Search results

1 – 10 of over 3000
Article
Publication date: 29 August 2023

Erik Velasco and Elvagris Segovia

Waiting for a bus may represent a period of intense exposure to traffic particles in hot and noisy conditions in the street. To lessen the particle load and tackle heat in bus…

Abstract

Purpose

Waiting for a bus may represent a period of intense exposure to traffic particles in hot and noisy conditions in the street. To lessen the particle load and tackle heat in bus stops a shelter was equipped with an electrostatic precipitator and a three-step adiabatic cooling system capable of dynamically adjust its operation according to actual conditions. This study evaluates the effectiveness of the Airbitat Oasis Smart Bus Stop, as the shelter was called, to provide clean and cool air.

Design/methodology/approach

The particle exposure experienced in this innovative shelter was contrasted with that in a conventional shelter located right next to it. Mass concentrations of fine particles and black carbon, and particle number concentration (as a proxy of ultrafine particles) were simultaneously measured in both shelters. Air temperature, relative humidity and noise level were also measured.

Findings

The new shelter did not perform as expected. It only slightly reduced the abundance of fine particles (−6.5%), but not of ultrafine particles and black carbon. Similarly, it reduced air temperature (−1 °C), but increased relative humidity (3%). Its operation did not generate additional noise.

Practical implications

The shelter's poor performance was presumably due to design flaws induced by a lack of knowledge on traffic particles and fluid dynamics in urban environments. This is an example where harnessing technology without understanding the problem to solve does not work.

Originality/value

It is uncommon to come across case studies like this one in which the performance and effectiveness of urban infrastructure can be assessed under real-life service settings.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 16 June 2021

Shirun Ding and Bing Feng Ng

This study aims to examine on-site particle concentration levels due to emissions from a wide spectrum of additive manufacturing techniques, including polymer-based material…

Abstract

Purpose

This study aims to examine on-site particle concentration levels due to emissions from a wide spectrum of additive manufacturing techniques, including polymer-based material extrusion, metal and polymer-based powder bed fusion, directed energy deposition and ink-based material jetting.

Design/methodology/approach

Particle concentrations in the operating environments of users were measured using a combination of particle sizers including the TSI 3910 Nano SMPS (10–420 nm) and the TSI 3330 optical particle sizer (0.3–10 µm). Also, fumes from a MEX printer during printing were directly captured using laser imaging method.

Findings

The number and mass concentration of submicron particles emitted from a desktop open-type MEX printer for acrylonitrile-butadiene-styrene and polyvinyl alcohol approached and significantly exceeded the nanoparticle reference limits, respectively. Through laser imaging, fumes were observed to originate from the printer nozzle and from newly deposited layers of the desktop MEX printer. On the other hand, caution should be taken in the pre-processing of metal and polymer powder. Specifically, one to ten micrometers of particles were observed during the sieving, loading and cleaning of powder, with transient mass concentrations ranging between 150 and 9,000 µg/m3 that significantly exceeded the threshold level suggested for indoor air quality.

Originality/value

Preliminary investigation into possible exposures to particle emissions from different 3D printing processes was done, which is useful for the sustainable development of the 3D printing industry. In addition, automatic processes that enable “closed powder cycle” or “powder free handling” should be adopted to prevent users from unnecessary particle exposure.

Details

Rapid Prototyping Journal, vol. 27 no. 6
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 2 October 2019

Mansoor Ahmad, Ayhan Bozkurt and Omid Farhanieh

This paper aims to Separation and sorting of biological cells is desirable in many applications for analyzing cell properties, such as disease diagnostics, drugs delivery…

328

Abstract

Purpose

This paper aims to Separation and sorting of biological cells is desirable in many applications for analyzing cell properties, such as disease diagnostics, drugs delivery, chemical processing and therapeutics.

Design/methodology/approach

Acoustic energy-based bioparticle separation is a simple, viable, bio-compatible and contact-less technique using, which can separate the bioparticles based on their density and size, with-out labeling the sample particles.

Findings

Conventionally available bioparticle separation techniques as fluorescence and immunomagnetic may cause a serious threat to the life of the cells due to various compatibility issues. Moreover, they also require an extra pre-processing labeling step. Contrarily, label-free separation can be considered as an alternative solution to the traditional bio-particle separation methods, due to their simpler operating principles and lower cost constraints. Acoustic based particle separation methods have captured a lot of attention among the other reported label-free particle separation techniques because of the numerous advantages it offers.

