Search results

1 – 10 of over 7000
Article
Publication date: 8 June 2021

Shufeng Li, Zhang Jiaolei, Di Zhao and Le Deng

This study aims to further study the fire resistance of prefabricated concrete beam-column joints with end-plate connection. This paper aims to analyze the fire resistance of this…

Abstract

Purpose

This study aims to further study the fire resistance of prefabricated concrete beam-column joints with end-plate connection. This paper aims to analyze the fire resistance of this joint in prefabricated reinforced concrete frame structure (PRCS).

Design/methodology/approach

First, the accuracy of the model is verified by using the test data. Based on this, a refined finite element model of PRCS structure with two stories and two spans is established. The influence of four working conditions with different fire floors (positions) and different axial compression ratios on the deformation, failure and fire resistance of PRCS structure are analyzed.

Findings

The results show that under the four working conditions, the fire resistance of the PRCS structure under Condition 1 and Condition 2 is smaller. It shows that the beam deformation develops slowly in PRCS structure under four kinds of fire positions, and the large displacement emerges 60 min later, which is poles apart from that of prefabricated beam column members. With the increase of the fire time, the material is damaged and deteriorated, which leads to the eccentricity of the axial load, so that the column top appears large lateral displacement. Under the Conditions 1 and 3, the lateral displacement of the column gradually decreases as the axial compression ratio rises.

Originality/value

It is found that there is a distinct lack of researching on the fire resistance of prefabricated joints, and the existed research studies are limited to the fire resistance of members. Thus, it is necessary to strengthen the first floor and side column design of prefabricated frame structure.

Details

Journal of Structural Fire Engineering, vol. 12 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 14 July 2020

Shufeng Li, Le Deng and Zhao Di

The purpose of this study is to put forward a high-strength bolt end-plate connection of prefabricated concrete beam-column joint and carry out the pseudo-static test.

Abstract

Purpose

The purpose of this study is to put forward a high-strength bolt end-plate connection of prefabricated concrete beam-column joint and carry out the pseudo-static test.

Design/methodology/approach

ABAQUS finite element software is used to study the fire resistance performance of high-strength bolt end-plate prefabricated joint. This mainly considers the influence of axial compression ratio, screw preload, end-plate thickness and steel hoop thickness.

Findings

The results show that the thickness of end-plate and steel hoop has a certain effect on the fire resistance. The change of screw preload has little effect on the fire resistance limit. Compared with the cast-in-place concrete beam-column joint, the deformation trend of column-beam end of the fabricated joint is basically the same as that of cast-in-place joint.

Originality/value

To study the mechanical performance of this kind of joint more comprehensively, the finite element software is used to study the prefabricated concrete beam-column joint with end-plates, and the effects of axial compression ratio, screw preload, end-plate thickness and steel hoop thickness on the fire resistance of joints are mainly considered.

Details

Journal of Structural Fire Engineering, vol. 11 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 28 May 2020

András Jakab, Viktor Hlavicka, Ágoston Restás and Eva Lubloy

During the building designing, it is very important to deal with the fire resistance of the structures. The designed materials for escape routes should be selected to ensure the…

Abstract

Purpose

During the building designing, it is very important to deal with the fire resistance of the structures. The designed materials for escape routes should be selected to ensure the usability of the structures until the time of escape. Planning affects the glass structures similarly, so these can also be partition walls and load bearing structures, although the latter is less applied on escape routes. The heat protection of the glasses can be improved with heat-protective foils, while fire protection is provided by gel intumescent material.

Design/methodology/approach

To research the topic of fire resistance, laboratory experiments were carried out on small-scaled glass elements with thermal protection foil at Budapest University of Technology and Economics at the Department of Construction Materials and Technologies.

Findings

Fire protection of small model specimens was tested with blowtorch fire and furnace heat load. During the experiments, six foils were tested. Single pane glass, double layered and triple glazed specimens were tested with blowtorch fire.

