Search results

1 – 10 of over 3000
Article
Publication date: 21 March 2008

Hemant K. Singh, Prashant M. Pawar, Ranjan Ganguli and Sung Nam Jung

This study aims to investigate the effects of mass and stiffness imbalance in a tail rotor induced by damage in forward flight.

Abstract

Purpose

This study aims to investigate the effects of mass and stiffness imbalance in a tail rotor induced by damage in forward flight.

Design/methodology/approach

An aeroelastic analysis based on finite element in space and time and capable of modeling dissimilar blades is carried out to study the effect of damage occurring in one, two, and three blades in a four‐bladed tail rotor system in forward flight. The effect of damage growth on vibratory hub loads and blade responses is studied using a comprehensive aeroelastic code.

Findings

The diagnostic chart which is the summary of damage analysis of tail rotor shows that the root hub vibration spectrum gives enough indication to predict damage growth in the tail rotor blade. Hence, this can be useful towards development of health monitoring system for tail rotor blades.

Originality/value

The proposed analysis helps in understanding the basic physics behind the damaged tail rotor and also gives qualitative assessment of damaged tail rotor where obtaining the flight test data with damaged tail rotor is difficult.

Details

Aircraft Engineering and Aerospace Technology, vol. 80 no. 2
Type: Research Article
ISSN: 0002-2667

Keywords

Article
Publication date: 11 April 2016

Andreas Zegowitz, Anna Renzl, Wolfgang Hofbauer, Joerg Meyer and Hartwig Kuenzel

The water damage in buildings because of leaking pipes and increasingly because of floods and severe weather require professional help. Methods for improved repair and remediation…

Abstract

Purpose

The water damage in buildings because of leaking pipes and increasingly because of floods and severe weather require professional help. Methods for improved repair and remediation techniques have to be developed. The water damage in buildings because of leaking pipes and increasingly because of floods and severe weather require professional help. Methods for improved repair and remediation techniques have to be developed. The paper aims to discuss these issues.

Design/methodology/approach

Therefore, large scale laboratory tests with four rooms, each with three types of masonry walls (Figure 2 and Plate 1) and typical floors for intermediate storeys with insulation were performed within a climate simulator. Artificial water damage was provoked through watering the floors, and the dispersion of water in the floors and the rising damp in the walls was measured. In the follow-up to the watering of the floors, a company specialized in drying wet buildings, installed systems for under floor drying and wall drying.

Findings

The drying process of the different components and layers of the floor construction and walls was monitored by a measuring system with more than 300 sensors for moisture content, relative humidity and temperature accompanied by thermography and demonstrated so the advantages and disadvantages of the different tested drying systems. After providing an initial contamination that is typical for construction sites, the microbial load (mould infestation) within the wet components was monitored at different times by experienced biologists. So after three weeks under floor drying no mould growth could be asserted but more bacteria than expected were found.

Originality/value

The aim of the research was to gain more confidence in selecting appropriate drying procedures and systems in order to identify the right moment for terminating the drying process. A further intent was to acquire data for computer simulations.

Details

Structural Survey, vol. 34 no. 1
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 4 November 2014

Simon Tucker, Eshrar Latif and Devapriya C. Wijeyesekera

The purpose of this paper is to describe and discuss initial work to assess the moisture buffering performance of selected bio-insulations in lofts that suffer from excessive…

Abstract

Purpose

The purpose of this paper is to describe and discuss initial work to assess the moisture buffering performance of selected bio-insulations in lofts that suffer from excessive moisture following refurbishment.

Design/methodology/approach

These conditions were then reproduced in a physical lab-based experiment such that the comparative performance of the bio-insulations and stone wool could be measured.

Findings

It was found that the bio-insulations could remove over 60 per cent of the moisture in the loft air, and therefore reduce the risk of condensation and its severity.

Research limitations/implications

The initial work reported here is indicative of the buffering potential of bio-insulations but further work is required to better quantify this performance. There is a need to further examine lofts with moisture problems and to produce reliable testing methods and protocols to be used when retrofitting loft insulation.

