Search results

1 – 10 of over 8000
Article
Publication date: 29 March 2024

Aminuddin Suhaimi, Izni Syahrizal Ibrahim and Mariyana Aida Ab Kadir

This review paper seeks to enhance knowledge of how pre-loading affects reinforced concrete (RC) beams under fire. It investigates key factors like deflection and load capacity to…

Abstract

Purpose

This review paper seeks to enhance knowledge of how pre-loading affects reinforced concrete (RC) beams under fire. It investigates key factors like deflection and load capacity to understand pre-loading's role in replicating RC beams' actual responses to fire, aiming to improve fire testing protocols and structural fire engineering design.

Design/methodology/approach

This review systematically aggregates data from existing literature on the fire response of RC beams, comparing scenarios with (WP) and without pre-loading (WOP). Through statistical tools like the two-tailed t-test and Mann–Whitney U-test, it assesses deflection extremes. The study further examines structural responses, including flexural and shear behavior, ultimate load capacity, post-yield behavior, stiffness degradation and failure modes. The approach concludes with a statistical forecast of ideal pre-load levels to elevate experimental precision and enhance fire safety standards.

Findings

The review concludes that pre-loading profoundly affects the fire response of RC beams, suggesting a 35%–65% structural capacity range for realistic simulations. The review also recommended the initial crack load as an alternative metric for determining the pre-loading impact. Crucially, it highlights that pre-loading not only influences the fire response but also significantly alters the overall structural behavior of the RC beams.

Originality/value

The review advances structural fire engineering with an in-depth analysis of pre-loading's impact on RC beams during fire exposure, establishing a validated pre-load range through thorough statistical analysis and examination of previous research. It refines experimental methodologies and structural design accuracy, ultimately bolstering fire safety protocols.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 29 March 2018

Osama (Sam) Salem

In fire condition, the limiting temperature of a restrained steel beam depends on a few parameters, e.g. temperature distributions along and across the beam, beam’s load ratio and…

Abstract

Purpose

In fire condition, the limiting temperature of a restrained steel beam depends on a few parameters, e.g. temperature distributions along and across the beam, beam’s load ratio and span length. The purpose of this study is to investigate the structural fire behaviour of axially restrained steel beams under different beam’s load ratios, taking into consideration the effect of the beam’s end connections configuration.

Design/methodology/approach

A three-dimensional finite element (FE) computer model has been developed to simulate the structural fire behaviour of axially restrained steel beams and their end connections. After successfully validating the developed model against the outcomes of the available large-size fire resistance experiments, the FE model has been used in a parametric study to investigate the beam’s load ratio effect on the behaviour of the axially restrained steel beams and their end connections.

Findings

The parametric study showed that increasing the beam loading level significantly increased the beam deflections at elevated temperatures; where, increasing the beam’s load ratio from 0.5 to 0.9 reduced the beam fire resistance by about 100 s. In contrast, decreasing the beam’s load ratio from 0.5 to 0.3 allowed the beam to easily achieve a 30-min fire resistance rating with no fire protection applied.

Originality/value

Experimental parametric studies are difficult to control in a laboratory setting and are also expensive and time consuming. Therefore, the reasonable accuracy of the validated FE model in reproducing the experimental fire behaviour of steel beams and their end connections makes it a very useful tool for both numerical and analytical studies.

Details

Journal of Structural Fire Engineering, vol. 9 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 4 September 2019

Richard Walls, Celeste Viljoen and Hennie de Clercq

This paper aims to provide a parametric investigation into the behaviour of steel, concrete and composite beams exposed to fire. This investigation gives insight into the…

Abstract

Purpose

This paper aims to provide a parametric investigation into the behaviour of steel, concrete and composite beams exposed to fire. This investigation gives insight into the structural behaviour of elements experiencing thermal and mechanical loading illustrating reasons for observed global structural behaviour, and identifying how selected design parameters influence results obtained. Non-linear heating/thermal bowing behaviour is specifically considered.

Design/methodology/approach

Cross-sectional stresses and strains, resultant thermal forces, bending stiffness, axial stiffness and deflections are plotted for beams subjected to different fire regimes or input values. The impact of changes in input parameters on beam section properties is illustrated. Unusual structural responses, localised effects and general trends are identified in relation to variations in thermal gradients, concrete tensile capacity, standard fire exposure time and the assumed concrete flange widths of composite beams.

