Search results

1 – 10 of 269
Article
Publication date: 31 August 2022

Aya Qatawna, Rabab Allouzi and Samih Qaqish

The primary objective of this study is to produce one-way slabs made of LWFC with low density and sufficient compressive strength suitable for structural purpose then investigate…

Abstract

Purpose

The primary objective of this study is to produce one-way slabs made of LWFC with low density and sufficient compressive strength suitable for structural purpose then investigate their flexural behavior under various types of reinforcement and thickness of the slab and the influence of addition of PP fibers reinforcement on the mechanical behavior of reinforced concrete slabs. The specimens were tested using four-point loading. The results concerning load capacity, deflection and failure mode and crack pattern for each specimen were obtained. Also, an analytical investigation of PP fiber and GFG contribution on the flexural behavior of foamed concrete slabs is studied to investigate the significant role of PP fiber on the stress distribution in reinforced foam concrete and predict the flexural moment capacity.

Design/methodology/approach

The materials used in this study are cement, fine aggregate (sand), water, PP fibers, foaming agent, chemical additives if required, steel reinforcing rebars and glass fiber grid. The combination of these constituent materials will be used to produce foamed concrete in this research Then this study will present the experimental program of one-way foamed concrete slabs including slabs reinforced with GFR grids and another with steel reinforcements. The slabs will be tested in the laboratory under static loading conditions to investigate their ultimate capacities. The flexural behavior is to the interest of the slabs reinforced with GFR grids reinforcements in comparison with that of one with steel reinforcing rebars. Three groups are considered. (1) Group I: two slabs of PP fiber foamed concrete with minimum required reinforcements. (2) Group II: two slabs of PP fiber foamed concrete with glass fiber grids. (3) Group III: two slabs of PP fiber foamed concrete with the minimum required reinforcements and glass fiber grids.

Findings

The experimental results proved the effectiveness and efficiency of this the new system in producing a low density of concrete below 1900 kg/m3 had a corresponding strength of about 17 MPa at least. Besides, the presence of PP fibers had a noticeable improvement on the flexural strength values for all the examined slabs. It was found that the specimens reinforced with steel reinforcement mesh carried higher flexural capacity compared to these reinforced with GFG only. The specimens reinforced with GFG exhibited the lowest flexural capacity due to GFG separation from the concrete substrate. Also, an analytical investigation to predict the flexural strength of all tested specimens was carried out. The analytical results were agreed with the experimental results. Therefore, LWFC can be used as a substitute lightweight concrete material for the production of structural concrete applications in the construction industries today.

Research limitations/implications

Foamed concrete is a wide field to discuss. To achieve the objectives of the project, the study is focused on the foamed concrete with the following limitations: (1) because the aim of this research is to produce foamed concrete suitable for structural purposes, it is decided to produce mixes within the density range 1300–1900 kg/m3. (2) Simply-supported slabs are of considered. (3) This study also looks out by using GFR and without it.

Originality/value

The main objectives of this study were producing structural foamed concrete slabs and investigate their flexural response for residential uses.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 2 July 2020

Toqa AL-Kasasbeh and Rabab Allouzi

This research is part of a project that aims to investigate using foamed concrete structurally in houses. Foamed concrete has a porous structure that makes it light in weight

Abstract

Purpose

This research is part of a project that aims to investigate using foamed concrete structurally in houses. Foamed concrete has a porous structure that makes it light in weight, good in thermal insulation, good in sound insulation and workable.

Design/methodology/approach

An experimental program is conducted in this research to investigate the behavior of polypropylene fiber reinforced foam concrete beams laterally reinforced with/without glass fiber grid.

Findings

The results proved the effectiveness and efficiency of using glass fiber grid as lateral reinforcements on the shear strength of reinforced foam concrete ribs, in reducing the cracks width and increasing its shear capacity, contrary to using glass fiber grid of reinforced foam concrete beams since glass fiber grid did not play good role in beams.

