Search results

1 – 10 of 95
Article
Publication date: 6 February 2024

Ayodeji Emmanuel Oke, John Aliu, Doyin Helen Agbaje, Andrew Ebekozien, Douglas Omoregie Aghimien, Feyisetan Leo-Olagbaye and Clinton Aigbavboa

The purpose of this study is to identify and evaluate the primary constraints that quantity surveying firms in Nigeria encounter while integrating indoor environmental quality…

Abstract

Purpose

The purpose of this study is to identify and evaluate the primary constraints that quantity surveying firms in Nigeria encounter while integrating indoor environmental quality (IEQ) principles into building designs.

Design/methodology/approach

The study used a quantitative approach by administering a well-structured questionnaire to 114 quantity surveyors. The collected data were analyzed using methods such as frequencies, percentages, mean item scores, Kruskal–Wallis test and exploratory factor analysis.

Findings

The top five ranked constraints were limited access to funding or financing options, limited availability of green materials, limited availability of insurance for sustainable buildings, limited availability of sustainable design resources and limited diversity and inclusivity within the design profession. Based on the factor analysis, the study identified six clusters of constraints: structural-related constraints, technical-related constraints, financial-related constraints, capacity-related constraints, legal-related constraints and culture-related constraints.

Practical implications

This study has several practical implications for quantity surveying firms, policymakers and industry stakeholders involved in building design and construction in Nigeria. The findings of this study can also inform future research on the integration of IEQ principles into building designs.

Originality/value

By identifying and structuring the clusters of constraints faced by quantity surveying firms in Nigeria when implementing IEQ principles, this study provides a novel approach to understanding the challenges associated with IEQ implementation in the building sector. This understanding can guide policymakers, industry stakeholders and quantity surveying firms in developing effective strategies to overcome these constraints and promote IEQ principles in building design and construction.

Details

Construction Innovation , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 5 April 2024

Fateme Akhlaghinezhad, Amir Tabadkani, Hadi Bagheri Sabzevar, Nastaran Seyed Shafavi and Arman Nikkhah Dehnavi

Occupant behavior can lead to considerable uncertainties in thermal comfort and air quality within buildings. To tackle this challenge, the use of probabilistic controls to…

Abstract

Purpose

Occupant behavior can lead to considerable uncertainties in thermal comfort and air quality within buildings. To tackle this challenge, the use of probabilistic controls to simulate occupant behavior has emerged as a potential solution. This study seeks to analyze the performance of free-running households by examining adaptive thermal comfort and CO2 concentration, both crucial variables in indoor air quality. The investigation of indoor environment dynamics caused by the occupants' behavior, especially after the COVID-19 pandemic, became increasingly important. Specifically, it investigates 13 distinct window and shading control strategies in courtyard houses to identify the factors that prompt occupants to interact with shading and windows and determine which control approach effectively minimizes the performance gap.

Design/methodology/approach

This paper compares commonly used deterministic and probabilistic control functions and their effects on occupant comfort and indoor air quality in four zones surrounding a courtyard. The zones are differentiated by windows facing the courtyard. The study utilizes the energy management system (EMS) functionality of EnergyPlus within an algorithmic interface called Ladybug Tools. By modifying geometrical dimensions, orientation, window-to-wall ratio (WWR) and window operable fraction, a total of 465 cases are analyzed to identify effective control scenarios. According to the literature, these factors were selected because of their potential significant impact on occupants’ thermal comfort and indoor air quality, in addition to the natural ventilation flow rate. Additionally, the Random Forest algorithm is employed to estimate the individual impact of each control scenario on indoor thermal comfort and air quality metrics, including operative temperature and CO2 concentration.

Findings

The findings of the study confirmed that both deterministic and probabilistic window control algorithms were effective in reducing thermal discomfort hours, with reductions of 56.7 and 41.1%, respectively. Deterministic shading controls resulted in a reduction of 18.5%. Implementing the window control strategies led to a significant decrease of 87.8% in indoor CO2 concentration. The sensitivity analysis revealed that outdoor temperature exhibited the strongest positive correlation with indoor operative temperature while showing a negative correlation with indoor CO2 concentration. Furthermore, zone orientation and length were identified as the most influential design variables in achieving the desired performance outcomes.

Research limitations/implications

It’s important to acknowledge the limitations of this study. Firstly, the potential impact of air circulation through the central zone was not considered. Secondly, the investigated control scenarios may have different impacts on air-conditioned buildings, especially when considering energy consumption. Thirdly, the study heavily relied on simulation tools and algorithms, which may limit its real-world applicability. The accuracy of the simulations depends on the quality of the input data and the assumptions made in the models. Fourthly, the case study is hypothetical in nature to be able to compare different control scenarios and their implications. Lastly, the comparative analysis was limited to a specific climate, which may restrict the generalizability of the findings in different climates.

