Search results
1 – 10 of 15Endalkachew Getachew Ushachew, Mukesh Kumar Sharma and Mohammad Mehdi Rashidi
The purpose of this study is to explore the heat transfer enhancement in copper–water nanofluid flowing in a diagonally vented rectangular enclosure with four discrete heaters…
Abstract
Purpose
The purpose of this study is to explore the heat transfer enhancement in copper–water nanofluid flowing in a diagonally vented rectangular enclosure with four discrete heaters mounted centrally on the sidewalls and a square-shaped embedded heated block in the influence of a static magnetic field.
Design/methodology/approach
Four discrete heaters are mounted centrally on each sidewall of the rectangular enclosure that embraces a heated square block. A static transverse magnetic field is acting on the vertical walls. The Navier–Stokes equations of motion and the energy equation are modified by incorporating Lorentz force and basic physical properties of nanofluid. The derived momentum and energy equations are tackled numerically using the successive over-relaxation technique associating with the Gauss–Seidel iteration technique. The effects of physical parameters connected to dynamics of flow and heat convection are explored from streamlines and isotherms graphs and discussed numerically in terms of Nusselt number.
Findings
The effect of the embedded heated square block size and its location in the enclosure, nanoparticles volume fraction and the intensity of the magnetic field on flow and heat transfer are computed. Compared with the case when no heated block is embedded in the enclosure, in free convection at Ra = 106, the average local Nusselt number on the wall-mounted heaters is attenuated by 8.25%, 11.24% and 12.75% when the enclosure embraced a heated square block of side length 10% of H, 20% of H and 30% of H, respectively. An increase in Hartmann number suppresses the heat convection.
Research limitations/implications
The enhancement in the convective heat is greater when the buoyancy effect dominates the viscous effects. Placing the embedded heated block near the inlet vent, the lower temperature zone has reduced while the embedded heated block is at the central location of the enclosure, the high-temperature zone has expanded. The external magnetic field can be used as a non-invasive controlling device.
Practical implications
The numerically simulated results for heat convection of water-based copper nanofluid agreed qualitatively with the existing experimental results.
Social implications
The models could be used in designing a target-oriented heat exchanger.
Originality/value
The paper includes a comparative study for three locations of the embedded heated square. The optimal results for the centrally located heated block are also performed for three different sizes of the embedded block. The numerically simulated results are compared with the published numerical and experimental studies.
Details
Keywords
Fatih Selimefendigil and Ali J. Chamkha
This study aims to numerically examine mixed convection of CuO-water nanofluid in a three-dimensional (3D) vented cavity with inlet and outlet ports under the influence of an…
Abstract
Purpose
This study aims to numerically examine mixed convection of CuO-water nanofluid in a three-dimensional (3D) vented cavity with inlet and outlet ports under the influence of an inner rotating circular cylinder, homogeneous magnetic field and surface corrugation effects. In practical applications, it is possible to encounter some of the considered configurations in a vented cavity such as magnetic field, rotating cylinder and it is also possible to specially add some of the active and passive control means to control the convection inside the cavity such as adding nanoparticles, corrugating the surfaces. The complicated physics with nanofluid under the effects of magnetic field and inclusion of complex 3D geometry make it possible to use the results of this numerical investigation for the design, control and optimization of many thermal engineering systems as mentioned above.
Design/methodology/approach
The bottom surface is corrugated with a rectangular wave shape, and the rotating cylinder surface and cavity bottom surface were kept at constant hot temperatures while the cold fluid enters the inlet port with uniform velocity. The complicated interaction between the forced convection and buoyancy-driven convection coupled with corrugated and rotating surfaces in 3D configuration with magnetic field, which covers a wide range of thermal engineering applications, are numerically simulated with finite element method. Effects of various pertinent parameters such as Richardson number (between 0.01 and 100), Hartmann number (between 0 and 1,000), angular rotational speed of the cylinder (between −30 and 30), solid nanoparticle volume fraction (between 0 and 0.04), corrugation height (between 0 and 0.18H) and number (between 1 and 20) on the convective heat transfer performance are numerically analyzed.