Originality/value

Fire protection of small model specimens was tested with blowtorch fire and furnace heat load. During the experiments, six foils were tested. Single pane glass, double layered and triple glazed specimens were tested with blowtorch fire. In case of heat-protected glazing, the foils on the “protected” side of the single pane glass do not have a fire protection effect based on blowtorch fire test. For double glassed specimens, the P35 foil has a perceptible effect, even for the requirements of the flame breakthrough (E, integrity), when the foil is placed on the inner side (position 3) of the second glass layer. The stratification of each triple glazed specimens was effective against blowtorch fire load (3 M, S4&P35), so (EI, integrity and isolation) it can meet the requirements of flame breakthrough and thermal insulation.

Details

Journal of Structural Fire Engineering, vol. 11 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 December 2023

T.M. Jeyashree and P.R. Kannan Rajkumar

This study focused on identifying critical factors governing the fire response of prestressed hollow-core slabs. The hollow-core slabs used as flooring units can be subjected to…

Abstract

Purpose

This study focused on identifying critical factors governing the fire response of prestressed hollow-core slabs. The hollow-core slabs used as flooring units can be subjected to elevated temperatures during a fire. The fire response of prestressed hollow-core slabs is required to develop slabs with greater fire endurance. The present study aims to determine the extent to which the hollow-core slab can sustain load during a fire without undergoing progressive collapse under extreme fire and heating scenarios.

Design/methodology/approach

A finite element model was generated to predict the fire response of prestressed hollow core slabs under elevated temperatures. The accuracy of the model was predicted by examining thermal and structural responses through coupled temperature displacement analysis. A sensitivity analysis was performed to study the effects of concrete properties on prediction of system response. A parametric study was conducted by varying the thickness of the slab, fire and heating scenarios.

Findings

Thermal conductivity and specific heat of concrete were determined as sensitive parameters. The thickness of the slab was identified as a critical factor at a higher load level. Asymmetric heating of the slab resulted in higher fire resistance compared with symmetric heating.

Originality/value

This is the first study focused on studying the effect of modeling uncertainties on the system response by sensitivity analysis under elevated temperatures. The developed model with a parametric study helps in identifying critical factors for design purposes.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 21 July 2023

Jinhua Sun

Steel-reinforced concrete-filled steel tubular (SRCFST) columns have been increasingly popular in engineering practice for the columns' excellent seismic and fire performance…

Abstract

Purpose

Steel-reinforced concrete-filled steel tubular (SRCFST) columns have been increasingly popular in engineering practice for the columns' excellent seismic and fire performance. Significant design progress guidance has been made through continuous numerical and experimental research in recent years. This paper tested and analysed the residual loading capacity of SRCFST columns under axial loading after experiencing non-uniform ISO-834 standard fire.

Design/methodology/approach

The experimental research covered the main parameter of heating conditions, 1-side and 2-side fire, through two specimens. Two specimens were heated and loaded simultaneously in the furnace for 240 min. After cooling, the columns were moved to the hydraulic loading system and loaded to failure to determine the columns' residual capacity.

Findings

The experimental results indicated that the non-uniform heating area plays an essential role in the overall performance of SRCFST columns, the increasing heating area of columns results in lower residual loading capacity and stiffness. The SRCFST columns still had a high loading capacity after heating and loading in the fire.

Originality/value

The comparison of experimental data against design results showed that the design method generated a 16% safety margin for S2H4 and a 39% safety margin for S1H4.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 29 March 2024

Aminuddin Suhaimi, Izni Syahrizal Ibrahim and Mariyana Aida Ab Kadir

This review paper seeks to enhance knowledge of how pre-loading affects reinforced concrete (RC) beams under fire. It investigates key factors like deflection and load capacity to…

Abstract

Purpose

This review paper seeks to enhance knowledge of how pre-loading affects reinforced concrete (RC) beams under fire. It investigates key factors like deflection and load capacity to understand pre-loading's role in replicating RC beams' actual responses to fire, aiming to improve fire testing protocols and structural fire engineering design.

