgar Perampalam and Dilini Perera

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel

Abstract

Purpose

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.

Design/methodology/approach

A Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.

Findings

Novel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.

Research limitations/implications

The developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.

Practical implications

LSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.

Originality/value

Limited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 April 2019

Mohammad Javad Kazemi, Shahabeddin Hatami, Abdolreza Zare and Ali Parvaneh

This paper aims to study the lateral behavior of cold-formed steel walls with K-shaped bracing by finite element modeling.

Abstract

Purpose

This paper aims to study the lateral behavior of cold-formed steel walls with K-shaped bracing by finite element modeling.

Design/methodology/approach

The braces which have the same section as those for studs and tracks are connected to the frame by screw connections. By pushover analysis, lateral performance of two frame categories, with different dimensions and bracing arrangements, is examined, and the force-displacement diagram and the ultimate strength of walls are extracted. Probable failure modes during lateral loading including distortional buckling of studs, buckling in braces and failure of connections are simulated in the numerical model, and some strengthening suggestions would be offered to prevent brittle failures and, therefore, to increase the lateral strength of the walls.

Findings

The strengthened walls are examined, and their seismic behavior is compared with the original walls. Finally, a parametric study is carried out to evaluate the effect of factors such as thickness of frame members, frame height and yield tension of members on lateral behavior of the shear walls.

Originality/value

In the present research, lateral strength and failure modes of nine types of cold-formed steel shear walls with different arrangements of K-shaped bracing are examined by non-linear finite element analysis, and a parametric study is carried out to extract the effect of the wall frame characteristics on the lateral behavior. Shear walls are classified into two series.

Details

World Journal of Engineering, vol. 16 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 9 October 2018

Oluwaseun Dosumu and Clinton Ohis Aigbavboa

This paper aims to investigate the level of awareness about, adoption of and willingness to adopt light steel (LS) for building projects. It also assessed the benefits, challenges…

Abstract

Purpose

This paper aims to investigate the level of awareness about, adoption of and willingness to adopt light steel (LS) for building projects. It also assessed the benefits, challenges and solutions to the challenges of adopting LS for building projects.

Design/methodology/approach

The quantitative (questionnaire) research method was used for the study. The research design was survey in nature. The whole-population cluster sampling technique was adopted. The clusters were the LS buildings from two (Western Cape and Gauteng) out of the eight provinces in South Africa. The respondents were the construction organizations that have executed LS building projects in the selected provinces. Hence, 56 firms filled and returned the questionnaire. Data analysis was done with frequency, mean scores, t-test and analysis of variance (normality of data distribution assumed).

Findings

Results indicated that, out of the 29 areas of application of LS identified in literature, respondents were aware of 11 areas, adopted LS for seven areas and were willing to adopt LS for six areas. Respondents also noted that 18 of the 25 identified benefits of LS were relevant to South Africa. Despite the benefits, few developers embrace it, it is a threat to suppliers’ and contractors’ businesses and it delays building approval due to low awareness.

Practical implication

The implication of the results is that there is low awareness about, adoption of and willingness to adopt LS for building projects in South Africa, and this may be due to the identified challenges. To boost the awareness about, adoption of and willingness to adopt LS, LS technologies need to be imported, LS warehouses should be provided in all cities and it must be ensured that LS building projects are cheaper than conventional buildings.

Originality/value

The value of the study is that the adoption of LS for building projects will improve the capacity of sustainable development.

Details

Journal of Engineering, Design and Technology, vol. 16 no. 5
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 14 July 2017

Mohamed Rusthi, Poologanathan Keerthan, Mahen Mahendran and Anthony Ariyanayagam

This research was aimed at investigating the fire performance of LSF wall systems by using 3-D heat transfer FE models of existing LSF wall system configurations.

Abstract

Purpose

This research was aimed at investigating the fire performance of LSF wall systems by using 3-D heat transfer FE models of existing LSF wall system configurations.

Design/methodology/approach

This research was focused on investigating the fire performance of LSF wall systems by using 3-D heat transfer finite element models of existing LSF wall system configurations. The analysis results were validated by using the available fire test results of five different LSF wall configurations.

Findings

The validated finite element models were used to conduct a parametric study on a range of non-load bearing and load bearing LSF wall configurations to predict their fire resistance levels (FRLs) for varying load ratios.

Originality/value

Fire performance of LSF wall systems with different configurations can be understood by performing full-scale fire tests. However, these full-scale fire tests are time consuming, labour intensive and expensive. On the other hand, finite element analysis (FEA) provides a simple method of investigating the fire performance of LSF wall systems to understand their thermal-mechanical behaviour. Recent numerical research studies have focused on investigating the fire performances of LSF wall systems by using finite element (FE) models. Most of these FE models were developed based on 2-D FE platform capable of performing either heat transfer or structural analysis separately. Therefore, this paper presents the details of a 3-D FEA methodology to develop the capabilities to perform fully-coupled thermal-mechanical analyses of LSF walls exposed to fire in future.

Details

Journal of Structural Fire Engineering, vol. 8 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 19 August 2014

Poologanathan Keerthan and Mahen Mahendran

Cold-formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design…

Abstract

Cold-formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.

Article
Publication date: 5 April 2018

Ali Tighnavard Balasbaneh, Abdul Kadir Bin Marsono and Emad Kasra Kermanshahi

The purpose of this study is to describe life cycle cost (LCC) and life cycle assessment (LCA) evaluation for single story building house in Malaysia. Two objective functions…

839

Abstract

Purpose

The purpose of this study is to describe life cycle cost (LCC) and life cycle assessment (LCA) evaluation for single story building house in Malaysia. Two objective functions, namely, LCA and LCC, were evaluated for each design and a total of 20 alternatives were analyzed. Two wall schemes that have been adopted from two different recent studies toward mitigation of climate change require clarification in both life cycle objectives.