Findings
It was observed that the magnetic field suppresses the recirculation zone obtained in the lower part of the inlet port and enhances the average heat transfer rate, which is 10.77 per cent for water and 6.86 per cent for nanofluid at the highest strength. Due to the thermal and electrical conductivity enhancement of nanofluid, there is 5 per cent discrepancy in the Nusselt number augmentation with the nanoadditive inclusion in the absence and presence of magnetic field. The average heat transfer rate of the corrugated surface enhances by about 9.5 per cent for counter-clockwise rotation at angular rotational speed of 30 rad/s as compared to motionless cylinder case. Convective heat transfer characteristics are influenced by introducing the corrugation waves. As compared to number of waves, the height of the corrugation has a slight effect on the heat transfer variation. When the number of rectangular waves increases from N = 1 to N = 20, approximately 59 per cent of the average heat transfer reduction is achieved.
Originality/value
In this study, mixed convection of CuO-water nanofluid in a 3D vented cavity with inlet and outlet ports is numerically examined under the influence of an inner rotating circular cylinder, homogeneous magnetic field and surface corrugation effects. To the best of authors knowledge such a study has never been performed. In practical applications, it is possible to encounter some of the considered configurations in a vented cavity such as magnetic field, rotating cylinder and it is also possible to specially add some of the active and passive control means to control the convection inside the cavity such as adding nanoparticles, corrugating the surfaces. The complicated physics with nanofluid under the effects of magnetic field and inclusion of complex 3D geometry make it possible to use the results of this numerical investigation for the design, control and optimization of many thermal engineering systems as mentioned above.
Details
Keywords
S.V.S.S.N.V.G. Krishna Murthy and B.V. Rathish Kumar
It is well known that the mixed convection process is the combined effect of the presence of both the forced and the free convection processes. In several applications such as…
Abstract
Purpose
It is well known that the mixed convection process is the combined effect of the presence of both the forced and the free convection processes. In several applications such as environmental chambers, IC engines, etc. the forced convection is brought in by multiple suction/injection (S/I) effect. Study of mixed convection in a vertical square fluid saturated porous cavity with multiple S/I effect greatly contributes to such an understanding. So far, not much research work has reported in this direction. Hence, the purpose of this paper is to investigate such a mixed convection process in a fluid saturated vertical porous square cavity.
Design/methodology/approach
In this study, the authors numerically solved the couple partial differential equations governing the mixed convection process in a fluid saturated vertical square porous cavity by finite element method. The study is parametric in nature wherein the authors cover a large range of values for different parameters arising the mathematical model governing the problem under consideration.
Findings
The influence of multiple S/I effects on mixed convection is analyzed for a wide range of controlling parameters such as S/I flow velocities (a), S/I window size (D/H) and Rayleigh number (Ra). Both the flow and temperature fields are highly sensitive to magnitude of S/I velocity, S/I window slit size and “Ra”. While heat fluxes along the isothermal left vertical wall decrease with increasing S/I velocities they are formed to increase with increasing “(D/H)” and “Ra”. Nusselt numbers increase with increasing “Ra” and increasing size of S/I window slit size. Multi‐cellular circulation pattern and thermal boundary layers are seen to manifest in flow and temperature fields, respectively.
Research limitations/implications
The study is based on 2D model, but the model is generic in nature; also it is fully numerical in nature. Due to lack of apt literature no experimental support is provided. The mathematical model used in the study is based on certain assumptions such as isotropic porous medium, fluid is viscous in nature and follows Newtonian laws and the porous structure is saturated with fluid, etc. Regarding future work, 3D modelling and simulation is in progress and attempts are also being made to collaborate with experimental groups on the problem under investigation.
Practical implications
The results from the work are relevant to the context of heat and fluid flow studies in IC engines, influence of mixed convection process on bacterial growth process in environmental chambers and cooling of electronic devices, etc.
Originality/value
The paper describes a mathematical model, especially the boundary treatment, for describing the influence of multiple S/I effects on mixed convection flow in a vertical square enclosure filled with a Darcian fluid saturated homogeneous porous medium. To understand the physics behind the mixed convection process in the proposed configuration, extensive numerical simulations have been carried out for the first time for different values of the important governing parameters arising from the model.
