Search results

1 – 10 of 19
Article
Publication date: 8 June 2022

Chinnaraj Gnanavel and Kumarasamy Vanchinathan

These implementations not only generate excessive voltage levels to enhance the quality of power but also include a detailed investigating of the various modulation methods and…

Abstract

Purpose

These implementations not only generate excessive voltage levels to enhance the quality of power but also include a detailed investigating of the various modulation methods and control schemes for multilevel inverter (MLI) topologies. Reduced harmonic modulation technology is used to produce 11-level output voltage with the production of renewable energy applications. The simulation is done in the MATLAB/Simulink for 11-level symmetric MLI and is correlated with the conventional inverter design.

Design/methodology/approach

This paper is focused on investigating the different types of asymmetric, symmetric and hybrid topologies and control methods used for the modular multilevel inverter (MMI) operation. Classical MLI configurations are affected by performance issues such as poor power quality, uneconomic structure and low efficiency.

Findings

The variations in both carrier and reference signals and their performance are analyzed for the proposed inverter topologies. The simulation result compares unipolar and bipolar pulse-width modulation (PWM) techniques with total harmonic distortion (THD) results. The solar-fed 11-level MMI is controlled using various modulation strategies, which are connected to marine emergency lighting loads. Various modulation techniques are used to control the solar-fed 11-level MMI, which is connected to marine emergency lighting loads. The entire hardware system is controlled by using SPARTAN 3A field programmable gate array (FPGA) board and the least harmonics are obtained by improving the power quality.

Originality/value

The simulation result compares unipolar and bipolar PWM techniques with THD results. Various modulation techniques are used to control the solar-fed 11-level MMI, which is connected to marine emergency lighting loads. The entire hardware system is controlled by a SPARTAN 3A field programmable gate array (FPGA) board, and the power quality is improved to achieve the lowest harmonics possible.

Details

Circuit World, vol. 49 no. 4
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 23 March 2022

Dania Batool, Qandeel Malik, Tila Muhammad, Adnan Umar Khan and Jonghoon Kim

Multilevel inverters play a major role in the development of high-power industrial applications. In traditional low-level inverters (e.g. 2-level), the switching frequency is…

Abstract

Purpose

Multilevel inverters play a major role in the development of high-power industrial applications. In traditional low-level inverters (e.g. 2-level), the switching frequency is restricted and the harmonic spectrum of the system is hard to meet power requirements. Similarly, high-level inverters consist of a large number of switches, complex modulation techniques and complex hardware architecture, which results in high power loss and a significant amount of harmonic distortion. Furthermore, it is a must to ensure that every switch experiences the same stress of voltage and current. The purpose of this paper is to present an inverter topology with lower conduction and switching losses via reduced number of switches and equal voltage source-sharing technique.

Design/methodology/approach

Herein, the authors present a cascaded multilevel inverter having less power switches, a simple modulation technique and an equal voltage source-sharing phenomenon implementation.

Findings

The modulation technique becomes more complex when equal voltage source-sharing is to be implemented. In this study, a novel topology for the multilevel inverter with fewer switches, novel modulation technique, equal voltage source-sharing and Inductor-Capacitor-Inductor filter implementation is demonstrated to the reduce harmonic spectrum and power losses of the proposed system.

Originality/value

The nine-level inverter design is validated using software simulations and hardware prototype testing; the power losses of the proposed inverter design are elaborated and compared with the traditional approach.

Article
Publication date: 31 March 2023

Tapas Kumar Mohapatra and Asim Kumar Dey

This study aims to propose a unique algorithm-based hysteresis current control technique (HCCT) for induction motor using a single-phase voltage source inverter (SPVSI) to…

Abstract

Purpose

This study aims to propose a unique algorithm-based hysteresis current control technique (HCCT) for induction motor using a single-phase voltage source inverter (SPVSI) to eliminate both sub and inter harmonics (SIH) and electromagnetic interference (EMI). The total harmonic distortion (THD) of the load current also reduces in comparison to standard HCCT and modified technique-based existing HCCT.

Design/methodology/approach

Matlab simulation has been carried out to develop an SPVSI model and the unique algorithm-based HCCT. The same platform has also been used to develop a few existing HCCTs such as standard, dual-band and modified. The switching frequency and harmonic analysis of load currents for all the HCCTs have been compared in the paper. The hardware implementation of the proposed algorithm-based HCCT was also verified and compared with the simulation results.

