Search results

1 – 10 of 38
Article
Publication date: 25 July 2024

Shashikant Mahadev Nagargoje and Milinda Ashok Mahajan

The purpose of this paper is to study the shearing performance under bi-directional loading of an interior beam–column joint (BCJ) sub-assemblage using the finite element analysis…

Abstract

Purpose

The purpose of this paper is to study the shearing performance under bi-directional loading of an interior beam–column joint (BCJ) sub-assemblage using the finite element analysis (FEA) tool (midas fea), validated in this research.

Design/methodology/approach

The BCJ can be defined as an essential part of the column that transfers the forces at the ends of the members connected to it. The members of the rigid jointed plane frame resist external forces by developing twisting moment, bending moment, axial force and shear force in the frame members. On the type of joints, the response to the action of lateral loads depends on reinforced concrete (RC) framed structures. The joint is considered rigid if the angle between the members remains unchanged during the structural deformation. This work examined the shear deformation, load displacement and strength of a non-seismically detailed internal concentric RC joint using non-linear FEA. The bi-directional loading imposes the oblique compression zone on one joint corner. This joint core’s oblique compression strut mechanism differs significantly from that under unidirectional loading. The numerical results are compared with experimental results in this study, with the data published in the literature.

Findings

Numerical analysis results show that, in the comparative study of numerical and experimental values, the FEA tool predicts the behaviour of the RC BCJ well. The discrepancy between the experimental and numerical results amounts to 6 to 12% end displacement of the beam, 7% resultant joint shear force, 4.23% column bar strain and 0.70% hoop strain.

Originality/value

The current code of practice describes the joint sub-assemblage behaviour along the single axis individually. In the non-orthogonal system, the superposition of the two axes for joint space results in overlapping the stresses and, hence, the formation of the oblique strut. This may result in a reduction in the joint capacity under bi-directional loading. The behaviour must be explored in depth, and an attempt is made for further exploration.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 5 March 2024

Maria Ghannoum, Joseph Assaad, Michel Daaboul and Abdulkader El-Mir

The use of waste polyethylene terephthalate (PET) plastics derived from shredded bottles in concrete is not formalized yet, especially in reinforced members such as beams and…

Abstract

Purpose

The use of waste polyethylene terephthalate (PET) plastics derived from shredded bottles in concrete is not formalized yet, especially in reinforced members such as beams and columns. The disposal of plastic wastes in concrete is a viable alternative to manage those wastes while minimizing the environmental impacts associated to recycling, carbon dioxide emissions and energy consumption.

Design/methodology/approach

This paper evaluates the suitability of 2D deterministic and stochastic finite element (FE) modeling to predict the shear strength behavior of reinforced concrete (RC) beams without stirrups. Different concrete mixtures prepared with 1.5%–4.5% PET additions, by volume, are investigated.

Findings

Test results showed that the deterministic and stochastic FE approaches are accurate to assess the maximum load of RC beams at failure and corresponding midspan deflection. However, the crack patterns observed experimentally during the different stages of loading can only be reproduced using the stochastic FE approach. This later method accounts for the concrete heterogeneity due to PET additions, allowing a statistical simulation of the effect of mechanical properties (i.e. compressive strength, tensile strength and Young’s modulus) on the output FE parameters.

Originality/value

Data presented in this paper can be of interest to civil and structural engineers, aiming to predict the failure mechanisms of RC beams containing plastic wastes, while minimizing the experimental time and resources needed to estimate the variability effect of concrete properties on the performance of such structures.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 29 February 2024

Yasser M. Mater, Ahmed A. Elansary and Hany A. Abdalla

The use of recycled coarse aggregate in concrete structures promotes environmental sustainability; however, performance of these structures might be negatively impacted when it is…

Abstract

Purpose

The use of recycled coarse aggregate in concrete structures promotes environmental sustainability; however, performance of these structures might be negatively impacted when it is used as a replacement to traditional aggregate. This paper aims to simulate recycled concrete beams strengthened with carbon fiber-reinforced polymer (CFRP), to advance the modeling and use of recycled concrete structures.

Design/methodology/approach

To investigate the performance of beams with recycled coarse aggregate concrete (RCAC), finite element models (FEMs) were developed to simulate 12 preloaded RCAC beams, strengthened with two CFRP strengthening schemes. Details of the modeling are provided including the material models, boundary conditions, applied loads, analysis solver, mesh analysis and computational efficiency.

