Article
Publication date: 15 May 2023

Jakub Šejna, Patrik Dobrovolný and František Wald

This paper provides a summary of the issues in the passive fire protection of steel structures. Types of passive fire protection and the material properties of protection members…

Abstract

Purpose

This paper provides a summary of the issues in the passive fire protection of steel structures. Types of passive fire protection and the material properties of protection members and steel members are described. The paper deals with the possibility of partial fire protection for secondary steel beams, in cases where, due to possible membrane action, it is not necessary to apply passive protection to the entire beams.

Design/methodology/approach

Studies of partially fire-protected steel structures are compared, and results from studies with different input data are summarized. A fire experiment was conducted to investigate the effect of partial passive protection in a small-scale furnace. Based on the findings of the experiment, numerical models were prepared using Ansys Mechanical.

Findings

The results are summarized, and a partial fire protection length of 500 mm is recommended. Various partial fire protection lengths were compared, and the temperature development of the steel contactors was compared using a protection length of 500 mm. At the end of the paper, options for partial passive protection of steel beams are presented.

Originality/value

Extended paper from ASFE2021 based on selection.

Details

Journal of Structural Fire Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 28 February 2019

Ataollah Taghipour Anvari, Mustafa Mahamid, Michael McNallan and Mohammadreza Eslami

The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the…

Abstract

Purpose

The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the fire rating of members significantly. Damaged fireproofing happens in structures due to various reasons, and the question is always how effective is this fireproofing? This paper presents the results of one type of fireproofing and presents a parametric study on the size of damage and its effect on fire resistance of structural steel members.

Design/methodology/approach

The study has been performed using numerical methods, thermal and structural finite element analysis. The analysis method has been verified by experimental results.

Findings

Small fire protection damage or loss leads to significant rise of temperature at the damaged parts and causes severe fire resistance reduction of beams. The higher fire protection damage’s extension at the bottom flange of the steel beams does not have any major influence on the rate of reduction of fire resistance of the beams. Steel beams experience greater fire resistance reduction at higher load levels because of the existing of higher stresses and loads within the steel beam section.

Research limitations/implications

The study has been performed using finite element analysis, and it covers a wide range of practical sizes. However, experimental work will be performed by the researchers when funding is granted.

Practical implications

The study provides researchers and practitioners with an estimate on the effect of damaged fireproofing on fire resistance of structural steel beams.

Social implications

Understanding the effect of the effect of damaged fireproofing helps in estimating the fire resistance of structural steel members, which may protect collapses and disasters.

Originality/value

The research is original; extensive literature review has been performed, and this research is original.

Details

Journal of Structural Fire Engineering, vol. 10 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 23 January 2019

Mustafa Mahamid, Ataollah Taghipour Anvari, Ines Torra-Bilal, Tom Brindley and Michael McNallan

The purpose of this paper is to investigate different types of fire on structural steel members with damaged fireproofing. Two types of fire scenarios are considered, ASTM E119…

195

Abstract

Purpose

The purpose of this paper is to investigate different types of fire on structural steel members with damaged fireproofing. Two types of fire scenarios are considered, ASTM E119 fire and Hydrocarbon fire. In industrial facilities such as oil refineries, certain units maybe subjected to hydrocarbon fire, and its effect might be different than standard fire. The purpose of this study is to compare both types of fire scenarios on steel beams with damaged fireproofing and determine the fire rating of the damaged beams under each fire scenario.

Design/methodology/approach

The study is performed using computational methods, thermal-stress finite element analysis that is validated with experimental results. The results of practical beam sizes and typical applied loads in such structures have been plotted and compared with steel beams with non-damaged fireproofing.

Findings

The results show significant difference in the beam fire resistance between the two fire scenarios and show the fire resistance for beam under each case. The study provides percentage reduction in fire resistance under each case for the most commonly used cases in practice under different load conditions.

Originality/value

Extensive literature search has been performed by the authors, and few studies were found relevant to the topic. The question this study answers comes up regularly in practice. There are no standards to codes that address this issue.

Details

Journal of Structural Fire Engineering, vol. 10 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 7 September 2023

Jakub Šejna, Stanislav Šulc, Vít Šmilauer, Pavel Reiterman and František Wald

The aim of this paper is to determine the thermal conductivity of a protective layer of alkali-activated cement and the possibility of performing fire protection with fireclay…

Abstract

Purpose

The aim of this paper is to determine the thermal conductivity of a protective layer of alkali-activated cement and the possibility of performing fire protection with fireclay sand and Lightweight mortar. Unprotected steel structures have generally low fire resistance and require surface protection. The design of passive protection of a steel element must consider the service life of the structure and the possible need to replace the fire protection layer. Currently, conventional passive protection options include intumescent coatings, which are subject to frequent inspection and renewal, gypsum and cement-based fire coatings and gypsum and cement board fire protection.

Design/methodology/approach

Alkali-activated cements provide an alternative to traditional Portland clinker-based materials for specific areas. This paper presents the properties of hybrid cement, its manufacturability for conventional mortars and the development of passive fire protection. Fire experiments were conducted with mortar with alkali-activated and fireclay sand and lightweight mortar with alkali-activated cement and expanded perlite. Fire experiment FE modelling.