Practical implications

Installers and specifiers of loft insulation should ensure that insulation is installed correctly, as with the drive to increase loft insulation levels the risks of damaging the building fabric through condensation are increasing.

Social implications

Excessive moisture can damage the building fabric and create health problems. Using insulations that perform well across a range of performance criteria tend to favour bio-insulations, which have a far less harmful impact on the environment than do typical fossil-fuel based insulations.

Originality/value

The paper presents preliminary findings that support arguments for specifying bio-insulations.

Details

Structural Survey, vol. 32 no. 5
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 10 February 2022

Lokesh Gupta and Rakesh Kumar

Natural good-quality sources of aggregates are depleting, whereas large amount of reclaimed asphalt pavement (RAP) is produced annually. Safe disposal and use of RAP in the cold…

Abstract

Purpose

Natural good-quality sources of aggregates are depleting, whereas large amount of reclaimed asphalt pavement (RAP) is produced annually. Safe disposal and use of RAP in the cold in-place recycling (CIR) using foamed bitumen could be sustainable approach where milling and mixing operations are accomplished simultaneously. This will not only help in minimizing contamination (probability) and transportation cost but also reduces the carbon footprints. Therefore, this study aims to investigate the scope of RAP utilization up to 100% and further its effect on the behavior of reclaimed asphalt foamed bituminous mix.

Design/methodology/approach

Reclaimed asphalt foamed bituminous mix (FBM) is still a new technique. The evidence of performance of 100% recycled pavement (CIR) is only anecdotal and lacks in systematic guidelines and literatures. Foam binder coating around the aggregates is also a concern. Therefore, this study is mainly emphasized to investigate the scope of RAP use in the FBM up to 100%. RAP content is varied in each trial, i.e. 70, 85, 100 and 0% (only fresh aggregates), to make the FBM. RAP use and its effect on the behavior of FBM in terms of resilient modulus, variation in resilient modulus with curing, rutting performance and the potential of resistance against the moisture damage are addressed.

Findings

Considering the laboratory studies, it can be accomplished that mechanistic properties and performance of FBM are largely influenced by RAP material and portray less susceptible characteristics against the moisture damage. FBM containing 70% RAP content exhibits maximum resilient modulus. However, use of RAP up to 100% in FBM is satisfying the minimum required specification.

Originality/value

Overall, the study may be helpful to highway professionals and could generate another possible option of 100% RAP replacing fresh aggregates in the flexible pavements.

Details

World Journal of Engineering, vol. 20 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Open Access
Article
Publication date: 25 November 2019

Ulrika Uotila, Arto Saari and Juha-Matti Junnonen

This study aims to present property management challenges that municipalities have encountered regarding a public building with noted building-related symptoms. The study goes on…

1355

Abstract

Purpose

This study aims to present property management challenges that municipalities have encountered regarding a public building with noted building-related symptoms. The study goes on to provide reasons for the failure of attempts to manage the symptoms and discusses the current challenges concerning the process.

Design/methodology/approach

A participatory case study was used as the research methodology to identify the current challenges concerning a municipal approach to managing the building-related symptoms in a case-study building. The researchers scrutinised the history of the health symptom management process and attended the project planning meetings focused on the investigation of the condition of the building.

Findings

Multiple challenges concerning maintenance and omitted or postponed repair actions, as well as vagueness in the management process were found. In addition to this, it was noted that the complexity of the initial design of the building and vandalism have resulted in challenges for the maintenance and moisture performance of the building structures. According to the study, more orderliness and a more systematic process is needed when managing a municipal property.

Practical implications

The identified property management challenges may be of practical value for the facility managers and the property owners, especially when managing the building-related symptoms and a damaged building.

Originality/value

This study highlights the importance of having an in-depth understanding of condition assessments as well as proper maintenance and timely repairs for the successful management of the building-related symptoms in a municipal building. This is a pilot project in a larger project of management of building refurbishment.