Findings

Using FEM, a parametric study was carried out to assess the influence of CFRP thickness on the strengthening efficiency. The FEM provided results in good agreement with those from the experiments with differences and standard deviation not exceeding 11.1% and 3.1%, respectively. It was found that increasing the CFRP laminate thickness improved the load-carrying capacity of the strengthened beams.

Originality/value

The developed models simulate the preloading and loading up to failure with/without CFRP strengthening for the investigated beams. Moreover, the models were validated against the experimental results of 12 beams in terms of crack pattern as well as load, deflection and strain.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 19 July 2024

Sevar Dilkhaz Neamat, James H. Haido and George Wardeh

This study aims to address sustainability challenges in construction by exploring the structural performance and environmental benefits of incorporating pozzolanic waste glass…

15

Abstract

Purpose

This study aims to address sustainability challenges in construction by exploring the structural performance and environmental benefits of incorporating pozzolanic waste glass (WG) into ultra-high-performance reinforced concrete (UHPRC) beams.

Design/methodology/approach

A comprehensive evaluation of UHPRC beams was conducted, incorporating varying ratios (10%, 20% and 30%) of WG powder alongside a consistent 0.75% inclusion of basalt fiber. The investigation encompassed the entire UHPRC production process, including curing, casting and molding, while evaluating workability and physical properties. Furthermore, the environmental impact, particularly CO2 emissions associated with UHPRC mixture components, was also assessed. Type K thermocouples were employed to analyze temperature dynamics during fabrication, providing valuable insights.

Findings

The findings demonstrate positive implications for using pozzolanic WG as a cement substitute in UHPRC beams.

Originality/value

This research stands out for its unique focus on the combined effects of incorporating recycled pozzolanic glass waste on the structural performance and environmental footprint of UHPRC beams.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 18 September 2024

Trong Nghia-Nguyen, Le Thanh Cuong, Samir Khatir, Le Minh Hoang, Salisa Chaiyaput and Magd Abdel Wahab

Concrete gravity dams are important structures for flood control and hydraulic power generation, but they can be vulnerable to seismic activity due to ground movements that…

Abstract

Purpose

Concrete gravity dams are important structures for flood control and hydraulic power generation, but they can be vulnerable to seismic activity due to ground movements that trigger crack propagation.

Design/methodology/approach

To better understand the factors that affect the stability of concrete gravity dams against concrete fracture during earthquakes, a concrete plastic damage model has been utilized with two new expressions to simulate compressive and tensile damage variables.

Findings

The findings showed that the crack patterns were strongly influenced by the concrete’s strength. The simulation results led to the proposal of appropriate concrete properties aimed at minimizing damage. These findings, together with the proposed model, offer significant insights that can enhance the safety and stability of concrete gravity dam structures.

Originality/value

This study offers a comprehensive analysis of concrete behavior under varying grades and introduces simple and robust expressions for evaluating concrete parameters in plastic damage models. The versatility of these expressions enables accurate simulation of stress-strain curves for different grades, resulting in excellent agreement between model results and experimental findings. The simulation of the Koyna Dam case study demonstrates a similarity in crack patterns with previous simulations and field observations.

Details

Engineering Computations, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 22 August 2022

Long Liu and Songqiang Wan

To make full use of the tensile strength of near surface mounting (NSM) pasted carbon fiber reinforced plastics (CFRP) strips and further increase the flexural bearing capacity…

99

Abstract

Purpose

To make full use of the tensile strength of near surface mounting (NSM) pasted carbon fiber reinforced plastics (CFRP) strips and further increase the flexural bearing capacity and flexibility of reinforced concrete (RC) beams, a new composite reinforcement method using ultra-high performance concrete (UHPC) layer in the compression zone of RC beams is submitted based on embedding CFRP strips in the tension zone of RC beams. This paper aims to discuss the aforementioned points.

Design/methodology/approach

The experimental beam was simulated by ABAQUS, and compared with the experimental results, the validity of the finite element model was verified. On this basis, the reinforced RC beam is used as the control beam, and parameters such as the CFRP strip number, UHPC layer thickness, steel bar ratio and concrete strength are studied through the verified model. In addition, the numerical calculation results of yield strength, ultimate strength, failure deflection and flexibility are also given.