Details
Keywords
Lioua Kolsi, Fatih Selimefendigil and Mohamed Omri
The purpose of this study is to explore the phase change (PC) dynamics in a T-shaped ventilated cavity having multiple inlet and outlet ports during nanofluid convection with…
Abstract
Purpose
The purpose of this study is to explore the phase change (PC) dynamics in a T-shaped ventilated cavity having multiple inlet and outlet ports during nanofluid convection with phase change material (PCM) packed bed-installed system.
Design/Methodology/Approach
Finite element method was used to analyze the PC dynamics and phase completion time for encapsulated PCM within a vented cavity during the convection of nanoparticle loaded fluid. The study is performed for different Reynolds number of flow streams (Re1 and Re2 between 300 and 900), temperature difference (ΔT1 and ΔT2 between −5 and 10), aspect ratio of the cavity (between 0.5 and 1.5) and nanoparticle loading (between 0.02% and 0.1%).
Findings
It is observed that phase transition can be controlled by assigning different velocities and temperatures at the inlet ports of the T-shaped cavity. The PC becomes fast especially when the Re number and temperature of fluid in the port vary closer to the wall (second port). When the configurations with the lowest and highest Re number of the second port are considered up to 54.7% in reduction of complete phase transition time is obtained, while this amount is 78% when considering the lowest and highest inlet temperatures. The geometric factor which is the aspect ratio has also affected the flow field and PC dynamics. Up to 78% reduction in the phase transition time is obtained at the highest aspect ratio. Further improvements in the performance are achieved by using nanoparticles in the base fluid. The amounts in the phase transition time reduction are 8% and 10.5% at aspect ratio of 0.5 and 1.5 at the highest nanoparticle concentration.
Originality/Value
The thermofluid system and offered control mechanism for PC dynamics control can be considered for the design, optimization, further modeling and performance improvements of applications with PCM installed systems.
Details
Keywords
Md Motiur Rahaman, Nirmalendu Biswas, Apurba Kumar Santra and Nirmal K. Manna
This study aims to delve into the coupled mixed convective heat transport process within a grooved channel cavity using CuO-water nanofluid and an inclined magnetic field. The…
Abstract
Purpose
This study aims to delve into the coupled mixed convective heat transport process within a grooved channel cavity using CuO-water nanofluid and an inclined magnetic field. The cavity undergoes isothermal heating from the bottom, with variations in the positions of heated walls across the grooved channel. The aim is to assess the impact of heater positions on thermal performance and identify the most effective configuration.
Design/methodology/approach
Numerical solutions to the evolved transport equations are obtained using a finite volume method-based indigenous solver. The dimensionless parameters of Reynolds number (1 ≤ Re ≤ 500), Richardson number (0.1 ≤ Ri ≤ 100), Hartmann number (0 ≤ Ha ≤ 70) and magnetic field inclination angle (0° ≤ γ ≤ 180°) are considered. The solved variables generate both local and global variables after discretization using the semi-implicit method for pressure linked equations algorithm on nonuniform grids.
Findings
The study reveals that optimal heat transfer occurs when the heater is positioned at the right corner of the grooved cavity. Heat transfer augmentation ranges from 0.5% to 168.53% for Re = 50 to 300 compared to the bottom-heated case. The magnetic field’s orientation significantly influences the average heat transfer, initially rising and then declining with increasing inclination angle. Overall, this analysis underscores the effectiveness of heater positions in achieving superior thermal performance in a grooved channel cavity.
Research limitations/implications
This concept can be extended to explore enhanced thermal performance under various thermal boundary conditions, considering wall curvature effects, different geometry orientations and the presence of porous structures, either numerically or experimentally.
Practical implications
The findings are applicable across diverse fields, including biomedical systems, heat exchanging devices, electronic cooling systems, food processing, drying processes, crystallization, mixing processes and beyond.
Originality/value
This work provides a novel exploration of CuO-water nanofluid flow in mixed convection within a grooved channel cavity under the influence of an inclined magnetic field. The influence of different heater positions on thermomagnetic convection in such a cavity has not been extensively investigated before, contributing to the originality and value of this research.
