Search results

1 – 10 of 128
Article
Publication date: 30 July 2024

Lijun Wan, Jiaqi Qiao and Quansheng Sun

The application of reinforcing old bridges by adding external prestressed steel bundles is becoming more and more widespread. However, the long-term safety performance test of the…

Abstract

Purpose

The application of reinforcing old bridges by adding external prestressed steel bundles is becoming more and more widespread. However, the long-term safety performance test of the strengthening method is rarely carried out. In this paper, the bearing capacity of a 420 m prestressed concrete (PC) continuous girder bridge after five years of strengthening is analyzed.

Design/methodology/approach

The bridge model of the bridge structure and strengthening scheme is established by the finite element software of the bridge. The theoretical load-bearing capacity of the bridge under the latest standard load grade is obtained by finite element analysis. The actual bearing capacity of the bridge is obtained by field test. Through the comparative analysis of theory and practice, the health state of the bridge after five years of reinforced operation is judged. The damage to the overall stiffness and external prestressing of the bridge is also analyzed.

Findings

The results of deflection and strain show that the stiffness and strength of the secondary side span and the middle span decrease slightly, and the maximum reduction of bearing capacity is 4.5%. The static stiffness of the whole bridge decreases as a result of cracks, and the maximum decrease is 21%. In the past five years, the relaxation loss of the external prestressing of the bridge is 3.31–3.97%, which is the main reason for the decrease in bearing capacity.

Originality/value

Through the joint analysis of the bridge stiffness and the loss of external prestressing, the strengthening condition of the bridge after five years of operation is effectively analyzed. The strengthening effect of the external prestressed steel beam strengthening method is analyzed, which can provide a reference for similar bridge strengthening.

Details

International Journal of Structural Integrity, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 29 March 2024

Aminuddin Suhaimi, Izni Syahrizal Ibrahim and Mariyana Aida Ab Kadir

This review paper seeks to enhance knowledge of how pre-loading affects reinforced concrete (RC) beams under fire. It investigates key factors like deflection and load capacity to…

Abstract

Purpose

This review paper seeks to enhance knowledge of how pre-loading affects reinforced concrete (RC) beams under fire. It investigates key factors like deflection and load capacity to understand pre-loading's role in replicating RC beams' actual responses to fire, aiming to improve fire testing protocols and structural fire engineering design.

Design/methodology/approach

This review systematically aggregates data from existing literature on the fire response of RC beams, comparing scenarios with (WP) and without pre-loading (WOP). Through statistical tools like the two-tailed t-test and Mann–Whitney U-test, it assesses deflection extremes. The study further examines structural responses, including flexural and shear behavior, ultimate load capacity, post-yield behavior, stiffness degradation and failure modes. The approach concludes with a statistical forecast of ideal pre-load levels to elevate experimental precision and enhance fire safety standards.

Findings

The review concludes that pre-loading profoundly affects the fire response of RC beams, suggesting a 35%–65% structural capacity range for realistic simulations. The review also recommended the initial crack load as an alternative metric for determining the pre-loading impact. Crucially, it highlights that pre-loading not only influences the fire response but also significantly alters the overall structural behavior of the RC beams.

Originality/value

The review advances structural fire engineering with an in-depth analysis of pre-loading's impact on RC beams during fire exposure, establishing a validated pre-load range through thorough statistical analysis and examination of previous research. It refines experimental methodologies and structural design accuracy, ultimately bolstering fire safety protocols.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 September 2023

David Krybus, Marcus Achenbach and Livia Prifti

The paper aims to deal with the enhancement of a simplified method for the design of concrete columns subject to fire toward applications on circular and tubular cross-sections…

Abstract

Purpose

The paper aims to deal with the enhancement of a simplified method for the design of concrete columns subject to fire toward applications on circular and tubular cross-sections. The original zone method, developed by Hertz as a plastic design method, has been extended by Achenbach for the use as a nonlinear method. This proposed extended zone method (EZM) is verified by checking the theoretical background and is successfully validated by the recalculation of laboratory tests.

Design/methodology/approach

The zone method assumes a reduction of a cross-section by a “damaged” zone. The remaining area is modeled with the constant, temperature-dependent material properties. The equations for the calculation of the damaged zone to model the loss of cross-section resistance or stiffness are derived. The proposed equations are validated by the recalculation of laboratory test and compared to the results of the advanced method (AM).

Findings

It can be shown that the EZM is suitable for the check of the fire resistance of circular concrete columns and leads to a safe and economic design. The method provides a suitable alternative to more sophisticated AM. The further extension toward tubular spun columns is discussed und is the object of the ongoing research.