Originality/value

Occupant behavior represents a significant source of uncertainty, particularly during the early stages of design. This study aims to offer a comparative analysis of various deterministic and probabilistic control scenarios that are based on occupant behavior. The study evaluates the effectiveness and validity of these proposed control scenarios, providing valuable insights for design decision-making.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 16 April 2024

Fathima Sabrina Nazeer, Imriyas Kamardeen and Abid Hasan

Many buildings fail to meet user expectations, causing a performance gap. Pre-occupancy evaluation (PrOE) is believed to have the potential to close the gap. It enables designers…

Abstract

Purpose

Many buildings fail to meet user expectations, causing a performance gap. Pre-occupancy evaluation (PrOE) is believed to have the potential to close the gap. It enables designers to obtain end-user feedback in the design phase and improve the design for better performance. However, PrOE implementation faces challenges due to still maturing knowledgebase. This study aims to understand the state-of-the-art knowledge of PrOE, thereby identifying future research needs to advance the domain.

Design/methodology/approach

A systematic literature review following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) framework was conducted. A thorough search in five databases and Google Scholar retrieved 90 articles, with 30 selected for systematic review after eliminating duplicates and irrelevant articles. Bibliometric analyses were performed using VOSviewer and Biblioshiny on the article metadata, and thematic analyses were conducted on their contents.

Findings

PrOE is a vehicle for engaging building end-users in the design phase to address the credibility gap caused by the discrepancies between the expected and actual performance of buildings. PrOE has gained limited applications in healthcare, residential, office and educational building design for two broad purposes: design management and marketing. Using virtual reality technologies for PrOE has demonstrated significant benefits. Yet, the PrOE domain needs to mature in multiple perspectives to serve its intended purpose effectively.

Originality/value

This study identifies four knowledge gaps for future research to advance the PrOE domain: (1) developing a holistic PrOE framework, integrating comprehensive performance evaluation criteria, useable at different stages of the design phase and multi-criteria decision algorithms, (2) developing a mixed reality tool, embodying the holistic PrOE framework, (3) formulating a PrOE framework for adaptive reuse of buildings and (4) managing uncertainties in user requirements during the lifecycle in PrOE decisions.

Details

Built Environment Project and Asset Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2044-124X

Keywords

Article
Publication date: 11 December 2023

Hirou Karimi, Mohammad Anvar Adibhesami, Maryam Ghasemi, Borhan Sepehri and Bonin Mahdavi Estalkhsar

This study was conducted to investigate the impact of indoor environmental quality (IEQ) and internal design on the performance of students in university dormitories in Tehran and…

Abstract

Purpose

This study was conducted to investigate the impact of indoor environmental quality (IEQ) and internal design on the performance of students in university dormitories in Tehran and North Cyprus.

Design/methodology/approach

Using a survey questionnaire, 298 students living in student dormitories in Tehran and North Cyprus were surveyed for data collection.

Findings

Research has shown that the academic performance and well-being of students are heavily impacted by factors related to IEQ and internal design. The study conducted in Tehran and North Cyprus has identified the most effective components of IEQ and internal design for student dormitories. The study suggests that proper ventilation, furniture design, temperature control and lighting design are key factors that significantly affect IEQ and internal design. Control and lighting design are key factors that significantly affect IEQ and internal design.

Originality/value

Originality: The study utilizes a comparative study designed to analyze the differences and similarities between the two locations.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 21 March 2024

John Aliu, Doyin Hellen Agbaje, Ayodeji Emmanuel Oke and Andrew Ebekozien

The main objective of this study is to evaluate the driving forces behind the adoption of indoor environmental quality (IEQ) principles in building designs from the perspectives…

Abstract

Purpose

The main objective of this study is to evaluate the driving forces behind the adoption of indoor environmental quality (IEQ) principles in building designs from the perspectives of Nigerian quantity surveying firms.

Design/methodology/approach

A quantitative approach was used which involved administering a well-structured questionnaire to a sample of 114 quantity surveyors. The collected data were analyzed using various statistical methods, including frequencies, percentages, mean item scores, Kruskal–Wallis test and exploratory factor analysis.

Findings

The top five ranked drivers were climate change mitigation, conservation of natural resources, reduction of waste and pollution, use of sustainable building materials and development of new materials and building systems. Based on the factor analysis, the study identified five clusters of drivers: (1) health and well-being drivers (2) economic drivers (3) environmental drivers (4) innovation and technology drivers and (5) regulatory drivers.