Originality/value

Limited literature is available regarding the structural use of foam concrete. However, work has been done in many countries concerning its use as insulation material, while limited work was done on structural type of foam concrete.

Details

International Journal of Structural Integrity, vol. 12 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 14 July 2021

Irindu Upasiri, Chaminda Konthesingha, Anura Nanayakkara, Keerthan Poologanathan, Brabha Nagaratnam and Gatheeshgar Perampalam

In this study, the insulation fire ratings of lightweight foamed concrete, autoclaved aerated concrete and lightweight aggregate concrete were investigated using finite element…

218

Abstract

Purpose

In this study, the insulation fire ratings of lightweight foamed concrete, autoclaved aerated concrete and lightweight aggregate concrete were investigated using finite element modelling.

Design/methodology/approach

Lightweight aggregate concrete containing various aggregate types, i.e. expanded slag, pumice, expanded clay and expanded shale were studied under standard fire and hydro–carbon fire situations using validated finite element models. Results were used to derive empirical equations for determining the insulation fire ratings of lightweight concrete wall panels.

Findings

It was observed that autoclaved aerated concrete and foamed lightweight concrete have better insulation fire ratings compared with lightweight aggregate concrete. Depending on the insulation fire rating requirement of 15%–30% of material saving could be achieved when lightweight aggregate concrete wall panels are replaced with the autoclaved aerated or foamed concrete wall panels. Lightweight aggregate concrete fire performance depends on the type of lightweight aggregate. Lightweight concrete with pumice aggregate showed better fire performance among the normal lightweight aggregate concretes. Material saving of 9%–14% could be obtained when pumice aggregate is used as the lightweight aggregate material. Hydrocarbon fire has shown aggressive effect during the first two hours of fire exposure; hence, wall panels with lesser thickness were adversely affected.

Originality/value

Finding of this study could be used to determine the optimum lightweight concrete wall type and the optimum thickness requirement of the wall panels for a required application.

Details

Journal of Structural Fire Engineering, vol. 12 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 23 May 2022

Ghadeer Alabbadi and Rabab Allouzi

The purpose of this study is to improve the lateral capacity of Cold-Formed Steel (CFS) frame walls filled with lightweight foamed concrete (LFC) and supported with straw boards…

Abstract

Purpose

The purpose of this study is to improve the lateral capacity of Cold-Formed Steel (CFS) frame walls filled with lightweight foamed concrete (LFC) and supported with straw boards by introducing structural foamed concrete and/or bracing.

Design/methodology/approach

Finite element models are developed and calibrated based on previous experimental work. Then, these models are extended to conduct a parametric study to quantify the effect of filling CFS walls and structural LFC and the effect of supporting CFS walls with bracing.

Findings

Results of the study conclude that the finite element analysis can be used to simulate and analyze the lateral capacity of CFS walls effectively since the maximum deviation between calibrated and experimental results is 10%. The structural LFC usage in CFS walls improves the lateral capacity considerably by (25–75) % depending on the wall properties. Besides, the application of lateral bracing does not always have a positive effect on the lateral performance of these walls.

Originality/value

Although CFS walls are preferred due to it is light in weight, low in cost, easy to install and recyclable, low seismic performance, buckling vulnerability, poor thermal insulation and sound insulation properties, low lateral stiffness, and low shear strength limit their use. This study proposes the use of structural foamed concrete and a different bracing method than what is available in the literature. This can overcome the drawbacks of the CFS walls alone which can permit the usage of such walls in mid-rise buildings and other applications.

Details

International Journal of Structural Integrity, vol. 13 no. 4
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 11 August 2023

Hanadi Al-Zubaidi and Rabab Allouzi

Cement can be replaced to reduce the energy consumption and the environmental impact of cement. Also, foamed concrete can be used structurally in residential buildings to reduce…

Abstract

Purpose

Cement can be replaced to reduce the energy consumption and the environmental impact of cement. Also, foamed concrete can be used structurally in residential buildings to reduce weight and improve thermal insulation. To achieve these two goals, this paper aims to investigate the effect of basalt powder as a partial replacement of either cement or sand.

