Search results

1 – 10 of over 11000
Article
Publication date: 5 June 2023

Takumi Yamaguchi and Fuminobu Ozaki

The main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope…

46

Abstract

Purpose

The main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections at fire and post fire.

Design/methodology/approach

Steady-state tests from ambient temperature (20 °C) to 800 °C, transient-state tests under the allowable design tensile force and tensile tests in an ambient temperature environment after heating (heating temperatures of 200–800 °C) were conducted.

Findings

The tensile strengths of the wire rope and end-connection specimens at both fire and post fire were obtained. The steel wire rope specimens possessed larger reduction factors than general hot-rolled mild steels (JIS SS400) and high-strength steel bolts (JIS F10T). The end-connection specimens with sufficient socket lengths exhibited ductile fracture of the wire rope part at both fire and post fire; however, those with short socket lengths experienced a pull-out fracture at the socket.

Originality/value

The fundamental and important tensile test results of the super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections were accumulated at fire and post fire, and the fracture modes were clarified. The obtained test results contribute to fire resistance performance-based design of cable steel structures at fire and fire-damage investigations to consider their reusability post fire.

Open Access
Article
Publication date: 7 December 2022

Milad Shabanian and Nicole Leo Braxtan

Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled…

Abstract

Purpose

Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled connections was investigated at ambient temperature (AT) and after and during non-standard fire exposure.

Design/methodology/approach

Three AT tests were conducted to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Two post-fire performance (PFP) tests were performed to study the impact of 30-min (PFP30) and 60-min (PFP60) partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were exposed to fire in a custom-designed frame, then cooled and loaded to failure. A fire performance (FP) test was conducted to study the fire resistance (FR) during non-standard fire exposure by simultaneously applying fire and a mechanical load equal to 65% of the AT load carrying capacity.

Findings

At AT, embedment failure of the dowels followed by splitting failure at the Glulam-beam and tensile failure of the epoxy between the layers of CLT-walls were the dominant failure modes. In both PFP tests, the plastic bending of the dowels was the only observed failure mode. The residual strength of the assembly was reduced 14% after 30 min and 37% after 60 min of fire exposure. During the FP test, embedment failure of timber in contact with the dowels was the only major failure mode, with the maximum rate of displacement at 51 min into the fire exposure.

Originality/value

This is the first time that the thermomechanical performance of such an assembly with a full-contact connection is presented.

Details

Journal of Structural Fire Engineering, vol. 14 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 September 2019

Adam Roman Petrycki and Osama (Sam) Salem

In fire condition, the time to failure of a timber connection is mainly reliant on the wood charring rate, the strength of the residual wood section, and the limiting temperature…

212

Abstract

Purpose

In fire condition, the time to failure of a timber connection is mainly reliant on the wood charring rate, the strength of the residual wood section, and the limiting temperature of the steel connectors involved in the connection. The purpose of this study is to experimentally investigate the effects of loaded bolt end distance, number of bolt rows, and the existence of perpendicular-to-wood grain reinforcement on the structural fire behavior of semi-rigid glued-laminated timber (glulam) beam-to-column connections that used steel bolts and concealed steel plate connectors.

Design/methodology/approach

In total, 16 beam-to-column connections, which were fabricated in wood-steel-wood bolted connection configurations, in eight large-scale sub-frame test assemblies were exposed to elevated temperatures that followed CAN/ULC-S101 standard time-temperature curve, while being subjected to monotonic loading. The beam-to-column connections of four of the eight test assemblies were reinforced perpendicular to the wood grain using self-tapping screws (STS). Fire tests were terminated upon achieving the failure criterion, which predominantly was dependent on the connection’s maximum allowed rotation.

Findings

Experimental results revealed that increasing the number of bolt rows from two to three, each of two bolts, increased the connection’s time to failure by a greater time increment than that achieved by increasing the bolt end distance from four- to five-times the bolt diameter. Also, the use of STS reinforcement increased the connection’s time to failure by greater time increments than those achieved by increasing the number of bolt rows or the bolt end distance.

Originality/value

The invaluable experimental data obtained from this study can be effectively used to provide insight and better understanding on how mass-timber glulam bolted connections can behave in fire condition. This can also help in further improving the existing design guidelines for mass-timber structures. Currently, beam-to-column wood connections are designed mainly as axially loaded connections with no guidelines available for determining the fire resistance of timber connections exerting any degree of moment-resisting capability.