Practical implications

This study tries to briefly cover the developments of different acoustic-based particle separation techniques over the years. Unlike the conventional surveys on general bioparticles separation, this study is focused particularly on the acoustic-based particle separation. The study would provide a comprehensive guide for the future researchers especially working in the field of the acoustics, in studying and designing the acoustic-based particle separation techniques.

Originality/value

The study insights a brief theory of different types of acoustic waves and their interaction with the bioparticles is considered, followed by acoustic-based particle separation devices reported till the date. The integration of acoustic-based separation techniques with other methods and with each other is also discussed. Finally, all major aspects like the approach, and productivity, etc., of the adopted acoustic particle separation methods are sketched in this article.

Details

World Journal of Engineering, vol. 16 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 26 June 2018

Sonette Du Preez, Alyson Johnson, Ryan F. LeBouf, Stephanus J.L. Linde, Aleksandr B. Stefaniak and Johan Du Plessis

This paper aims to measure exposures to airborne contaminants during three-dimensional (3-D) printing and post-processing tasks in an industrial workplace.

Abstract

Purpose

This paper aims to measure exposures to airborne contaminants during three-dimensional (3-D) printing and post-processing tasks in an industrial workplace.

Design/methodology/approach

Contaminant concentrations were assessed using real-time particle number (0.007 to 1 µm) and total volatile organic compound (TVOC) monitors and thermal desorption tubes during various tasks at a manufacturing facility using fused deposition modeling (FDMTM) 3-D printers. Personal exposures were measured for two workers using nanoparticle respiratory deposition samplers for metals and passive badges for specific VOCs.

Findings

Opening industrial-scale FDMTM 3-D printer doors after printing, removing desktop FDMTM 3-D printer covers during printing, acetone vapor polishing (AVP) and chloroform vapor polishing (CVP) tasks all resulted in transient increases in levels of submicrometer-scale particles and/or organic vapors, a portion of which enter the workers’ breathing zone, resulting in exposure. Personal exposure to quantifiable levels of metals in particles <300 nm were 0.02 mg/m3 for aluminum, chromium, copper, iron and titanium during FDMTM printing. Personal exposures were 0.38 to 6.47 mg/m3 for acetone during AVP and 0.18 mg/m3 for chloroform during CVP.

Originality/value

Characterization of tasks provided insights on factors that influenced contaminant levels, and in turn exposures to various particles, metals < 300 nm and organic vapors. These concentration and exposure factors data are useful for identifying tasks and work processes to consider for implementation of new or improved control technologies to mitigate exposures in manufacturing facilities using FDMTM 3-D printers.

Details

Rapid Prototyping Journal, vol. 24 no. 5
Type: Research Article
ISSN: 1355-2546

Keywords

Open Access
Article
Publication date: 11 November 2022

Sara Zanni, Matteo Mura, Mariolina Longo, Gabriella Motta and Davide Caiulo

This study aims to provide a comprehensive framework for the study of indoor air quality (IAQ) in hospitality premises. The goal is to identify the drivers of air pollution, both…

1856

Abstract

Purpose

This study aims to provide a comprehensive framework for the study of indoor air quality (IAQ) in hospitality premises. The goal is to identify the drivers of air pollution, both at the exogenous and endogenous level, to generate insights for facility managers.

Design/methodology/approach

The complexity of hospitality premises requires an integrated approach to properly investigate IAQ. The authors develop an overarching framework encompassing a monitoring method, based on real-time sensors, a technological standard and a set of statistical analyses for the assessment of both IAQ performance and drivers, based on correlation analyses, analysis of variance and multivariate regressions.

Findings

The findings suggest that the main drivers of IAQ differ depending on the area monitored: areas in contact with the outdoors or with high ventilation rates, such as halls, are affected by outdoor air quality more than guestrooms or fitness areas, where human activities are the main sources of contamination.

Research limitations/implications

The results suggest that the integration of IAQ indicators into control dashboards would support management decisions, both in defining protocols to support resilience of the sector in a postpandemic world and in directing investments on the premises. This would also address guests’ pressing demands for a broader approach to cleanliness and safety and support their satisfaction and intention to return.

