Search results

1 – 10 of over 13000
Article
Publication date: 4 September 2019

Richard Walls, Celeste Viljoen and Hennie de Clercq

This paper aims to provide a parametric investigation into the behaviour of steel, concrete and composite beams exposed to fire. This investigation gives insight into the…

Abstract

Purpose

This paper aims to provide a parametric investigation into the behaviour of steel, concrete and composite beams exposed to fire. This investigation gives insight into the structural behaviour of elements experiencing thermal and mechanical loading illustrating reasons for observed global structural behaviour, and identifying how selected design parameters influence results obtained. Non-linear heating/thermal bowing behaviour is specifically considered.

Design/methodology/approach

Cross-sectional stresses and strains, resultant thermal forces, bending stiffness, axial stiffness and deflections are plotted for beams subjected to different fire regimes or input values. The impact of changes in input parameters on beam section properties is illustrated. Unusual structural responses, localised effects and general trends are identified in relation to variations in thermal gradients, concrete tensile capacity, standard fire exposure time and the assumed concrete flange widths of composite beams.

Findings

Stress-strain plots highlighting cross-sectional structural behaviour, trends in beam properties and the influence of design parameters are provided. Some counter-intuitive behaviour is explained, such as increased member stiffness being offset by increased thermal effects, leading to this parameter having negligible impact on global behaviour but a significant effect on local stresses and strains. Increased concrete strengths may lead to increased thermal deformations, whilst the inclusion of concrete tensile capacity typically has a minimal influence.

Research limitations/implications

The research focusses on cross-sectional properties, although results generated illustrate how global behaviour is affected.

Practical implications

Design engineers are made aware of how selected input values influence predicted structural response. Also, localised stress and strain behaviour relative to imposed loads and thermal effects can be identified.

Originality/value

This paper provides novel insight into the (sometimes counter-intuitive) behaviour of beams exposed to fire, highlighting trends and the influence of important input parameters on predicted response.

Details

Journal of Structural Fire Engineering, vol. 11 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 August 1999

Jaroslav Mackerle

This paper gives a bibliographical review of the finite element methods (FEMs) applied to the analysis of ceramics and glass materials. The bibliography at the end of the paper…

2607

Abstract

This paper gives a bibliographical review of the finite element methods (FEMs) applied to the analysis of ceramics and glass materials. The bibliography at the end of the paper contains references to papers, conference proceedings and theses/dissertations on the subject that were published between 1977‐1998. The following topics are included: ceramics – material and mechanical properties in general, ceramic coatings and joining problems, ceramic composites, ferrites, piezoceramics, ceramic tools and machining, material processing simulations, fracture mechanics and damage, applications of ceramic/composites in engineering; glass – material and mechanical properties in general, glass fiber composites, material processing simulations, fracture mechanics and damage, and applications of glasses in engineering.

Details

Engineering Computations, vol. 16 no. 5
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 6 February 2024

Andrea Lucherini and Donatella de Silva

Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings…

Abstract

Purpose

Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings are particularly complex materials to be modelled and predicted, which can be extremely useful especially for performance-based fire safety designs. In addition, many parameters influence their performance, and this challenges the definition and quantification of their material properties. Several approaches and models of various complexities are proposed in the literature, and they are reviewed and analysed in a critical literature review.

Design/methodology/approach

Analytical, finite-difference and finite-element methods for modelling intumescent coatings are compared, followed by the definition and quantification of the main physical, thermal, and optical properties of intumescent coatings: swelled thickness, thermal conductivity and resistance, density, specific heat capacity, and emissivity/absorptivity.

Findings

The study highlights the scarce consideration of key influencing factors on the material properties, and the tendency to simplify the problem into effective thermo-physical properties, such as effective thermal conductivity. As a conclusion, the literature review underlines the lack of homogenisation of modelling approaches and material properties, as well as the need for a universal modelling method that can generally simulate the performance of intumescent coatings, combine the large amount of published experimental data, and reliably produce fire-safe performance-based designs.

Research limitations/implications

Due to their limited applicability, high complexity and little comparability, the presented literature review does not focus on analysing and comparing different multi-component models, constituted of many model-specific input parameters. On the contrary, the presented literature review compares various approaches, models and thermo-physical properties which primarily focusses on solving the heat transfer problem through swelling intumescent systems.