Originality/value

Presented enhancement extends the range of applications of the EZMs toward circular and tubular cross sections, which has previously not been examined.

Details

Journal of Structural Fire Engineering, vol. 15 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 April 2024

Fatimah De’nan, Chong Shek Wai, Tong Teong Yen, Zafira Nur Ezzati Mustafa and Nor Salwani Hashim

Brief introduction on the importance and the need for plastic analysis methods were presented in the beginning section of this review. The plastic method for analysis was…

Abstract

Purpose

Brief introduction on the importance and the need for plastic analysis methods were presented in the beginning section of this review. The plastic method for analysis was considered to be the more advanced method of analysis because of its ability to represent the true behaviour of the steel structures. Then in the following section, a literature analysis has been carried out on the previous investigations done on steel plates, steel beams and steel frames by other authors. The behaviour of them under different types of loading were presented and are under the investigation of innovative new analysis methods.

Design/methodology/approach

Structure member connections also have the potential for plastic failure. In this study, the authors have highlighted a few topics to be discussed. The three topics in this study are T-end plate connections to a square hollow section, semi-rigid connections and cold-formed steel storage racks with spine bracings using speed-lock connections. Connection is one of the important parts of a structure that ensures the integrity of the structure. Finally, in this technical paper, the authors introduce some topics related to seismic action. Application of the Theory of Plastic Mechanism Control in seismic design is studied in the beginning. At the end, its in-depth application for moment resisting frames-eccentrically braced frames dual systems is investigated.

Findings

When this study involves the design of a plastic structure, the design criteria must involve the ultimate load rather than the yield stress. As the steel behaves in the plastic range, it means the capacity of the steel has reached the ultimate load. Ultimate load design and load factor design are the methods in the range of plastic analysis. After the steel capacity has reached beyond the yield stress, it fulfills the requirement in this method. The plastic analysis method offers a consistent and logical approach to structural analysis. It provides an economical solution in terms of steel weight, as the sections designed using this method are smaller compared with elastic design methods.

Originality/value

The plastic method is the primary approach used in the analysis and design of statically indeterminate frame structures.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 2 May 2024

Tudor George Alexandru, Diana Popescu, Stochioiu Constantin and Florin Baciu

The purpose of this study is to investigate the thermoforming process of 3D-printed parts made from polylactic acid (PLA) and explore its application in producing wrist-hand…

Abstract

Purpose

The purpose of this study is to investigate the thermoforming process of 3D-printed parts made from polylactic acid (PLA) and explore its application in producing wrist-hand orthoses. These orthoses were 3D printed flat, heated and molded to fit the patient’s hand. The advantages of such an approach include reduced production time and cost.

Design/methodology/approach

The study used both experimental and numerical methods to analyze the thermoforming process of PLA parts. Thermal and mechanical characteristics were determined at different temperatures and infill densities. An equivalent material model that considers infill within a print is proposed. Its practical use was proven using a coupled finite-element analysis model. The simulation strategy enabled a comparative analysis of the thermoforming behavior of orthoses with two designs by considering the combined impact of natural convection cooling and imposed structural loads.

Findings

The experimental results indicated that at 27°C and 35°C, the tensile specimens exhibited brittle failure irrespective of the infill density, whereas ductile behavior was observed at 45°C, 50°C and 55°C. The thermal conductivity of the material was found to be linearly related to the temperature of the specimen. Orthoses with circular open pockets required more time to complete the thermoforming process than those with hexagonal pockets. Hexagonal cutouts have a lower peak stress owing to the reduced reaction forces, resulting in a smoother thermoforming process.

Originality/value

This study contributes to the existing literature by specifically focusing on the thermoforming process of 3D-printed parts made from PLA. Experimental tests were conducted to gather thermal and mechanical data on specimens with two infill densities, and a finite-element model was developed to address the thermoforming process. These findings were applied to a comparative analysis of 3D-printed thermoformed wrist-hand orthoses that included open pockets with different designs, demonstrating the practical implications of this study’s outcomes.

Details

Rapid Prototyping Journal, vol. 30 no. 5
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 24 July 2024

Arthur de Carvalho Cruzeiro, Leonardo Santana, Danay Manzo Jaime, Sílvia Ramoa, Jorge Lino Alves and Guilherme Mariz de Oliveira Barra

This study aims to evaluate in situ oxidative polymerization of aniline (Ani) as a post-processing method to promote extrusion-based 3D printed parts, made from insulating…

Abstract

Purpose

This study aims to evaluate in situ oxidative polymerization of aniline (Ani) as a post-processing method to promote extrusion-based 3D printed parts, made from insulating polymers, to components with functional properties, including electrical conductivity and chemical sensitivity.