Findings

The temperatures of the protected steel and the formation of cracks in the protective layer were investigated. Based on the experiments, the thermal conductivities of the two protective layers were determined. Conclusions are presented on the applicability of alkaline-activated cement mortars and the possibilities of applicability for the protection of steel structures. The functionality of the passive fire layer was confirmed and the strengths of the mortar used were determined. The use of alkali-activated cements was shown to be a suitable option for sustainable passive fire protection of steel structures.

Originality/value

Eco-friendly fire protection based on hybrid alkali-activated cement of steel members.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 December 2019

Fariz Aswan Ahmad Zakwan, Ruqayyah Ismail, Renga Rao Krishnamoorthy and Azmi Ibrahim

This paper aims to investigate the predicted temperature behaviour of the protected cellular steel beam (CSB) with circular web openings at elevated temperature through finite…

Abstract

Purpose

This paper aims to investigate the predicted temperature behaviour of the protected cellular steel beam (CSB) with circular web openings at elevated temperature through finite element simulation.

Design/methodology/approach

Temperature development along the CSB were analysed and used for parametric investigation. In addition, this research paper investigates the novelty application of various intumescent coating thicknesses covering the whole CSB to cut down the temperature development along the beam section.

Findings

From the simulation outcomes, it shows that intumescent coating has a significant effect in reducing the temperature development along the CSB section. Thicker intumescent coating contributes to a higher temperature drop at the bottom tee section than the upper tee section.

Originality/value

The use of structural CSB has gained popularity among engineers and architects. This type of beam allows serviceability ducts and pipes to pass through the main steel web section under the flooring system, thus providing larger headroom for designers. Nevertheless, in any structural steel building, it is highly risky for CSB to be exposed to fire hazard if it were triggered accidentally. To mitigate and reduce fire exposure risk which might compromise the strength and stiffness of CSB, a passive fire protection is proposed to minimise the risk. One of the common passive fire protection materials used for steel beam section is intumescent coating. Intumescent coating is by far the cheapest solution to protect CSB as compared to other passive fire protection system. Intumescent coating can absorb some portion of heat exposure which subsequently translates a lower temperature development along the CSB section.

Details

Journal of Structural Fire Engineering, vol. 11 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 6 February 2024

Andrea Lucherini and Donatella de Silva

Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings…

Abstract

Purpose

Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings are particularly complex materials to be modelled and predicted, which can be extremely useful especially for performance-based fire safety designs. In addition, many parameters influence their performance, and this challenges the definition and quantification of their material properties. Several approaches and models of various complexities are proposed in the literature, and they are reviewed and analysed in a critical literature review.

Design/methodology/approach

Analytical, finite-difference and finite-element methods for modelling intumescent coatings are compared, followed by the definition and quantification of the main physical, thermal, and optical properties of intumescent coatings: swelled thickness, thermal conductivity and resistance, density, specific heat capacity, and emissivity/absorptivity.

Findings

The study highlights the scarce consideration of key influencing factors on the material properties, and the tendency to simplify the problem into effective thermo-physical properties, such as effective thermal conductivity. As a conclusion, the literature review underlines the lack of homogenisation of modelling approaches and material properties, as well as the need for a universal modelling method that can generally simulate the performance of intumescent coatings, combine the large amount of published experimental data, and reliably produce fire-safe performance-based designs.

Research limitations/implications

Due to their limited applicability, high complexity and little comparability, the presented literature review does not focus on analysing and comparing different multi-component models, constituted of many model-specific input parameters. On the contrary, the presented literature review compares various approaches, models and thermo-physical properties which primarily focusses on solving the heat transfer problem through swelling intumescent systems.

Originality/value

The presented literature review analyses and discusses the various modelling approaches to describe and predict the behaviour of swelling intumescent coatings as fire protection for structural materials. Due to the vast variety of available commercial products and potential testing conditions, these data are rarely compared and combined to achieve an overall understanding on the response of intumescent coatings as fire protection measure. The study highlights the lack of information and homogenisation of various modelling approaches, and it underlines the research needs about several aspects related to the intumescent coating behaviour modelling, also providing some useful suggestions for future studies.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 9 February 2022

Naoya Yotsumoto, Takeo Hirashima and Koji Toyoda

This paper aims to investigate the fire performance of composite beams when considering the hogging moment resistance of the fin-plate beam-to-girder joints including the effect…

Abstract

Purpose

This paper aims to investigate the fire performance of composite beams when considering the hogging moment resistance of the fin-plate beam-to-girder joints including the effect of continuity of reinforcements.

Design/methodology/approach

Experiments on composite beams with fin-plate joints protected only at the beam ends are conducted. The test parameter is the specification of reinforcement, which affects the rotational restraint of the beam ends. In addition, a simple method for predicting the failure time of the beam using an evaluation model based on the bending moment resistance of the beam considering the hogging moment resistance of the fin-plate joint and the reinforcement is also presented.

