Search results

1 – 10 of 111
Article
Publication date: 15 October 2021

Paulthurai Rajesh, Francis H. Shajin and Kumar Cherukupalli

The purpose of this paper is to track the maximal power of wind energy conversion system (WECS) and enhance the search capability for WECS maximum power point tracking (MPPT).

Abstract

Purpose

The purpose of this paper is to track the maximal power of wind energy conversion system (WECS) and enhance the search capability for WECS maximum power point tracking (MPPT).

Design/methodology/approach

The hybrid technique is the combination of tunicate swarm algorithm (TSA) and radial basis function neural network.

Findings

TSA gets input parameters from the rectifier outputs such as rectifier direct current (DC) voltage, DC current and time. From the input parameters, it enhances the reduced fault power of rectifier and generates training data set based on the MPPT conditions. The training data set is used in radial basis function. During the execution time, it produces the rectifier reference DC side voltage that is converted to control pulses of inverter switches.

Originality/value

Finally, the proposed method is executed in MATLAB/Simulink site, and the performance is compared with different existing methods like particle swarm optimization algorithm and hill climb searching technique. Then the output illustrates the performance of the proposed method and confirms its capability to solve issues.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 6 March 2024

Mouna Zerzeri, Intissar Moussa and Adel Khedher

The purpose of this paper aims to design a robust wind turbine emulator (WTE) based on a three-phase induction motor (3PIM).

Abstract

Purpose

The purpose of this paper aims to design a robust wind turbine emulator (WTE) based on a three-phase induction motor (3PIM).

Design/methodology/approach

The 3PIM is driven by a soft voltage source inverter (VSI) controlled by a specific space vector modulation. By adjusting the appropriate vector sequence selection, the desired VSI output voltage allows a real wind turbine speed emulation in the laboratory, taking into account the wind profile, static and dynamic behaviors and parametric variations for theoretical and then experimental analysis. A Mexican hat profile and a sinusoidal profile are therefore used as the wind speed system input to highlight the electrical, mechanical and electromagnetic system response.

Findings

The simulation results, based on relative error data, show that the proposed reactive power control method effectively estimates the flux and the rotor time constant, thus ensuring an accurate trajectory tracking of the wind speed for the wind emulation application.

Originality/value

The proposed architecture achieves its results through the use of mathematical theory and WTE topology combine with an online adaptive estimator and Lyapunov stability adaptation control methods. These approaches are particularly relevant for low-cost or low-power alternative current (AC) motor drives in the field of renewable energy emulation. It has the advantage of eliminating the need for expensive and unreliable position transducers, thereby increasing the emulator drive life. A comparative analysis was also carried out to highlight the online adaptive estimator fast response time and accuracy.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 20 December 2023

Indira Damarla, Venmathi M., Krishnakumar V. and Anbarasan P.

In this paper, a new front end converter (FEC) topology has been proposed for the switched reluctance (SR) motor drive. This study aims to present the performance analysis of…

Abstract

Purpose

In this paper, a new front end converter (FEC) topology has been proposed for the switched reluctance (SR) motor drive. This study aims to present the performance analysis of FEC-based SR motor drive using various types of control schemes like conventional proportional integral (PI) controller, fuzzy logic controller (FLC) and fuzzy-tuned proportional integral controller (Fuzzy-PI).

Design/methodology/approach

The proposed FEC-based SR motor drive with various control strategies is derived for the torque ripple minimization and speed control.

Findings

The steady state and the dynamic response of the FEC-based SR motor drive are analyzed using three different controllers under change in speed and loading conditions. The Fuzzy-PI-based control scheme improves the dynamic response of the system when compared with the FLC and the conventional PI controller.

Originality/value

The hardware prototype has been implemented for the FEC-based SR motor drive by using the Xilinx SPARTAN 6 FPGA processor. The experimental verification has been conducted and the results have been measured under steady state and dynamic conditions.

Details

Circuit World, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 8 April 2024

Essaki Raj R. and Sundaramoorthy Sridhar

This paper aims at developing an improved method, based on binary search algorithm (BSA) for the steady-state analysis of self-excited induction generators (SEIGs), which are…

Abstract

Purpose

This paper aims at developing an improved method, based on binary search algorithm (BSA) for the steady-state analysis of self-excited induction generators (SEIGs), which are increasingly used in wind energy electric conversion systems. The BSA is also compared with linear search algorithm (LSA) to bring out the merits of BSA over LSA.

Design/methodology/approach

All the parameters of SEIG, including the varying core loss of the machine, have been considered to ensure accuracy in the predetermined performance values of the set up. The nodal admittance method has been adopted to simplify the equivalent circuit of the generator and load. The logic and steps involved in the formulation of the complete procedure have been illustrated using elaborate flowcharts.