Design/methodology/approach

Extrusion-based 3D printed parts of polyethylene terephthalate modified with glycol (PETG) and polypropylene (PP) were coated in an aqueous acid solution via in situ oxidative polymerization of Ani. First, the feedstocks were characterized. Densely printed samples were then used to assess the adhesion of polyaniline (PAni) and electrical conductivity on printed parts. The best feedstock candidate for PAni coating was selected for further analysis. Last, a Taguchi methodology was used to evaluate the influence of printing parameters on the coating of porous samples. Analysis of variance and Tukey post hoc test were used to identify the best levels for each parameter.

Findings

Colorimetry measurements showed significant color shifts in PP samples and no shifts in PETG samples upon pullout testing. The incorporation of PAni content and electrical conductivity were, respectively, 41% and 571% higher for PETG in comparison to PP. Upon coating, the surface energy of both materials decreased. Additionally, the dynamic mechanical analysis test showed minimal influence of PAni over the dynamic mechanical properties of PETG. The parametric study indicated that only layer thickness and infill pattern had a significant influence on PAni incorporation and electrical conductivity of coated porous samples.

Originality/value

Current literature reports difficulties in incorporating PAni without affecting dimensional precision and feedstock stability. In situ, oxidative polymerization of Ani could overcome these limitations. However, its use as a functional post-processing of extrusion-based printed parts is a novelty.

Details

Rapid Prototyping Journal, vol. 30 no. 8
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 26 June 2024

Jian Sun, Junran Huang, Zhonghao Tian, Jinmei Yao, Yang Zhang and Lu Wang

This paper aims to understand the vibration characteristics of full ceramic ball bearings under grease lubrication, reduce the vibration of the bearings and improve their service…

Abstract

Purpose

This paper aims to understand the vibration characteristics of full ceramic ball bearings under grease lubrication, reduce the vibration of the bearings and improve their service life.

Design/methodology/approach

The Hertz contact stiffness formula for full ceramic ball bearings is constructed; the equivalent comprehensive stiffness calculation model and vibration model of full ceramic ball bearings are established. The dynamic characteristic test of full ceramic ball bearing under grease lubrication was carried out by using the bearing life testing machine, and its vibration was measured, and its vibration acceleration root-mean-square was obtained by software calculation and compared with the simulation results.

Findings

At the rotational speed of 12,000 r/min, the root-mean-square value of vibration acceleration is maximum 10.82 m/s2, and the error is also maximum 7.49%. As the rotational speed increases, the oil film stiffness decreases. In the radial load of 600 N, the vibration acceleration root-mean-square is minimum 6.40 m/s2, but its error is maximum 6.56%. As the radial load increases, the vibration of the bearing decreases and then increases, so under certain conditions increasing the radial load can reduce the bearing vibration. With different types of grease, the best preload is also different; low-speed heavy load should be used when the viscosity of the grease is large, and high-speed light load should be used when the choice of smaller viscosity grease is made.

Originality/value

It provides a theoretical basis for the application of full ceramic ball bearings under grease lubrication, which is of great significance for reducing the vibration of bearings as well as enhancing the service life of bearings.

Peer review

The peer review history for this article is available at: https://publons.com/publon/10.1108/ILT-03-2024-0094/

Details

Industrial Lubrication and Tribology, vol. 76 no. 6
Type: Research Article
ISSN: 0036-8792

Keywords

Article
Publication date: 17 September 2024

M. Vishal, K.S. Satyanarayanan, M. Prakash, Rakshit Srivastava and V. Thirumurugan

At this moment, there is substantial anxiety surrounding the fire safety of huge reinforced concrete (RC) constructions. The limitations enforced by test facilities, technology…

Abstract

Purpose

At this moment, there is substantial anxiety surrounding the fire safety of huge reinforced concrete (RC) constructions. The limitations enforced by test facilities, technology, and high costs have significantly limited both full-scale and scaled-down structural fire experiments. The behavior of an individual structural component can have an impact on the entire structural system when it is connected to it. This paper addresses the development and testing of a self-straining preloading setup that is used to perform thermomechanical action in RC beams and slabs.

