Search results

1 – 10 of 156
Article
Publication date: 13 February 2019

Abdurra’uf Mukhtar Gora, Jayaprakash Jaganathan, Mohammed Parvez Anwar and Hau Y. Leung

The purpose of this paper is to present the results of experimental and theoretical studies on the flexural capacity of reinforced concrete (RC) beams strengthened using…

Abstract

Purpose

The purpose of this paper is to present the results of experimental and theoretical studies on the flexural capacity of reinforced concrete (RC) beams strengthened using externally bonded bi-directional glass fibre reinforced polymer (GFRP) composites and different end anchorage systems.

Design/methodology/approach

A series of nine RC beams with a length of 1,600 mm and a cross-section of 200 mm depth and 100 mm width were prepared and externally strengthened in flexure with bi-directional GFRP composites. These strengthened beams were anchored with three different end anchorage systems namely closed GFRP wraps, GFRP U-wraps and mechanical anchors. All these beams were tested with four-point bending system up to failure. The experimental results are compared with the theoretical results obtained using the relevant design guidelines.

Findings

The experimental results demonstrate a significant increase in the flexural performance of the GFRP strengthened beams with regard to the ultimate load carrying capacity and stiffness. The results also show that GFRP strengthened beams without end anchorages experienced intermediate concrete debonding failure at the GFRP plate end, whereas all the GFRP strengthened beams with different end anchorage systems failed in rupture of GFRP with concrete crushing. The theoretical results revealed no significant difference among the relevant design guidelines with regard to the predicted ultimate moment capacities of the bi-directional GFRP strengthened RC beams. However, the results show that ACI Committee 440 Report (2008) design recommendation provides reasonably acceptable predictions for the ultimate moment capacities of the tested beams strengthened externally with bi-directional GFRP reinforcement followed by FIB Bulletin 14 (2001) and eventually by JSCE (1997).

Originality/value

The research work presented in this manuscript is authentic and could contribute to the understanding of the overall behaviour of RC beams strengthened with FRP and different end anchorage systems under flexural loading.

Details

International Journal of Structural Integrity, vol. 10 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 22 August 2022

Long Liu and Songqiang Wan

To make full use of the tensile strength of near surface mounting (NSM) pasted carbon fiber reinforced plastics (CFRP) strips and further increase the flexural bearing capacity and

89

Abstract

Purpose

To make full use of the tensile strength of near surface mounting (NSM) pasted carbon fiber reinforced plastics (CFRP) strips and further increase the flexural bearing capacity and flexibility of reinforced concrete (RC) beams, a new composite reinforcement method using ultra-high performance concrete (UHPC) layer in the compression zone of RC beams is submitted based on embedding CFRP strips in the tension zone of RC beams. This paper aims to discuss the aforementioned points.

Design/methodology/approach

The experimental beam was simulated by ABAQUS, and compared with the experimental results, the validity of the finite element model was verified. On this basis, the reinforced RC beam is used as the control beam, and parameters such as the CFRP strip number, UHPC layer thickness, steel bar ratio and concrete strength are studied through the verified model. In addition, the numerical calculation results of yield strength, ultimate strength, failure deflection and flexibility are also given.

Findings

The flexural bearing capacity of RC beams supported by the new method is 132.3% higher than that of unreinforced beams, and 7.8% higher than that of RC beams supported only with CFRP strips. The deflection flexibility coefficient of the new reinforced RC beam is 8.06, which is higher than that of the unreinforced beam and the reinforced concrete beam with only CFRP strips embedded in the tension zone.

Originality/value

In this paper, a new reinforcement method is submitted, and the effects of various parameters on the ultimate bearing capacity and flexibility of reinforced RC beams are analyzed by the finite element numerical simulation. Finally, the effectiveness of the new method is verified by the analytical formula.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 23 March 2022

Long Liu, Xingpeng Ma, Li Yan and Yongmei Wang

Embedding carbon fiber reinforced plastics (CFRP) bars in the tension zone of reinforced concrete (RC) beams is a widely used reinforcement method, which has the advantages of…

Abstract

Purpose

Embedding carbon fiber reinforced plastics (CFRP) bars in the tension zone of reinforced concrete (RC) beams is a widely used reinforcement method, which has the advantages of strong anti-peel ability and high utilization of tensile materials. To further improve the flexural bearing capacity of RC beams, a new composite reinforcement method using the UHPC layer in the compressive zone of RC beams is proposed based on embedding CFRP bars in the tension zone of RC beams.