Practical implications

The findings from this study suggest that to effectively integrate IEQ principles, quantity surveying firms should consider developing comprehensive guidelines and checklists that align with the identified drivers and clustered categories. These resources can serve as practical tools for project teams, facilitating a structured and holistic approach to the incorporation of IEQ factors throughout the project lifecycle.

Originality/value

The study’s identification of the top drivers and the subsequent clustering of these drivers into five distinct categories contributes to the existing body of knowledge on IEQ. This approach provides a structured framework for comprehensively understanding the factors influencing IEQ adoption, offering a valuable tool for researchers, policymakers and industry practitioners.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 4 December 2023

Abdulbasit Almhafdy and Abdullah Mohammed Alsehail

This paper investigates the optimization of window design factors (WDFs) in hospital buildings, particularly in government hospitals within the arid climate of the Qassim region…

Abstract

Purpose

This paper investigates the optimization of window design factors (WDFs) in hospital buildings, particularly in government hospitals within the arid climate of the Qassim region, with the aim of achieving a better cooling load reduction. Continuous monitoring of the hospital ward section is crucial due to patients' needs, requiring optimal indoor air quality and cooling load.

Design/methodology/approach

The study identifies the optimal conditions for WDF design to mitigate cooling load, including window-to-wall ratio (WWR), window orientation (WO), room size and U-value (thermal properties), effectively reduce energy consumption in terms of sensible cooling load (MWh/m2) and comply with local codes. Data collection involved a smart weather station, while the Integrated Environmental Solution Virtual Environment (IESVE) software facilitated the simulation process.

Findings

Key findings reveal that larger patient rooms were about 40% more energy-efficient than smaller rooms. The northern orientation showed lower energy consumption, and specific WWRs and glazing U-values significantly affected energy loads. In an analysis of U-value changes in energy performance based on the Saudi Building Code (SBC), the presented values did not meet the minimum energy consumption standards. For a valid 40% WWR with a thermal permeability of 2.89, 0.181 MWh/m2 was consumed, while for an invalid 100% WWR with the same permeability but facing the north, 0.156 MWh/m2 was consumed, which is considered an invalid practice. It is vital to follow prescribed standards to ensure energy efficiency and avoid unnecessary costs.

Originality/value

Focus lies in emphasizing the significance of adhering to prescribed standards, such as SBC, to guarantee energy efficiency and prevent unwarranted expenses. Additionally, the authors highlight the crucial role of optimizing glazing properties and allocating the WWR appropriately to achieve energy-efficient building design, accounting for diverse orientations and climatic conditions.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 12 January 2024

Elvis Attakora-Amaniampong, Iruka Chijindu Anugwo and Miller Williams Appau

This study aims to establish the relationship between indoor environmental quality and residential mobility in student housing in Ghana.

Abstract

Purpose

This study aims to establish the relationship between indoor environmental quality and residential mobility in student housing in Ghana.

Design/methodology/approach

Using multiple regression and exploratory factor analysis through post occupancy evaluation, 26 indoor environmental quality (IEQ) indicators were explored among 1,912 students living in Purpose-Built off-campus university housing in Northern Ghana.

Findings

The study established a negative relationship between indoor environmental quality and residential mobility among student housing in Northern Ghana. Residential mobility is primarily attributed to the dissatisfaction with thermal and indoor air quality.

Practical implications

The negative relationship affects vacancy and rental cashflows for property investors. Also, understanding local environmental conditions can influence future student housing design and enhance thermal and indoor air quality.

Originality/value

The authors contribute to studies on indoor environmental quality in student housing. In addition, establishing the relationship between indoor environmental quality and residential mobility in tropical African regions is novel.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 9 January 2024

Ebru Baykal Uluoz and Göksenin Inalhan

This paper aims to propose and provide an overview of a model analysis that considers the main spatial design attributes that influence and produce the most relevant salutogenic…

Abstract

Purpose

This paper aims to propose and provide an overview of a model analysis that considers the main spatial design attributes that influence and produce the most relevant salutogenic outcomes. These results are essential for a healthy work experience, especially in shared workspaces.

Design/methodology/approach

This study departs from the theoretical contributions of the salutogenic approach, principles from supportive design theory, psychosocial supportive design and the environmental demands and resources model. After a scoping literature review covering different fields of workspace design, environmental psychology and evidence-based design of health-care facilities, a conceptual analysis is done on a proposed understanding of work, health and environmental relations to overview spatial attributes that enhance specific salutogenic and well-being-promoting outcomes needed for a healthy work experience.

Findings

The model of analysis, as a theoretical element that helps create methodological tools, combined with the application of a post occupancy evaluation, is thought to assist architects, designers, workspace owners and stakeholders in their new designs or to evaluate existing ones.

