This study aims to develop an assessment strategy for fire damaged infrastructures based on the implementation of quick diagnostic techniques and consistent interpretation…
Abstract
Purpose
This study aims to develop an assessment strategy for fire damaged infrastructures based on the implementation of quick diagnostic techniques and consistent interpretation procedures, so to determine the residual safety margin and any need for repair works.
Design/methodology/approach
In this perspective, several tailored non-destructive test (NDT) methods have been developed in the past two decades, providing immediate results, with no need for time-consuming laboratory analyses. Moreover, matching their indications with the calculated effects of a tentative fire scenario allows harmonizing distinct pieces of evidence in the coherent physical framework of fire dynamics and heat transfer.
Findings
This approach was followed in the investigations on a concrete overpass in Verona (Italy) after a coach violently impacted one supporting pillar and caught fire in 2017. Technical specifications of the vehicle made it possible to bound the acceptable ranges for fire load and maximum rate of heat release, while surveillance video footage indicated the duration of the burning stage. Some established NDT methods (evaluation of discolouration, de-hydroxylation and rebar hardness) were implemented, together with advanced ultrasonic tests based on pulse refraction and pulse-echo tomography.
Originality/value
The results clearly showed the extension of the most damaged area at the intrados of the box girders and validated the maximum heating depth, as predicted by numerical analysis of the heat transient ensuing from the localized fire model.
Details
Keywords
Abstract
Details
Keywords
This paper highlights a crucial public safety issue due to falling objects from tall residential buildings in Singapore. A systematic façade inspection regime and a system of…
Abstract
Purpose
This paper highlights a crucial public safety issue due to falling objects from tall residential buildings in Singapore. A systematic façade inspection regime and a system of evaluation of severity for the detection and assessment of potential falling objects from tall buildings are presented.
Design/methodology/approach
The research uses qualitative case study approach with 450 tall residential buildings sampled for the study. The common materials, elements, components with high risk of falling objects, the nature and type of the falling, the critical factors affecting the falling, the respective level of severity, and the effectiveness of various diagnostic techniques and protocols, are summarised.
Findings
Façade for tall residential buildings in Singapore comprises mainly cementitious materials cast in situ or precast, with fixtures and architectural features, all of which have potential of falling. The common anomalies arising from each material and fixture/features are identified, the causes evaluated and their implications to future design, construction and maintenance analysed.
Originality/value
This study provides original and significant information to a crucial public safety issue, setting design and construction criteria that will serve as a benchmark for new and existing facades, applicable to all cities dominated by tall buildings. The paper presents original figures, checklists and guides as a basis for readers' consideration to use according to their respective unique conditions.