Design/methodology/approach

The finite element model of an RC experimental beam with CFRP bars embedded in the tension zone was carried out by ABAQUS. Besides, the reliability of the finite element model results was verified by comparing with the experimental results. On this basis, the flexural reinforcement effect of CFRP bars and UHPC layers on RC beams was analyzed.

Findings

Calculation results show the flexural bearing capacity of the beam strengthened by the new method is 15.9%, which is higher than that of the unreinforced beam, and 10.4% higher than that of the beam strengthened only with CFRP bars. The beam ductility ratio of the new method is 8.25%, which is slightly higher than that of the unreinforced beam and equal to that of the beam reinforced only with CFRP bars embedded in the tension zone. The effectiveness of the new method is further verified by using the analytical calculation method.

Originality/value

A new flexural reinforcement method for reinforced concrete beams is proposed, and the effectiveness of the method was verified by experiments and finite element model. The flexural bearing capacity and ductility of the new method were analyzed based on the load-deflection curve. Finally, the possibility of the new method was verified by analytical analysis.

Details

Multidiscipline Modeling in Materials and Structures, vol. 18 no. 2
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 9 April 2024

Long Liu, Lifeng Wang and Ziwang Xiao

The combination of an Engineered Cementitious Composite (ECC) layer and steel plate to reinforce RC beams (ESRB) is a new strengthening method. The ESRB was proposed based on the…

Abstract

Purpose

The combination of an Engineered Cementitious Composite (ECC) layer and steel plate to reinforce RC beams (ESRB) is a new strengthening method. The ESRB was proposed based on the steel plate at the bottom of RC beams, aiming to solve the problem of over-reinforced RC beams and improve the bearing capacity of RC beams without affecting their ductility.

Design/methodology/approach

In this paper, the finite element model of ESRB was established by ABAQUS. The results were compared with the experimental results of ESRB in previous studies and the reliability of the finite element model was verified. On this basis, parameters such as the width of the steel plate, thickness of the ECC layer, damage degree of the original beam and cross-sectional area of longitudinal tensile rebar were analyzed by the verified finite element model. Based on the load–deflection curve of ESRB, ESRB was discussed in terms of ultimate bearing capacity and ductility.

Findings

The results demonstrate that when the width of the steel plate increases, the ultimate load of ESRB increases to 133.22 kN by 11.58% as well as the ductility index increases to 2.39. With the increase of the damage degree of the original beam, the ultimate load of ESRB decreases by 23.7%–91.09 kN and the ductility index decreases to 1.90. With the enhancement of the cross-sectional area of longitudinal tensile rebar, the ultimate bearing capacity of ESRB increases to 126.75 kN by 6.2% and the ductility index elevates to 2.30. Finally, a calculation model for predicting the flexural capacity of ESRB is proposed. The calculated results of the model are in line with the experimental results.

Originality/value

Based on the comparative analysis of the test results and numerical simulation results of 11 test beams, this investigation verified the accuracy and reliability of the finite element simulation from the aspects of load–deflection curve, characteristic load and failure mode. Furthermore, based on load–deflection curve, the effects of steel plate width, ECC layer thickness, damage degree of the original beam and cross-sectional area of longitudinal tensile rebar on the ultimate bearing capacity and ductility of ESRB were discussed. Finally, a simplified method was put forward to further verify the effectiveness of ESRB through analytical calculation.

Details

International Journal of Structural Integrity, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 28 February 2019

Muhd Afiq Hizami Abdullah, Mohd Zulham Affandi Mohd Zahid, Afizah Ayob and Khairunnisa Muhamad

The purpose of this study is to investigate the effect on flexural strength of fire-damaged concrete repaired with high-strength mortar (HSM).

Abstract

Purpose

The purpose of this study is to investigate the effect on flexural strength of fire-damaged concrete repaired with high-strength mortar (HSM).

Design/methodology/approach

Reinforced concrete beams with dimension of 100 mm × 100 mm × 500 mm were used in this study. Beams were then heated to 400°C and overlaid with either HSM or high-strength fiber reinforced mortar (HSFM) to measure the effectiveness of repair material. Repaired beams of different material were then tested for flexural strength. Another group of beams was also repaired and tested by the same procedure but was heated at higher temperature of 600°C.

Findings

Repair of 400°C fire-damaged samples using HSM regained 72 per cent of its original flexural strength, 100.8 per cent of its original toughness and 56.9 per cent of its original elastic stiffness. Repair of 400°C fire-damaged samples using HSFM regained 113.5 per cent of its original flexural strength, 113 per cent of its original toughness and 85.1 per cent of its original elastic stiffness. Repair of 600°C fire-damaged samples using HSM regained 18.7 per cent of its original flexural strength, 25.9 per cent of its original peak load capacity, 26.1 per cent of its original toughness and 22 per cent of its original elastic stiffness. Repair of 600°C fire-damaged samples using HSFM regained 68.4 per cent of its original flexural strength, 96.5 per cent of its original peak load capacity, 71.2 per cent of its original toughness and 52.2 per cent of its original elastic stiffness.