Findings

Stress-strain plots highlighting cross-sectional structural behaviour, trends in beam properties and the influence of design parameters are provided. Some counter-intuitive behaviour is explained, such as increased member stiffness being offset by increased thermal effects, leading to this parameter having negligible impact on global behaviour but a significant effect on local stresses and strains. Increased concrete strengths may lead to increased thermal deformations, whilst the inclusion of concrete tensile capacity typically has a minimal influence.

Research limitations/implications

The research focusses on cross-sectional properties, although results generated illustrate how global behaviour is affected.

Practical implications

Design engineers are made aware of how selected input values influence predicted structural response. Also, localised stress and strain behaviour relative to imposed loads and thermal effects can be identified.

Originality/value

This paper provides novel insight into the (sometimes counter-intuitive) behaviour of beams exposed to fire, highlighting trends and the influence of important input parameters on predicted response.

Details

Journal of Structural Fire Engineering, vol. 11 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 August 2022

Ilias Thanasoulas, Dan Lauridsen, Bjarne Paulsen Husted and Luisa Giuliani

The purpose of this study is to contribute toward providing the main aspects of numerical modeling the fire behavior of steel structures with finite elements (FEs). The…

Abstract

Purpose

The purpose of this study is to contribute toward providing the main aspects of numerical modeling the fire behavior of steel structures with finite elements (FEs). The application of the method is presented for a characteristic case study comprising the series of large-scale fire door tests performed at the Danish Institute of Fire and Security Technology.

Design/methodology/approach

Following a general overview of current practices in structural fire engineering, the FE method is used to simulate the large-scale furnace tests on steel doors with thermal insulation exposed to standard fire.

Findings

The FE model is compared with the fire test results, achieving good agreement in terms of developed temperatures and deformations.

Originality/value

The numerical methodology and recommended practices for modeling the fire behavior of steel structures are presented, which can be used in support of performance-based fire design standards.

Details

Journal of Structural Fire Engineering, vol. 14 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 June 2019

Karim Al Khatib, Elie Hantouche and Mohammed Ali Morovat

This study aims to investigate the thermal creep behavior of steel frame assemblies with shear tab connections subjected to transient-state fire temperatures. Different key…

Abstract

Purpose

This study aims to investigate the thermal creep behavior of steel frame assemblies with shear tab connections subjected to transient-state fire temperatures. Different key parameters are investigated to study their effect on the global response of the steel frames in fire.

Design/methodology/approach

Finite element (FE) models of connection assemblies are first analyzed using Abaqus under transient-state temperature conditions and validated against experimental work available in the literature. Upon acquiring the validated conditions, parametric studies are carried out to study the effect of key geometric and heating parameters on the overall response of the frame assembly to fire temperatures. Thermal creep material is also incorporated in the analyses through a user-defined subroutine, and a comparison between including and excluding creep material is illustrated to show the effect of thermal creep on the structural behavior.

Findings

The results reported herein indicate that having a rigid column increases the thermal-induced axial forces, thus increasing the development of thermal creep strains. Slow heating rates can cause axial stress relaxation in the restrained beam and increase the mid-span deflection and consequently the development of beam catenary action. The results also show that reaching higher initial cooling temperatures and having longer cooling phase durations result in more tensile forces at the end of the cooling phase.

Originality/value

Previous studies were limited to isolated steel connections under steady-state conditions. This study investigates the creep behavior of shear tab connection assemblies under transient-state conditions of fire when creep effects are explicitly considered. This can provide a rational and realistic assessment of the steel behavior in fire events.

Details

Journal of Structural Fire Engineering, vol. 10 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 June 2017

Chrysanthos Maraveas, Zacharias Fasoulakis and Konstantinos Daniel Tsavdaridis

This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural

Abstract

Purpose

This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural normal steel (hot-rolled and cold-formed) and high-strength bolts after exposure to elevated temperatures. Information on stainless steel, cast iron and wrought iron is also presented.

