Search results

1 – 10 of 138
Article
Publication date: 26 May 2021

Sachin Negi, Shiru Sharma and Neeraj Sharma

The purpose of this paper is to present gait analysis for five different terrains: level ground, ramp ascent, ramp descent, stair ascent and stair descent.

Abstract

Purpose

The purpose of this paper is to present gait analysis for five different terrains: level ground, ramp ascent, ramp descent, stair ascent and stair descent.

Design/methodology/approach

Gait analysis has been carried out using a combination of the following sensors: force-sensitive resistor (FSR) sensors fabricated in foot insole to sense foot pressure, a gyroscopic sensor to detect the angular velocity of the shank and MyoWare electromyographic muscle sensors to detect muscle’s activities. All these sensors were integrated around the Arduino nano controller board for signal acquisition and conditioning purposes. In the present scheme, the muscle activities were obtained from the tibialis anterior and medial gastrocnemius muscles using electromyography (EMG) electrodes, and the acquired EMG signals were correlated with the simultaneously attained signals from the FSR and gyroscope sensors. The nRF24L01+ transceivers were used to transfer the acquired data wirelessly to the computer for further analysis. For the acquisition of sensor data, a Python-based graphical user interface has been designed to analyze and display the processed data. In the present paper, the authors got motivated to design and develop a reliable real-time gait phase detection technique that can be used later in designing a control scheme for the powered ankle-foot prosthesis.

Findings

The effectiveness of the gait phase detection was obtained in an open environment. Both off-line and real-time gait events and gait phase detections were accomplished for the FSR and gyroscopic sensors. Both sensors showed their usefulness for detecting the gait events in real-time, i.e. within 10 ms. The heuristic rules and a zero-crossing based-algorithm for the shank angular rate correctly identified all the gait events for the locomotion in all five terrains.

Practical implications

This study leads to an understanding of human gait analysis for different types of terrains. A real-time standalone system has been designed and realized, which may find application in the design and development of ankle-foot prosthesis having real-time control feature for the above five terrains.

Originality/value

The noise-free data from three sensors were collected in the same time frame from both legs using a wireless sensor network between two transmitters and a single receiver. Unlike the data collection using a treadmill in a laboratory environment, this setup is useful for gait analysis in an open environment for different terrains.

Article
Publication date: 21 September 2015

Hongyu Zhao, Zhelong Wang, Qin Gao, Mohammad Mehedi Hassan and Abdulhameed Alelaiwi

The purpose of this paper is to develop an online smoothing zero-velocity-update (ZUPT) method that helps achieve smooth estimation of human foot motion for the ZUPT-aided…

Abstract

Purpose

The purpose of this paper is to develop an online smoothing zero-velocity-update (ZUPT) method that helps achieve smooth estimation of human foot motion for the ZUPT-aided inertial pedestrian navigation system.

Design/methodology/approach

The smoothing ZUPT is based on a Rauch–Tung–Striebel (RTS) smoother, using a six-state Kalman filter (KF) as the forward filter. The KF acts as an indirect filter, which allows the sensor measurement error and position error to be excluded from the error state vector, so as to reduce the modeling error and computational cost. A threshold-based strategy is exploited to verify the detected ZUPT periods, with the threshold parameter determined by a clustering algorithm. A quantitative index is proposed to give a smoothness estimate of the position data.

Findings

Experimental results show that the proposed method can improve the smoothness, robustness, efficiency and accuracy of pedestrian navigation.

Research limitations/implications

Because of the chosen smoothing algorithm, a delay no longer than one gait cycle is introduced. Therefore, the proposed method is suitable for applications with soft real-time constraints.

Practical implications

The paper includes implications for the smooth estimation of most types of pedal locomotion that are achieved by legged motion, by using a sole foot-mounted commercial-grade inertial sensor.

Originality/value

This paper helps realize smooth transitions between swing and stance phases, helps enable continuous correction of navigation errors during the whole gait cycle, helps achieve robust detection of gait phases and, more importantly, requires lower computational cost.