Originality/value

The presented literature review analyses and discusses the various modelling approaches to describe and predict the behaviour of swelling intumescent coatings as fire protection for structural materials. Due to the vast variety of available commercial products and potential testing conditions, these data are rarely compared and combined to achieve an overall understanding on the response of intumescent coatings as fire protection measure. The study highlights the lack of information and homogenisation of various modelling approaches, and it underlines the research needs about several aspects related to the intumescent coating behaviour modelling, also providing some useful suggestions for future studies.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 October 2023

N. Keerthi Reddy, Aejung Yoon, Sankar Mani and H.A. Kumara Swamy

Natural convection in finite enclosures is a common phenomenon in various thermal applications. To provide the thermal design guidelines, this study aims to numerically explore…

Abstract

Purpose

Natural convection in finite enclosures is a common phenomenon in various thermal applications. To provide the thermal design guidelines, this study aims to numerically explore the potential of using internal baffles and nanofluids to either enhance or suppress heat transport in a vertical annulus. Furthermore, the annular-shaped enclosure is filled with aqueous-silver nanofluid and the effects of five distinct nanoparticle shapes are examined. In addition, the influence of baffle design parameters, including baffle position, thickness and length, is thoroughly analyzed.

Design/methodology/approach

The finite difference method is used in conjunction with the alternating direction implicit and successive line over relaxation techniques to solve nonlinear and coupled partial differential equations. The single phase model is used for nanofluid which is considered as a homogeneous fluid with improved thermal properties. The independence tests are carried out for assessing the sufficiency of grid size and time step for obtaining results accurately.

Findings

The baffle dimension parameters and nanoparticle shape exhibit significant impact on the convective flow and heat transfer characteristics, leading to the following results: sphere- and blade-shaped nanoparticles demonstrate around 30% enhancement in the heat transport capability compared with platelet-shaped nanoparticles, which exhibit the least. When considering the baffle design parameter, either a decrease in the baffle length and thickness or an increase in baffle height leads to an improvement in heat transport rate. Consequently, a threefold increase in baffle height yields a 40% improvement in thermal performance.

Originality/value

Understanding the impact of nanoparticle shapes and baffle design parameters on flow and thermal behavior will enable engineers to provide valuable insight on thermal management and overall system efficiency. Therefore, the current work focuses on exploring buoyant nanofluid flow and thermal mechanism in a baffled annular-shaped enclosure. Specifically, an internal baffle that exhibits conductive heat transfer through it is considered, and the impact of baffle dimensions (thickness, length and position) on the fluid flow behavior and thermal characteristics is investigated. In addition, the current study also addresses the influence of five distinct nanoparticle shapes (e.g. spherical, cylindrical, platelet, blade and brick) on the flow and thermal behavior in the baffled annular geometry. In addition to deepening the understanding of nanofluid behavior in a baffled vertical annulus, the current study contributes to the ongoing advancements in thermal applications by providing certain guidelines to design application-specific enclosures.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 34 no. 1
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 31 July 2007

Kaiçar Ammous, Slim Abid and Anis Ammous

The paper aims to focus on the semiconductor temperature prediction in the multichip modules by using a simplified 1D model, easy to implement in the electronic simulation tools.

Abstract

Purpose

The paper aims to focus on the semiconductor temperature prediction in the multichip modules by using a simplified 1D model, easy to implement in the electronic simulation tools.

Design/methodology/approach

Accurate prediction of temperature variation of power semiconductor devices in power electronic circuits is important for obtaining optimum designs and estimating reliability levels. Temperature estimation of power electronic devices has generally been performed using transient thermal equivalent circuits. This paper has studied the thermal behaviour of the power modules. The study leads to correcting the junction temperature values estimated from the transient thermal impedance of each component operating alone. The corrections depend on multidimensional thermal phenomena in the structure.

Findings

The classic analysis of thermal phenomena in the multichip structures, independently of powers’ dissipated magnitude and boundary conditions, is not correct. An advanced 1D thermal model based on the finite element method is proposed. It takes into account the effect of the heat‐spreading angle of the different devices in the module.

Originality/value

The paper focuses on mathematical model of the thermal behaviour in the power module. The study leads to a correction of the junction temperature values estimated from the transient thermal impedance of each component given by manufacturers. The proposed model gives a good trade‐off between accuracy, efficiency and simulation cost.

Details

Microelectronics International, vol. 24 no. 3
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 5 April 2024

Fateme Akhlaghinezhad, Amir Tabadkani, Hadi Bagheri Sabzevar, Nastaran Seyed Shafavi and Arman Nikkhah Dehnavi

Occupant behavior can lead to considerable uncertainties in thermal comfort and air quality within buildings. To tackle this challenge, the use of probabilistic controls to…

Abstract

Purpose

Occupant behavior can lead to considerable uncertainties in thermal comfort and air quality within buildings. To tackle this challenge, the use of probabilistic controls to simulate occupant behavior has emerged as a potential solution. This study seeks to analyze the performance of free-running households by examining adaptive thermal comfort and CO2 concentration, both crucial variables in indoor air quality. The investigation of indoor environment dynamics caused by the occupants' behavior, especially after the COVID-19 pandemic, became increasingly important. Specifically, it investigates 13 distinct window and shading control strategies in courtyard houses to identify the factors that prompt occupants to interact with shading and windows and determine which control approach effectively minimizes the performance gap.