Findings

The proposed unique algorithm-based HCCT provides the benefits of both unipolar and bipolar switching techniques. It reduces the switching frequency as unipolar switching scheme and eliminates the EMI. It also reduces THD and nullifies SIH of the load current. This enables an improvement in the overall performance and efficiency of the motor.

Practical implications

This proposed HCCT eliminates the SIH and improves the overall efficiency of the motor, hence can prevent overheating, vibration, acoustic noise, pulsating torque and braking of the rotor shaft of the motor and increasing the reliability of the system.

Social implications

It can be implemented for the motors that are used in household applications and electric vehicles through one-phase inverter.

Originality/value

This proposed HCCT has detected the zero crossing point of reference current, allowed samples and shifted the necessary amount of hysteresis band at zero crossing region to eliminate SIH and THD.

Details

World Journal of Engineering, vol. 21 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 17 May 2023

Rajini V., Jassem M., Nagarajan V.S., Sreeya Galla N.V. Sai and Jeyapradha Rb

Industrial drives require appropriate control systems for reliable and efficient performance. With synchronous reluctance machines (SynRMs) slowly replacing the most commonly used…

Abstract

Purpose

Industrial drives require appropriate control systems for reliable and efficient performance. With synchronous reluctance machines (SynRMs) slowly replacing the most commonly used induction, switched reluctance and permanent magnet machines, it is essential that the drive and its control be properly selected for enhanced performance. But the major drawback of synchronous reluctance motor is the presence of high torque ripple as its design is characterized by large number of variables. The solutions to reduce torque ripple include design modifications, choice of proper power electronic inverter and PWM strategy. But little has been explored about the power electronic inverters suited for synchronous reluctance motor drive to minimize torque ripple inherently by obtaining a more sinusoidal voltage. The purpose of this paper is to elaborate on the potential multilevel inverter topologies applicable to SynRM drives used in solar pumping applications.

Design/methodology/approach

The most significant field-oriented control using maximum torque per ampere algorithm for maximizing the torque production is used for the control of SynRM. Simulation results carried out using Matlab/Simulink are presented to justify the choice of inverter and its control technique for SynRM.

Findings

The five-level inverter drive gives lesser core or iron losses in the SynRMin comparison to the three- and two-level inverters due to lower Id current ripple. The five-level inverter reduces the torque ripple of the SynRM significantly in comparison to the three- and two-level inverter fed SynRM drives. The phase disposition-PWM control method used for the inverter shows the least total harmonic distortion (THD) levels in output voltage compared with the other level shifted PWM techniques.

Originality/value

Among the available topologies, a fitting topology is proposed for use for the SynRM drive to have minimal THD, minimal current and torque ripple. Additionally, this paper presents various modulation techniques available for the selected drive system and reports on a suitable technique based on minimal THD of output voltage and hence minimal torque ripple.

Details

Circuit World, vol. 50 no. 1
Type: Research Article
ISSN: 0305-6120

Keywords

Open Access
Article
Publication date: 11 October 2023

Abdulwasa B. Barnawi, Abdull Rahman A. Alfifi, Z.M.S. Elbarbary, Saad Fahed Alqahtani and Irshad Mohammad Shaik

Traditional level inverter technology has drawbacks in the aspect of Total harmonic distortion (THD) and switching losses for higher frequencies. Due to these drawbacks, two-level…

Abstract

Purpose

Traditional level inverter technology has drawbacks in the aspect of Total harmonic distortion (THD) and switching losses for higher frequencies. Due to these drawbacks, two-level inverters have become unprofitable for high-power applications. Multilevel inverters (MLIs) are used to enhance the output waveform characteristics (i.e. low THD) and to offer various inverter topologies and switching methods.

Design/methodology/approach

MLIs are upgraded versions of two-level inverters that offer more output levels in current and voltage waveforms while lowering the dv/dt and di/dt ratios. This paper aims to review and compare the different topologies of MLI used in high-power applications. Single and multisource MLI's working principal and switching states for each topology are demonstrated and compared. A Simulink model system integrated using detailed circuit simulations in developed in MATLAB®–Simulink program. In this system, a constant voltage source connected to MLI to feed asynchronous motor with squirrel cage rotor type is used to demonstrate the efficacy of the MLI under different varying speed and torque conditions.

Findings

MLI has presented better control and good range of system parameters than two-level inverter. It is suggested that the MLIs like cascade-five-level and NPC-five-level have shown low current harmonics of around 0.43% and 1.87%, respectively, compared to two-level inverter showing 5.82%.