Details

Facilities , vol. 38 no. 5/6
Type: Research Article
ISSN: 0263-2772

Keywords

Article
Publication date: 1 June 1998

James Douglas

Continues to examine the provision of damp proofing in ground floors. Shows that damp proof membranes only became mandatory in floors laid after the mid‐1960s. Examines the…

1055

Abstract

Continues to examine the provision of damp proofing in ground floors. Shows that damp proof membranes only became mandatory in floors laid after the mid‐1960s. Examines the methods and location of damp proofing in ground floors. Considers the problems associated with dampness in, and damp proofing of, ground floors.

Details

Structural Survey, vol. 16 no. 2
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 4 November 2013

Birgit Risholt, Elisabeth Waernes, Berit Time and Anne Grete Hestnes

The purpose of this paper is to gain knowledge on the renovation status for Norwegian dwellings that can be used to design attractive energy efficiency measures. Norwegian…

Abstract

Purpose

The purpose of this paper is to gain knowledge on the renovation status for Norwegian dwellings that can be used to design attractive energy efficiency measures. Norwegian dwellings are exposed to a windy, cold and moist climate and the technical condition of existing dwellings depend on the owners priorities regarding maintenance and renovation. The paper focuses on the renovation status and technical condition of privately owned detached houses built in Norway in the 1980s constituting 10 per cent of the total Norwegian dwelling stock. These houses are high-energy spenders and are at a stage in their lifetime where major renovation such as new windows and ventilation system is expected.

Design/methodology/approach

The status for redecoration, maintenance and renovation as well as the technical condition of 91 dwellings are mapped and analysed.

Findings

An analysis of the empirical data identified four categories of houses when considering home upgrades and technical condition: the as built, the aesthetic, the well kept and the do it yourselves houses. There is no correlation between the observed technical condition and the home upgrade level for the houses in the study. Significant resources may have been used for redecoration and unskilled renovation while not dealing with the need for maintenance and repair.

Research limitations/implications

The knowledge on homeowner categories can be used to tailor policy instruments to accelerate energy efficiency rates for privately owned dwellings.

Originality/value

There are no previous studies on Norwegian private homeowners and the technical condition of their homes.

Details

Structural Survey, vol. 31 no. 5
Type: Research Article
ISSN: 0263-080X

Keywords

Open Access
Article
Publication date: 5 August 2021

Ulrika Uotila, Arto Saari, Juha-Matti Kalevi Junnonen and Lari Eskola

Poor indoor air quality in schools is a worldwide challenge that poses health risks to pupils and teachers. A possible response to this problem is to modify ventilation…

3036

Abstract

Purpose

Poor indoor air quality in schools is a worldwide challenge that poses health risks to pupils and teachers. A possible response to this problem is to modify ventilation. Therefore, the purpose of this paper is to pilot a process of generating alternatives for ventilation redesign, in an early project phase, for a school to be refurbished. Here, severe problems in indoor air quality have been found in the school.

Design/methodology/approach

Ventilation redesign is investigated in a case study of a school, in which four alternative ventilation strategies are generated and evaluated. The analysis is mainly based on the data gathered from project meetings, site visits and the documents provided by ventilation and condition assessment consultants.

Findings

Four potential strategies to redesign ventilation in the case school are provided for decision-making in refurbishment in the early project phase. Moreover, the research presents several features to be considered when planning the ventilation strategy of an existing school, including the risk of alterations in air pressure through structures; the target number of pupils in classrooms; implementing and operating costs; and the size of the space that ventilation equipment requires.

Research limitations/implications

As this study focusses on the early project phase, it provides viewpoints to assist decision-making, but the final decision requires still more accurate calculations and simulations.

Originality/value

This study demonstrates the decision-making process of ventilation redesign of a school with indoor air problems and provides a set of features to be considered. Hence, it may be beneficial for building owners and municipal authorities who are engaged in planning a refurbishment of an existing building.