Originality/value

To the best of the authors’ knowledge, this is the first study developing a comprehensive framework to systematically address IAQ and its drivers, based on a standard and real-time monitoring. The framework has been applied across the longest period of monitoring for a hospitality premise thus far and over an entire hotel facility.

Details

International Journal of Contemporary Hospitality Management, vol. 35 no. 2
Type: Research Article
ISSN: 0959-6119

Keywords

Article
Publication date: 19 May 2012

M. Jariyaboon, P. Møller and R. Ambat

The purpose of this paper is to understand the effect of pressurized steam on surface changes, structures of intermetallic particles and corrosion behavior of AA1050 aluminium.

Abstract

Purpose

The purpose of this paper is to understand the effect of pressurized steam on surface changes, structures of intermetallic particles and corrosion behavior of AA1050 aluminium.

Design/methodology/approach

Industrially pure aluminium (AA1050, 99.5 per cent) surfaces were exposed to pressurized steam produced from a commercial pressure cooker at the maximum temperature of 116oC for 10 min. Surface morphology was observed using SEM‐EDX and FIB‐SEM. Phase identification and compositional depth profiling were investigated using XRD and GDOES, respectively. Potentiodynamic polarization measurements were used to study corrosion behavior.

Findings

A 590 nm boehmite oxide layer was generated on AA1050 associated with partially dissolved and/or fallen off Fe‐containing intermetallic particles after exposure to pressurized steam. A significant reduction (25 times) in anodic and cathodic reactivities was observed due to the formation of the compact oxide layer.

Originality/value

This paper reveals a detailed investigation of how pressurized steam can affect the corrosion behaviour of AA1050 aluminium and the structure of Fe‐containing intermetallic particles.

Details

Anti-Corrosion Methods and Materials, vol. 59 no. 3
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 25 May 2023

Mohammed Alhaji Mohammed, Kyari Bulama, Alhaji Modu Bukar, Mala Ali Modu, Audu Alhaji Usman, Alhaji Kasir Lawan and Garba Abba Habib

The effects of dust exposure in buildings and its health and comfort consequences continue to concern occupants, particularly those who spend most of their time indoors. This…

Abstract

Purpose

The effects of dust exposure in buildings and its health and comfort consequences continue to concern occupants, particularly those who spend most of their time indoors. This study examines the influence of building opening characteristics on surface dust loading in indoor environments to determine the dust particles' impact on different opening configurations.

Design/methodology/approach

Indoor Harmattan dust surface loading data were collected from Maiduguri, Northeastern Nigeria, using model rooms with six different window configurations. A simple mathematical relationship was employed to assess surface dust loading characteristics in the model rooms. The study measured dust thrice between December and February for three days (72 h). The results were analyzed using descriptive statistics.

Findings

The results determined the highest average surface dust loading of 12.03 g/m2 in the room with awning windows at an indoor-to-outdoor (I/O) ratio of 0.7. In contrast, the experiment in the room with a closed window recorded the lowest average surface dust loading of 5.24 g/m2 at an I/O ratio of 0.30, which is infiltration. The outcomes further indicate that the average surface dust loading varies with the building opening type and position, as higher surface dust loadings were recorded in locations closer to the openings (doors and windows), reaffirming that the dominant source of the dust particles is outdoors. According to the study, dust incursion due to infiltration accounts for 30% of the outdoor surface loading.

Originality/value

Thus, Harmattan dust is a serious challenge to the health, productivity and hygiene of building occupants in the study area. The built-environment professionals must use the study's outcome to optimize building openings' designs (shape, size and form) for effective indoor dust control.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 24 March 2022

Kevin Gildas Dongmo Tambah, Jean-Pierre Kenné and Victor Songmene

This paper studies the integration of production and maintenance planning for an unreliable production system subject to gradual deterioration. The goal of this planning is to…

Abstract

Purpose

This paper studies the integration of production and maintenance planning for an unreliable production system subject to gradual deterioration. The goal of this planning is to optimize production and maintenance while reducing workers' exposure to silica dust. The objective will therefore be to offer manufacturers a production strategy that minimizes the total cost of production while considering the health of employees.