Originality/value

This study is the first of its kind comparing the different topologies of single and multisource MLIs. This study suggests that the MLIs are more suitable for high-power applications.

Details

Frontiers in Engineering and Built Environment, vol. 4 no. 2
Type: Research Article
ISSN: 2634-2499

Keywords

Article
Publication date: 10 February 2023

Kanungo Barada Mohanty and Pavankumar Daramukkala

The purpose of this study is to provide the enhancement of power quality of a high power-rated voltage source inverter driven induction motor with a three-phase, three-level…

Abstract

Purpose

The purpose of this study is to provide the enhancement of power quality of a high power-rated voltage source inverter driven induction motor with a three-phase, three-level neutral point clamped converter placed at the front end, while a passive power filter is connected in shunt with it. The improvement in power quality can be achieved by reducing the total harmonic distortion in source current. The controllers were designed for the linearization of the high-power induction motor drive. A control method is presented for the regulation of the common DC-link voltage.

Design/methodology/approach

The induction motor is modeled using its dynamic equations, and a decoupling controller is designed to linearize the nonlinear dynamics of the drive through feedback. The common DC-link voltage of the proposed front-end connected converter is monitored and controlled through a control method which feeds the pulse width modulated inverter that drives the induction motor. A passive power filter is designed to meet the reactive power requirement of the system in addition to improve the power quality.

Findings

Simulations were carried out for the proposed topology of the drive mechanism, and the outcomes were analyzed by a comparative analysis of the drive system both in the presence of the passive filter as well as in the absence of the filter. The total harmonic distortion is found to be reduced enough to meet the standards with the designed filter, and the reactive power is also compensated considerably. The input power factor at the supply side is maintained almost to unity, and the DC-link voltage of the proposed circuit topology is maintained at the desired level. The overall performance of the drive system was found to be useful and economical.

Originality/value

A new topology of a front-end connected three-level neutral point clamped converter to a high power-rated induction motor drive is proposed. The drive is fed by a pulse width modulated inverter with a common DC-link with the front end connected converter. A passive filter is designed with respect to the reactive power requirement of the system and connected in shunt to the converter at the supply side. Control schemes are designed and used for the drive system and also for the regulation of the common DC-link voltage of the proposed front end connected converter.

Details

World Journal of Engineering, vol. 21 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 11 May 2022

Rashmi Rekha Behera, Ashish Ranjan Dash and Anup Kumar Panda

The purpose of this paper is to design a cascaded Multilevel inverter with reduce number of switches for high power applications. This paper came up with an innovative three-phase…

Abstract

Purpose

The purpose of this paper is to design a cascaded Multilevel inverter with reduce number of switches for high power applications. This paper came up with an innovative three-phase multilevel inverter (MLI) topology, which is a cascaded structure based on classical three-legged voltage source inverter (VSI) bridges as an individual module. The prominent advantage of this topology is that it requires only one direct current (DC) link system. The main characteristic of it is that a higher number of voltage levels can be achieved with considerably a smaller number of semiconductor switches, which improves the reliability, power quality, cost and size of the system significantly.

Design/methodology/approach

The individual modules are cascaded through three-phase transformers to provide higher voltage at the output with the higher number of voltage levels. In this work, the phase-shifted pulse width modulation technique is implemented to verify the result.

Findings

The proposed topology is compared with three-phase cascaded H-bridge MLI (CHB-MLI) and a modified CHB-MLI topology and found better in many aspects. The proposed MLI can produce a higher number of voltage levels with fewer semiconductor switches and associated triggering circuitry. As the device count in the proposed MLI is less compared to other MLI discussed, it tends to have less switching and conduction loss which increases the efficiency and reliability. As the number of level increases, the voltage profile and the total harmonic distortion of the proposed MLI improves.

Originality/value

This is a transformer-based modular cascaded MLI, which is based on classical VSI bridges. Here in this topology, a single module provides all three phases. So, a single string of cascaded modules is enough for three-phase multilevel voltage generation.

