Search results

1 – 10 of 19
Article
Publication date: 5 July 2024

Majid Monajjemi and Fatemeh Mollaamin

Early prediction of any type of cancer is important for the treatment of this type of disease, therefore, our target to evaluate whether monitoring early changes in plasma human…

Abstract

Purpose

Early prediction of any type of cancer is important for the treatment of this type of disease, therefore, our target to evaluate whether monitoring early changes in plasma human epidermal growth factor receptor 2 (HER2) levels (using EIS), could help in the treatment of breast cancer or not? Human epidermal growth factor receptor 2 (HER2) overexpression is an important biomarker for treatment selection in earlier stages of cancers. The combined detection of the HER2 gene in plasma for blood cancer provides an important reference index for the prognosis of metastasis to other tissues. For this purpose, the authors fabricated and characterized a model wireless biosensor-based electrochemical impedance spectroscopy (EIS) for detecting HER2 plasma as therapeutics.

Design/methodology/approach

Most sensors generally are fabricated based on a connection between component of the sensors and the external circuits through wires. Although these types of sensors provide suitable sensitivities and also quick responses, the connection wires can be limited to the sensing ability in various devices approximately. Therefore, the authors designed a wireless sensor, which can provide the advantages of in vivo sensing and also long-distance sensing, quickly.

Findings

The biosensor structure was designed for detection of HER2, HER3 and HER-4 from lab-on-chip approach with six units of screen-printed electrode (SPE), which is built of an electrochemical device of gold/silver, silver/silver or carbon electrodes. The results exhibited that the biosensor is completely selective at low concentrations of the plasma and HER2 detection via the standard addition approach has a linearity plot, therefore, by using this type of biosensors HER2 in plasma can be detected.

Originality/value

This is then followed by detecting HER2 in real plasma using standard way which proved to have great linearity (R2 = 0.991) proving that this technique can be used to detect HER2 solution in real patients.

Article
Publication date: 18 July 2024

Anindya Bose, Sarthak Sengupta and Sayori Biswas

This study aims to provide a microfluidic blood glucose sensing platform based on integrated interdigitated electrode arrays (IDEAs) on a flexible quartz glass substrate, adhering…

Abstract

Purpose

This study aims to provide a microfluidic blood glucose sensing platform based on integrated interdigitated electrode arrays (IDEAs) on a flexible quartz glass substrate, adhering closely to pertinent electrochemical characterizations.

Design/methodology/approach

Sensors are the key elements of the modern electronics era through which all the possible physical quantities can be detected and converted into their equivalent electrical form and processed further. But to make the sensing environment better, various types of innovative architectures are being developed nowadays and among them interdigitated electrodes are quite remarkable in terms of their sensing capability. They are a well-qualified candidate in the field of gas sensing and biosensing, but even their sensitivities are getting saturated due to their physical dimensions. Most of the thin film IDEAs fabricated by conventional optical lithographic techniques do not possess a high surface-to-volume ratio to detect the target specified and that reduces their sensitivity factor. In this context, a classic conductive carbon-based highly sensitive three dimensional (3D) IDEA-enabled biosensing system has been conceived on a transparent and flexible substrate to measure the amount of glucose concentration present in human blood. 3D IDEA possesses a way better capacitive sensing behavior compared to conventional thin film microcapacitive electrodes. To transmit the target biological analyte sample property for the detection purpose to the interdigitated array-based sensing platform, the design of a microfluidic channel is initiated on the same substrate. The complex 3D Inter Digital array structure improves the overall capacitance of the entire sensing platform and the reactive surface area as well. The manufactured integrated device displays a decent value of sensitivity in the order of 5.6 µA mM−1 cm−2.

Findings

Development of a low-cost array-based integrated and highly flexible microfluidic biochip to extract the quantity of glucose present in human blood.

Originality/value

Potential future research opportunities in the realm of integrated miniaturized, low-cost smart biosensing systems may arise from this study.

Details

Sensor Review, vol. 44 no. 5
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 19 July 2024

Xinran Yang, Junhui Du, Hongshuo Chen, Chuanjin Cui, Haibin Liu and Xuechao Zhang

Field-effect transistor (FET) has excellent electronic properties and inherent signal amplification, and with the development of nanomaterials technology, FET biosensors with…

Abstract

Purpose

Field-effect transistor (FET) has excellent electronic properties and inherent signal amplification, and with the development of nanomaterials technology, FET biosensors with nanomaterials as channels play an important role in the field of heavy metal ion detection. This paper aims to review the research progress of silicon nanowire, graphene and carbon nanotube field-effect tube biosensors for heavy metal ion detection, so as to provide technical support and practical experience for the application and promotion of FET.