Findings

The flexural bearing capacity of RC beams supported by the new method is 132.3% higher than that of unreinforced beams, and 7.8% higher than that of RC beams supported only with CFRP strips. The deflection flexibility coefficient of the new reinforced RC beam is 8.06, which is higher than that of the unreinforced beam and the reinforced concrete beam with only CFRP strips embedded in the tension zone.

Originality/value

In this paper, a new reinforcement method is submitted, and the effects of various parameters on the ultimate bearing capacity and flexibility of reinforced RC beams are analyzed by the finite element numerical simulation. Finally, the effectiveness of the new method is verified by the analytical formula.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 20 December 2023

Akash Gupta and Manjeet Singh

This study aims to evaluate the failure behavior of glass fiber-reinforced epoxy (GFRE) laminate subjected to cyclic loading conditions. It involves experimental investigation and…

42

Abstract

Purpose

This study aims to evaluate the failure behavior of glass fiber-reinforced epoxy (GFRE) laminate subjected to cyclic loading conditions. It involves experimental investigation and statistical analysis using Weibull distribution to characterize the failure behavior of the GFRE composite laminate.

Design/methodology/approach

Fatigue tests were conducted using a tension–tension loading scheme at a frequency of 2 Hz and a loading ratio (R) of 0.1. The tests were performed at five different stress levels, corresponding to 50%–90% of the ultimate tensile strength (UTS). Failure behavior was assessed through cyclic stress-strain hysteresis plots, dynamic modulus behavior and scanning electron microscopy (SEM) analysis of fracture surfaces.

Findings

The study identified common modes of failure, including fiber pullouts, fiber breakage and matrix cracking. At low stress levels, fiber breakage, matrix cracking and fiber pullouts occurred due to high shear stresses at the fiber–matrix interface. Conversely, at high stress levels, fiber breakage and matrix cracking predominated. Higher stress levels led to larger stress-strain hysteresis loops, indicating increased energy dissipation during cyclic loading. High stress levels were associated with a more significant decrease in stiffness over time, implying a shorter fatigue life, while lower stress levels resulted in a gradual decline in stiffness, leading to extended fatigue life.

Originality/value

This study makes a valuable contribution to understanding fatigue behavior under tension–tension loading conditions, coupled with an in-depth analysis of the failure mechanism in GFRE composite laminate at different stress levels. The fatigue behavior is scrutinized through stress-strain hysteresis plots and dynamic modulus versus normalized cycles plots. Furthermore, the characterization of the failure mechanism is enhanced by using SEM imaging of fractured specimens. The Weibull distribution approach is used to obtain a reliable estimate of fatigue life.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 21 December 2023

Nagat Zalhaf, Mariam Ghazy, Metwali Abdelatty and Mohamed Hamed Zakaria

Even though it is widely used, reinforced concrete (RC) is susceptible to damage from various environmental factors. The hazard of a fire attack is particularly severe because it…

Abstract

Purpose

Even though it is widely used, reinforced concrete (RC) is susceptible to damage from various environmental factors. The hazard of a fire attack is particularly severe because it may cause the whole structure to collapse. Furthermore, repairing and strengthening existing structures with high-performance concrete (HPC) has become essential from both technical and financial points of view. In particular, studying the postfire behavior of HPC with normal strength concrete substrate requires experimental and numerical investigations. Accordingly, this study aims to numerically investigate the post-fire behavior of reinforced composite RC slabs.

Design/methodology/approach

Consequently, in this study, a numerical analysis was carried out to ascertain the flexural behavior of simply supported RC slabs strengthened with HPC and exposed to a particularly high temperature of 600°C for 2 h. This behavior was investigated and analyzed in the presence of a number of parameters, such as HPC types (fiber-reinforced, 0.5% steel, polypropylene fibers [PPF], hybrid fibers), strengthening side (tension or compression), strengthening layer thickness, slab thickness, boundary conditions, reinforcement ratio and yield strength of reinforcement.

Findings

The results showed that traction-separation and full-bond models can achieve accuracy compared with experimental results. Also, the fiber type significantly affects the postfire performance of RC slab strengthened with HPC, where the inclusion of hybrid fiber recorded the highest ultimate load. While adding PPF to HPC showed a rapid decrease in the load-deflection curve after reaching the ultimate load.

