Search results
1 – 10 of 185Ataollah Taghipour Anvari, Mustafa Mahamid, Michael McNallan and Mohammadreza Eslami
The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the…
Abstract
Purpose
The purpose of this paper is to present the effect of damaged fireproofing on structural steel members. This study will show that a minor damage in fireproofing will reduce the fire rating of members significantly. Damaged fireproofing happens in structures due to various reasons, and the question is always how effective is this fireproofing? This paper presents the results of one type of fireproofing and presents a parametric study on the size of damage and its effect on fire resistance of structural steel members.
Design/methodology/approach
The study has been performed using numerical methods, thermal and structural finite element analysis. The analysis method has been verified by experimental results.
Findings
Small fire protection damage or loss leads to significant rise of temperature at the damaged parts and causes severe fire resistance reduction of beams. The higher fire protection damage’s extension at the bottom flange of the steel beams does not have any major influence on the rate of reduction of fire resistance of the beams. Steel beams experience greater fire resistance reduction at higher load levels because of the existing of higher stresses and loads within the steel beam section.
Research limitations/implications
The study has been performed using finite element analysis, and it covers a wide range of practical sizes. However, experimental work will be performed by the researchers when funding is granted.
Practical implications
The study provides researchers and practitioners with an estimate on the effect of damaged fireproofing on fire resistance of structural steel beams.
Social implications
Understanding the effect of the effect of damaged fireproofing helps in estimating the fire resistance of structural steel members, which may protect collapses and disasters.
Originality/value
The research is original; extensive literature review has been performed, and this research is original.
Details
Keywords
Mustafa Mahamid, Ataollah Taghipour Anvari, Ines Torra-Bilal, Tom Brindley and Michael McNallan
The purpose of this paper is to investigate different types of fire on structural steel members with damaged fireproofing. Two types of fire scenarios are considered, ASTM E119…
Abstract
Purpose
The purpose of this paper is to investigate different types of fire on structural steel members with damaged fireproofing. Two types of fire scenarios are considered, ASTM E119 fire and Hydrocarbon fire. In industrial facilities such as oil refineries, certain units maybe subjected to hydrocarbon fire, and its effect might be different than standard fire. The purpose of this study is to compare both types of fire scenarios on steel beams with damaged fireproofing and determine the fire rating of the damaged beams under each fire scenario.
Design/methodology/approach
The study is performed using computational methods, thermal-stress finite element analysis that is validated with experimental results. The results of practical beam sizes and typical applied loads in such structures have been plotted and compared with steel beams with non-damaged fireproofing.
Findings
The results show significant difference in the beam fire resistance between the two fire scenarios and show the fire resistance for beam under each case. The study provides percentage reduction in fire resistance under each case for the most commonly used cases in practice under different load conditions.
Originality/value
Extensive literature search has been performed by the authors, and few studies were found relevant to the topic. The question this study answers comes up regularly in practice. There are no standards to codes that address this issue.
Details
Keywords
Muhannad R. Alasiri and Mustafa Mahamid
Standard fire resistance curves such as ASTM E119 have been used for so long in structural fire practice. The issue with use of these curves that they do not represent real fire…
Abstract
Purpose
Standard fire resistance curves such as ASTM E119 have been used for so long in structural fire practice. The issue with use of these curves that they do not represent real fire scenarios. As a result, the alternatives have been to either conduct experiments or find other tools to represent a real fire scenario. Therefore, the purpose of this paper is to understand the temperature effects resulted from a designed fire on steel beams and whether the standard fire curves represent a designed fire scenario.
Design/methodology/approach
Computational fluid dynamics (CFD) models were developed to simulate a designed fire scenario and to understand the structural responses on the beams under elevated temperatures. Consequently, the results obtained from the CFD models were compared with the results of three-dimensional (3D) non-linear finite element (FE) models developed by other researchers. The developed FE models were executed using a standard fire curve (ASTM E119). A parametric study including two case studies was conducted.
Findings
Results obtained from performing this study showed the importance of considering fire parameters such as fuel type and flame height during the thermal analysis compared to the standard fire curves, and this might lead to a non-conservative design as compared to the designed fire scenario. The studied cases showed that the steel beams experienced more degradation in their fire resistance at higher load levels under designed fires. Additionally, the models used the standard fire curves underestimated the temperatures at the early stages.