Details

Journal of Structural Fire Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 15 June 2022

Mohamed A. Shaheen, Lee S. Cunningham and Andrew S.J. Foster

The effect of bolt stripping failure on the ductility of steel end plate beam-column connections has received relatively little investigation to date. The objective with the…

Abstract

Purpose

The effect of bolt stripping failure on the ductility of steel end plate beam-column connections has received relatively little investigation to date. The objective with the present work is to establish a validated numerical model of end plate connections at elevated temperatures, which predicts the mechanical behaviour and failure modes observed in the experimental tests including the bolt stripping failure. Furthermore, the validated FE model was used to investigate the effect of stripping failure on both the rotational and load-bearing capacity of end plate connection.

Design/methodology/approach

The analysis was conducted on a validated numerical model of end plate connections at elevated temperatures, which predicts the mechanical behaviour and failure modes observed in the experimental tests including the bolt stripping failure. The material was modelled considering ductile damage initiation and evolution featured in ABAQUS/Standard.

Findings

This study demonstrates that thick end plates can prevent stripping failure which significantly improves the rotational capacity of the connection. This failure mode can develop readily with thin end plates; however the effect is often unrealistically mitigated through idealised experimental tests. The rotational capacity of a connection can be 5.0 times higher if stripping failure is avoided, particularly at elevated temperatures. Eurocode 3 part 1.8 does not consider the possibility of stripping failure when discussing the requirements for plastic analysis. It is concluded in the present study that by allowing for the possibility of bolt stripping, the mode of failure can often shift from end plate failure to bolt stripping, this in turn significantly reduces the connection rotational capacity.

Originality/value

The effect of bolt stripping failure on the ductility of steel end plate beam-column connections has received relatively little investigation to date.

Details

Journal of Structural Fire Engineering, vol. 14 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 5 May 2023

Grzegorz Budzik, Tomasz Dziubek, Łukasz Paweł Przeszłowski, Bartłomiej Sobolewski, Mariusz Dębski and Małgorzata Ewa Gontarz

Manufacturing of products loaded with torque in an incremental process should take into account the strength in relation to the internal structure of the details. Incremental…

Abstract

Purpose

Manufacturing of products loaded with torque in an incremental process should take into account the strength in relation to the internal structure of the details. Incremental processes allow for obtaining various internal structures, both in the production process itself and as a result of designing a three-dimensional computer-aided design model with programmable strength. Finite element analysis (FEA) is often used in the modeling process, especially in the area of topological optimization. There is a lack of data for numerical simulation processes, especially for the design of products loaded with torque and manufactured additive manufacturing (AM). The purpose of this study is to present the influence of the internal structure of samples produced in the material extrusion (MEX) technology on the tested parameters in the process of unidirectional torsion and to present the practical application of the obtained results on the example of a spline connection.

Design/methodology/approach

The work involved a process of unidirectional torsion of samples with different internal structures, produced in the MEX technology. The obtained results allowed for the FEA of the spline connection, which was compared with the test of unidirectional torsion of the connection.

Findings

The performance of the unidirectional torsion test and the obtained results allowed us to determine the influence of the internal structure and its density on the achieved values of the tested parameters of the analyzed prototype materials. The performed FEA of the spline connection reflects the deformation of the produced connection in the unidirectional torsion test.

Originality/value

There are no standards for the torsional strength of elements manufactured from polymeric materials using MEX methods, which is why the industry often does not use these methods due to the need to spend time on research, which is associated with high costs. In addition, the industry is vary of unknown solutions and limits their use. Therefore, it is important to determine, among others, the strength parameters of components manufactured using incremental methods, including MEX, so that they can be widely used because of their great potential and thus gain trust among the recipient market. In addition, taking into account the different densities of the applied filling structure of the samples made of six prototype materials commonly available from manufacturers allowed us to determine its effect on the torsional strength. The presented work can be the basis for constructors dealing with the design of elements manufactured in the MEX technology in terms of torsional strength. The obtained results also complement the existing material base in the FEA software and perform the strength analysis before the actual details are made to verify the existing irregularities that affect the strength of the details. The analysis of unidirectional torsion made it possible to supplement the material cards, which often refer to unprocessed material, e.g. in MEX processes.

Details

Rapid Prototyping Journal, vol. 29 no. 8
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 17 December 2021

Faisal Faisal, Rizki Ridhasyah and Haryanto Haryanto

This study examines the mediating effect of sustainability disclosure on the relationship between political connections and firm performance from the resource-based view.