Findings

The test results indicate that the failure time of the beam is extended by the hogging moment resistance of the joints. This is particularly noticeable when using a reinforcing bar with a large plastic deformation capability. The predicted failure times based on the evaluation method corresponded well with the test results.

Originality/value

Recent studies have proposed large deformation analysis methods using FEM that can be used for fire-resistant design of beams including joints, but these cannot always be applicable in practice due to the cost and its complexity. Our method can consider the hogging moment resistance of the joint and the temperature distribution in the axial direction using a simple method without requirement of FEM.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 17 June 2014

Gisèle Bihina, Bin Zhao and Abdelhamid Bouchaïr

The main results from a numerical investigation on a composite floor made of cellular beams at elevated temperatures are presented. From a full-scale natural fire test, a 3D…

Abstract

The main results from a numerical investigation on a composite floor made of cellular beams at elevated temperatures are presented. From a full-scale natural fire test, a 3D finite element model has been developed under ANSYS code to simulate the thermo-mechanical behaviour of a composite floor with cellular beams. The calibration of this numerical model is based on the measured material properties and temperatures. A good correlation between the test and the numerical simulation is observed, in terms of temperatures, deformed shape and deflections. The finite element model is then used in a parametric study varying bay size, mechanical load and fire resistance rate. The results from this parametric study are compared to those from an analytical method, highlighting the conservativeness of the latter.

Details

Journal of Structural Fire Engineering, vol. 5 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 17 February 2015

Jian Jiang, Guo-Qiang Li and Asif Usmani

OpenSees is an open-source object-oriented software framework developed at UC Berekeley. The OpenSees framework has been recently extended to deal with structural behaviour under…

Abstract

OpenSees is an open-source object-oriented software framework developed at UC Berekeley. The OpenSees framework has been recently extended to deal with structural behaviour under fire conditions. This paper summaries the key work done for this extension and focuses on the validation and application of the developed OpenSees to study the behaviour of composite steel-concrete beams under fire conditions. The performance of the developed OpenSees are verified by four mechanical tests and two fire tests on simply supported composite beams. A parametric study is carried out using OpenSees to study the influence of boundary condition as well as composite effect of slab on the behavior of composite beams exposed to fire. The stress and strain along the beam section is output and compared with yield stress limit at elevated temperature to explain these influences in detail. The results show that the stress distribution in the web of the steel beam is more complex due to the support effects.

Details

Journal of Structural Fire Engineering, vol. 6 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Open Access
Article
Publication date: 25 September 2019

Venkatesh Kodur, Puneet Kumar and Muhammad Masood Rafi

The current fire protection measures in buildings do not account for all contemporary fire hazard issues, which has made fire safety a growing concern. Therefore, this paper aims…

88915

Abstract

Purpose

The current fire protection measures in buildings do not account for all contemporary fire hazard issues, which has made fire safety a growing concern. Therefore, this paper aims to present a critical review of current fire protection measures and their applicability to address current challenges relating to fire hazards in buildings.

Design/methodology/approach

To overcome fire hazards in buildings, impact of fire hazards is also reviewed to set the context for fire protection measures. Based on the review, an integrated framework for mitigation of fire hazards is proposed. The proposed framework involves enhancement of fire safety in four key areas: fire protection features in buildings, regulation and enforcement, consumer awareness and technology and resources advancement. Detailed strategies on improving fire safety in buildings in these four key areas are presented, and future research and training needs are identified.

Findings

Current fire protection measures lead to an unquantified level of fire safety in buildings, provide minimal strategies to mitigate fire hazard and do not account for contemporary fire hazard issues. Implementing key measures that include reliable fire protection systems, proper regulation and enforcement of building code provisions, enhancement of public awareness and proper use of technology and resources is key to mitigating fire hazard in buildings. Major research and training required to improve fire safety in buildings include developing cost-effective fire suppression systems and rational fire design approaches, characterizing new materials and developing performance-based codes.

Practical implications

The proposed framework encompasses both prevention and management of fire hazard. To demonstrate the applicability of this framework in improving fire safety in buildings, major limitations of current fire protection measures are identified, and detailed strategies are provided to address these limitations using proposed fire safety framework.

Social implications

Fire represents a severe hazard in both developing and developed countries and poses significant threat to life, structure, property and environment. The proposed framework has social implications as it addresses some of the current challenges relating to fire hazard in buildings and will enhance overall fire safety.

Originality/value

The novelty of proposed framework lies in encompassing both prevention and management of fire hazard. This is unlike current fire safety improvement strategies, which focus only on improving fire protection features in buildings (i.e. managing impact of fire hazard) using performance-based codes. To demonstrate the applicability of this framework in improving fire safety in buildings, major limitations of current fire protection measures are identified and detailed strategies are provided to address these limitations using proposed fire safety framework. Special emphasis is given to cost-effectiveness of proposed strategies, and research and training needs for further enhancing building fire safety are identified.

Details

PSU Research Review, vol. 4 no. 1
Type: Research Article
ISSN: 2399-1747

Keywords

1 – 10 of over 2000