Search results

1 – 10 of 61
Open Access
Article
Publication date: 6 September 2022

Paul Roelofsen and Kaspar Jansen

The purpose of this study is to analyze the question “In what order of magnitude does the comfort and performance improvement lie with the use of a cooling vest for construction…

1268

Abstract

Purpose

The purpose of this study is to analyze the question “In what order of magnitude does the comfort and performance improvement lie with the use of a cooling vest for construction workers?”.

Design/methodology/approach

The use of personal cooling systems, in the form of cooling vests, is not only intended to reduce the heat load, in order to prevent disruption of the thermoregulation system of the body, but also to improve work performance. A calculation study was carried out on the basis of four validated mathematical models, namely a cooling vest model, a thermophysiological human model, a dynamic thermal sensation model and a performance loss model for construction workers.

Findings

The use of a cooling vest has a significant beneficial effect on the thermal sensation and the loss of performance, depending on the thermal load on the body.

Research limitations/implications

Each cooling vest can be characterized on the basis of the maximum cooling power (Pmax; in W/m²), the cooling capacity (Auc; in Wh/m2) and the time (tc; in minutes) after which the cooling power is negligible. In order to objectively compare cooling vests, a (preferably International and/or European) standard/guideline must be compiled to determine the cooling power and the cooling capacity of cooling vests.

Practical implications

It is recommended to implement the use of cooling vests in the construction process so that employees can use them if necessary or desired.

Social implications

Climate change, resulting in global warming, is one of the biggest problems of present times. Rising outdoor temperatures will continue in the 21st century, with a greater frequency and duration of heat waves. Some regions of the world are more affected than others. Europe is one of the regions of the world where rising global temperatures will adversely affect public health, especially that of the labor force, resulting in a decline in labor productivity. It will be clear that in many situations air conditioning is not an option because it does not provide sufficient cooling or it is a very expensive investment; for example, in the situation of construction work. In such a situation, personal cooling systems, such as cooling vests, can be an efficient and financially attractive solution to the problem of discomfort and heat stress.

Originality/value

The value of the study lies in the link between four validated mathematical models, namely a cooling vest model, a thermophysiological human model, a dynamic thermal sensation model and a performance loss model for construction workers.

Details

International Journal of Clothing Science and Technology, vol. 35 no. 1
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 28 October 2014

George Pichurov, Radostina Angelova, Iskra Simova, Iosu Rodrigo and Peter Stankov

The purpose of this paper is to integrate a thermophysiological human body model into a CFD simulation to predict the dry and latent body heat loss, the clothing, skin and core…

Abstract

Purpose

The purpose of this paper is to integrate a thermophysiological human body model into a CFD simulation to predict the dry and latent body heat loss, the clothing, skin and core temperature, skin wettedness and periphery blood flow distribution. The integration of the model allows to generate more realistic boundary conditions for the CFD simulation and allows to predict the room distribution of temperature and humidity originating from the occupants.

Design/methodology/approach

A two-dimensional thermophysiological body model is integrated into a CFD simulation to predict the interaction between the human body and room environment. Parameters varied were clothing insulation and metabolic activity and supply air temperature. The body dry and latent heat loss, skin wettedness, skin and core temperatures were predicted together with the room air temperature and humidity.

Findings

Clothing and metabolic activity were found to have different level of impact on the dry and latent heat loss. Heat loss was more strongly affected by changes in the metabolic rate than in the clothing insulation. Latent heat loss was found to exhibit much larger variations compared to dry heat loss due to the high latent heat potential of water.

Originality/value

Unlike similar studies featuring naked human body, clothing characteristics like sensible resistance and vapor permeability were accommodated into the present study. A method to ensure numerical stability of the integrated simulation was developed and implemented to produce robust and reliable simulation performance.

Details

International Journal of Clothing Science and Technology, vol. 26 no. 6
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 2 March 2015

Radostina A. Angelova, George Pichurov, Iskra Simova, Peter Stankov and Iosu Rodrigo

– The purpose of the paper is to simulate the effect of clothing insulation and activity on the interaction between the human body and the environment.

Abstract

Purpose

The purpose of the paper is to simulate the effect of clothing insulation and activity on the interaction between the human body and the environment.