Abstract

Purpose

This study examines the mediating effect of sustainability disclosure on the relationship between political connections and firm performance from the resource-based view.

Design/methodology/approach

The sample of this study was sourced from 888 public companies listed on the Indonesia Stock Exchange (IDX) from 2016 to 2017. Path analysis and Sobel tests were used to determine the mediating effect of sustainability disclosure.

Findings

The results show that political connections have a positive and significant influence on firm performance. Furthermore, sustainability disclosures mediate the relationship between political connections and firm performance.

Research limitations/implications

In the context of developing countries such as Indonesia, managers can make the existence of parties in politically connected companies as a medium to demonstrate their adherence to external stakeholders through the disclosure of sustainability information.

Originality/value

This study is the first to investigate the mediating effect of sustainability disclosure on the relationship between political connections and firm performance, especially in emerging markets. The parties of the politically connected companies use a social responsibility mechanism as a medium that can sustain their operational sustainability whilst gaining long-term economic benefits.

Details

International Journal of Emerging Markets, vol. 18 no. 10
Type: Research Article
ISSN: 1746-8809

Keywords

Article
Publication date: 17 May 2023

Abbas Rezaeian, Mona Mansoori and Amin Khajehdezfuly

Top-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded…

Abstract

Purpose

Top-seat angle connection is known as one of the usual uncomplicated beam-to-column joints used in steel structures. This article investigates the fire performance of welded top-seat angle connections.

Design/methodology/approach

A finite element (FE) model, including nonlinear contact interactions, high-temperature properties of steel, and material and geometric nonlinearities was created for accomplishing the fire performance analysis. The FE model was verified by comparing its simulation results with test data. Using the verified model, 24 steel-framed top-seat angle connection assemblies are modeled. Parametric studies were performed employing the verified FE model to study the influence of critical factors on the performance of steel beams and their welded angle joints.

Findings

The results obtained from the parametric studies illustrate that decreasing the gap size and the top angle size and increasing the top angles thickness affect fire behavior of top-seat angle joints and decrease the beam deflection by about 16% at temperatures beyond 570 °C. Also, the fire-resistance rating of the beam with seat angle stiffener increases about 15%, compared to those with and without the web stiffener. The failure of the beam happens when the deflections become more than span/30 at temperatures beyond 576 °C. Results also show that load type, load ratio and axial stiffness levels significantly control the fire performance of the beam with top-seat angle connections in semi-rigid steel frames.

Originality/value

Development of design methodologies for these joints and connected beam in fire conditions is delayed by current building codes due to the lack of adequate understanding of fire behavior of steel beams with welded top-seat angle connections.

Details

Journal of Structural Fire Engineering, vol. 15 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Open Access
Article
Publication date: 29 August 2023

Qingfeng Xu, Hèrm Hofmeyer and Johan Maljaars

Simulations exist for the prediction of the behaviour of building structural systems under fire, including two-way coupled fire-structure interaction. However, these simulations…

Abstract

Purpose

Simulations exist for the prediction of the behaviour of building structural systems under fire, including two-way coupled fire-structure interaction. However, these simulations do not include detailed models of the connections, whereas these connections may impact the overall behaviour of the structure. Therefore, this paper proposes a two-scale method to include screw connections.

Design/methodology/approach

The two-scale method consists of (a) a global-scale model that models the overall structural system and (b) a small-scale model to describe a screw connection. Components in the global-scale model are connected by a spring element instead of a modelled screw, and the stiffness of this spring element is predicted by the small-scale model, updated at each load step. For computational efficiency, the small-scale model uses a proprietary technique to model the behaviour of the threads, verified by simulations that model the complete thread geometry, and validated by existing pull-out experiments. For four screw failure modes, load-deformation behaviour and failure predictions of the two-scale method are verified by a detailed system model. Additionally, the two-scale method is validated for a combined load case by existing experiments, and demonstrated for different temperatures. Finally, the two-scale method is illustrated as part of a two-way coupled fire-structure simulation.

Findings

It was shown that proprietary ”threaded connection interaction” can predict thread relevant failure modes, i.e. thread failure, shank tension failure, and pull-out. For bearing, shear, tension, and pull-out failure, load-deformation behaviour and failure predictions of the two-scale method correspond with the detailed system model and Eurocode predictions. Related to combined load cases, for a variety of experiments a good correlation has been found between experimental and simulation results, however, pull-out simulations were shown to be inconsistent.