Design/methodology/approach

This review systematically aggregates data from existing literature on the fire response of RC beams, comparing scenarios with (WP) and without pre-loading (WOP). Through statistical tools like the two-tailed t-test and Mann–Whitney U-test, it assesses deflection extremes. The study further examines structural responses, including flexural and shear behavior, ultimate load capacity, post-yield behavior, stiffness degradation and failure modes. The approach concludes with a statistical forecast of ideal pre-load levels to elevate experimental precision and enhance fire safety standards.

Findings

The review concludes that pre-loading profoundly affects the fire response of RC beams, suggesting a 35%–65% structural capacity range for realistic simulations. The review also recommended the initial crack load as an alternative metric for determining the pre-loading impact. Crucially, it highlights that pre-loading not only influences the fire response but also significantly alters the overall structural behavior of the RC beams.

Originality/value

The review advances structural fire engineering with an in-depth analysis of pre-loading's impact on RC beams during fire exposure, establishing a validated pre-load range through thorough statistical analysis and examination of previous research. It refines experimental methodologies and structural design accuracy, ultimately bolstering fire safety protocols.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 21 June 2021

Eva Lubloy, Lajos Gábor Takács, David Istvan Enczel and Zsolt Cimer

The fire safety of structures is an existing and important design aspect, which is assured by strict regulations. As a means to adhere to the strict requirements, fire protection…

Abstract

Purpose

The fire safety of structures is an existing and important design aspect, which is assured by strict regulations. As a means to adhere to the strict requirements, fire protection has become a core problem. It is particularly difficult to comply with these regulations in the case of timber, which is a combustible material. These problems could be solved by enveloping the wood in fire retardant materials. MSZ EN 1995-1-2 currently does not take into consideration the fire-retardant materials charring rate under fire exposure.

Design/methodology/approach

However, currently these fire retardants are proving to be reliable and depending on their application can achieve better reaction-to-fire classifications. During the research, the authors used five different fire-retardant materials on three different types of wood and tested their behaviours in a laboratory. When selecting them, it was important to choose the species that are most commonly used in the building industry but which have significantly different densities. Our choice fell upon spruce (360 kg/m3), Scots pine (540 kg/m3) and oak (650 kg/m3). During the tests, we examined the weight reduction and the process of burning on the specimens treated with the fire retardant material. In addition, the authors also performed tests by derivatography on both untreated and treated specimen.

Findings

The question is whether the effects of the fire retardants should be taken into consideration when calculating the extent of the burn. The Eurocode (MSZ EN 1995-1-2) does not provide any opinions. On the market, there are manufacturers who are already discussing the possibilities of reducing the burn rate during the qualification of paints. In this paper, based on the results we received, we discuss the beneficial effects of the fire retardants which can be taken into account while measuring cross-sections.

Originality/value

By using fire retardants, a high proportion of cross-sectional area gain is only possible in case of small cross-sections; therefore, it is advisable to use them here as well. This can be effective for example in many smaller cross-sections, when there is a little space and therefore requires a small cross-section. Thus, if a larger cross-section without protection is not possible, it can be replaced by a smaller cross section, treated with a fire retardant.

Details

Journal of Structural Fire Engineering, vol. 12 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 29 March 2024

Sihao Li, Jiali Wang and Zhao Xu

The compliance checking of Building Information Modeling (BIM) models is crucial throughout the lifecycle of construction. The increasing amount and complexity of information…

Abstract

Purpose

The compliance checking of Building Information Modeling (BIM) models is crucial throughout the lifecycle of construction. The increasing amount and complexity of information carried by BIM models have made compliance checking more challenging, and manual methods are prone to errors. Therefore, this study aims to propose an integrative conceptual framework for automated compliance checking of BIM models, allowing for the identification of errors within BIM models.

Design/methodology/approach

This study first analyzed the typical building standards in the field of architecture and fire protection, and then the ontology of these elements is developed. Based on this, a building standard corpus is built, and deep learning models are trained to automatically label the building standard texts. The Neo4j is utilized for knowledge graph construction and storage, and a data extraction method based on the Dynamo is designed to obtain checking data files. After that, a matching algorithm is devised to express the logical rules of knowledge graph triples, resulting in automated compliance checking for BIM models.