Findings

The proposed approach is validated by the experimental results, obtained on a three-phase 240 V, 5.0 A, 2.0 kW SEIG, which closely match with the corresponding predicted performance values. The analysis is shown to be easy to implement with reduced computation time.

Originality/value

A novel improved and simplified technique has been formulated for estimating the per unit frequency (a), magnetizing reactance (Xm) and core loss resistance (Rm) of the SEIG using the nodal admittance of its equivalent circuit. The accuracy of the predetermined performance is enhanced by considering the SEIG’s varying core loss. Only simple MATLAB programming has been used for adopting the algorithms.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 22 March 2024

Shahin Alipour Bonab, Alireza Sadeghi and Mohammad Yazdani-Asrami

The ionization of the air surrounding the phase conductor in high-voltage transmission lines results in a phenomenon known as the Corona effect. To avoid this, Corona rings are…

Abstract

Purpose

The ionization of the air surrounding the phase conductor in high-voltage transmission lines results in a phenomenon known as the Corona effect. To avoid this, Corona rings are used to dampen the electric field imposed on the insulator. The purpose of this study is to present a fast and intelligent surrogate model for determination of the electric field imposed on the surface of a 120 kV composite insulator, in presence of the Corona ring.

Design/methodology/approach

Usually, the structural design parameters of the Corona ring are selected through an optimization procedure combined with some numerical simulations such as finite element method (FEM). These methods are slow and computationally expensive and thus, extremely reducing the speed of optimization problems. In this paper, a novel surrogate model was proposed that could calculate the maximum electric field imposed on a ceramic insulator in a 120 kV line. The surrogate model was created based on the different scenarios of height, radius and inner radius of the Corona ring, as the inputs of the model, while the maximum electric field on the body of the insulator was considered as the output.

Findings

The proposed model was based on artificial intelligence techniques that have high accuracy and low computational time. Three methods were used here to develop the AI-based surrogate model, namely, Cascade forward neural network (CFNN), support vector regression and K-nearest neighbors regression. The results indicated that the CFNN has the highest accuracy among these methods with 99.81% R-squared and only 0.045468 root mean squared error while the testing time is less than 10 ms.

Originality/value

To the best of the authors’ knowledge, for the first time, a surrogate method is proposed for the prediction of the maximum electric field imposed on the high voltage insulators in the presence Corona ring which is faster than any conventional finite element method.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 6 September 2022

Feng Zhou, Zixuan Wang and Yuxiang Zhao

The purpose of this paper is to study the pipe-type electromagnetic induction heating device under power frequency condition.

46

Abstract

Purpose

The purpose of this paper is to study the pipe-type electromagnetic induction heating device under power frequency condition.

Design/methodology/approach

To reduce eddy current loss and improve heating efficiency, the structure of a pipe-type power-frequency electromagnetic heating device was optimized. Based on the maximum load flow formula, a parallel excitation winding structure is designed, and the distribution of electromagnetic field under four different powers is analyzed by simulation. Four heating modes were proposed according to the structure of diversion ring, inner wall and outer wall. Two heating modes with better heating effect were obtained by comprehensively considering the factors such as magnetic field distribution, thermal power and energy consumption.

Findings

The double-wall structure of the pipe-type electromagnetic heating device can make the heat source distribution more uniform, and the use of power-frequency power supply can increase security, the installation of diversion ring can make the heating more sufficient and the heating efficiency of the two heating methods selected according to the structural performance is more than 90%.

Originality/value

In view of the medium or high frequency of pipe-type electromagnetic heating device, it is necessary to configure high power electronic frequency conversion drive system, and eddy current can only be produced on the tube wall, resulting in uneven distribution of heat sources. A pipe-type power-frequency electromagnetic heating device with double-wall structure was proposed.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 24 April 2024

Ali M. AlQahtani

Jubail Industrial City is one of the largest industrial centers in the Middle East, offering potential opportunities for renewable energy generation. This research paper presents…

Abstract

Purpose

Jubail Industrial City is one of the largest industrial centers in the Middle East, offering potential opportunities for renewable energy generation. This research paper presents a comprehensive analysis of the wind resources in Jubail Industrial City and proposes the design of a smart grid-connected wind farm for this strategic location.

Design/methodology/approach

The study used wind data collected at three different heights above ground level – 10, 50 and 90 m – over four years from 2017 to 2020. Key parameters, such as average wind speeds (WS), predominant wind direction, Weibull shape, scale parameters and wind power density (WPD), were analyzed. The study used Windographer, an exclusive software program designed to evaluate wind resources.

Findings

The average WS at the respective heights were 3.07, 4.29 and 4.58 m/s. The predominant wind direction was from the north-west. The Weibull shape parameter (k) at the three heights was 1.77, 2.15 and 2.01, while the scale parameter (c) was 3.36, 4.88 and 5.33 m/s. The WPD values at different heights were 17.9, 48.8 and 59.3 W/m2, respectively.

