1 – 2 of 2Piotr Walter, Andrzej Pepłowski, Łukasz Górski, Daniel Janczak and Małgorzata Jakubowska
Because of the bioaccumulation effect, organophosphorus pesticides cause long-term damage to mammals, even at small concentrations. The ability to perturb the phospholipid bilayer…
Abstract
Purpose
Because of the bioaccumulation effect, organophosphorus pesticides cause long-term damage to mammals, even at small concentrations. The ability to perturb the phospholipid bilayer structure as well as the overstimulation of cholinergic receptors makes them hazardous to humans. Therefore, there is a need for a quick and inexpensive detection of organophosphorus pesticides for agricultural and household use. As organophosphorus pesticides are acetylcholinesterase (AChE) inhibitors, biosensors using this mechanism hold a great promise to meet these requirements with a fraction of reagents and time used for measurement comparing to laboratory methods. This study aims to manufacture AChE-coated, screen-printed carbon electrodes applicable in such amperometric biosensors.
Design/methodology/approach
AChE enzyme, known for catalytic activity for the hydrolysis of acetylthiocholine (ATCh), could be used to obtain electrochemically active thiocholine from acetylthiocholine chloride in aqueous solutions. Using Malathion’s inhibitory effect towards AChE, pesticides’ presence can be detected by reduction of anodic oxidation peaks of thiocholine in cyclic voltammetry.
Findings
The conducted research proved that it is possible to detect pesticides using low-cost, simple-to-manufacture screen-printed graphite (GR) electrodes with an enzymatic (AChE) coating. Investigated electrodes displayed significant catalytic activity to the hydrolysis of ATCh. Owing to inhibition effect of the enzyme, amperometric response of the samples decreased in pesticide-spiked solution, allowing determination of organophosphorus pesticides.
Originality/value
Printed electronics has grown significantly in recent years as well as research focused on carbon-based nanocomposites. Yet, the utilization of carbon nanocomposites in screen-printed electronics is still considered a novelty in the market. Biosensors have proved useful not only in laboratory conditions but also in home applications, as glucometers are a superior solution for glucose determination for personal use. Although pesticides could be detected accurately using chromatography, spectroscopy, spectrometry or spectrophotometry, the market lacks low-cost, disposable solutions for pesticide detection applicable for household use. With biosensing techniques and electric paths screen-printed with GR or graphene nanocomposites, this preliminary research focuses on meeting these needs.
Details
Keywords
Andrzej Peplowski, Daniel Janczak, Grzegorz Wróblewski, Marcin Słoma, Łukasz Górski, Elżbieta Malinowska, Tadeusz Pałko and Małgorzata Jakubowska
– The aim of this paper was to verify applicability of graphene-based sensors for voltammetric and amperometric measurements of low-concentration compounds in biological fluids.
Abstract
Purpose
The aim of this paper was to verify applicability of graphene-based sensors for voltammetric and amperometric measurements of low-concentration compounds in biological fluids.
Design/methodology/approach
Using the screen printing method, electrochemical sensors were manufactured on polymethylmetacrylate foil using a paste consisting of organic solvents and graphene nanopetals. As the model of a biological fluid tear film was chosen, the compound chosen as the analyte was H2O2, which is produced in oxidation of biological compounds. Tear film analog was prepared, in which, the measurements were carried out in a wide range of concentrations to determine the oxidation potential of H2O2 through square-wave voltammetry. The second series of amperometric measurements was carried out for concentrations between 0 and 30 μM/L, which is the lower range of physiological glucose concentration in tear films.
Findings
The sensors presented linearity for concentrations from 0 to 3.5 per cent. Mean linear correlation coefficient between the peak current and the concentration for the examined sensors was 0.9764. Mean sensitivity was 434.4 mA·M−1·L−1.
Research limitations/implications
Results indicate a need for optimization of the sensors ' performance. Main parameters to be improved are surface area of electrodes and purity of the graphene layer, as well as uniformity of the manufacturing process to improve accuracy and repeatability of measurements.
Practical implications
Technology and materials used present an opportunity for creating low-cost, miniaturized and biocompatible sensors to be used in medical monitoring.