Findings

Case validation results showed that this theoretical framework can achieve the automatic construction of domain knowledge graphs and automatic checking of BIM model compliance. Compared with traditional methods, this method has a higher degree of automation and portability.

Originality/value

This study introduces knowledge graphs and natural language processing technology into the field of BIM model checking and completes the automated process of constructing domain knowledge graphs and checking BIM model data. The validation of its functionality and usability through two case studies on a self-developed BIM checking platform.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 4 March 2020

Eva Lubloy

The aim of the research was to investigate the effect of concrete strength on the fire resistance of structures. At first, it may seem contradictory that higher concrete strengths…

Abstract

Purpose

The aim of the research was to investigate the effect of concrete strength on the fire resistance of structures. At first, it may seem contradictory that higher concrete strengths can decrease the fire resistance of building structures. However, if the strength of the concrete exceeds a maximum value, the risk of spalling (the detachment of the concrete surface) significantly.

Design/methodology/approach

Prefabricated structural elements are often produced with higher strength. The higher concrete strengths generally do not cause a reduction in the load bearing capacity, but it can have serious consequences in case of structural fire design. Results of two prefabricated elements, namely, one slab (TT shaped panel) and one single layer wall panel, were examined. Results of the specimen with the originally designed composition and a specimen with modified concrete composition were examined, were polymer fibres were added to prevent spalling.

Findings

As a result of the experiments, more strict regulations in the standards the author is suggested including more strict regulations in the standards. It has been proved that to ensure the fire safety of the reinforced concrete structures, it is required after polymer fibres even in lower concrete strength class than prescribed by the standard. In addition, during the classification and evaluation of structures, it is advisable to introduce an upper limit of allowed concrete strength for fire safety reasons.

Originality/value

As a result of the experiments, the author suggests including more strict regulations in the standards. It has been proved that to ensure the fire safety of the reinforced concrete structures, it is necessary to require the addition of polymer fibres even in lower concrete strength class than prescribed by the standard. In addition, during the classification and evaluation of structures, it is advisable to introduce an upper limit of allowed concrete strength for fire safety reasons.

Details

Journal of Structural Fire Engineering, vol. 11 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 27 May 2020

Ranjit Kumar Chaudhary, Tathagata Roy and Vasant Matsagar

Despite recognizing the significance of risk-based frameworks in fire safety engineering, the usual approach in structural fire design is largely member/component level, wherein…

Abstract

Purpose

Despite recognizing the significance of risk-based frameworks in fire safety engineering, the usual approach in structural fire design is largely member/component level, wherein effect of uncertainties influencing the fire resistance of structures are not explicitly considered. In this context, a probabilistic framework is presented to investigate the vulnerability of a reinforced concrete (RC) members and structure under fire loading scenario.

Design/methodology/approach

The RC structures exposed to fire are modeled in a finite element (FE) platform incorporating material and geometric nonlinearity, in which the transient thermo-mechanical analysis is carried out by suitably incorporating the temperature variation of thermal and mechanical properties of both concrete and steel rebar. The stochasticity in the system is considered in structural resistance, thermal and fire model parameters, and the subsequent fragility curves are developed considering threshold limit state of deflection.

Findings

The fire resistance of RC structure is reported to be significantly lower in comparison to the RC members, thereby illustrating the current prescriptive design approaches based on studies of structural member behavior to be crucial from a safety and reliability point of view.

Practical implications

The framework developed for the vulnerability assessment of RC structures under fire hazard through FE analysis can be effectively used to estimate the structural fire resistance for other similar structure to enhance safety and reliability of structures under such extreme threats.

Originality/value

The paper proposes a novel methodology for vulnerability assessment of three-dimensional RC structures under fire hazard through FE analysis and provides comparison of the structural fragility with fragility developed for structural members. Moreover, the research emphasizes to assume 3D behavior of the structure rather than the approximate 2D behavior.

Details

Journal of Structural Fire Engineering, vol. 11 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

1 – 10 of over 7000