Originality/value

The findings suggest that Jubail Industrial City possesses favorable wind resources for wind energy generation. The proposed smart grid-connected wind farm design demonstrates the feasibility of harnessing wind power in the region, contributing to sustainable energy production and economic benefits.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 22 March 2021

Sathish K. R. and T. Ananthapadmanabha

This paper aims to propose, the multi-objective method for optimal planning and operation of distributed generators (DGs) on distribution system (DS) using hybrid technique is…

Abstract

Purpose

This paper aims to propose, the multi-objective method for optimal planning and operation of distributed generators (DGs) on distribution system (DS) using hybrid technique is proposed.

Design/methodology/approach

The proposed hybrid technique denotes hybrid wrapper of black widow optimization algorithm (BWOA) and bear smell search algorithm (BSSA). BWOA accelerates the convergence speed with combination of the search strategy of BSSA; hence, it is named as improved black widow-bear smell search algorithm (IBWBSA) technique.

Findings

The multiple-objective operation denotes reducing generation cost, power loss, voltage deviation with optimally planning and operating the DS. For setting up the DG units on DS, IBWBSA technique is equipped to simultaneously reconfigure and find the optimal areas.

Originality/value

In this planning model, the constraints are power balance, obvious power flow limit, bus voltage, distribution substation’s capacity and cost. Then, proposed multiple-objective hybrid method to plan electrical distribution scheme is executed in the MATLAB/Simulink work site.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 12 April 2024

Miguel Afonso Sellitto, Maria Soares de Lima, Leandro Tomasin da Silva, Nelson Kadel Jr and Maria Angela Butturi

The purpose of the article is to identify relevant criteria for decision support in the implementation of waste-to-energy (WtE)-based systems.

Abstract

Purpose

The purpose of the article is to identify relevant criteria for decision support in the implementation of waste-to-energy (WtE)-based systems.

Design/methodology/approach

The methodology is a simple case study with a qualitative approach. Five experts involved in the project of a thermoelectric power plant qualitatively evaluated, on a Likert scale, a decision model with 15 indicators derived from recent studies. The research object was the first stage of a project to implement a thermoelectric plant employing municipal solid waste (MSW) in southern Brazil.

Findings

The study identified 15 criteria supporting the decision-making process regarding WtE implementation for MSW in a mid-sized city in southern Brazil. The study identified that compliance with MSW legislation, compliance with energy legislation, initial investment and public health impact are the most influential criteria. The study offered two models for decision processes: a simplified one and a complete one, with ten and fifteen indicators, respectively.

Research limitations/implications

The study concerns mid-sized municipalities in southern Brazil.

Practical implications

Municipal public managers have now a methodology based on qualitative evaluation that admits multiple perspectives, such as technical, economic, environmental and social, to support decision-making processes on WtE technologies for MSW.

Social implications

MSW management initiatives can yield jobs and revenues for vulnerable populations and provide a correct destination for MSW, mainly in developing countries.

Originality/value

The main originality is that now municipal public decision-makers have a structured model based on four constructs (technical, economic, environmental and social) deployed in 15 indicators to support decision-making processes involving WtE and MSW management.

Details

Benchmarking: An International Journal, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1463-5771

Keywords

Article
Publication date: 2 April 2024

Chenyu Zhang, Hongtao Xu and Yaodong Da

Thermal protection of a flange is critical for preventing tower icing and collapse of wind turbines (WTs) in extremely cold weather. This study aims to develop a novel thermal…

22

Abstract

Purpose

Thermal protection of a flange is critical for preventing tower icing and collapse of wind turbines (WTs) in extremely cold weather. This study aims to develop a novel thermal protection system for the WTs flanges using an electrical heat-tracing element.

Design/methodology/approach

A three-dimensional model and the Poly-Hexacore mesh structure are used, and the fluid-solid coupling method was validated and then deployed to analyze the heat transfer and convection process. Intra-volumetric heat sources are applied to represent the heat generated by the heating element, and the dynamic boundary conditions are considered. The steady temperature and temperature uniformity of the flange are the assessment criteria for the thermal protection performance of the heating element.

Findings

Enlarging the heating area and increasing the heating power improved the flange's temperature and temperature uniformity. A heating power of 4.9 kW was suitable for engineering applications with the lowest temperature nonuniformity. Compared with continuous heating, the increased temperature nonuniformity was buffered, and the electrical power consumption was reduced by half using pulse heating. Pulse heating time intervals of 1, 3 and 4 h were determined for the spring, autumn and winter, respectively.

Originality/value

The originality of this study is to propose a novel electrical heat-tracing thermal protection system for the WTs flanges. The effect of different arrangements, heating powers and heating strategies was studied, by which the theoretical basis is provided for a stable and long-term utilization of the WT flange.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0961-5539

Keywords

1 – 10 of 111