Design/methodology/approach

For this strategic life cycle assessment, Simapro 8.3 tool has been chosen over a 50-year life span. LCC analysis was also used to determine not only the most energy-efficient strategy, but also the most economically feasible one. A present value (PV)-based economic analysis takes LCC into account.

Findings

The results will appear in present value and LC carbon footprint saving, both individually and in combination with each other. Result of life cycle management shows that timber wall−wooden post and beam covered by steel stud (W5) and wood truss with concrete roof tiles (R1) released less carbon emission to atmosphere and have lower life cycle cost over their life span. W5R1 releases 35 per cent less CO2 emission than the second best choice and costs 25 per cent less.

Originality/value

The indicator assessed was global warming, and as the focus was on GHG emissions, the focus of this study was mainly in the context of Malaysian construction, although the principles apply universally. The result would support the adoption of sustainable building for building sector.

Details

Construction Innovation, vol. 18 no. 3
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 1 October 1964

TO say that the Twenty‐fourth S.B.A.C. Show was an unqualified success is perhaps to gild the lily. True there were disappointments— the delay which kept the TSR‐2 on the ground…

165

Abstract

TO say that the Twenty‐fourth S.B.A.C. Show was an unqualified success is perhaps to gild the lily. True there were disappointments— the delay which kept the TSR‐2 on the ground until well after the Show being one—but on the whole the British industry was well pleased with Farnborough week and if future sales could be related to the number of visitors then the order books would be full for many years to come. The total attendance at the Show was well over 400,000—this figure including just under 300,000 members of the public who paid to enter on the last three days of the Show. Those who argued in favour of allowing a two‐year interval between the 1962 Show and this one seem to be fully vindicated, for these attendance figures are an all‐time record. This augurs well for the future for it would appear that potential customers from overseas are still anxious to attend the Farnborough Show, while the public attendance figures indicate that Britain is still air‐minded to a very healthy degree. It is difficult to pick out any one feature or even one aircraft as being really outstanding at Farnborough, but certainly the range of rear‐engined civil jets (HS. 125, BAC One‐Eleven, Trident and VCIQ) served as a re‐minder that British aeronautical engineering prowess is without parallel, while the number of rotorcraft to be seen in the flying display empha‐sized the growing importance of the helicopter in both civil and military operations. As far as the value of Farnborough is concerned, it is certainly a most useful shop window for British aerospace products, and if few new orders are actually received at Farnborough, a very large number are announced— as our ’Orders and Contracts' column on page 332 bears witness. It is not possible to cover every exhibit displayed at the Farnborough Show but the following report describes a wide cross‐section beginning with the exhibits of the major airframe and engine companies.

Details

Aircraft Engineering and Aerospace Technology, vol. 36 no. 10
Type: Research Article
ISSN: 0002-2667

Article
Publication date: 5 May 2023

Rakesh Sai Kumar Mandala and R. Ramesh Nayaka

This paper aims to identify modern construction techniques for affordable housing, such as prefabrication and interlocking systems, that can save time and cost while also…

Abstract

Purpose

This paper aims to identify modern construction techniques for affordable housing, such as prefabrication and interlocking systems, that can save time and cost while also providing long-term sustainable benefits that are desperately needed in today's construction industry.

Design/methodology/approach

The need for housing is growing worldwide, but traditional construction cannot cater to the demand due to insufficient time. There should be some paradigm shift in the construction industry to supply housing to society. This paper presented a state-of-the-art review of modern construction techniques practiced worldwide and their advantages in affordable housing construction by conducting a systematic literature review and applying the backward snowball technique. The paper reviews modern prefabrication techniques and interlocking systems such as modular construction, formwork systems, light gauge steel/cold form steel construction and sandwich panel construction, which have been globally well practiced. It was understood from the overview that modular construction, including modular steel construction and precast concrete construction, could reduce time and costs efficiently. Further enhancement in the quality was also noticed. Besides, it was observed that light gauge steel construction is a modern phase of steel that eases construction execution efficiently. Modern formwork systems such as Mivan (Aluminium Formwork) have been reported for their minimum construction time, which leads to faster construction than traditional formwork. However, the cost is subjected to the repetitions of the formwork. An interlocking system is an innovative approach to construction that uses bricks made of sustainable materials such as earth that conserve time and cost.

Findings

The study finds that the prefabrication techniques and interlocking system have a lot of unique attributes that can enable the modern construction sector to flourish. The study summarizes modern construction techniques that can save time and cost, enhancing the sustainability of construction practices, which is the need of the Indian construction industry in particular.

Research limitations/implications

This study is limited to identifying specific modern construction techniques for time and cost savings, lean concepts and sustainability which are being practiced worldwide.

Practical implications

Modern formwork systems such as Mivan (Aluminium Formwork) have been reported for their minimum construction time which leads to faster construction than traditional formwork.

Social implications

The need for housing is growing rapidly all over the world, but traditional construction cannot cater to the need due to insufficient time. There should be some paradigm shift in the construction industry to supply housing to society.

Originality/value

This study is unique in identifying specific modern construction techniques for time and cost savings, lean concepts and sustainability which are being practiced worldwide.

Details

Construction Innovation , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1471-4175