Design/methodology/approach

This paper investigates the effect of basalt powder as a partial replacement of either cement or sand on the mechanical properties of foamed concrete used to cast slabs. First, mechanical properties of foamed concrete are tested with and without replacement of basalt. Then, six slabs of different thicknesses and mixes are investigated. The thicknesses considered are 150- and 200-mm slabs. The three mixes used to construct these slabs are foamed concrete with no basalt powder, foamed concrete with replacement of 20% of cement by basalt powder and foamed concrete with replacement of 20% of sand by basalt powder. The flexural behavior of these slabs is investigated.

Findings

All the slabs failed in the commonly intended flexural mode. The results show that the basalt powder acted as a strong filler material in the foamed concrete mix based on mechanical properties and flexural behavior. The proposed foamed concrete slabs can be used structurally in residential buildings.

Originality/value

A natural waste material that can be used to promote energy efficiency and reduce emission is basalt. In this paper, basalt powder is suggested to be used due to its chemical composition that is similar to cement. Also, basalt powder is low in cost as it is waste, while basalt aggregate is prepared, and it is only used as filler in paved roads. Accordingly, basalt is partially used instead of cement to reduce the emission of carbon dioxide that results from the cement manufacturing. Also, it is used as a partial alternative to sand which can be considered as a new stronger source as filling material used in the production of concrete.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 17 January 2022

Irindu Upasiri, Chaminda Konthesingha, Anura Nanayakkara, Keerthan Poologanathan, Gatheeshgar Perampalam and Dilini Perera

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel…

Abstract

Purpose

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.

Design/methodology/approach

A Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.

Findings

Novel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.

Research limitations/implications

The developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.

Practical implications

LSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.

Originality/value

Limited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 20 December 2019

Norashidah Abd Rahman, Siti Amirah Azra Khairuddin, Mohd Faris Faudzi, Mohd Harith Imran Mohd Asri, Norwati Jamaluddin and Zainorizuan Mohd Jaini

Concrete-filled hollow section (CFHS) is widely used in steel construction. The combination of concrete and steel decreases buckling and deformation of steel. However, studies…

Abstract

Purpose

Concrete-filled hollow section (CFHS) is widely used in steel construction. The combination of concrete and steel decreases buckling and deformation of steel. However, studies reveal that using normal concrete increases the dead weight of a structure. Therefore, a lightweight concrete, such as foamed concrete (FC), is proposed to reduce the weight of the structure. The purpose of this study is to determine the strength of modified fibrous foamed CFHS (FCFHS).

Design/methodology/approach

Steel and polypropylene fibres were used with rice husk ash, and short column fibrous FCFHSs were tested under compression load. Greased and non-greased methods were adopted to determine bond strength and confining effect between steel and concrete.

Findings

Results indicate that the use of fibre in FCFHSs improves the strength of CFHS from 9% to 11%. The non-greased method confirms that an interaction exists between steel and concrete with a confinement coefficient of more than 2.0.

Originality/value

It can be shown that the modified fibrous foamed concrete can increase the strength of the concrete and can be used as concrete filled in steel construction industry.

Details

World Journal of Engineering, vol. 17 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 3 September 2019

Mariyana Aida Ab Kadir, Mohammad Iqbal Khiyon, Abdul Rahman Mohd. Sam, Ahmad Beng Hong Kueh, Nor Hasanah Abdul Shukor Lim, Muhammad Najmi Mohamad Ali Mastor, Nurizaty Zuhan and Roslli Noor Mohamed

The purpose of this paper is to examine the mechanical properties, material composition of spent garnet as a sand replacement in high-strength concrete at room and elevated…

Abstract

Purpose

The purpose of this paper is to examine the mechanical properties, material composition of spent garnet as a sand replacement in high-strength concrete at room and elevated temperatures. Bonding of the concrete containing spent garnet and reinforcing rebar is investigated. Moreover, the optimum thickness of concrete cover subjected to elevated temperatures is investigated.

