Search results
1 – 10 of over 2000Qizhu Yang, Kejian Ma, Huagang Zhang, Yanhui Wei and Ze Xiang
The purpose of this paper is to study the dynamic characteristics and seismic performance of the composite open-web grid floor structure.
Abstract
Purpose
The purpose of this paper is to study the dynamic characteristics and seismic performance of the composite open-web grid floor structure.
Design/methodology/approach
Studied by using mode-superposition response spectrum method and time history analysis method.
Findings
The results show that the vertical mode-superposition response spectrum method is close to the time history analysis method. The floor has strong seismic performance, and the deflection and internal force are not large under vertical seism. The vertical seismic action suggested that 10% of the representative value of gravity load should be used to ensure the safety of the structure.
Originality/value
In the design, the mid-span section should be properly strengthened or the variable section design should be adopted.
Details
Keywords
Xiuyun Zhu, Rong Pan, Jianbo Li and Gao Lin
In recent years, three-dimensional (3D) seismic base isolation system has been studied extensively. This paper aims to propose a new 3D combined isolation bearing (3D-CIB) to…
Abstract
Purpose
In recent years, three-dimensional (3D) seismic base isolation system has been studied extensively. This paper aims to propose a new 3D combined isolation bearing (3D-CIB) to mitigate the seismic response in both the horizontal and vertical directions.
Design/methodology/approach
The new 3D-CIB composed of laminated rubber bearing coupled with combined disk spring bearing (CDSB) was proposed. Comprehensive analysis of constitution and theoretical derivation for 3D-CIB were presented. The advantage of CDSB is that the constitution can be flexibly adjusted according to the requirements of the bearing capacity and vertical stiffness. Hence, four different combinations of CDSB were designed for the 3D-CIB and employed to isolate nuclear reactor building. A comparative study of the seismic response in terms of seismic action, acceleration floor response spectra (FRS), peak acceleration and relative displacement response was carried out.
Findings
3D-CIB can effectively reduce seismic action, FRS and peak acceleration response of the superstructure in both the horizontal and vertical directions. Overall, the horizontal isolation effectiveness of 3D-CIB was slightly influenced by vertical stiffness. The decrease in the vertical stiffness of the 3D-CIB can reduce the vertical FRS and shift the peak values to a lower frequency. The vertical peak acceleration decreased with a decrease in the vertical stiffness. The superstructure exhibited a rocking effect during the earthquake, and the decrease in the vertical stiffness may increase the rocking of the superstructure.
Originality/value
Although the advantage of 3D-CIB is that the vertical stiffness can be flexibly adjusted by different constitutions, the vertical stiffness should be designed by properly accounting for the balance between the isolation effectiveness and displacement response. This study of isolation effectiveness can provide the technical basis for the application of 3D-CIB into real engineering of nuclear power plants.
Details
Keywords
Gangling Hou, Meng Li, Sun Hai, Tianshu Song, Lingshu Wu, Yong Li, Gang Zheng, Feng Shen and Yaodong Chen
Seismic isolation, as an effective risk mitigation strategy of building/bridge structures, is incorporated into AP1000 nuclear power plants (NPPs) to alleviate the seismic damage…
Abstract
Purpose
Seismic isolation, as an effective risk mitigation strategy of building/bridge structures, is incorporated into AP1000 nuclear power plants (NPPs) to alleviate the seismic damage that may occur to traditional structures of NPPs during their service. This is to promote the passive safety concept in the structural design of AP1000 NPPs against earthquakes.
Design/methodology/approach
In conjunction with seismic isolation, tuned-mass-damping (TMD) is integrated into the seismic resistance system of AP1000 NPPs to satisfy the multi-functional purposes. The proposed base-isolation-tuned-mass-damper (BIS-TMD) is studied by comparing the seismic performance of NPPs with four different design configurations (i.e. without BIS, BIS, BIS-TMD and TMD) with the design parameters of the TMD subsystem optimized.
Findings
Such a new seismic protection system (BIS-TMD) is proved to be promising because the advantages of BIS and TMD can be fully used. The benefits of the new structure include effective energy dissipation (i.e. wide vibration absorption band and a stable damping effect), which results in the high performance of NPPs subject to earthquakes with various intensity levels and spectra features.
Originality/value
Parametric studies are performed to demonstrate the seismic robustness (e.g. consistent performance against the changing mass of the water in the gravity liquid tank and mechanical properties) which further ensures that seismic safety requirements of NPPs can be satisfied through the use of BIS-TMD.