Details

Sensor Review, vol. 35 no. 4
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 18 January 2013

Zhelong Wang, Sen Qiu, Zhongkai Cao and Ming Jiang

Due to the complex mechanism during walking, human gait takes plenty of information reflecting human motion. The method of quantitative measurement of gait makes a profound…

Abstract

Purpose

Due to the complex mechanism during walking, human gait takes plenty of information reflecting human motion. The method of quantitative measurement of gait makes a profound influence in many fields, such as clinical medicine, biped robot control strategy and so on. The purpose of this paper is to present a gait analysis system based on inertial measurement unit (IMU) and combined with body sensor network (BSN).

Design/methodology/approach

The authors placed two wireless inertial nodes on the left and right ankles, so that the acceleration and angular velocity could be obtained from both sides at the same time. By using the kinematical model of the human gait, many methods such as time series analysis, pattern recognition and numerical analysis, are introduced to fuse the inertial data and estimate the sagittal gait parameters.

Findings

The gait parameters evaluation gains a practical precision, especially in the gait phase detection and the process of how the two feet cooperate with each other has been analyzed to learn about the mechanism of biped walking.

Research limitations/implications

The gait analysis procedure is off line, so that the system ensures sampling at a high rate.

Originality/value

This gait analysis system can be utilized to measure quantitative gait parameters. Further, the coordination of dual gait pattern is presented. Last but not least, the system can also be put into capturing and analyzing the motion of other parts of the body.

Details

Sensor Review, vol. 33 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 5 August 2020

Abanah Shirley J., Esther Florence Sundarsingh, Saraswathi V., Sankareshwari S. and Sona S.

Fall detection is a primary necessity for elderly people with medically tested nervous problems. This paper aims important to detect fall and prevent fatal injuries and untreated…

Abstract

Purpose

Fall detection is a primary necessity for elderly people with medically tested nervous problems. This paper aims important to detect fall and prevent fatal injuries and untreated attention for long hours.

Design/methodology/approach

The project is focused on developing a smart shoe with force-sensitive resistors placed at plantar pressure points to detect fall. This could draw immediate medical attention to the patient. The device is developed using sensors, microcontroller and accelerometer integrated into a compact module. A rule-based detection algorithm helps in transmitting the alert to an Internet of Things device when a fall is detected.

Findings

Based on the pressure applied, there is a change in resistive value of force sensitivity resistor. When it reaches the threshold value, fall gets detected and alert gets triggered through telegram bot with latitude and longitude details of the location.

Originality/value

The challenge in developing this device is to make it wearable reducing the overall hardware complexity. The entire module placed inside the sole of the shoe avoids inconvenience to the patients.

Details

Circuit World, vol. 47 no. 4
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 24 August 2021

Sachin Negi, Ujjwal Sagar, Vijay Kumar Nautiyal and Neeraj Sharma

This paper aims to design and analyze a controlled magnetorheological damper-based ankle-foot prosthesis prototype.

Abstract

Purpose

This paper aims to design and analyze a controlled magnetorheological damper-based ankle-foot prosthesis prototype.

Design/methodology/approach

The ankle-foot prostheses prototype is proposed using the lightweight three dimensional (3 D)-printed parts, MR damper and digital servomotor. Initially, the computer-aided design (CAD) model of the prosthetic foot, leaf spring, retention spring and the various connecting parts required to connect the pylon and damper actuator assemblies are designed using CAD software. Later, the fused deposition modeling 3 D printer-based technique prints a prosthetic foot and other connecting parts using Acrylonitrile Butadiene Styrene filament. The prototype consists of two control parts: the first part controls the MR actuator that absorbs the impacts during walking. The second part is the control of the electric actuator intended to generate the dorsiflexion and plantar flexion movements. Finally, the prototype is tested on a transtibial amputee under the supervision of a prosthetist.

