Search results

1 – 7 of 7
Article
Publication date: 29 February 2024

Heng Liu, Yonghua Lu, Haibo Yang, Lihua Zhou and Qiang Feng

In the context of fixed-wing aircraft wing assembly, there is a need for a rapid and precise measurement technique to determine the center distance between two double-hole…

Abstract

Purpose

In the context of fixed-wing aircraft wing assembly, there is a need for a rapid and precise measurement technique to determine the center distance between two double-hole components. This paper aims to propose an optical-based spatial point distance measurement technique using the spatial triangulation method. The purpose of this paper is to design a specialized measurement system, specifically a spherically mounted retroreflector nest (SMR nest), equipped with two laser displacement sensors and a rotary encoder as the core to achieve accurate distance measurements between the double holes.

Design/methodology/approach

To develop an efficient and accurate measurement system, the paper uses a combination of laser displacement sensors and a rotary encoder within the SMR nest. The system is designed, implemented and tested to meet the requirements of precise distance measurement. Software and hardware components have been developed and integrated for validation.

Findings

The optical-based distance measurement system achieves high precision at 0.04 mm and repeatability at 0.02 mm within a range of 412.084 mm to 1,590.591 mm. These results validate its suitability for efficient assembly processes, eliminating repetitive errors in aircraft wing assembly.

Originality/value

This paper proposes an optical-based spatial point distance measurement technique, as well as a unique design of a SMR nest and the introduction of two novel calibration techniques, all of which are validated by the developed software and hardware platform.

Details

Sensor Review, vol. 44 no. 2
Type: Research Article
ISSN: 0260-2288

Keywords

Content available
Article
Publication date: 13 September 2011

415

Abstract

Details

Sensor Review, vol. 31 no. 4
Type: Research Article
ISSN: 0260-2288

Article
Publication date: 25 January 2024

Siming Cao, Hongfeng Wang, Yingjie Guo, Weidong Zhu and Yinglin Ke

In a dual-robot system, the relative position error is a superposition of errors from each mono-robot, resulting in deteriorated coordination accuracy. This study aims to enhance…

Abstract

Purpose

In a dual-robot system, the relative position error is a superposition of errors from each mono-robot, resulting in deteriorated coordination accuracy. This study aims to enhance relative accuracy of the dual-robot system through direct compensation of relative errors. To achieve this, a novel calibration-driven transfer learning method is proposed for relative error prediction in dual-robot systems.

Design/methodology/approach

A novel local product of exponential (POE) model with minimal parameters is proposed for error modeling. And a two-step method is presented to identify both geometric and nongeometric parameters for the mono-robots. Using the identified parameters, two calibrated models are established and combined as one dual-robot model, generating error data between the nominal and calibrated models’ outputs. Subsequently, the calibration-driven transfer, involving pretraining a neural network with sufficient generated error data and fine-tuning with a small measured data set, is introduced, enabling knowledge transfer and thereby obtaining a high-precision relative error predictor.

Findings

Experimental validation is conducted, and the results demonstrate that the proposed method has reduced the maximum and average relative errors by 45.1% and 30.6% compared with the calibrated model, yielding the values of 0.594 mm and 0.255 mm, respectively.

Originality/value

First, the proposed calibration-driven transfer method innovatively adopts the calibrated model as a data generator to address the issue of real data scarcity. It achieves high-accuracy relative error prediction with only a small measured data set, significantly enhancing error compensation efficiency. Second, the proposed local POE model achieves model minimality without the need for complex redundant parameter partitioning operations, ensuring stability and robustness in parameter identification.

Details

Industrial Robot: the international journal of robotics research and application, vol. 51 no. 2
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 12 September 2023

Ling Wang, Xiaoliang Wu, Zeng Kang, Yanfeng Gao, Xiai Chen and Binrui Wang

In traditional calibration methods of kinematics parameters of industrial robots, dozens of model parameters are identified together based on an optimization procedure. Due to…

Abstract

Purpose

In traditional calibration methods of kinematics parameters of industrial robots, dozens of model parameters are identified together based on an optimization procedure. Due to different contributions of model parameter errors to the tool center point positioning error of industrial robots, obtaining good results for all model parameters is very difficult. Therefore, the purpose of this paper is to propose a sequential calibration method specifically for transmission ratio parameters, which includes reduction ratios and coupling ratios of industrial robot joints.

Design/methodology/approach

The ABB IRB 1410 industrial robot is considered as an example in this study. The transmission ratios for each joint of the robot are identified using the spatial circle fitting method based on spatial vectors, which fit the center and radius of joint rotation with the least squares optimization algorithm. In addition, a method based on the Rodrigues’ formula is designed and presented for identifying the actual coupling ratio of the robot. Subsequently, an experiment is carried out to verify the proposed sequential calibration method of transmission ratios.

Findings

In this experiment, the actual positions of the linkages before and after joint rotations are measured by a laser tracker. Accurate results of the reduction ratios and the coupling ratios are calculated, and the results are verified experimentally. The results show that by calibrating the reduction ratios and coupling ratios of the ABB robot, the rotation angle errors of the robot joints can be reduced.