Design/methodology/approach

Thermomechanical action is a combination of both structural loads and a high-temperature effect. Buildings undergo thermomechanical action when it is exposed to fire. RC beams and slabs are one of the predominant structural members. The conventional method of testing the beams and slabs under high temperatures will be performed by heating the specimens separately under the desired temperature, and then mechanical loading will be performed. This gives the residual strength of the beams and slabs under high temperatures. This method does not show the real-time behavior of the element under fire. In real-time, a fire occurs simultaneously when the structure is subjected to desired loads and this condition is called thermomechanical action. To satisfy this condition, a unique self-training test setup was prepared. The setup is based on the concept of a prestressing condition where the load is applied through the bolts.

Findings

To validate the test setup, two RC beams and slabs were used. The test setup was tested in service load range and a temperature of 300 °C. One of the beams and slabs was tested conventionally with four-point bending and point loading on the slab, and another beam and slab were tested using the preloading setup. The results indicate the successful operation of the developed self-strain preloading setup under thermomechanical action.

Research limitations/implications

Gaining insight into the unpredictable reaction of structural systems to fire is crucial for designing resilient structures that can withstand disasters. However, comprehending the instantaneous behavior might be a daunting undertaking as it necessitates extensive testing resources. Therefore, a thorough quantitative and qualitative numerical analysis could effectively evaluate the significance of this research.

Originality/value

The study was performed to validate the thermomechanical load setup for beams and slabs on a single-bay single-storey RC frame with and without slab under various fire possible scenarios. The thermomechanical load setup for RC members is found to be scarce.

Details

International Journal of Structural Integrity, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 10 November 2023

Varun Sabu Sam, M.S. Adarsh, Garry Robson Lyngdoh, Garry Wegara K. Marak, N. Anand, Khalifa Al-Jabri and Diana Andrushia

The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical…

Abstract

Purpose

The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical properties of steel under fire conditions. It is known that structural steel loses strength and stiffness as temperature increases, particularly above 400 °C. The duration of time in which steel is exposed to high temperatures also has an impact on how much strength it loses. The time-dependent response of steel is critical when estimating load carrying capacity of steel columns exposed to fire. Thus, investigating the structural response of cold-formed steel (CFS) columns is gaining more interest due to the nature of such structural elements.

Design/methodology/approach

In this study, experiments were conducted on two CFS configurations: back-to-back (B-B) channel and toe-to-toe (T-T) channel sections. All CFS column specimens were exposed to different temperatures following the standard fire curve and cooled by air or water. A total of 14 tests were conducted to evaluate the capacity of the CFS sections. The axial resistance and yield deformation were noted for both section types at elevated temperatures. The CFS column sections were modelled to simulate the section's behaviour under various temperature exposures using the general-purpose finite element (FE) program ABAQUS. The results from FE modelling agreed well with the experimental results. Ultimate load of experiment and finite element model (FEM) are compared with each other. The difference in percentage and ratio between both are presented.

Findings

The results showed that B-B configuration showed better performance for all the investigated parameters than T-T sections. A noticeable loss in the ultimate strength of 34.5 and 65.6% was observed at 90 min (986℃) for B-B specimens cooled using air and water, respectively. However, the reduction was 29.9 and 46% in the T-T configuration, respectively.

Originality/value

This research paper focusses on assessing the buckling strength of heated CFS sections to analyse the mode of failure of CFS sections with B-B and T-T design configurations under the effect of elevated temperature.

Details

Journal of Structural Fire Engineering, vol. 15 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 15 July 2024

Georgiy Gusev, Roman Tsvetkov and Igor Shardakov

This study aims to ensure safe operation of buildings in the mining area.

Abstract

Purpose

This study aims to ensure safe operation of buildings in the mining area.

Design/methodology/approach

The strain energy value was taken as one of the parameters characterizing the deformation process at critical stages in these problems and providing a link between them. Based on the data obtained for the structural element of loading diagrams and assessment of the stress–strain state of the structure as a whole, the maximum permissible horizontal deformations of the soil around the foundation are determined, at which the building elements reach the stress–strain state preceding the loss of bearing capacity. For this purpose, a parameter is used that characterizes the deformation process at the stages of critical deformation in these problems and provides a link between them. This parameter is the value of strain energy.

Findings

Based on the obtained force behavior diagrams of structural elements and assessment of the stress–strain state of the structure as a whole, the maximum permissible horizontal ground deformations in the vicinity of the foundation are determined, at which the building elements reach the stress–strain state preceding the loss of bearing capacity.

Originality/value

The research provides new data in the form of regularities of deformation behavior of building structures in the zones of mine workings. These data formed the basis for the normative documentation being developed. The research results were used for the development of internal instructions of a large mining enterprise.

Details

International Journal of Structural Integrity, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1757-9864

Keywords

1 – 10 of 128