Design/methodology/approach

The article introduces the structure and principle of three kinds of FET with three kinds of nanomaterials, namely, silicon nanowires, graphene and carbon nanotubes, as the channels, and lists examples of the detection of common heavy metal ions by the three kinds of FET sensors in recent years. The article focuses on the advantages and disadvantages of the three sensors, puts forward measures to improve the performance of the FET and looks forward to its future development direction.

Findings

Compared with conventional instrumental analytical methods, FETs prepared using nanomaterials as channels have the advantages of fast response speed, high sensitivity and good selectivity, among which the diversified processing methods of graphene, the multi-heavy metal ions detection of silicon nanowires and the very low detection limit and wider detection range of carbon nanotubes have made them one of the most promising detection tools in the field of heavy metal ions detection. Of course, through in-depth analysis, this type of sensor has certain limitations, such as high cost and strict process requirements, which are yet to be solved.

Originality/value

This paper elaborates on the detection principle and classification of field-effect tube, investigates and researches the application status of three kinds of FET biosensors in the detection of common heavy metal ions. By comparing the advantages and disadvantages of each of the three sensors in practical applications, the paper focuses on the feasibility of improvement measures, looks forward to the development trend in the field of heavy metal detection and ultimately promotes the application of field-effect tube development technology to continue to progress, so that its performance continues to improve and the application field is constantly expanding.

Details

Sensor Review, vol. 44 no. 5
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 16 September 2024

Dmitry Leonidovich Kovalenko, Vy Uong Van, Van Phuc Mac, Thien Vuong Nguyen, Lan Pham Thi, Tuan Anh Nguyen, Vladimir Evgenevich Gaishun, Vasili Vasilievich Vaskevich and Dai Lam Tran

This paper aims to explore how graphene can improve the mechanical and anti-corrosion properties of TiO2-SiO2 sol-gel coating. This sol-gel coating has been prepared on aluminum…

Abstract

Purpose

This paper aims to explore how graphene can improve the mechanical and anti-corrosion properties of TiO2-SiO2 sol-gel coating. This sol-gel coating has been prepared on aluminum alloy substrate using graphene as both nano-filler and corrosion inhibitor.

Design/methodology/approach

To examine the effect of graphene on mechanical properties of sol-gel coating, the abrasion resistance, adhesion strength and scratch resistance of coating have been evaluated. To reveal the effect of graphene on the anti-corrosion property of coating for aluminum alloy, the electrochemical impedance spectroscopy (EIS) has been conducted in 3.5 Wt.% NaCl medium.

Findings

Scanning electron microscopy images indicate that graphene nanoplatelets (GNPs) have been homogeneously dispersed into the sol-gel coating matrices (at the contents from 0.1 to 0.5 Wt.%). Mechanical tests of coatings indicate that the graphene content of 0.5 Wt.% provides highest values of adhesion strength (1.48 MPa), scratch resistance (850 N) and abrasion strength (812 L./mil.) for the sol-gel coating. The EIS data show that the higher content of GNPs improve both R1 (coating) and R2 (coating/Al interface) resistances. In addition to enhancing the coating barrier performance (graphene acts as nanofiller/nano-reinforcer for coating matrix), other mechanism can be at work to account for the role of the graphene inhibitor in improving the anticorrosive performance at the coating/Al interface.

Originality/value

Application of graphene-based sol-gel coating for protection of aluminum and its alloy is very promising.

Details

Anti-Corrosion Methods and Materials, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 17 September 2024

Bo Zhang, Xi Chen, Hanwen You, Hong Jin and Hongxiang Peng

Ultracapacitors find extensive applications in various fields because of their high energy density and long cycling periods. However, due to the movement of ions and the…

Abstract

Purpose

Ultracapacitors find extensive applications in various fields because of their high energy density and long cycling periods. However, due to the movement of ions and the arrangement patterns on rough/irregular electrode surfaces during the charge and discharge process of ultracapacitors, the parameters of ultracapacitors usually change with the variation of operating conditions. The purpose of this study is to accurately and quickly identify the parameters of ultracapacitors.

Design/methodology/approach

A variable forgetting factor recursive least square (VFFRLS) algorithm is proposed in this paper for online identifying the equivalent series resistance and capacitance C of ultracapacitors. In this work, a real-time error-based strategy is developed to adaptively regulate the value of the forgetting factor of traditional forgetting factor recursive least square (FFRLS) algorithm. The strategy uses the square of the average time autocorrelation estimation of the prior error and the posterior error between the predicted output and the actual output as the adjustment basis of forgetting factors.