Details
Keywords
Md. Habibur Rahman Sobuz, Md. Montaseer Meraz, Ayan Saha, Abu Sayed Mohammad Akid, Noor Md. Sadiqul Hasan, Mizanoor Rahman and Md. Abu Safayet
This study aims to present the variations of optimal seismic control of reinforced cement concrete (RCC) structure using different structural systems. Different third-dimensional…
Abstract
Purpose
This study aims to present the variations of optimal seismic control of reinforced cement concrete (RCC) structure using different structural systems. Different third-dimensional mathematical models are used to examine the responses of multistory flexibly connected frames subjected to earthquake excitations.
Design/methodology/approach
This paper examined a G + 50 multi-storied high-rise structure, which is analyzed using different combinations of moment resistant frames, shear walls, seismic outrigger systems and seismic dampers to observe the effectiveness during ground motion against soft soil conditions. The damping coefficients of added dampers, providing both upper and lower levels are taken into consideration. A finite element modeling and analysis is generated. Then the nature of the structure exposed to ground motion is captured with response spectrum analysis, using BNBC-2020 for four different seismic zones in Bangladesh.
Findings
The response of the structure is investigated according to the amplitude of the displacements, drifts, base shear, stiffness and torsion. The numerical results indicate that adding dampers at the base level can be the most effective against seismic control. However, placing an outrigger bracing system at the middle and top end with shear wall can be the most effective for controlling displacements and drifts.
Originality/value
The response of high-rise structures to seismic forces in Bangladesh’s soft soil conditions is examined at various levels in this study. This study is an original research which contributes to the knowledge to build earthquake resisting high-rises in Bangladesh.
Details
Keywords
Ming Huang, Zhiqiang Zhang, Peizi Wei, Fei Liu and Youliang Ding
In order to make sure of the safety of a long-span suspension bridge under earthquake action, this paper aims to study the traveling wave effect of the bridge under multi-support…
Abstract
Purpose
In order to make sure of the safety of a long-span suspension bridge under earthquake action, this paper aims to study the traveling wave effect of the bridge under multi-support excitation and optimize the semi-active control schemes based on magneto-rheological (MR) dampers considering reference index as well as economical efficiency.
Design/methodology/approach
The finite element model of the long-span suspension bridge is established in MATLAB and ANSYS software, which includes different input currents and semi-active control conditions. Six apparent wave velocities are used to conduct non-linear time history analysis in order to consider the seismic response influence in primary members under traveling wave effect. The parameters α and β, which are key parameters of classical linear optimal control algorithm, are optimized and analyzed taking into account five different combinations to obtain the optimal control scheme.
Findings
When the apparent wave velocity is relatively small, the influence on the structural response is oscillatory. Along with the increase of the apparent wave velocity, the structural response is gradually approaching the response under uniform excitation. Semi-active control strategy based on MR dampers not only restrains the top displacement of main towers and relative displacement between towers and girders, but also affects the control effect of internal forces. For classical linear optimal control algorithm, the values of two parameters (α and β) are 100 and 8 × 10–6 considering the optimal control effect and economical efficiency.
Originality/value
The emphasis of this study is the traveling wave effect of the triple-tower suspension bridge under multi-support excitation. Meanwhile, the optimized parameters of semi-active control schemes using MR dampers have been obtained, providing relevant references in improving the seismic performance of three-tower suspension bridge.
Details
Keywords
Gangling Hou, Yu Liu, Meng Li, Menghan Sun, Feng Sun, Xiuyun Zhu, Rong Pan and Dongyu Zhang
In recent years, a new type of double-layered containment structure of nuclear power plant has been built in China, named ACP1000 NNP. This paper aims to propose a new method to…
Abstract
Purpose
In recent years, a new type of double-layered containment structure of nuclear power plant has been built in China, named ACP1000 NNP. This paper aims to propose a new method to mitigate the seismic responses of this type of the structure.
Design/methodology/approach
The new base isolation structure (BIS)- tuned mass damper (TMD) structure was proposed and implemented only by modifying the connection between various components of NPPs, and the application of this concept design in ACP1000 was skillfully realized.
Findings
The new structure adopts the combination of structural form and function, adopts appropriate amplification of the seismic response of the secondary component, possesses advantages in explicit damping mechanism, good damping effect, robustness of seismic structures, simple implementation process, etc., and meets the special seismic safety requirements of the NPPs.
Originality/value
This seismic and hazard mitigation and BIS-TMD structure can avoid the risk of ACP1000 accidents caused by horizontal earthquakes.
Details
Keywords
The dynamic response of the nuclear power plants (NPPs) with pile foundation reinforcement have not yet been systemically investigated in detail. Thus, there is an urgent need to…
Abstract
Purpose
The dynamic response of the nuclear power plants (NPPs) with pile foundation reinforcement have not yet been systemically investigated in detail. Thus, there is an urgent need to improve evaluation methods for nonlithological foundation reinforcements, as this issue is bound to become an unavoidable task.
