Search results
1 – 5 of 5Laiming Yu, Yaqin Fu and Yubing Dong
The purpose of this study is to investigate the thermomechanical condition on the shape memory property of Polybutylene adipate-co-terephthalate (PBAT). PBAT is a widely…
Abstract
Purpose
The purpose of this study is to investigate the thermomechanical condition on the shape memory property of Polybutylene adipate-co-terephthalate (PBAT). PBAT is a widely researched and rapidly developed biodegradable copolyester. In a tensile test, we found that the fractured PBAT samples had a heat-driven shape memory effect which piqued our interest, and it will lay a foundation for the application of PBAT in new fields (such as heat shrinkable film).
Design/methodology/approach
The shape memory effect of PBAT and the effect of the thermomechanical condition on its shape memory property were confirmed and systematically investigated by a thermal mechanical analyzer and tensile machine.
Findings
The results showed that the PBAT film had broad shape memory transform temperature and exhibited excellent thermomechanical stability and shape memory properties. The shape memory fixity ratio (Rf) of the PBAT films was increased with the prestrain temperature and prestrain, where the highest Rf exceeded 90%. The shape memory recovery ratio (Rr) of the PBAT films was increased with the shape memory recovery temperature and decreased with the prestrain value, and the highest Rr was almost 100%. Moreover, the PBAT films had high shape memory recovery stress which increased with the prestrain value and decreased with the prestrain temperature, and the highest shape memory recovery stress can reach 7.73 MPa.
Research limitations/implications
The results showed that PBAT had a broad shape memory transform temperature, exhibited excellent thermomechanical stability and shape memory performance, especially for the sample programmed at high temperature and had a larger prestrian, which will provide a reference for the design, processing and application of PBAT-based heat shrinkable film and smart materials.
Originality/value
This study confirmed and systematically investigated the shape memory effect of PBAT and the effect of the thermomechanical condition on the shape memory property of PBAT.
Details
Keywords
Abhishek Barwar, Prateek Kala and Rupinder Singh
Some studies have been reported in the past on diaphragmatic hernia (DH) surgery techniques using additive manufacturing (AM) technologies, symptoms of a hernia and post-surgery…
Abstract
Purpose
Some studies have been reported in the past on diaphragmatic hernia (DH) surgery techniques using additive manufacturing (AM) technologies, symptoms of a hernia and post-surgery complications. But hitherto little has been reported on bibliographic analysis (BA) for health monitoring of bovine post-DH surgery for long-term management. Based on BA, this study aims to explore the sensor fabrication integrated with innovative AM technologies for health monitoring assistance of bovines post-DH surgery.
Design/methodology/approach
A BA based on the data extracted through the Web of Science database was performed using bibliometric tools (R-Studio and Biblioshiny).
Findings
After going through the BA and a case study, this review provides information on various 3D-printed meshes used over the sutured site and available Internet of Things-based solutions to prevent the recurrence of DH.
Originality/value
Research gaps exist for 3D-printed conformal sensors for health monitoring of bovine post-DH surgery.
Details
Keywords
Celia Rufo-Martín, Ramiro Mantecón, Geroge Youssef, Henar Miguelez and Jose Díaz-Álvarez
Polymethyl methacrylate (PMMA) is a remarkable biocompatible material for bone cement and regeneration. It is also considered 3D printable but requires in-depth…
Abstract
Purpose
Polymethyl methacrylate (PMMA) is a remarkable biocompatible material for bone cement and regeneration. It is also considered 3D printable but requires in-depth process–structure–properties studies. This study aims to elucidate the mechanistic effects of processing parameters and sterilization on PMMA-based implants.
Design/methodology/approach
The approach comprised manufacturing samples with different raster angle orientations to capitalize on the influence of the filament alignment with the loading direction. One sample set was sterilized using an autoclave, while another was kept as a reference. The samples underwent a comprehensive characterization regimen of mechanical tension, compression and flexural testing. Thermal and microscale mechanical properties were also analyzed to explore the extent of the appreciated modifications as a function of processing conditions.
Findings
Thermal and microscale mechanical properties remained almost unaltered, whereas the mesoscale mechanical behavior varied from the as-printed to the after-autoclaving specimens. Although the mechanical behavior reported a pronounced dependence on the printing orientation, sterilization had minimal effects on the properties of 3D printed PMMA structures. Nonetheless, notable changes in appearance were attributed, and heat reversed as a response to thermally driven conformational rearrangements of the molecules.
Originality/value
This research further deepens the viability of 3D printed PMMA for biomedical applications, contributing to the overall comprehension of the polymer and the thermal processes associated with its implementation in biomedical applications, including personalized implants.
Details
Keywords
Austin R. Colon, David Owen Kazmer, Amy M. Peterson and Jonathan E. Seppala
A main cause of defects within material extrusion (MatEx) additive manufacturing is the nonisothermal condition in the hot end, which causes inconsistent extrusion and polymer…
Abstract
Purpose
A main cause of defects within material extrusion (MatEx) additive manufacturing is the nonisothermal condition in the hot end, which causes inconsistent extrusion and polymer welding. This paper aims to validate a custom hot end design intended to heat the thermoplastic to form a melt prior to the nozzle and to reduce variability in melt temperature. A full 3D temperature verification methodology for hot ends is also presented.
Design/methodology/approach
Infrared (IR) thermography of steady-state extrusion for varying volumetric flow rates, hot end temperature setpoints and nozzle orifice diameters provides data for model validation. A finite-element model is used to predict the temperature of the extrudate. Model tuning demonstrates the effects of different model assumptions on the simulated melt temperature.
Findings
The experimental results show that the measured temperature and variance are functions of volumetric flow rate, temperature setpoint and the nozzle orifice diameter. Convection to the surrounding air is a primary heat transfer mechanism. The custom hot end brings the melt to its setpoint temperature prior to entering the nozzle.
Originality/value
This work provides a full set of steady-state IR thermography data for various parameter settings. It also provides insight into the performance of a custom hot end designed to improve the robustness of melting in MatEx. Finally, it proposes a strategy for modeling such systems that incorporates the metal components and the air around the system.
Details
Keywords
Senthil Kumar Selvaraj, Srimathy B., Sakthivel S. and Senthil Kumar B.
In the past decade, the biopolymeric properties of chitosan (CH) have been largely exploited for various applications. This paper aims to study the use of CH in its nanoform, i.e…
Abstract
Purpose
In the past decade, the biopolymeric properties of chitosan (CH) have been largely exploited for various applications. This paper aims to study the use of CH in its nanoform, i.e. as nanofibers blended with polyvinyl alcohol (PVA) for various antimicrobial applications in detail. In particular, their ability toward bacterial growth inhibition, in vitro drug release and their biocompatibility toward tissue growth have been investigated in detail.
Design/methodology/approach
Electrospinning technique was adapted for depositing CH/PVA blended nanofilms on the silver foil under optimized conditions of high voltage. Three different concentrations of blended nanofiber samples were prepared and their antimicrobial properties were studied.
Findings
The bead diameter and average diameter of blended nanofibers increase with CH concentration. Antibacterial activity increases as CH concentration increases. Increased hydrophilicity in CH-enriched samples contributes to a higher drug release profile.
Originality/value
To the best of the authors’ knowledge, chick chorioallantoic membrane assay analysis has been carried out for the first time for CH/PVA films which shows that CH/PVA blends are biocompatible. CH after being converted as nanoparticles exhibits higher drug release rate by in vitro method.
Details