Details
Keywords
Stubs materials in new fight against corrosion offshore. In an effort to overcome a problem of corrosion, Chevron Petroleum (UK) Ltd is to install LP oil cooler vessels made from…
Abstract
Stubs materials in new fight against corrosion offshore. In an effort to overcome a problem of corrosion, Chevron Petroleum (UK) Ltd is to install LP oil cooler vessels made from cupro‐nickel clad steel on its Ninian Southern platform. Their fabrication is being carried out at the Cheltenham works of Graham Manufacturing Ltd and will involve the use of some 360kg of welding consumables from the Stubs Welding ‘special’ range.
THE FIRST development flight aircraft Concorde 001 and 002 both have “heavyweight” fuel systems fitted to control the Olympus 593 engines.
Andrea Cremasco, Wei Wu, Andreas Blaszczyk and Bogdan Cranganu-Cretu
The application of dry-type transformers is growing in the market because the technology is non-flammable, safer and environmentally friendly. However, the unit dimensions are…
Abstract
Purpose
The application of dry-type transformers is growing in the market because the technology is non-flammable, safer and environmentally friendly. However, the unit dimensions are normally larger and material costs become higher, as no oil is present for dielectric insulation or cooling. At designing stage, a transformer thermal model used for predicting temperature rise is fundamental and the modelling of cooling system is particularly important. This paper aims to describe a thermal model used to compute dry transformers with different cooling system configurations.
Design/methodology/approach
The paper introduces a fast-calculating thermal and pressure network model for dry-transformer cooling systems, preliminarily verified by analytical methods and advanced CFD simulations, and finally validated with experimental results.
Findings
This paper provides an overview of the network model of dry-transformer cooling system, describing its topology and its main variants including natural or forced ventilation, with or without cooling duct in the core, enclosure with roof and floor ventilation openings and air barriers. Finally, it presents a formulation for the new heat exchanger element.
Originality/value
The network approach presented in this paper allows to model efficiently the cooling system of dry-type transformers. This model is based on physical principles rather than empirical assessments that are valid only for specific transformer technologies. In comparison with CFD simulation approach, the network model runs much faster and the accuracies still fall in acceptable range; therefore, one is able to utilize this method in optimization procedures included in transformer design systems.
Details
Keywords
Zohir Younsi, Lounes Koufi and Hassane Naji
A comprehensive investigation on the outlet air position effects on the thermal comfort and air quality has been achieved. In addition, airflow and temperature distributions in…
Abstract
Purpose
A comprehensive investigation on the outlet air position effects on the thermal comfort and air quality has been achieved. In addition, airflow and temperature distributions in ventilated cavities filled with an air-CO2 mixture with mixed convection are predicted. The airflow enters from the cavity through an opening in the lower side of the left vertical wall and exits through the opening in one wall of the cavity. This paper aims to investigate the outlet location effect, four different placement configurations of output ports are considered. Three of them are placed on the upper side and the fourth on top of the opposite side of the inlet opening. A uniform heat and CO2 contaminant source are applied on the left vertical wall, while the remaining walls are impermeable and adiabatic to heat and solute. The cooling efficiency inside the enclosure and the average fluid temperature are computed for different Reynolds and Rayleigh numbers to find the most suitable fluid outlet position that ensures indoor comfortable conditions while effectively removing heat and the contaminant. This is demonstrated by three relevant indices, namely, the effectiveness for heat removal, the contaminant removal and the index of indoor air quality.
Design/methodology/approach
The simulations were performed via the finite-volume scSTREAM CFD solver V11. Three different values of CO2 amount are considered, namely, 103, 2 × 103 and 3 × 103 ppm, the Reynolds number being in the range 100 ≤ Re ≤ 800.
Findings
Based on the findings obtained, it is the configuration whose air outlet is placed near the heat source and the contaminant, which provides a better air distribution and a ventilation efficiency compared to the others ventilation strategies.
Originality/value
The studies on heat and mass transfers by natural and forced convection in ventilated cavities remain a fruitful research topic. Thereby, such a study deals with different ventilation strategies through cavities containing an air-CO2 mixture subjected to a mixed regime. In particular, the air inlet velocity and contaminant sources’ effects on thermal comfort and air quality have been investigated.
Details
Keywords
When the British Caledonian Airways' new wide‐bodied DC‐10–30 touched down at London Gatwick airport there was a giant mobile maintenance tail dock ready to receive it.