Design/methodology/approach

A thermo-physiological model, integrated into a Fluent CFD software package is applied. The temperature of the skin surface, clothing surface and heat flux (dry and total heat flux) through layers of clothing with different insulation level are numerically investigated in function of the clothing insulation and the different activities performed indoors.

Findings

The increase of the clothing insulation leads to increase of both skin and clothing temperature. Higher temperature difference ΔT between the room temperature and skin temperature provokes more dynamic change of the skin temperature and decreases the thermal comfort of the person. The increase of the metabolic rate, however, leads to more uniform skin temperature, regardless the temperature difference ΔT. With the increase of the clothing insulation for a constant metabolic rate the total heat flux remains constant, but the dry heat flux decreases, while the evaporative heat flux increases.

Originality/value

The joint influence of clothing insulation and indoor activities on the thermal interaction between the body and the environment is assesses using a thermo-physiological model, integrated in a CFD software package.

Details

International Journal of Clothing Science and Technology, vol. 27 no. 1
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 1 June 2002

Roger L. Barker

This paper traces the evolution of objective measurement of textile hand and comfort from Pierce through modern methodology and approaches. Special emphasis is given to discuss…

3662

Abstract

This paper traces the evolution of objective measurement of textile hand and comfort from Pierce through modern methodology and approaches. Special emphasis is given to discuss the contribution of the Kawabata Evaluation System (KES) towards advancing the state of objective measurement. Laboratory case studies are used to show how data generated by the KES and other instruments can be integrated into a comprehensive approach that attempts to explain human comfort response to garment wear in terms of fabric mechanical, surface and heat and moisture transfer properties.

Details

International Journal of Clothing Science and Technology, vol. 14 no. 3/4
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 15 March 2018

Anna Katarzyna Dabrowska

The purpose of this paper is to develop artificial neural networks (ANNs) allowing us to simulate the local thermal insulation of clothing protecting against cold on a basis of…

Abstract

Purpose

The purpose of this paper is to develop artificial neural networks (ANNs) allowing us to simulate the local thermal insulation of clothing protecting against cold on a basis of the characteristics of materials and design solutions used.

Design/methodology/approach

For this purpose, laboratory tests of thermal insulation of clothing protecting against cold as well as thermal resistance of textile systems used in the clothing were performed. These tests were conducted with a use of thermal manikin and so-called skin model, respectively. On a basis of results gathered, 12 ANNs were developed that correspond to each thermal manikin’s segment besides hands and feet which are not covered by protective clothing.

Findings

In order to obtain high level of simulations, optimization measures for the developed ANNs were introduced. Finally, conducted validation indicated a very high correlation (above 0.95) between theoretical and experimental results, as well as a low error of the simulations (max 8 percent).

Originality/value

The literature reports addressing the problem of modeling thermal insulation of clothing focus mainly on the impact of the degree of fit and the velocity of air movement on thermal insulation properties, whereas reports dedicated to modeling the impact of the construction of clothing protecting against cold as well as of diverse material systems used within one design of clothing on its thermal insulation are scarce.

Details

International Journal of Clothing Science and Technology, vol. 30 no. 1
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 1 July 2002

Paul Roelofsen

One of the fundamental human requirements is a working environment that allows people to perform their work optimally under comfortable conditions. Given that buildings and air…

11702

Abstract

One of the fundamental human requirements is a working environment that allows people to perform their work optimally under comfortable conditions. Given that buildings and air conditioning systems are designed on the basis of a certain level of discomfort, this raises the key question ‘What is the effect of the level of comfort on the productivity of people working in office environments?’ The purpose of this paper is to quantify this relationship as an aid to making choices regarding the working environment at strategic level within the facilities management process, with particular emphasis on thermal conditions.

Details

Journal of Facilities Management, vol. 1 no. 3
Type: Research Article
ISSN: 1472-5967

Keywords

Article
Publication date: 11 October 2018

Surendra Balaji Devarakonda, Pallavi Bulusu, Marwan Al-rjoub, Amit Bhattacharya and Rupak Kumar Banerjee

The purpose of this study is to evaluate the impact of external head cooling on alleviating the heat stress in the human body by analyzing the temperatures of the core body (Tc)…

Abstract

Purpose

The purpose of this study is to evaluate the impact of external head cooling on alleviating the heat stress in the human body by analyzing the temperatures of the core body (Tc), blood (Tblood) and head (Th) during exercise conditions using 3D whole body model.