Design/methodology/approach

Adequate prevention methods are determined and integrated into the granite transformation production system, which evolves in a stochastic environment. With the failure rate of the dust reduction unit being a function of its degradation state, the authors solve the optimization problem using stochastic dynamic programming in the context of nonhomogeneous Markov chain.

Findings

The resulting planning strategy shows that one can manage stock optimally while ensuring a healthy environment for workers. It ensures that crystalline silica prevention equipment is available and effective and defines the production rate according to a critical threshold, which is a function of the age of the dust reduction unit.

Research limitations/implications

This article illustrates that it is possible to integrate silica dust reduction measures into production planning while remaining optimal and ensuring the health of operators. In the present study, the machined granite was assumed to be a natural granite, and production takes place in a closed environment.

Originality/value

The originality of this work lies in its development of an optimal joint production and maintenance strategy, which considers limits of exposure to crystalline silica. An optimal production and maintenance control policy considering employees' health is therefore proposed.

Details

Journal of Quality in Maintenance Engineering, vol. 29 no. 1
Type: Research Article
ISSN: 1355-2511

Keywords

Article
Publication date: 1 October 2004

A. Ul‐Hamid, H.M. Tawancy, A.I. Mohammed, S.S. Al‐Jaroudi and N.M. Abbas

The oxidation behaviour of a wrought Ni‐Mo‐Cr alloy was studied under thermal cyclic conditions in air at 800°C for exposure periods of up to 1,000 h. The morphologies…

Abstract

The oxidation behaviour of a wrought Ni‐Mo‐Cr alloy was studied under thermal cyclic conditions in air at 800°C for exposure periods of up to 1,000 h. The morphologies, microstructures and compositions of the oxide scales were characterized by scanning electron microscopy, energy dispersive X‐ray spectroscopy and X‐ray diffraction. Oxidation kinetics were determined by weight gain measurements. Results show that steady‐state oxidation was achieved within 1 h of exposure while partial scale spalling was observed after 400 h. The alloy grain boundaries intersecting the alloy surface showed preferential oxidation. They became depleted in Ni and enriched in Mo and Cr during transient oxidation. The scale initially formed at the surface was NiO which grew outwardly and laterally to cover the entire alloy. Upon continued oxidation, the scale developed into an outer NiO layer and an inner Cr2O3 layer while the presence of NiMoO4 was also observed within the scale.

Details

Anti-Corrosion Methods and Materials, vol. 51 no. 5
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 6 July 2020

Ehsan Mousavi, Vivek Sharma, Dhaval Gajjar and Shervin Shoai Naini

The purpose of this study is to evaluate the effectiveness of the control cubes for dust control in health-care facilities. Research shows that more than 80% of pathogenic agents…

Abstract

Purpose

The purpose of this study is to evaluate the effectiveness of the control cubes for dust control in health-care facilities. Research shows that more than 80% of pathogenic agents in hospitals are spread into the air, where they either remain airborne or deposit on the surface. At the same time, renovation and repair activities, including regular maintenance, are a necessity in active health-care facilities and a multitude of studies have documented their impact on indoor air quality. The dust that is generated by construction activities may potentially carry pathogenic agents, varying from coarse particles (≤10 µm, PM10) to fine particles (≤2.5 µm, PM2.5), including airborne bacteria, and fungal spores linked to high patient mortality in immune-compromised patients.

Design/methodology/approach

This study measures the impact and effectiveness of one such preventative measure, namely, the control cube (CC), on air quality during renovation and repair. CC is a temporary structure, typically made from stainless steel, around the local repair zone to minimize the spread of dust and potential microorganisms. The current paper presents a comparative analysis to identify the effectiveness of a CC equipped with the high-efficiency particulate filtration (HEPA) filter in a hospital setting by simulating construction renovation and repair work.

Findings

A baseline was established to measure the effectiveness of CCs and the impact of negative pressure on the indoor air quality in a hospital during simulated renovation work. Results showed that CCs are very effective in minimizing the spread of dust due to construction activities in the hospital. However, it is imperative to ensure that the air inside the CC is cleaned via filtration.

Originality/value

CCs are very effective, and this paper investigates the best approach for facility managers to implement this strategy.

Details

Journal of Facilities Management , vol. 18 no. 3
Type: Research Article
ISSN: 1472-5967

Keywords

1 – 10 of over 3000