Design/methodology/approach

This paper compares commonly used deterministic and probabilistic control functions and their effects on occupant comfort and indoor air quality in four zones surrounding a courtyard. The zones are differentiated by windows facing the courtyard. The study utilizes the energy management system (EMS) functionality of EnergyPlus within an algorithmic interface called Ladybug Tools. By modifying geometrical dimensions, orientation, window-to-wall ratio (WWR) and window operable fraction, a total of 465 cases are analyzed to identify effective control scenarios. According to the literature, these factors were selected because of their potential significant impact on occupants’ thermal comfort and indoor air quality, in addition to the natural ventilation flow rate. Additionally, the Random Forest algorithm is employed to estimate the individual impact of each control scenario on indoor thermal comfort and air quality metrics, including operative temperature and CO2 concentration.

Findings

The findings of the study confirmed that both deterministic and probabilistic window control algorithms were effective in reducing thermal discomfort hours, with reductions of 56.7 and 41.1%, respectively. Deterministic shading controls resulted in a reduction of 18.5%. Implementing the window control strategies led to a significant decrease of 87.8% in indoor CO2 concentration. The sensitivity analysis revealed that outdoor temperature exhibited the strongest positive correlation with indoor operative temperature while showing a negative correlation with indoor CO2 concentration. Furthermore, zone orientation and length were identified as the most influential design variables in achieving the desired performance outcomes.

Research limitations/implications

It’s important to acknowledge the limitations of this study. Firstly, the potential impact of air circulation through the central zone was not considered. Secondly, the investigated control scenarios may have different impacts on air-conditioned buildings, especially when considering energy consumption. Thirdly, the study heavily relied on simulation tools and algorithms, which may limit its real-world applicability. The accuracy of the simulations depends on the quality of the input data and the assumptions made in the models. Fourthly, the case study is hypothetical in nature to be able to compare different control scenarios and their implications. Lastly, the comparative analysis was limited to a specific climate, which may restrict the generalizability of the findings in different climates.

Originality/value

Occupant behavior represents a significant source of uncertainty, particularly during the early stages of design. This study aims to offer a comparative analysis of various deterministic and probabilistic control scenarios that are based on occupant behavior. The study evaluates the effectiveness and validity of these proposed control scenarios, providing valuable insights for design decision-making.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 10 October 2008

Bing Shi and Ye Jin

This paper aims to develop an assembly behaviour dynamic model of reheat stop valve assembly under run‐time situations and combined (assembly error, friction, fluid dynamics and…

Abstract

Purpose

This paper aims to develop an assembly behaviour dynamic model of reheat stop valve assembly under run‐time situations and combined (assembly error, friction, fluid dynamics and thermal load behaviour) and to carry out assembly process evaluation and optimisation.

Design/methodology/approach

The fluid dynamic behaviour analysis is carried out for the dynamic torque characteristics of reheat stop valve and for the thermal load distribution of the valve shaft‐bush subassembly, which is used for evaluating the thermal deformation of valve shaft by using of finite elements method. The assembly behaviour dynamic model is developed by multibody dynamics theory, which is as the basis of developing virtual prototyping platform for analysing and evaluating the current assembly process.

Findings

It is revealed that the deformation (ε) of valve shaft due to the thermal load, and the assembly coaxial error (e) can change the motion clearance remarkably, which lead the dynamic properties and performance of reheat stop valve changed greatly. The current assembly behaviour variable are not optimum and the initial design clearance between valve shaft and bush 4# can be optimised by the developed virtual prototyping platform on the basis of ADAMS® API. The results of evaluation for the assembly behaviour reveal the well dynamic characteristics of reheat stop valve with the optimum assembly behaviour variable. This will be useful for improving the current assembly process of reheat stop valve.

Research limitations/implications

The present assembly behaviour dynamic model based on virtual prototyping for optimum assembly process design uses only single objective optimisation (the most important clearance between valve shaft and bush 4#). For a complete optimum assembly process design has to be carried out with other three clearance variables (the clearance between valve shaft and bush 1#, bush 2# and bush 3#) together.

Practical implications

The present analysis provides some benchmarks for improving the current assembly process. In practice, the assembly coaxial tolerance of valve shaft‐bush subassembly and the initial design clearances must be limited strictly.

Originality/value

This paper provides a methodology for analysis and evaluation of reheat stop valve assembly behaviour with the consideration of combined environmental behaviours. Based on this methodology, it is possible to develop an assembly behaviour dynamic model, and further, to develop a virtual prototyping platform for analysing and evaluating the assembly process which will offer help to designers for improving the reheat stop valve assembly process.