Originality/value
This paper shows results obtained by performing a comparison study of models used ASTM E119 curve and a designed fire scenario. The value of this study is to show the variability of using different fire scenarios; thus, more studies are required to see how temperature history curves can be used to represent real fire scenarios.
Details
Keywords
Amit Chandra, Anjan Bhowmick and Ashutosh Bagchi
The study investigates the performance of a three-story unprotected steel moment-resisting frame (SMRF) designed for high seismic demand in the fire-only (FO) and post-earthquake…
Abstract
Purpose
The study investigates the performance of a three-story unprotected steel moment-resisting frame (SMRF) designed for high seismic demand in the fire-only (FO) and post-earthquake uniform and traveling fires (PEF). The primary objective is to investigate the effects of seismic residual deformation on the structure's performance in horizontally traveling fires. The traveling fire methodology, unlike conventional fire models, considers a spatially varying temperature environment.
Design/methodology/approach
Multi-step finite element simulations were carried out on undamaged and damaged frames to provide insight into the effects of the earthquake-initiated fires on the local and global behavior of SMRF. The earthquake simulations were conducted using nonlinear time history analysis, whereas the structure in the fire was investigated by sequential thermal-structural analysis procedure in ABAQUS. The frame was subjected to a suite of seven ground motions. In total, four horizontal traveling fire sizes were considered along with the Eurocode (EC) parametric fire for a comparison. The deformation history, axial force and moment variation in the critical beams and columns of affected compartments in the fire heating and cooling regimes were examined. The global structural performance in terms of inter-story drifts in FO and PEF scenarios was investigated.
Findings
It was observed that the larger traveling fires (25 and 48%) are more detrimental to the case study frame than the uniform EC parametric fire. Besides, no appreciable difference was observed in time and modes of failure of the structure in FO and PEF scenarios within the study's parameters.
Originality/value
The present study considers improved traveling fire methodology as an alternate design fire for the first time for the PEF performance of SMRF. The analysis results add to the much needed database on structures' performance in a wide range of fire scenarios.
Details
Keywords
H.M. Iqbal Mahmud, Autri Mandal, Sudip Nag and Khalid A.M. Moinuddin
The purpose of this study is to investigate the performance of fire protective materials in protecting steel section. A new indexing system is introduced, named as fire endurance…
Abstract
Purpose
The purpose of this study is to investigate the performance of fire protective materials in protecting steel section. A new indexing system is introduced, named as fire endurance index (FEI), which can be used to evaluate the performance of fire protective materials.
Design/methodology/approach
In this study, experiments were carried out using W4 × 13 steel section. Eight samples were prepared; one was a bare steel section without any coating material, and seven were prepared using four types of materials such as vermiculite-gypsum plaster, gypsum plaster, concrete cover and glass wool-concrete cover for fireproofing of the sections. An enclosed electric coiled furnace was used for heating the samples for a certain period. The duration of protection was determined, and the FEI of the materials was calculated. The higher the index value is, the better the performance.
Findings
The results demonstrate that the glass-wool-concrete cover offered the best performance at high temperature among the four types of materials. In the experiment with glass-wool-concrete cover, the furnace temperature reached 750°C, whereas the steel temperature reached only 100°C. The FEI of the coatings were calculated. Among the eight samples, glass wool-concrete cover also achieved the highest index value.
Research limitations/implications
The experimental work was performed using a limited number of specimens. Furthermore, the robustness of the indexing system needs to be evaluated with other materials and a wide range of heating rate and temperature. This study sets the foundation for future work.
Practical implications
The findings of this research may contribute to a better understanding of the performance of the materials used as fire protective coatings. This might be helpful for the researchers and practitioners in their design and implementation of legislation of fire safety codes.
Social implications
Understanding the performance of the fire protective coatings will help in evaluating the fire resistance capabilities of the materials to use for the structural steel members, which may protect collapses and disasters of buildings.
Originality/value
This paper deals with the performance of four types of materials, that can be used as fire protective coatings for structural steel members. Furthermore, the FEI explicitly indicated their performance with numerical values. In this study, the heating of the specimens was performed using a non-standard fire curve based on the concept that naturally occurring incidents of fire do not follow the standard fire curves.