Originality/value

The authors propose a sequential calibration method for transmission ratio parameters, including reduction ratios and coupling ratios of industrial robot joints. An experiment is carried out to verify this proposed sequential calibration method. This study may be beneficial for calibrating the kinematic parameters of industrial robots and improving their positioning accuracy.

Details

Industrial Robot: the international journal of robotics research and application, vol. 50 no. 6
Type: Research Article
ISSN: 0143-991X

Keywords

Open Access
Article
Publication date: 13 April 2022

Shuanggao Li, Zhichao Huang, Qi Zeng and Xiang Huang

Aircraft assembly is the crucial part of aircraft manufacturing, and to meet the high-precision and high-efficiency requirements, cooperative measurement consisting of multiple…

Abstract

Purpose

Aircraft assembly is the crucial part of aircraft manufacturing, and to meet the high-precision and high-efficiency requirements, cooperative measurement consisting of multiple measurement instruments and automatic assisted devices is being adopted. To achieve the complete data of all assembly features, measurement devices need to be placed at different positions, and the flexible and efficient transfer relies on Automated Guided Vehicles (AGVs) and robots in the large-size space and close range. This paper aims to improve the automatic station transfer in accuracy and flexibility.

Design/methodology/approach

A transferring system with Light Detection and Ranging (LiDAR) and markers is established. The map coupling for navigation is optimized. Markers are distributed according to the accumulated uncertainties. The path planning method applied to the collaborative measurement is proposed for better accuracy. The motion planning method is optimized for better positioning accuracy.

Findings

A transferring system is constructed and the system is verified in the laboratory. Experimental results show that the proposed system effectively improves positioning accuracy and efficiency, which improves the station transfer for the cooperative measurement.

Originality/value

A Transferring system for collaborative measurement is proposed. The optimized navigation method extends the application of visual markers. With this system, AGV is capable of the cooperative measurement of large aircraft structural parts.

Details

Journal of Intelligent Manufacturing and Special Equipment, vol. 3 no. 1
Type: Research Article
ISSN: 2633-6596

Keywords

Article
Publication date: 19 January 2015

Ahmed Joubair, Long Fei Zhao, Pascal Bigras and Ilian Bonev

The purpose of this paper is to describe a calibration method developed to improve the accuracy of a six degrees-of-freedom medical robot. The proposed calibration approach aims…

1082

Abstract

Purpose

The purpose of this paper is to describe a calibration method developed to improve the accuracy of a six degrees-of-freedom medical robot. The proposed calibration approach aims to enhance the robot’s accuracy in a specific target workspace. A comparison of five observability indices is also done to choose the most appropriate calibration robot configurations.

Design/methodology/approach

The calibration method is based on the forward kinematic approach, which uses a nonlinear optimization model. The used experimental data are 84 end-effector positions, which are measured using a laser tracker. The calibration configurations are chosen through an observability analysis, while the validation after calibration is carried out in 336 positions within the target workspace.

Findings

Simulations allowed finding the most appropriate observability index for choosing the optimal calibration configurations. They also showed the ability of our calibration model to identify most of the considered robot’s parameters, despite measurement errors. Experimental tests confirmed the simulation findings and showed that the robot’s mean position error is reduced from 3.992 mm before calibration to 0.387 mm after, and the maximum error is reduced from 5.957 to 0.851 mm.

Originality/value

This paper presents a calibration method which makes it possible to accurately identify the kinematic errors for a novel medical robot. In addition, this paper presents a comparison between the five observability indices proposed in the literature. The proposed method might be applied to any industrial or medical robot similar to the robot studied in this paper.

Details

Industrial Robot: An International Journal, vol. 42 no. 1
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 1 March 2019

Samir Mekid and Salem Bashmal

Novel nanomaterials and nano-devices require further functional aspects that can be designed and supported using new nanomanipulation techniques allowing specific functions at the…

Abstract

Purpose

Novel nanomaterials and nano-devices require further functional aspects that can be designed and supported using new nanomanipulation techniques allowing specific functions at the design phase. The nano-manipulator becomes a key instrument for technology bridging sub-nano to mesoscale. The integration of various operations in nano-devices requires sub-nanometer precision and highly stable manipulator. This paper aims to review various design concepts of recent nanomanipulators, their motion characteristics, basic functions, imagine and automation with control techniques for the sake of establishing new design features based on recent requirements.

Design/methodology/approach

The paper reviews various existing nanomanipulators, their motion characteristics, basic functions, imagine and automation with control techniques. This will support precision machine design methodology and robotics principles.

Findings

The availability of a nano-precision instrument with integrated functions has proved to be extremely helpful in addressing various fundamental problems in science and engineering such as exploring, understanding, modeling and testing nano-machining process; exact construction of nano-structure arrays; and inspection of devices with complex features.

Originality/value

New functional specifications have emerged from this review to support the design and make of new advanced nanomanipulators with more features availability to support manipulation within the same reference datum needed for research and education.

Details

Journal of Engineering, Design and Technology, vol. 17 no. 3
Type: Research Article
ISSN: 1726-0531

Keywords