Details

Facilities , vol. 40 no. 15/16
Type: Research Article
ISSN: 0263-2772

Keywords

Article
Publication date: 7 January 2022

Bahirathan Koneswaran, Chandana Siriwardana and Ravindu Udayantha Jayasekara

The government-led public healthcare services in Sri Lanka became a major strength in managing the COVID-19 comparatively well. However, natural hazards are a major threat to this…

Abstract

Purpose

The government-led public healthcare services in Sri Lanka became a major strength in managing the COVID-19 comparatively well. However, natural hazards are a major threat to this healthcare system, as they cause severe damages, especially to curative healthcare infrastructures such as hospitals. Floods have been the major contributor to the economic loss of the Sri Lankan healthcare system. Therefore, the purpose of this study is to develop a proper flood risk assessment framework for Sri Lankan hospitals.

Design/methodology/approach

This research study has attempted to develop a flood vulnerability assessment tool for hospitals using the concept of Depth Damage Functions (DDFs). Flood vulnerability curves have been developed for identified critical units of hospitals considering the damage caused to building contents which are predominantly expensive medical equipment. The damage caused only by wetting was considered in generating vulnerability curves. Structured interviews were conducted with government officials in the healthcare sector to gather details on the cost and damages of medical equipment. Pilot studies were carried out in two hospitals identified as located in flood-prone areas and have previous experiences of flooding, to acquire data regarding building contents of the critical units.

Findings

The developed vulnerability curves indicate that no major damage would occur to building contents in critical units (other than the labor room) until the inundation depth reaches a value of 0.6–0.9 m (varies for each type of unit). It is also noteworthy that after a certain range in the inundation depth, the damage increases drastically, and building contents would incur total damage if the inundation depth passes a value of 1.2–1.5 m.

Originality/value

This study explains the initial phase of developing a flood vulnerability assessment framework for Sri Lankan hospitals. Not many studies had been carried out to assess the vulnerability of hospitals specifically for floods using vulnerability curves. The study recommends a zoning system with pre-defined vulnerability levels for critical units during a flood, which can be associated with evacuation planning as well. Further studies must be carried out to verify this system for hospitals in Sri Lanka.

Details

International Journal of Disaster Resilience in the Built Environment, vol. 13 no. 1
Type: Research Article
ISSN: 1759-5908

Keywords

Article
Publication date: 13 April 2015

Elton Bauer, Vasco Peixoto de Freitas, Niubis Mustelier, Eva Barreira and Sara Stingl de Freitas

Infrared thermography is increasingly being used to diagnose pathologies in buildings, such as façade defects. The purpose of this paper is to assess the results reproducibility…

Abstract

Purpose

Infrared thermography is increasingly being used to diagnose pathologies in buildings, such as façade defects. The purpose of this paper is to assess the results reproducibility and the equipment influence on the measurements. To do so, it was defined as case study the assessment of rendering delamination.

Design/methodology/approach

Two infrared cameras of different makers were used to detect the presence of defects deliberately created in specimens. The tests were done in the laboratory with a heat source. The defects were detected through a temperature gradient between the zones with and without defect.

Findings

With this thermographic imaging, it was possible to identify the defects in the specimen both qualitatively and quantitatively. The results were found to be reproducible in the three cycles performed. The influence of the equipment on the results was of little significance for the quantitative assessment criterion “temperature difference between zones with and without defect”, but for the criterion “absolute surface temperature”, the difference in the results yielded by the two cameras was around 1.8°C.

Originality/value

The results suggest that there is reproducibility of the measurements, considering both the qualitative and quantitative approach, when assessing delamination, irrespective of the maker of the equipment used. The influence of the equipment on the results depends on the quantitative assessment criterion used.

Details

Structural Survey, vol. 33 no. 1
Type: Research Article
ISSN: 0263-080X

Keywords

1 – 10 of over 3000