Design/methodology/approach

First, the plain spent garnet was physically, chemically and thermally studied. Then, a series of concrete specimens with 0, 20, 40, 60, 80 and 100 per cent of spent garnet were prepared to determine the optimum percentage of spent garnet. Finally, the physical and mechanical behaviours of concrete specimens and effects of cover thickness on steel rebar when subjected to elevated temperature of 200°C, 400°C, 600°C and 800°C for 1 h were studied. It was observed that spent garnet was thermally stable compared to river sand.

Findings

Mechanical properties were found to be optimal for concrete with 40% spent garnet replacement. Physically, spent garnet concrete changed colour to brown at 400°C, and to whitish grey at 600°C. The residual compressive strength of spent garnet concrete was also found slightly higher than that for control specimens. At various high temperatures, the reduction in ultimate tensile stress for steel bar inside concrete cover of 30 mm was the lowest compared to that of 20 mm.

Research limitations/implications

Spalling effect it not considered in this study.

Practical implications

The optimum concrete cover is important issues in reinforced concrete design. This can be used as a guideline by structural designers when using a different type of concrete material in the construction.

Social implications

Utilization of the waste spent garnet reduces usage of natural aggregates in concrete production and enhances its performance at elevated temperatures. Natural aggregates are normally taken from sand and rock. The new innovation in concrete perhaps can produce light concrete, reduce the cost of concrete production and at the same time also mitigates environmental problems affect from waste material such as minimizing disposal area.

Originality/value

Utilization of spent garnet in ordinary Portland cement (OPC) concrete at high temperature is a new innovation. It shows that the concrete cover of the concrete element reduced as compared to the OPC concrete. Reduce in weight concrete however the strength of concrete is similar to conventional concrete. This study at elevated temperature has never been performed by any previous researcher.

Details

Journal of Structural Fire Engineering, vol. 10 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Abstract

Details

A Circular Argument
Type: Book
ISBN: 978-1-80071-385-7

Article
Publication date: 5 October 2022

Parvathidevi A. and Naga Satish Kumar Ch

This study aims to assess the efficacy of thermal analysis of concrete slabs by including different insulation materials using ANSYS. Regression equations were proposed to predict…

Abstract

Purpose

This study aims to assess the efficacy of thermal analysis of concrete slabs by including different insulation materials using ANSYS. Regression equations were proposed to predict the thermal conductivity using concrete density. As these simulation and regression analyses are essential tools in designing the thermal insulation concretes with various densities, they sequentially reduce the associated time, effort and cost.

Design/methodology/approach

Two grades of concretes were taken for thermal analysis. They were designed by replacing the natural fine aggregates with thermal insulation aggregates: expanded polystyrene, exfoliated vermiculite and light expanded clay. Density, temperature difference, specific heat capacity, thermal conductivity and time were measured by conducting experiments. This data was used to simulate concrete slabs in ANSYS. Regression analysis was performed to obtain the relation between density and thermal conductivity. Finally, the quality of the predicted regression equations was assessed using root mean square error (RMSE), mean absolute error (MAE), integral absolute error (IAE) and normal efficiency (NE).

Findings

ANSYS analysis on concrete slabs accurately estimates the thermal behavior of concrete, with lesser error value ranges between 0.19 and 7.92%. Further, the developed regression equations proved accurate with lower values of RMSE (0.013 to 0.089), MAE (0.009 to 0.088); IAE (0.216 to 5.828%) and higher values of NE (94.16 to 99.97%).

Originality/value

The thermal analysis accurately simulates the experimental transfer of heat across the concrete slab. Obtained regression equations proved helpful while designing the thermal insulation concrete.

Details

World Journal of Engineering, vol. 21 no. 1
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 10 of 269