Findings

The ANalysis SYStems software-based analysis has shown that the prosthetic foot has a factor of safety values between 4.7 and 8.7 for heel strike, mid-swing and toe-off; hence, it is safe from mechanical failure. The designed MR damper-based ankle-foot prosthesis prototype is tested on an amputee for a level-ground walk; he felt comfortable compared to his passive prosthesis.

Originality/value

The design of an MR damper-based prosthesis prototype offers a better dynamic range for locomotion than passive prostheses. It reduces the injuries and provides relief to the transtibial amputees.

Details

Industrial Robot: the international journal of robotics research and application, vol. 49 no. 2
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 7 May 2019

Hansong Wang, Canjun Yang, Wei Yang, Meiying Deng, Zhangyi Ma and Qianxiao Wei

Most current lower extremity exoskeletons emphasize assistance for walking rather than stability. The purpose of this paper is to propose a rehabilitation gait based on the…

Abstract

Purpose

Most current lower extremity exoskeletons emphasize assistance for walking rather than stability. The purpose of this paper is to propose a rehabilitation gait based on the transfer of gravity center to improve the balance of exoskeleton rehabilitation training of the hemiplegic patients in the frontal plane, reducing the dependence on crutches/walking frames.

Design/methodology/approach

The real-time and predictable instability factors of human and exoskeleton system (HES) are analyzed. Inspired by the walking balance strategy of the blind, a rehabilitation gait based on the transfer of gravity center is proposed and studied by modeling and experimental test and is finally applied to the prototype – Zhejiang University lower extremity exoskeleton (ZJULEEX) – to verify its feasibility.

Findings

At least three real-time and predictable factors cause the instability of HES, and the factor of lateral tilt caused by gravity should be focused in the balance control of frontal plane. With the proposed gait, the hip height of stepping leg of HES does not reduce obviously even when the crutches do not work, which can improve the balance of HES.

Research limitations/implications

However, the rehabilitation gait control needs to be more complete and intelligent to response to other types of perturbations to further improve the balance of HES. In addition, more clinical trials should be conducted to evaluate the effect of the proposed gait.

Social implications

May bring happiness to the rehabilitation of patients with hemiplegia.

Originality/value

The rehabilitation gait based on the transfer of gravity center to improve the balance of HES is first proposed and applied to HES.

Details

Industrial Robot: the international journal of robotics research and application, vol. 46 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 7 August 2017

Du-Xin Liu, Xinyu Wu, Wenbin Du, Can Wang, Chunjie Chen and Tiantian Xu

The purpose of this paper is to model and predict suitable gait trajectories of lower-limb exoskeleton for wearer during rehabilitation walking. Lower-limb exoskeleton is widely…

Abstract

Purpose

The purpose of this paper is to model and predict suitable gait trajectories of lower-limb exoskeleton for wearer during rehabilitation walking. Lower-limb exoskeleton is widely used for assisting walk in rehabilitation field. One key problem for exoskeleton control is to model and predict suitable gait trajectories for wearer.

Design/methodology/approach

In this paper, the authors propose a Deep Spatial-Temporal Model (DSTM) for generating knee joint trajectory of lower-limb exoskeleton, which first leverages Long-Short Term Memory framework to learn the inherent spatial-temporal correlations of gait features.

Findings

With DSTM, the pathological knee joint trajectories can be predicted based on subject’s other joints. The energy expenditure is adopted for verifying the effectiveness of new recovery gait pattern by monitoring dynamic heart rate. The experimental results demonstrate that the subjects have less energy expenditure in new recovery gait pattern than in others’ normal gait patterns, which also means the new recovery gait is more suitable for subject.

Originality/value

Long-Short Term Memory framework is first used for modeling rehabilitation gait, and the deep spatial–temporal relationships between joints of gait data can obtained successfully.