Originality/value

The proposed model accurately predicted the thermomechanical behavior of RC slabs strengthened with HPC after being exposed to the fire regarding load-deflection response, crack pattern and failure mode. Moreover, the considered independent parametric variables significantly affect the composite slabs’ behavior.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 10 July 2024

Xu Zhang, Kangjie Tang, Yingyu Wang and Dongying Dong

The purpose objective of this study is to identify the friction coefficient and friction effect in electromagnetic upsetting (EMU) high-speed forming process.

Abstract

Purpose

The purpose objective of this study is to identify the friction coefficient and friction effect in electromagnetic upsetting (EMU) high-speed forming process.

Design/methodology/approach

Based on numerical simulation and upsetting experiment of 2A10 aluminum alloy bar, the friction coefficient between contact surfaces is obtained by combining the fitting displacement distribution function and the electromagnetic-mechanical coupling numerical model, and the influence of friction effect is analyzed.

Findings

The maximum impact velocity and acceleration during EMU are 13.9 m/s and −3.3 × 106 m/s2, respectively, and the maximum strain rate is 7700 s−1. The functional distribution relationship between friction coefficient combination (FS, FD) and characteristic parameters [upper diameter (D1) and middle diameter (D2)] is established. The values of FS and FD are 0.1402 and 0.0931, respectively, and the maximum relative error is 2.39%. By analyzing the distribution of equivalent stress and strain, it is found that plastic deformation has obvious zoning characteristics and there is serious failure concentration in the strong shear zone.

Originality/value

Friction coefficient significantly affects stress or strain distributions in material forming process, but it is difficult to obtain friction coefficients through experimental tests in the high-speed forming process. In this paper, a multi-field coupling numerical model is proposed to determine friction coefficients and applied to the electromagnetic impact loading process (a high-speed forming process).

Peer review

The peer review history for this article is available at: https://publons.com/publon/10.1108/ILT-05-2024-0154/

Details

Industrial Lubrication and Tribology, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0036-8792

Keywords

Article
Publication date: 31 October 2022

Yasmeen Taleb Obaidat, Wasim Barham and Rawan Abu libdeh

The main aim of this study is to examine the behavior of reinforced concrete short columns strengthened using longitudinal near surface mounted (NSM)-carbon fiber reinforced…

Abstract

Purpose

The main aim of this study is to examine the behavior of reinforced concrete short columns strengthened using longitudinal near surface mounted (NSM)-carbon fiber reinforced polymer (CFRP) strips.

Design/methodology/approach

A full 3D-finite element (FE) model was developed using ABAQUS in order to conduct the analysis. The model is first validated based on experimental data available in the literature, and then the effect of concrete compressive strength, number of CFRP strips that are used and the spacing between them were taken in consideration for both concentric and eccentric loading cases. The parametric study specimens were divided into three groups. The first group consisted of unstrengthened columns and served as control specimens. The second group consisted of columns strengthened by longitudinal CFRP strips at two opposite column faces.

Findings

The results of this study are used to develop interaction diagrams for CFRP-strengthened short columns and to develop best-fit equations to estimate the nominal axial load and moment capacities for these strengthened columns. The results showed that the specimens that were strengthened using more longitudinal CFRP strips showed a significant increase in axial load capacity and a significant improvement in the interaction diagram, especially at large load eccentricity values. This result can be justified by the fact that longitudinal strips effectively resist the bending moment that is generated due to eccentric loading. Generally, the process of strengthening using longitudinal strips only has a reasonable effect and it can be typically considered an excellent choice considering the economic aspect when the budget of strengthening is limited.

Originality/value

This research aims at studying the performance of strengthened rectangular reinforced concrete short columns with CFRP strips using FE method, developing interaction diagrams of strengthened columns in order to investigate the effect of different parameters such as compressive strength (20, 30 and 40 MPa), number of CFRP strips (1, 2, 3 and 4) and the spacing between CFRP strips in terms of the ratio of CFRP center point distance to column outside dimension ratio (0.60, 0.70 and 0.80) on the behavior of strengthened RC columns and improving empirical formulas to predict the nominal axial load and moment capacities of strengthened RC columns. These parameters that directly affect short column load carrying capacity are presented in ACI-318 (2014).

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

1 – 10 of 38