Research limitations/implications

More research is needed before the two-scale method can be used under all conditions. This relates to the failure criteria for pull-out, combined load cases, and temperature loads.

Originality/value

The two-scale method bridges the existing very detailed small-scale screw models with present global-scale structural models, that in the best case only use springs. It shows to be insightful, for it contains a functional separation of scales, revealing their relationships, and it is computationally efficient as it allows for distributed computing. Furthermore, local small-scale non-convergence (e.g. a screw failing) can be handled without convergence problems in the global-scale structural model.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 15 March 2023

Shufeng Tang, Renjie Huang, Guoqing Zhao and Guoqing Wang

The purpose of this paper is that the modular mobile robots reformed the multimachine joint mode to achieve obstacle-crossing, climbing and other multifunctional inspection in…

Abstract

Purpose

The purpose of this paper is that the modular mobile robots reformed the multimachine joint mode to achieve obstacle-crossing, climbing and other multifunctional inspection in unstructured environment under the connection of the cone–hole docking mechanism.

Design/methodology/approach

An arc-shaped docking cone head with a posture-maintaining spring and two arc-shaped connecting rods that formed a ring round hole were designed to achieve large tolerance docking. Before active locking, the coordination between structures was used to achieve passive locking, which mitigated the docking impact of modular robots in unstructured environment. Using the locking ring composed of the two arc-shaped connecting rods, open-loop and closed-loop motion characteristics were obtained through the mutual motion of the connecting rod and the sliding block to achieve active locking, which not only ensured high precision docking, but also achieved super docking stability.

Findings

The cone–hole docking mechanism had the docking tolerance performance of position deviation of 6mm and pitch deviation of 8° to achieve docking of six degrees of freedom (6-DOF), which had a load capacity of 230 N to achieve super docking stability. Under the connection of the cone–hole docking mechanism, the modular mobile robots reformed the multimachine joint mode to achieve obstacle-crossing, climbing and other multifunctional inspection in unstructured environment.

Originality/value

Based on mechanical analysis of universal models, a cone–hole docking mechanism combining active and passive functions, six-dimensional constraints could be implemented, was proposed in this paper. The characteristics of the posture-maintaining spring in the cone docking head and the compression spring at the two ends of two arc-shaped connecting rods were used to achieve docking with large tolerance. Passive locking and active locking modules were designed, mitigating impact load and the locking did not require power to maintain, which not only ensured high precision docking, but also achieved super docking stability.

Details

Industrial Robot: the international journal of robotics research and application, vol. 50 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 31 March 2023

Huseyin Saglik, Airong Chen and Rujin Ma

Beginners and even experienced ones have difficulties in completing the structural fire analysis due to numerical difficulties such as convergence errors and singularity and have…

Abstract

Purpose

Beginners and even experienced ones have difficulties in completing the structural fire analysis due to numerical difficulties such as convergence errors and singularity and have to spend a lot of time making many repetitive changes on the model. The aim of this article is to highlight the advantages of explicit solver which can eliminate the mentioned difficulties in finite element analysis containing highly nonlinear contacts, clearance between modeled parts at the beginning and large deflections because of high temperature. This article provides important information, especially for researchers and engineers who are new to structural fire analysis.

Design/methodology/approach

The finite element method is utilized to achieve mentioned purposes. First, a comparative study is conducted between implicit and explicit solvers by using Abaqus. Then, a validation process is carried out to illustrate the explicit process by using sequentially coupled heat transfer and structural analysis.

Findings

Explicit analysis offers an easier solution than implicit analysis for modeling multi-bolted connections under high temperatures. An optimum mesh density for bolted connections is presented to reflect the realistic structural behavior. Presented explicit process with the offered mesh density is used in the validation of an experimental study on multi-bolted splice connection under ISO 834 standard fire curve. A good agreement is achieved.

Originality/value

What makes the study valuable is that the points to be considered in the structural fire analysis are examined and it is a guide that future researchers can benefit from. This is especially true for modeling and analysis of multi-bolted connections in finite element software under high temperatures. The article can help to shorten and even eliminate the iterative debugging phases, which is a problematic and very time-consuming process for many researchers.

Details

Journal of Structural Fire Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

1 – 10 of over 11000