Design/methodology/approach
A nonlinear seismic wave input method is adopted to consider both a nonlinear viscoelastic artificial boundary and the nonlinear properties of the overburden layer soil. Subsequently, the effects of certain vital parameters on the structural response are analyzed.
Findings
A suitable range for the size of the overburden foundation is suggested. Then, when piles are used to reinforce the overburden foundation, the peak frequencies in the floor response spectra (FRS) in the horizontal direction becomes higher (38%). Finally, the Poisson ratio of the foundation soil has a significant influence on the FRS peak frequency in the vertical direction (reduce 35%–48%).
Originality/value
The quantifiable results are performed to demonstrate the seismic responses with respect to key design parameters, including foundational dimensions, the Poisson Ratio of the soil and the depth of the foundation. The results can help guide the development of seismic safety requirements for NPPs.
Details
Keywords
Faisal Mehraj Wani, Jayaprakash Vemuri and Rajaram Chenna
The objective of the study is to examine the response of reinforced concrete (RC) structures subjected to Near-Fault Ground Motions (NFGM) and highlight the importance of…
Abstract
Purpose
The objective of the study is to examine the response of reinforced concrete (RC) structures subjected to Near-Fault Ground Motions (NFGM) and highlight the importance of considering various factors including the influence of the relative geographical position of near-fault sites that can affect the structural response during an earthquake.
Design/methodology/approach
In this paper, the response of a four-storey RC building subjected to NFGMs with varied characteristics like hanging wall and footwall in conjunction with directivity and the effect of pulse-like ground motions with rupture direction are investigated to understand the combined influence of these factors on the behavior of the structure. Furthermore, the capacity and demand of the structural element are investigated for computing the performance ratio.
Findings
Results from this study indicate that the most unfavorable combinations for structural damage due to near-fault ground motion are the hanging wall with forward rupture, the fault normal component of ground motions, and pulse-like ground motions with forward directivity.
Originality/value
The results from this study provide valuable insight into the response of RC structures subjected to NFGM and highlight the importance of considering various factors that can affect the structural response during an earthquake. Moreover, the computation of capacity and demand of the critical beam indicates exceedance of desired limits, resulting in the early deterioration of the structural elements. Finally, the analytical analysis from the present study confirms that the hanging wall with forward ruptures, pulse-like motions, and fling steps are the most unfavorable combinations for seismic structural damage.
Details
Keywords
Gangling Hou, Yu Liu, Tao Wang, Binsheng Wang, Tianshu Song, Menghan Sun and Yong Li
An inter-story isolation structure (IIS) for AP1000 nuclear power plants (NPPs) is provided to resolve the conflict of seismic safety and the optimal location of air intakes.
Abstract
Purpose
An inter-story isolation structure (IIS) for AP1000 nuclear power plants (NPPs) is provided to resolve the conflict of seismic safety and the optimal location of air intakes.
Design/methodology/approach
The effect of passive cooling system (PCS) is better with lower altitude of air intakes than that in the original design of AP1000 NPPs. Seismic performances of IIS NPPs, including the seismic responses, damping frequency bandwidth and seismic reduction robustness, are improved by combining the position of air intakes lower and the optimal design method.
Findings
Theoretical analysis and numerical simulation are illustrated that the seismic reduction failure of IIS NPPs is the lowest probability of occurrence when PCS has highest working efficiency.
Originality/value
The IIS NPPs can transfer the contradiction between PCS work efficiency and seismic safety of NPPs to the mutual promotion of them.
Details
Keywords
Chunli Li, Liang Li, Yungming Cheng, Liang Xu and Guangming Yu
This paper aims to develop an efficient algorithm combining straightforward response surface functions with Monte Carlo simulation to conduct seismic reliability analysis in a…
Abstract
Purpose
This paper aims to develop an efficient algorithm combining straightforward response surface functions with Monte Carlo simulation to conduct seismic reliability analysis in a systematical way.
Design/methodology/approach
The representative slip surfaces are identified and based on to calibrate multiple response surface functions with acceptable accuracy. The calibrated response surfaces are used to determine the yield acceleration in Newmark sliding displacement analysis. Then, the displacement-based limit state function is adopted to conduct seismic reliability analysis.
Findings
The calibrated response surface functions have fairly good accuracy in predicting the yield acceleration in Newmark sliding displacement analysis. The seismic reliability is influenced by such factors as PGA, spatial variability and threshold value. The proposed methodology serves as an effective tool for geotechnical practitioners.
Originality/value
The multiple sources of a seismic slope response can be effectively determined using the multiple response surface functions, which are easily implemented within geotechnical engineering.
Details