Details

World Journal of Engineering, vol. 20 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 15 February 2024

Yumin He, Tingyun Gu, Bowen Li, Yu Wang, Dongyuan Qiu, Yang Zhang and Peicheng Qiu

Electric spring (ES) is a demand response method that can stabilize the voltage of critical loads and improve power quality, especially in a weak power grid with a high proportion…

Abstract

Purpose

Electric spring (ES) is a demand response method that can stabilize the voltage of critical loads and improve power quality, especially in a weak power grid with a high proportion of renewable energy sources. Most of existing ESs are implemented by voltage-source inverter (VSI), which has some shortcomings. For example, the DC-link capacitor limits the service life of ES, and the battery is costly and hard to recycle. Besides, conventional VSI cannot boost the voltage, which limits the application of ES in high-voltage occasions. This study aims to propose a novel scheme of ES to solve the above problems.

Design/methodology/approach

In this work, an ES topology based on current-source inverter (CSI) without a battery is presented, and a direct current control strategy is proposed. The operating principles, voltage regulation range and parameter design of the proposed ES are discussed in detail.

Findings

The proposed ES is applicable to various voltage levels, and the harmonics are effectively suppressed, which have been validated via the experimental results in both ideal and distorted grid conditions.

Originality/value

An ES topology based on battery-less CSI is proposed for the first time, which reduces the cost and prolongs the service time of ES. A novel control strategy is proposed to realize the functions of voltage regulation and harmonic suppression.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 43 no. 1
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 4 August 2022

Biranchi Narayan Kar, Paulson Samuel, Jatin Kumar Pradhan and Amit Mallick

This paper aims to present an improvement to the power quality of the grid by using a colliding body optimization (CBO) based proportional-integral (PI) compensated design for a…

Abstract

Purpose

This paper aims to present an improvement to the power quality of the grid by using a colliding body optimization (CBO) based proportional-integral (PI) compensated design for a grid-connected solar photovoltaic-fed brushless DC motor (BLDC)-driven water pumping system with a bidirectional power flow control. The system with bidirectional power flow allows driving the pump at full proportions uninterruptedly irrespective of the weather conditions and feeding a grid when water pumping is not required.

Design/methodology/approach

Here, power quality issue is taken care of by the optimal generation of the duty cycle of the voltage source converter. The duty cycle is optimally generated by optimal selection of the gains of the current controller (i.e. PI), with the CBO technique resulting in a nearly unity power factor as well as lower total harmonic distortion (THD) of input current. In the CBO technique, the gains of the PI controller are considered as agents and collide with each other to obtain the best value. The system is simulated using MATLAB/Simulink and validated in real time with OPAL RT simulator, OP5700.

Findings

It was found that the power quality of grid using the CBO technique has improved much better than the particle swarm optimization and Zeigler–Nichols approach. The bidirectional flow of control of VSC allowed for optimum resource utilization and full capacity of water pumping whatever may be weather conditions.

Originality/value

Improved power quality of grid by optimally generation of the duty cycle for the proposed system. A unit vector tamplate generation technique is used for bidirectional power transfer.

Article
Publication date: 29 July 2022

Yumei Song, Jianzhang Hao, Changhao Dong, Xizheng Guo and Li Wang

This paper aims to study a multi-level reinjection current source converter (MLR-CSC) that adds attracting properties such as the self-commutation and pulse multiplication to the…

Abstract

Purpose

This paper aims to study a multi-level reinjection current source converter (MLR-CSC) that adds attracting properties such as the self-commutation and pulse multiplication to the thyristor converter, which is of great significance for increasing the device capacity and reducing current harmonics on the grid side. Particularly, designing advantageous driving methods of the reinjection circuit is a critical issue that impacts the harmonic reduction and operation reliability of the MLR-CSC.

Design/methodology/approach

To deal with the mentioned issue, this paper takes the five-level reinjection current source converter (FLR-CSC), which is a type of the MLR-CSC, as the research object. Then, a method that can fully use combinations of five-level reinjection switching functions based on the concept of decomposition and recombination is proposed. It is worthy to mention that the proposed method can be easily extended to other multi-level reinjection circuits. Moreover, the working principle of the three-phase bridge circuit based on semi-controlled thyristors in the FLR-CSC that can achieve the four-quadrant power conversion is analyzed in detail.

Findings

Finally, the simulation and experimental results of FLR-CSC verify the effectiveness of the proposed reinjection circuit driving method and the operating principle of four-quadrant power conversion in this paper.

Originality/value

The outstanding features of the proposed driving method for FLR-CSC in this paper include combinations of reinjection switching functions that are fully exploited through three simple steps and can be conveniently extended to other multi-level reinjection circuits.

Details

Microelectronics International, vol. 40 no. 3
Type: Research Article
ISSN: 1356-5362

Keywords