Design/methodology/approach

Because of the complexity of the issue, an elaborate presentation of the mechanical properties influencing factors is followed. Subsequently, a wide range of experimental studies is extensively reviewed in the literature while simplified equations for determining the post-fire mechanical properties are proposed, following appropriate categorization. Moreover, the reinstatement survey is also comprehensively described.

Findings

Useful conclusions are drawn for the safe reuse of the structural elements and connection components. According to the parametric investigation of the aforementioned data, it can be safely concluded that the most common scenario of buildings after fire events, i.e. apart from excessively distorted structures, implies considerable remaining capacity of the structure, highlighting that subsequent demolition should not be the case, especially regarding critical infrastructure and buildings.

Originality/value

The stability of the structure as a whole is addressed, with aim to establish specific guidelines and code provisions for the correct appraisal and rehabilitation of fire damaged structures.

Details

Journal of Structural Fire Engineering, vol. 8 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 4 October 2019

Mustesin Ali Khan, Liming Jiang, Katherine Ann Cashell and Asif Usmani

Perforated composite beams are an increasingly popular choice in the construction of buildings because they can provide a structurally and materially efficient design solution…

Abstract

Purpose

Perforated composite beams are an increasingly popular choice in the construction of buildings because they can provide a structurally and materially efficient design solution while also facilitating the passage of services. The purpose of this paper is to examine the behaviour of restrained perforated beams, which act compositely with a profiled slab and are exposed to fire. The effect of surrounding structure on the composite perforated beam is incorporated in this study using a virtual hybrid simulation framework. The developed framework could also be used to analyse other structural components in fire.

Design/methodology/approach

A finite element model is developed using OpenSees and OpenFresco using a virtual hybrid simulation technique, and the accuracy of the model is validated using available fire test data. The validated model is used to investigate some of the most salient parameters such as the degree of axial and rotational restraint, arrangement of the openings and different types of fire on the overall fire behaviour of composite perforated beams.

Findings

It is shown that both axial and rotational restraint have a considerable effect on time-displacement behaviour and the fire performance of the composite perforated beam. It is observed that the rate of heating and the consequent development of elevated temperature in the section have a significant effect on the fire behaviour of composite perforated beams.

Originality/value

The paper will improve the knowledge of readers about modelling the whole system behaviour in structural fire engineering and the presented approach could also be used for analysing different types of structural components in fire conditions.

Details

Journal of Structural Fire Engineering, vol. 11 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 23 January 2019

Mayank Shrivastava, Anthony Abu, Rajesh Dhakal and Peter Moss

This paper aims to describe current trends in probabilistic structural fire engineering and provides a comprehensive summary of the state-of-the-art of performance-based structural

Abstract

Purpose

This paper aims to describe current trends in probabilistic structural fire engineering and provides a comprehensive summary of the state-of-the-art of performance-based structural fire engineering (PSFE).

Design/methodology/approach

PSFE has been introduced to overcome the limitations of current conventional design approaches used for the design of fire-exposed structures, which investigate assumed worst-case fire scenarios and include multiple thermal and structural analyses. PSFE permits buildings to be designed in relation to a level of life safety or economic loss that may occur in future fire events with the help of a probabilistic approach.

Findings

This paper brings together existing research on various sources of uncertainty in probabilistic structural fire engineering, such as elements affecting post-flashover fire development, material properties, fire models, fire severity, analysis methods and structural reliability.

Originality/value

Prediction of economic loss would depend on the extent of damage, which is further dependent on the structural response. The representative prediction of structural behaviour would depend on the precise quantification of the fire hazard. The incorporation of major uncertainty sources in probabilistic structural fire engineering is explained, and the detailed description of a pioneering analysis method called incremental fire analysis is presented.

Details

Journal of Structural Fire Engineering, vol. 10 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 8 July 2019

Ahmed Allam, Ayman Nassif and Ali Nadjai

This paper aims to investigate computationally and analytically how different levels of restraint from surrounding structure, via catenary action in beams, affect the survival of…

Abstract

Purpose

This paper aims to investigate computationally and analytically how different levels of restraint from surrounding structure, via catenary action in beams, affect the survival of steel framed structures in fire. This study focuses on examining the mid-span deflection and the tensile axial force of a non-composite heated steel beam at large deflection that is induced by the catenary action during exposure to fires. The study also considers the effect of the axial horizontal restraints, load-ratio, beam temperature gradient and the span/depth ratio. It was found that these factors influence the heated steel beam within steel construction and its catenary action at large deflection. The study suggests that this may help the beam to hang to the surrounding cold structure and delay the run-away deflection when the tensile axial force of the beam has been overcome.