Research limitations/implications

This research is limited to the size of the furnace. The beam specimen is limited to 500 mm of length and overall dimensions. This dimension is not practical in actual structure, hence it may cause exaggeration of deteriorating effect of heating on reinforced concrete beam.

Practical implications

This study may promote more investigation of using HSM as repair material for fire-damaged concrete. This will lead to real-world application and practical solution for fire-damaged structure.

Social implications

The aim of this research in using HSM mostly due to the material’s high workability which will ease its application and promote quality in repair of damaged structure.

Originality/value

There is a dearth of research on using HSM as repair material for fire-damaged concrete. Some research has been carried out using mortar but at lower strength compared to this research.

Details

Journal of Structural Fire Engineering, vol. 10 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 31 August 2022

Aya Qatawna, Rabab Allouzi and Samih Qaqish

The primary objective of this study is to produce one-way slabs made of LWFC with low density and sufficient compressive strength suitable for structural purpose then investigate…

Abstract

Purpose

The primary objective of this study is to produce one-way slabs made of LWFC with low density and sufficient compressive strength suitable for structural purpose then investigate their flexural behavior under various types of reinforcement and thickness of the slab and the influence of addition of PP fibers reinforcement on the mechanical behavior of reinforced concrete slabs. The specimens were tested using four-point loading. The results concerning load capacity, deflection and failure mode and crack pattern for each specimen were obtained. Also, an analytical investigation of PP fiber and GFG contribution on the flexural behavior of foamed concrete slabs is studied to investigate the significant role of PP fiber on the stress distribution in reinforced foam concrete and predict the flexural moment capacity.

Design/methodology/approach

The materials used in this study are cement, fine aggregate (sand), water, PP fibers, foaming agent, chemical additives if required, steel reinforcing rebars and glass fiber grid. The combination of these constituent materials will be used to produce foamed concrete in this research Then this study will present the experimental program of one-way foamed concrete slabs including slabs reinforced with GFR grids and another with steel reinforcements. The slabs will be tested in the laboratory under static loading conditions to investigate their ultimate capacities. The flexural behavior is to the interest of the slabs reinforced with GFR grids reinforcements in comparison with that of one with steel reinforcing rebars. Three groups are considered. (1) Group I: two slabs of PP fiber foamed concrete with minimum required reinforcements. (2) Group II: two slabs of PP fiber foamed concrete with glass fiber grids. (3) Group III: two slabs of PP fiber foamed concrete with the minimum required reinforcements and glass fiber grids.

Findings

The experimental results proved the effectiveness and efficiency of this the new system in producing a low density of concrete below 1900 kg/m3 had a corresponding strength of about 17 MPa at least. Besides, the presence of PP fibers had a noticeable improvement on the flexural strength values for all the examined slabs. It was found that the specimens reinforced with steel reinforcement mesh carried higher flexural capacity compared to these reinforced with GFG only. The specimens reinforced with GFG exhibited the lowest flexural capacity due to GFG separation from the concrete substrate. Also, an analytical investigation to predict the flexural strength of all tested specimens was carried out. The analytical results were agreed with the experimental results. Therefore, LWFC can be used as a substitute lightweight concrete material for the production of structural concrete applications in the construction industries today.

Research limitations/implications

Foamed concrete is a wide field to discuss. To achieve the objectives of the project, the study is focused on the foamed concrete with the following limitations: (1) because the aim of this research is to produce foamed concrete suitable for structural purposes, it is decided to produce mixes within the density range 1300–1900 kg/m3. (2) Simply-supported slabs are of considered. (3) This study also looks out by using GFR and without it.

Originality/value

The main objectives of this study were producing structural foamed concrete slabs and investigate their flexural response for residential uses.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 1 August 1944

J.L. Beilschmidt

IN an earlier article dealing with the general aspects of clastic distortion phenomena, which appeared in an issue of Aeronautics, mention was made of the various factors which…

Abstract

IN an earlier article dealing with the general aspects of clastic distortion phenomena, which appeared in an issue of Aeronautics, mention was made of the various factors which tend either to promote, or to damp out and eliminate the onset of the aerodynamic inertia elastic vibration phenomena known as flutter, and it was pointed out that in this respect the provision of an adequate measure of rigidity, both as regards to twisting and flexure of the wing or tail surface structure is one of the most effective safeguards against the occurrence of torsional‐flexural flutter.