Findings

Experiments were conducted using the proposed scheme, and the results were compared with the estimation results obtained by the recursive least squares (RLS) algorithm and the traditional FFRLS algorithm. The maximum root mean square error between the estimated values and actual values for VFFRLS is 3.63%, whereas for FFRLS it is 9.61%, and for RLS it is 19.33%.

Originality/value

By using the proposed VFFRLS algorithm, a relatively high precision can be achieved for the online parameter estimation of ultracapacitors. Besides, the dynamic balance between parameter stability and tracking performance can be validated by dynamically adjusting the forgetting factor.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 13 September 2024

Jian Hou, Chenyang Liu, Han Wang, Zilin Li, Guosheng Huang, Li Ma and Bo Jiang Ma

This paper aims to control the deformation of a thin wall CrZrCu cylinder components (wall thickness 5 mm, diameter 400 mm) during thermal spray alumina-titania (AT13) coating by…

Abstract

Purpose

This paper aims to control the deformation of a thin wall CrZrCu cylinder components (wall thickness 5 mm, diameter 400 mm) during thermal spray alumina-titania (AT13) coating by adjusting the spray parameters without deteriorating its quality evidently.

Design/methodology/approach

The deformation was controlled by lowering the temperature of the component in the way of adjusting the spray parameters. The main parameters adjust included extending the spraying distance, from normally 120 mm to 140 mm, decreasing plasma power from 50to 42 kW. An alumina-titanium (AT13) ceramic coating was chosen for protecting the substrate from corrosion. Microscopic morphology and phase analysis, insulation resistance testing, neutral salt test and electrochemical method were used to analyze the anti-corrosion and insulation performances of the coating.

Findings

The results indicate that, after adjusting the spraying parameters, the coating has a relatively high porosity, with an average value of 8.96 ± 0.77%. The bonding strength of the coating is relatively low, with an average value of 17.69 ± 0.85 MPa. However, after sealing, the polarization resistance of the coating in seawater can be maintained above 6.25 × 106 Ω.cm2 for an extended period. The coating has a high resistance (=1.1 M Ω), and there is no apparent galvanic corrosion when contacted with TC4 alloy. Additionally, analysis of corrosion products on the sample surface reveals that the samples with sprayed alumina-titanium ceramic show no copper corrosion products on the surface, and the coating remains intact, effectively isolating the corrosive medium.

Originality/value

By adjusting the spraying parameters, the deformation of the cylinder thin-walled component can be effectively controlled, making the φ 400 × 392 mm (thickness 5 mm) CrZrCu cylinder com-ponent with a maximum diameter deformation of only 0.14 mm. The satisfactory corrosion performances can be achieved under adjusting spraying parameters, which can guarantee the application of ceramic coating for weapon launching system of naval ships.

Details

Anti-Corrosion Methods and Materials, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0003-5599

Keywords

Open Access
Article
Publication date: 10 July 2024

Felix Endress, Julius Tiesler and Markus Zimmermann

Metal laser-powder-bed-fusion using laser-beam parts are particularly susceptible to contamination due to particles attached to the surface. This may compromise so-called…

230

Abstract

Purpose

Metal laser-powder-bed-fusion using laser-beam parts are particularly susceptible to contamination due to particles attached to the surface. This may compromise so-called technical cleanliness (e.g. in NASA RPTSTD-8070, ASTM G93, ISO 14952 or ISO 16232), which is important for many 3D-printed components, such as implants or liquid rocket engines. The purpose of the presented comparative study is to show how cleanliness is improved by design and different surface treatment methods.

Design/methodology/approach

Convex and concave test parts were designed, built and surface-treated by combinations of media blasting, electroless nickel plating and electrochemical polishing. After cleaning and analysing the technical cleanliness according to ASTM and ISO standards, effects on particle contamination, appearance, mass and dimensional accuracy are presented.

Findings

Contamination reduction factors are introduced for different particle sizes and surface treatment methods. Surface treatments were more effective for concave design features, however, the initial and resulting absolute particle contamination was higher. Results further indicate that there are trade-offs between cleanliness and other objectives in design. Design guidelines are introduced to solve conflicts in design when requirements for cleanliness exist.

Originality/value

This paper recommends designing parts and corresponding process chains for manufacturing simultaneously. Incorporating post-processing characteristics into the design phase is both feasible and essential. In the experimental study, electroless nickel plating in combination with prior glass bead blasting resulted in the lowest total remaining particle contamination. This process applied for cleanliness is a novelty, as well as a comparison between the different surface treatment methods.