Details

Engineering Computations, vol. 25 no. 7
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 20 July 2023

Yongliang Wang

The purpose of this study is to investigate the unstable propagation of parallel hydraulic fractures induced by interferences of adjacent perforation clusters and thermal

Abstract

Purpose

The purpose of this study is to investigate the unstable propagation of parallel hydraulic fractures induced by interferences of adjacent perforation clusters and thermal diffusion. Fracture propagation in the process of multistage fracturing of a rock mass is deflected owing to various factors. Hydrofracturing of rock masses in deep tight reservoirs involves thermal diffusion, fluid flow and deformation of rock between the rock matrix and fluid in pores and fractures.

Design/methodology/approach

To study the unstable propagation behaviours of three-dimensional (3D) parallel hydraulic fractures induced by the interferences of adjacent perforation clusters and thermal diffusion, a 3D engineering-scale numerical model is established under different fracturing scenarios (sequential, simultaneous and alternate fracturing) and different perforation cluster spacings while considering the thermal-hydro-mechanical coupling effect. Stress disturbance region caused by fracture propagation in a deep tight rock mass is superimposed and overlaid with multiple fractures, resulting in a stress shadow effect and fracture deflection.

Findings

The results show that the size of the stress shadow areas and the interaction between fractures increase with decreasing multiple perforation cluster spacing in horizontal wells. Alternate fracturing can produce more fracture areas and improve the fracturing effect compared with those of sequential and simultaneous fracturing. The larger the temperature gradient between the fracturing fluid and rock matrix, the stronger the thermal diffusion effect, and the effect of thermal diffusion on the fracture propagation is significant.

Originality/value

This study focuses on the behaviours of the unstable dynamic propagation of 3D parallel hydraulic fractures induced by the interferences of adjacent perforation clusters and thermal diffusion. Further, the temperature field affects the fracture deflection requires could be investigated from the mechanisms; this paper is to study the unstable propagation of fractures in single horizontal well, which can provide a basis for fracture propagation and stress field disturbance in multiple horizontal wells.

Details

Engineering Computations, vol. 40 no. 6
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 13 March 2017

Anne-Charlotte Goupil, Jean-Charles Craveur, Benjamin Mercier and Philippe Barabinot

This paper aims to deal with numerical modelling of composite panels of naval industry exposed to fire. Finite element (FE) analyses have been used to study the thermomechanical…

Abstract

Purpose

This paper aims to deal with numerical modelling of composite panels of naval industry exposed to fire. Finite element (FE) analyses have been used to study the thermomechanical behaviour of structures. This paper focuses more particularly on assumptions used to model and evaluate design performance of sandwich panels made of E-Glass vinyl ester and balsawood cored submitted to a certification fire test.

Design/methodology/approach

The methodology consisted of having an advanced understanding of phenomena occurring in both thermal and mechanical behaviours when large structures are degraded under thermal solicitation. Then, properties measuring methods were explored and studied in relation with the size of the structure they are used to describe. Finally, several modelling strategies were compared and applied to large-size panels under ISO 834 fire conditions.

Findings

Research studies and comparisons showed that for these types of material and these types of structure, non-linear thermomechanical behaviour can be performed with a so-called “reduced” thermal model, provided that properties are measured in an appropriate way. “Reduced” model was compared with “full” model, and results were close to experimental measures. A mechanical properties’ review allowed selecting only necessary material FE analysis of large panels under ISO 834 fire.

Originality/value

The research was conducted on real-size structures taking into account the real conditions in which structures are tested when passing certification. Work was carried out on reducing numerical model size without neglecting phenomenon or losing accuracy.

Details

Journal of Structural Fire Engineering, vol. 8 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 29 April 2021

Zul-Atfi Bin Ismail

Improper evaluation and information mismanagement concerning thermal comfort appears to negatively affect occupants' satisfaction and building energy consumption in precast…

Abstract

Purpose

Improper evaluation and information mismanagement concerning thermal comfort appears to negatively affect occupants' satisfaction and building energy consumption in precast concrete (PC) building contexts. Predictive models are particularly problematic in PC building construction projects where natural ventilation levels do not coincide with occupants' thermal comfort and thermal sensation specifications.

Design/methodology/approach

A systematic literature review is undertaken to explore the viability and benefits of a new ICT-based approach for meeting social and environmental objectives.

Findings

Sophisticated thermal comfort system solutions are essential for optimising thermal comfort and saving energy in PC building construction projects.

Originality/value

It is imperative that designers and manufacturers are kept up-to-date with the possibilities and potentials associated with new and nascent technologies so that building projects can meet key sustainability criteria.

Details

Engineering, Construction and Architectural Management, vol. 29 no. 3
Type: Research Article
ISSN: 0969-9988

Keywords

1 – 10 of over 13000