Design/methodology/approach

This paper is part one of the parametric study and discusses both the effect of the axial horizontal restraints and load-ratio on the heated steel-beam. Reliance on the prescriptive standard fire solutions may lead to an unpredicted behaviour of the structure members if the impact of potential real fires is not considered.

Findings

Variation of the horizontal end-restraint level has a major effect on the behaviour of the beam at high deflection, and the loading on a beam at large displacement can be carried effectively by catenary behaviour. An increase of axial horizontal stiffness helps the catenary action to prevent run-away at lower deflections. The studies also investigated the influence of varying the load ratio on the behaviour of the heated beam at large deflection and how it affects the efficacy of the catenary action. The study suggests that care should be taken when selecting the load ratio to be used in the design.

Originality/value

In a recent work, the large deflection behaviours of axially restrained corrugated web steel beam (CWSB) at elevated temperatures were investigated using a finite element method (Wang et al., 2014). Parameters that greatly affected behaviours of CWSB at elevated temperatures were the load ratio, the axial restraint stiffness ratio and the span–depth ratio. Other works included numerical studies on large deflection behaviours of restrained castellated steel beams in a fire where the impact of the catenary action is considered (Wang, 2002). The impact of the induced axial forces in the steel beam during cooling stage of a fire when the beam temperature decreases, if thermal shortening of the beam is restrained, large tensile forces may be induced in the beam (Wang, 2005; Allam et al., 2002). A performance-based approach is developed for assessing the fire resistance of restrained beams. The approach is based on equilibrium and compatibility principles, takes into consideration the influence of many factors, including fire scenario, end restraints, thermal gradient, load level and failure criteria, in evaluating fire resistance (Dwaikat and Kodur, 2011; Allam et al., 1998).

Details

Journal of Structural Fire Engineering, vol. 10 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 21 December 2023

Nagat Zalhaf, Mariam Ghazy, Metwali Abdelatty and Mohamed Hamed Zakaria

Even though it is widely used, reinforced concrete (RC) is susceptible to damage from various environmental factors. The hazard of a fire attack is particularly severe because it…

Abstract

Purpose

Even though it is widely used, reinforced concrete (RC) is susceptible to damage from various environmental factors. The hazard of a fire attack is particularly severe because it may cause the whole structure to collapse. Furthermore, repairing and strengthening existing structures with high-performance concrete (HPC) has become essential from both technical and financial points of view. In particular, studying the postfire behavior of HPC with normal strength concrete substrate requires experimental and numerical investigations. Accordingly, this study aims to numerically investigate the post-fire behavior of reinforced composite RC slabs.

Design/methodology/approach

Consequently, in this study, a numerical analysis was carried out to ascertain the flexural behavior of simply supported RC slabs strengthened with HPC and exposed to a particularly high temperature of 600°C for 2 h. This behavior was investigated and analyzed in the presence of a number of parameters, such as HPC types (fiber-reinforced, 0.5% steel, polypropylene fibers [PPF], hybrid fibers), strengthening side (tension or compression), strengthening layer thickness, slab thickness, boundary conditions, reinforcement ratio and yield strength of reinforcement.

Findings

The results showed that traction-separation and full-bond models can achieve accuracy compared with experimental results. Also, the fiber type significantly affects the postfire performance of RC slab strengthened with HPC, where the inclusion of hybrid fiber recorded the highest ultimate load. While adding PPF to HPC showed a rapid decrease in the load-deflection curve after reaching the ultimate load.

Originality/value

The proposed model accurately predicted the thermomechanical behavior of RC slabs strengthened with HPC after being exposed to the fire regarding load-deflection response, crack pattern and failure mode. Moreover, the considered independent parametric variables significantly affect the composite slabs’ behavior.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 10 of over 8000