Design/methodology/approach

Computational study is conducted to comprehend the influence of external head cooling on Tc, Tblood and Th. The Pennes bioheat and energy balance equations formulated for the whole-body model are solved concurrently to obtain Tc, Tblood and Th for external head cooling values from 33 to 233 W/m2. Increased external head cooling of 404 W/m2 is used to compare the numerical and experimental Th data.

Findings

Significant reductions of 0.21°C and 0.38°C are observed in Th with external head cooling of 233 and 404 W/m2, respectively. However, for external head cooling of 233 W/m2, lesser reductions of 0.03°C and 0.06°C are found in Tc and Tblood, respectively. Computational results for external head cooling of 404 W/m2 show a difference of 15 per cent in Th compared to experimental values from literature.

Originality/value

The development of stress because of heat generated within human body is major concern for athletes exercising at high intensities. This study provides an insight into the effectiveness of external head cooling in regulating the head and body temperatures during exercise conditions.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 28 no. 10
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 10 October 2022

Manoj Kumar Imrith, Satyadev Rosunee and Roshan Unmar

Lightweight, open construction cotton knitted fabrics generally do not impart good protection from solar ultraviolet radiation (UVR). As lightweight 100% cotton single jersey is…

Abstract

Purpose

Lightweight, open construction cotton knitted fabrics generally do not impart good protection from solar ultraviolet radiation (UVR). As lightweight 100% cotton single jersey is highly cherished for summerwear, it is sine qua non to understand the structural parameters that effectively strike a good balance between UV protection and thermophysiological comfort of the wearer. Relatively heavy fabrics protect from UVR, but comfort is compromised because of waning porosity, increase in thickness and thermal insulation. The purpose of this paper is to engineer knits that will bestow maximum UV protection while preserving the thermophysiological comfort of the wearer.

Design/methodology/approach

In total, 27 cotton single jersey fabrics with different areal densities and yarn counts were selected. Ultraviolet protection factor (UPF) was calculated based on the work of Imrith (2022). To précis, the authors constructed a UV box to measure the UPF of fabrics, denoted as UPFB. UPFB data were correlated with AATCC 183-2004 and yielded high correlation, R2 0.977. It was concluded that UPF 50 corresponds to UPFB 94.3. Thermal comfort properties were measured on the Alambeta and water-vapour resistance on the Permetest. Linear programming (LP) was used to optimize UPFB and comfort. Linear optimization focused on maximizing UPFB while keeping the thermophysiological comfort and areal density as constraints.

Findings

The resulting linear geometrical and sensitivity analyses generated multiple technically feasible solutions of fabrics thickness and porosity that gave valid UPFB, thermal absorptivity and water-vapour and thermal resistance. Subsequently, an interactive optimization software was developed to predict the stitch length, tightness factor and yarn count for optimum UPFB from a given areal density. The predicted values were then used to knit seven 100% cotton single jersey fabrics and were tested for UV protection. All seven fabrics gave UPFB above the threshold, that is, higher than 94.3. The mathematical model demonstrated good correlations with the optimized parameters and experimental values.

Originality/value

The optimization software predicted the optimum UPFB reasonably well, starting from the fabric structural and constructional parameters. In addition, the models were developed as interactive user interfaces, which can be used by knitted fabric developers to engineer cotton knits for maximizing UV protection without compromising thermophysiological comfort. It has been demonstrated that LP is an efficient tool for the optimization and prediction of targeted knitted fabrics parameters.

Details

Research Journal of Textile and Apparel, vol. 27 no. 3
Type: Research Article
ISSN: 1560-6074

Keywords

Article
Publication date: 5 October 2015

Albert P.C. Chan, Yang Yang, Francis K.W. Wong, Daniel W.M. Chan and Edmond W.M. Lam

– The aim of this study is to investigate wearing comfort of summer work uniforms judged by construction workers.

Abstract

Purpose

The aim of this study is to investigate wearing comfort of summer work uniforms judged by construction workers.