Details

Aircraft Engineering and Aerospace Technology, vol. 16 no. 8
Type: Research Article
ISSN: 0002-2667

Article
Publication date: 12 June 2017

Danie Roy Anasco Bastin, Umesh Kumar Sharma and Pradeep Bhargava

The main aim of this research was to investigate the effectiveness of various strengthening techniques in restoring the structural performance of reinforced concrete (RC) beams…

Abstract

Purpose

The main aim of this research was to investigate the effectiveness of various strengthening techniques in restoring the structural performance of reinforced concrete (RC) beams damaged by elevated temperatures.

Design/methodology/approach

Three different strengthening techniques, namely, high-strength fibre reinforced concrete (HSFRC), ferrocement (FC) jacketing and externally bonded fibre-reinforced polymer (FRP) were used. Series of RC beams were casted, heated, strengthened and tested to investigate the influence of various variables. The variables of the study were type of strengthening and level of heat damage.

Findings

Externally bonded FRP was found to be the best among the various techniques, especially with respect to strength and stiffness restoration. On the contrary, the FRP strengthening was not that effective in restoring the energy absorption capacity of beams compared to HSFRC and FC techniques of strengthening. The chosen strengthening techniques were able to restore the failure mode of beams to flexural failure, which was found to have changed to shear failure in case of heated unstrenghthened beams.

Originality/value

This research program has contributed to the fundamental understanding of designing post fire retrofit solutions for RC beams.

Details

Journal of Structural Fire Engineering, vol. 8 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 14 August 2017

Hai Yan Zhang, Hao Ran Lv, Venkatesh Kodur and Shu Liang Qi

This paper aims to present performance comparison of fiber sheet-strengthened reinforced concrete (RC) beams bonded with geopolymer and epoxy resin under ambient and fire…

Abstract

Purpose

This paper aims to present performance comparison of fiber sheet-strengthened reinforced concrete (RC) beams bonded with geopolymer and epoxy resin under ambient and fire conditions.

Design/methodology/approach

This study presents experimental results of bending tests at ambient temperature and fire resistance tests on two control beams and eight fiber sheet-strengthened RC beams. The test variables include fiber sheet type (carbon fiber [CF] and basalt fiber [BF] sheet), number of layers of fiber sheet (one and two layers) and adhesive agent type (geopolymers and epoxy resin). Data generated from these tests were used to evaluate and compare the strengthening effectiveness of CF-reinforced polymer (CFRP) and CF-reinforced geopolymer (CFRG) at ambient temperature and under fire exposure conditions.

Findings

Test results clearly show that the CFRG system can provide good strengthening effectiveness on RC beams at ambient temperature, as the CFRP system, owing to excellent bond properties of geopolymers. Although geopolymers possess better bonding properties at high temperature than organic matrix, the strengthened beams bonded with geopolymer do not exhibit better fire resistance than that those bonded with epoxy resin, owing to early falling-off of fire insulation. Thus, in CFRG-strengthened beams, relevant measures are to be taken to minimize falling-off of fire insulation to achieve good fire resistance.

Originality/value

The presented results are from unique fire tests and provide valuable insight (and information) on the performance of fiber sheet-strengthened RC beams bonded with geopolymer and epoxy resin under ambient and fire conditions.

Details

Journal of Structural Fire Engineering, vol. 9 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 October 2003

H.Y. Leung and R.V. Balendran

Use of fibre‐reinforced polymer (FRP) composite rods, in lieu of steel rebars, as the main flexural reinforcements in reinforced concrete (RC) beams have recently been suggested…

2656

Abstract

Use of fibre‐reinforced polymer (FRP) composite rods, in lieu of steel rebars, as the main flexural reinforcements in reinforced concrete (RC) beams have recently been suggested by many researchers. However, the development of FRP RC beam design is still stagnant in the construction industry and this may be attributed to a number of reasons such as the high cost of FRP rods compared to steel rebars and the reduced member ductility due to the brittleness of FRP rods. To resolve these problems, one of the possible methods is to adopt both FRP rods and steel rebars to internally reinforce the concrete members. The effectiveness of this new reinforcing system remains problematic and continued research in this area is needed. An experimental study on the load‐deflection behaviour of concrete beams internally reinforced with glass fibre‐reinforced polymer (GFRP) rods and steel rebars was therefore conducted and some important findings are summarized in this paper.

Details

Structural Survey, vol. 21 no. 4
Type: Research Article
ISSN: 0263-080X

Keywords

1 – 10 of 156