Details
Keywords
Abbas Rezaeian, Mona Mansoori and Amin Khajehdezfuly
Top-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded…
Abstract
Purpose
Top-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded top-seat angle connections.
Design/methodology/approach
A finite element (FE) model, including nonlinear contact interactions, high-temperature properties of steel, and material and geometric nonlinearities was created for accomplishing the fire performance analysis. The FE model was verified by comparing its simulation results with test data. Using the verified model, 24 steel-framed top-seat angle connection assemblies are modeled. Parametric studies were performed employing the verified FE model to study the influence of critical factors on the performance of steel beams and their welded angle joints.
Findings
The results obtained from the parametric studies illustrate that decreasing the gap size and the top angle size and increasing the top angles thickness affect fire behavior of top-seat angle joints and decrease the beam deflection by about 16% at temperatures beyond 570 °C. Also, the fire-resistance rating of the beam with seat angle stiffener increases about 15%, compared to those with and without the web stiffener. The failure of the beam happens when the deflections become more than span/30 at temperatures beyond 576 °C. Results also show that load type, load ratio and axial stiffness levels significantly control the fire performance of the beam with top-seat angle connections in semi-rigid steel frames.
Originality/value
Development of design methodologies for these joints and connected beam in fire conditions is delayed by current building codes due to the lack of adequate understanding of fire behavior of steel beams with welded top-seat angle connections.
Details
Keywords
Abstract
Details
Keywords
Parvathidevi A. and Naga Satish Kumar Ch
This study aims to assess the efficacy of thermal analysis of concrete slabs by including different insulation materials using ANSYS. Regression equations were proposed to predict…
Abstract
Purpose
This study aims to assess the efficacy of thermal analysis of concrete slabs by including different insulation materials using ANSYS. Regression equations were proposed to predict the thermal conductivity using concrete density. As these simulation and regression analyses are essential tools in designing the thermal insulation concretes with various densities, they sequentially reduce the associated time, effort and cost.
Design/methodology/approach
Two grades of concretes were taken for thermal analysis. They were designed by replacing the natural fine aggregates with thermal insulation aggregates: expanded polystyrene, exfoliated vermiculite and light expanded clay. Density, temperature difference, specific heat capacity, thermal conductivity and time were measured by conducting experiments. This data was used to simulate concrete slabs in ANSYS. Regression analysis was performed to obtain the relation between density and thermal conductivity. Finally, the quality of the predicted regression equations was assessed using root mean square error (RMSE), mean absolute error (MAE), integral absolute error (IAE) and normal efficiency (NE).
Findings
ANSYS analysis on concrete slabs accurately estimates the thermal behavior of concrete, with lesser error value ranges between 0.19 and 7.92%. Further, the developed regression equations proved accurate with lower values of RMSE (0.013 to 0.089), MAE (0.009 to 0.088); IAE (0.216 to 5.828%) and higher values of NE (94.16 to 99.97%).
Originality/value
The thermal analysis accurately simulates the experimental transfer of heat across the concrete slab. Obtained regression equations proved helpful while designing the thermal insulation concrete.
Details
Keywords
I argue that the official story about the collapses of the Twin Towers and building 7 of the World Trade Center, according to which the collapses were caused by fire – combined…
Abstract
I argue that the official story about the collapses of the Twin Towers and building 7 of the World Trade Center, according to which the collapses were caused by fire – combined, in the case of the Twin Towers, with the effects of the airplane impacts – cannot be true, for two major reasons. One reason is that fire has never, except allegedly three times on 9/11, caused the total collapse of steel-frame high-rise buildings. All (other) such collapses have been produced by the use of explosives in the procedure known as “controlled demolition.” The other major problem is that the collapses of all three buildings had at least 11 features that would be expected if, and only if, explosives had been used.
I also show the importance of the recently released of 9/11 Oral Histories recorded by the New York Fire Department. With regard to the Twin Towers, many of the firefighters and medical workers said they observed multiple explosions and other phenomena indicative of controlled demolition. With regard to building 7, many testimonies point to widespread foreknowledge that the building was going to collapse, and some of the testimonies contradict the official story that this anticipation of the building's collapse was based on objective indications. These testimonies further strengthen the already virtually conclusive case that all three buildings were brought down by explosives.
I conclude by calling on the New York Times, which got the 9/11 Oral Histories released, now to complete the task of revealing the truth about 9/11.