Design/methodology/approach

A total of 189 male construction workers participated in a series of wear trials and questionnaire surveys in the summer of 2014. They were asked to randomly wear two types of work uniforms (i.e. uniforms A and B) in the two-day field survey and the subjective attributes of these uniforms were assessed. Three analytical techniques, namely, multiple regression, artificial neural network and fuzzy logic were used to predict wearing comfort affected by the six subjective sensations.

Findings

The results revealed that fuzzy logic was a robust and practical tool for predicting wearing comfort in terms of better prediction performance and more interpretable results than the other models. Pressure attributes were further found to exert a greater effect than thermal–wet attributes on wearing comfort. Overall, the use of uniform B exhibited profound benefits on wearing comfort because it kept workers cooler, drier and more comfortable with less work performance interference than wearing uniform A.

Originality/value

The findings provide a fresh insight into construction workers’ needs for work clothes, which further facilitates the improvement in the clothing tailor-made design and the enhancement of the well-being of workers.

Details

Construction Innovation, vol. 15 no. 4
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 5 May 2020

Qi Jie Kwong, Jim Yexin Yang, Oliver Hoon Leh Ling, Rodger Edwards and Jamalunlaili Abdullah

The purpose of this paper is to analyse the thermal environment of two engineering testing centres cooled via different means using computational fluid dynamics (CFD), focussing…

Abstract

Purpose

The purpose of this paper is to analyse the thermal environment of two engineering testing centres cooled via different means using computational fluid dynamics (CFD), focussing on the indoor temperature and air movement. This computational technique has been used in the analysis of thermal environment in buildings where the profiles of thermal comfort parameters, such as air temperature and velocity, are studied.

Design/methodology/approach

A pilot survey was conducted at two engineering testing centres – a passively cooled workshop and an air-conditioned laboratory. Electronic sensors were used in addition to building design documentation to collect the required information for the CFD model–based prediction of air temperature and velocity distribution patterns for the laboratory and workshop. In the models, both laboratory and workshop were presumed to be fully occupied. The predictions were then compared to empirical data that were obtained from field measurements. Operative temperature and predicted mean vote (PMV)–predicted percentage dissatisfied (PPD) indices were calculated in each case in order to predict thermal comfort levels.

Findings

The simulated results indicated that the mean air temperatures of 21.5°C and 32.4°C in the laboratory and workshop, respectively, were in excess of the recommended thermal comfort ranges specified in MS1525, a local energy efficiency guideline for non-residential buildings. However, air velocities above 0.3 m/s were predicted in the two testing facilities, which would be acceptable to most occupants. Based on the calculated PMV derived from the CFD predictions, the thermal sensation of users of the air-conditioned laboratory was predicted as −1.7 where a “slightly cool” thermal experience would prevail, but machinery operators in the workshop would find their thermal environment too warm with an overall sensation score of 2.4. A comparison of the simulated and empirical results showed that the air temperatures were in good agreement with a percentage of difference below 2%. However, the level of correlation was not replicated for the air velocity results, owing to uncertainties in the selected boundary conditions, which was due to limitations in the measuring instrumentation used.

Research limitations/implications

Due to the varying designs, the simulated results of this study are only applicable to laboratory and workshop facilities located in the tropics.

Practical implications

The results of this study will enable building services and air-conditioning engineers, especially those who are in charge of the air-conditioning and mechanical ventilation (ACMV) system design and maintenance to have a better understanding of the thermal environment and comfort conditions in the testing facilities, leading to a more effective technical and managerial planning for an optimised thermal comfort management. The method of this work can be extended to the development of CFD models for other testing facilities in educational institutions.

Social implications

The findings of this work are particularly useful for both industry and academia as the indoor environment of real engineering testing facilities were simulated and analysed. Students and staff in the higher educational institutions would benefit from the improved thermal comfort conditions in these facilities.

Originality/value

For the time being, CFD studies have been carried out to evaluate thermal comfort conditions in various building spaces. However, the information of thermal comfort in the engineering testing centres, of particular those in the hot–humid region are scantily available. The outcomes of this simulation work showed the usefulness of CFD in assisting the management of such facilities not only in the design of efficient ACMV systems but also in enhancing indoor thermal comfort.

Details

Smart and Sustainable Built Environment, vol. 10 no. 1
Type: Research Article
ISSN: 2046-6099

Keywords