Details

Assembly Automation, vol. 37 no. 3
Type: Research Article
ISSN: 0144-5154

Keywords

Article
Publication date: 21 August 2009

Joseph Hitt, Thomas Sugar, Matthew Holgate, Ryan Bellman and Kevin Hollander

The purpose of this paper is to describe a project which seeks to develop a new generation of powered prostheses based on lightweight, uniquely tuned, energy‐storing elastic…

1936

Abstract

Purpose

The purpose of this paper is to describe a project which seeks to develop a new generation of powered prostheses based on lightweight, uniquely tuned, energy‐storing elastic elements in series with optimal actuator systems that will significantly reduce the peak power requirement of the motor and the total system energy requirement while providing the amputee 100 percent of required “push‐off” power and ankle sagittal plane range‐of‐motion comparable to able‐bodied gait.

Design/methodology/approach

This paper presents the design, power, and energy‐efficiency analyses, and the results of a five‐month trial with one trans‐tibial amputee subject as part of the first phase of the Spring Ankle with Regenerative Kinetics project.

Findings

The data show that by leveraging uniquely tuned springs and transmission mechanisms, motor power is easily amplified more than four fold and the electric energy requirement is cut in half compared with traditional approaches.

Originality/value

This paper describes an energy efficient, powered transtibial prosthesis currently unavailable commercially. Motor power and energy requirements are reduced with use of a unique design that employs regenerative kinetics.

Details

Industrial Robot: An International Journal, vol. 36 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 23 December 2015

Ming Gui Tan, Yean Chun Tea, Jee-Hou Ho, Hui-Ting Goh, Hoon Kiat Ng and Ing Kong

Quantitative gait analysis is an important research area to enable physiotherapist to perform systematic studies and health diagnosis of the lower extremity of patients throughout…

Abstract

Quantitative gait analysis is an important research area to enable physiotherapist to perform systematic studies and health diagnosis of the lower extremity of patients throughout the rehabilitation. The quantitative measurement of ambulatory gait can be performed by using convenient and economical wearable sensors outside specialized motion laboratories. In this paper, a sensor system consisting of three tri-axial accelerometers, two flex sensors and four force sensors was developed. Subject testing were carried out to obtain temporal and spatial gait parameters. The performance of the sensor suite is compared to results from camera videos analysed by Kinovea motion tracking software.

Details

World Journal of Engineering, vol. 12 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 14 January 2022

Xiang Li, Keyi Wang, Yan Lin Wang and Kui Cheng Wang

Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture…

Abstract

Purpose

Plantar force is the interface pressure existing between the foot plantar surface and the shoe sole during static or dynamic gait. Plantar force derived from gait and posture plays a critical role for rehabilitation, footwear design, clinical diagnostics and sports activities, and so on. This paper aims to review plantar force measurement technologies based on piezoelectric materials, which can make the reader understand preliminary works systematically and provide convenience for researchers to further study.

Design/methodology/approach

The review introduces working principle of piezoelectric sensor, structures and hardware design of plantar force measurement systems based on piezoelectric materials. The structures of sensors in plantar force measurement systems can be divided into four kinds, including monolayered sensor, multilayered sensor, tri-axial sensor and other sensor. The previous studies about plantar force measurement system based on piezoelectric technology are reviewed in detail, and their characteristics and performances are compared.

Findings

A good deal of measurement technologies have been studied by researchers to detect and analyze the plantar force. Among these measurement technologies, taking advantage of easy fabrication and high sensitivity, piezoelectric sensor is an ideal candidate sensing element. However, the number and arrangement of the sensors will influence the characteristics and performances of plantar force measurement systems. Therefore, it is necessary to further study plantar force measurement system for better performances.

Originality/value

So far, many plantar force measurement systems have been proposed, and several reviews already introduced plantar force measurement systems in the aspect of types of pressure sensors, experimental setups for foot pressure measurement analysis and the technologies used in plantar shear stress measurements. However, this paper reviews plantar force measurement systems based on piezoelectric materials. The structures of piezoelectric sensors in the measurement systems are discussed. Hardware design applied to measurement system is summarized. Moreover, the main point of further study is presented in this paper.

1 – 10 of 138