Details

Rapid Prototyping Journal, vol. 30 no. 11
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 13 September 2024

Kexin Liu, Shuhan Meng, Yi Zhang, Peng Zhou, Tao Zhang and Fuhui Wang

The purpose of this paper is to investigate the effect of plasma electrolytic oxidation (PEO) coatings and sealed PEO coatings on the corrosion resistance and cytocompatibility of…

Abstract

Purpose

The purpose of this paper is to investigate the effect of plasma electrolytic oxidation (PEO) coatings and sealed PEO coatings on the corrosion resistance and cytocompatibility of a novel Mg-1Zn-0.45Ca alloy in simulated body fluid (SBF).

Design/methodology/approach

The microstructure, corrosion resistance and cytocompatibility of PEO coatings and phosphate conversion-treated PEO coatings were investigated and was compared with the bare Mg alloy.

Findings

The hot-extruded Mg-Zn-Ca alloy exhibit inhomogeneous microstructure and suffered from localized corrosion in the SBF. The PEO coating after phosphate conversion treatment offers enhanced protectiveness to the Mg alloy within an immersion period of up to 60 days, which is significantly improved compared with the performance of the PEO-coated Mg alloy, but the cytocompatibility was slightly decreased.

Originality/value

This work offers new perspective in balancing the protectiveness and cytocompatibility of bio-materials.

Details

Anti-Corrosion Methods and Materials, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0003-5599

Keywords

Book part
Publication date: 12 September 2024

Ritujaa Khanolkar, Pradeep Choudhary and Dr Sonal Gupta

The ongoing adverse effects of climate change have led scientific think tanks to aim towards achieving net-zero greenhouse gas (GHG) emissions targets with affordable and clean…

Abstract

The ongoing adverse effects of climate change have led scientific think tanks to aim towards achieving net-zero greenhouse gas (GHG) emissions targets with affordable and clean energy (Sustainable Development Goal 7). One of the significant contributors to the escalating emissions rate is the use of conventional vehicles. The uptake of electric vehicles (EVs) is a promising solution for a cleaner economy. However, increased penetration poses various challenges to the power system. There is a need to explore alternatives, such as hydrogen fuel cell vehicles (HFCVs), to use the advantages of both electric and conventional vehicles and bridge the gap between them. However, the transition to hydrogen-based transport requires intensive study of its key benefits and issues, the actions that need to be taken to achieve a changeover concerning light and heavy vehicles and whether such kind of transformation is likely or even possible. This chapter highlights the brief history and mechanics of HFCVs. It further analyses the various benefits and challenges which the technology poses. Additionally, it addresses critical questions regarding the feasibility of the shift towards hydrogen fuel to satisfy the world's rapidly growing energy needs and meet net-zero targets based on real-life applications. This chapter will be a valuable resource for further research, development and education efforts in HCFVs to assist in the rapidly growing transportation needs for automobiles and other vehicles.

Open Access
Article
Publication date: 22 July 2024

Alessandro Bove, Fulvio Lieske, Flaviana Calignano and Luca Iuliano

Material extrusion (MEX) is one of the most known techniques in the additive manufacturing (AM) sector to produce components with a wide range of polymeric and composite…

Abstract

Purpose

Material extrusion (MEX) is one of the most known techniques in the additive manufacturing (AM) sector to produce components with a wide range of polymeric and composite materials. Moisture causes alterations in material properties and for filaments strongly hygroscopic like nylon-based composites this means greater ease of deterioration. Drying the filament to reduce the moisture content may not be sufficient if the humidity is not controlled during printing. The purpose of this study is to achieve the recovery of a commercial nylon-based composite filament by applying process optimization using an open source MEX machine.

Design/methodology/approach

A statistical approach based on Taguchi’s method allowed to achieve an ultimate tensile strength (UTS). A verification of the geometrical capabilities of the process has been performed according to the standard ISO/ASTM 52902-2019. Chemical tests were also carried out to test the resistance to corrosion in acid and basic solutions.

Findings

An UTS of 71.37 MPa was obtained, significantly higher than the value declared by the filament’s manufacturer (Stratasys Inc., USA). The best configuration of process parameters leads to good geometrical deviations for flat surfaces, in a range of 0.01 and 0.38 for flatness, while cylindrical faces showed more important deviations from the nominal values. The good applicability of the material in corrosive environments has been confirmed.

Originality/value

This study examined the performance restoration potential of a nylon composite filament that was significantly affected by storage conditions. For the filament manufacturer, if the material remains in ambient air for an hour or idle in the machine for more than 24 h, the material may no longer be suitable for printing. The study highlighted that the drying of the filament must not be temporary but constant to guarantee printability, and, by acting on the process parameters, it is possible to obtain better mechanical properties than declared by the manufacturer.

Details

Rapid Prototyping Journal, vol. 30 no. 11
Type: Research Article
ISSN: 1355-2546

Keywords

1 – 10 of 19