Originality/value

Studies on defining spatial attributes and their intended salutogenic outcomes have been formally done in health-care facilities. However, applying this idea to shared workspaces is something new and is expected to contribute to their design and evaluation, especially if the notion of environmental demands and resources is complemented.

Details

Journal of Corporate Real Estate , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1463-001X

Keywords

Article
Publication date: 15 February 2024

D.S.N. Senarathna, K.G.A.S. Waidyasekara and S.S.C.G. Vidana

The Heating, Ventilation and Air Conditioning (HVAC) system is a significant energy consumer in built environments, and the building energy consumption could be minimised by…

Abstract

Purpose

The Heating, Ventilation and Air Conditioning (HVAC) system is a significant energy consumer in built environments, and the building energy consumption could be minimised by optimising HVAC controls. Hence, this paper aims to investigate the applicability of Variable Refrigerant Flow (VRF) air conditioning systems for optimising the indoor comfort of buildings in Sri Lanka.

Design/methodology/approach

To address the research aim, the quantitative approach following the survey research strategy was deployed. Data collected through questionnaires were analysed using descriptive statistical tools, including Mean Rating (MR), Relative Important Index (RII) and Standard Deviation (SD).

Findings

The findings revealed that VRF systems are popularly used in Sri Lankan apartment buildings. Furthermore, energy efficiency and comfort were recognised as the most significant top-ranked benefits, while ventilation issues and initial cost were recognised as significant challenges. Moreover, the allocation of trained technicians and provision of proper ventilation through a Dedicated Outdoor Air System (DOAS) were highlighted as applicable mitigation strategies for the identified challenges in VRFs.

Practical implications

The study recommends VRF systems as a suitable technology to ensure energy efficiency, reduce GHG emissions and achieve climate performance within the built environment. The opportunities for adopting VRF systems for developing countries could be explored based on the research findings. The identified challenges would assist the design engineers and facilities professionals to devise suitable strategies to mitigate issues of VRF systems in developing countries.

Originality/value

This research provides empirical proof of the energy efficiency and comfort aspects of VRFs. The study has explored and recommended VRF technology as a beneficial application to overcome the persistent energy crisis in developing countries.

Details

Property Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0263-7472

Keywords

Article
Publication date: 26 March 2024

Wael Sheta, Mariam El Hussainy and Sahar Abdelwahab

The fundamental aim of the study is to investigate the implications of labor housing designs in Dubai, with a focus on courtyards and the governing building regulations, on…

Abstract

Purpose

The fundamental aim of the study is to investigate the implications of labor housing designs in Dubai, with a focus on courtyards and the governing building regulations, on daylight performance as an underlying factor impacting laborers’ indoor environmental quality. Several studies shed light on the subject of labor camps and labor migration in Dubai, but few have focused on the subject from the perspective of the environmental performance of these camps. A model that represents one of the labor camps was built using Rhinoceros 7.0 and Grasshopper software packages. Annual daylighting and glare simulations were carried out using the lighting modeling engine RADIANCE 5.0 in conjunction with the “ClimateStudio”.

Design/methodology/approach

The construction sector has emerged as a significant economic development driver, attracting a diverse labor force from a variety of countries to Dubai. As a result, Dubai authorities have implemented several measures to ensure the provision of suitable housing facilities for its labor force. These measures contribute to the reduction of energy costs in labor housing by encouraging the use of renewable energy. While several studies shed light on the subject of labor camps and labor migration in Dubai, few have focused on the subject from the perspective of the environmental performance of these camps.

Findings

The study provided statistical evidence that the current regulations governing courtyards in labor housing resulted in significant changes in daylight levels across different floor levels of the labor housing units. It is suggested that both 2:3 and 3:4 Court Width-to-Height ratios would further contribute to a more consistent daylight Illuminance with marginal statistical differences between floor levels (p > 0.05). The 3:4 ratio, on the other hand, offers a consistent distribution across all floor levels in the North and South with negligible variances, although weakly significant differences can be yet expected between the first and fourth floors in the East and West orientations (p < 0.05). The results of Annual Sunlight Exposure (ASE) suggest excessive solar incidence and a high probability of glare, which remains a problem that must be addressed under the governing building regulations.

Originality/value

This study could serve as a framework for analyzing and contrasting the findings of other studies on labor accommodation, notably in the Gulf Cooperation Council (GCC) countries. Such an approach has the potential to enhance living conditions in labor accommodations in Dubai and other areas. It is necessary to meet people' physical and psychological well-being while also addressing sustainability and regulatory compliance.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Access

Year

Last 6 months (95)

Content type

Earlycite article (95)
1 – 10 of 95