Search results

1 – 10 of over 6000
Open Access
Article
Publication date: 2 December 2021

Roberto Felicetti

This study aims to develop an assessment strategy for fire damaged infrastructures based on the implementation of quick diagnostic techniques and consistent interpretation…

Abstract

Purpose

This study aims to develop an assessment strategy for fire damaged infrastructures based on the implementation of quick diagnostic techniques and consistent interpretation procedures, so to determine the residual safety margin and any need for repair works.

Design/methodology/approach

In this perspective, several tailored non-destructive test (NDT) methods have been developed in the past two decades, providing immediate results, with no need for time-consuming laboratory analyses. Moreover, matching their indications with the calculated effects of a tentative fire scenario allows harmonizing distinct pieces of evidence in the coherent physical framework of fire dynamics and heat transfer.

Findings

This approach was followed in the investigations on a concrete overpass in Verona (Italy) after a coach violently impacted one supporting pillar and caught fire in 2017. Technical specifications of the vehicle made it possible to bound the acceptable ranges for fire load and maximum rate of heat release, while surveillance video footage indicated the duration of the burning stage. Some established NDT methods (evaluation of discolouration, de-hydroxylation and rebar hardness) were implemented, together with advanced ultrasonic tests based on pulse refraction and pulse-echo tomography.

Originality/value

The results clearly showed the extension of the most damaged area at the intrados of the box girders and validated the maximum heating depth, as predicted by numerical analysis of the heat transient ensuing from the localized fire model.

Details

Journal of Structural Fire Engineering, vol. 13 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 June 2019

Virendra Kumar

The occurrence of multiple hazards in extreme conditions is not unknown nowadays, but the sustainability of the reinforced concrete structures under such scenarios form…

Abstract

Purpose

The occurrence of multiple hazards in extreme conditions is not unknown nowadays, but the sustainability of the reinforced concrete structures under such scenarios form competitive challenges in civil engineering profession. Among all, fire following earthquake (FFE) is categorized under multiple extreme load scenarios which causes sequential damages to the structures. This paper aims to experiment a full-scale RC frame sub-assemblage for the FFE scenario and assess each stage of damage through the nondestructive testing method.

Design/methodology/approach

Two levels of simulated earthquake damages, i.e. immediate occupancy (IO) level and life safety (LS) level of structural performance were induced to the test frame and then, followed by a realistic compartment fire of 1 h duration. Also, the evaluation of damage to the RC frame after the fire subsequent to the earthquake was carried out by obtaining the ultimate capacity of the frame. Ultrasonic pulse velocity and rebound hammer test were conducted to assess the structural endurance of the damaged frame. Cracks were also marked during mechanical damages to the test frame to study the nature of its propagation.

Findings

Careful visual inspection during and after the fire test to the test frame were done. To differentiate between concrete chemically affected by the fire or physically damaged is an important issue. In situ inspection and laboratory tests of concrete components have been performed. Concrete from the test frame was localized with thermo-gravimetric analysis. The UPV results exhibited a sharp decrease in the strength of the concrete material which was also confirmed via the DTA, TGA and TG results. It is important to evaluate the residual capacity of the entire structure under the FFE scenario and propose rehabilitation/retrofit schemes for the building structure.

Research limitations/implications

The heterogeneity in the distribution of the damage has been identified due to variation of fire exposure. The study only highlights the capabilities of the methods for finding the residual capacity of the RC frame sub-assemblage after an occurrence of an FFE.

Originality/value

It is of find kind of research work on full-scale reinforced concrete building. In this, an attempt has been made for the evaluation of concrete structures affected by an FFE through nondestructive and destructive methods.

Details

Journal of Structural Fire Engineering, vol. 10 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 June 2017

Chrysanthos Maraveas, Zacharias Fasoulakis and Konstantinos Daniel Tsavdaridis

This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural…

Abstract

Purpose

This paper aims to present technical aspects of the assessment method and evaluation of fire damaged steel structures. The current work focuses on the behavior of structural normal steel (hot-rolled and cold-formed) and high-strength bolts after exposure to elevated temperatures. Information on stainless steel, cast iron and wrought iron is also presented.

Design/methodology/approach

Because of the complexity of the issue, an elaborate presentation of the mechanical properties influencing factors is followed. Subsequently, a wide range of experimental studies is extensively reviewed in the literature while simplified equations for determining the post-fire mechanical properties are proposed, following appropriate categorization. Moreover, the reinstatement survey is also comprehensively described.

Findings

Useful conclusions are drawn for the safe reuse of the structural elements and connection components. According to the parametric investigation of the aforementioned data, it can be safely concluded that the most common scenario of buildings after fire events, i.e. apart from excessively distorted structures, implies considerable remaining capacity of the structure, highlighting that subsequent demolition should not be the case, especially regarding critical infrastructure and buildings.

Originality/value

The stability of the structure as a whole is addressed, with aim to establish specific guidelines and code provisions for the correct appraisal and rehabilitation of fire damaged structures.

Details

Journal of Structural Fire Engineering, vol. 8 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 April 1988

Paul Swinney

This case study concerns a two‐storey supermarket building which was partially gutted by fire during the Handsworth riots in Birmingham in 1985. Burks Green and Partners were…

Abstract

This case study concerns a two‐storey supermarket building which was partially gutted by fire during the Handsworth riots in Birmingham in 1985. Burks Green and Partners were commissioned by the loss adjustors to investigate the structural significance of damage to the building and to advise on the viability of repair. Representatives of the insured considered that the best course of action was to demolish and rebuild. In the course of investigation, certain inherent defects in the structure also became apparent and it was necessary to encompass these within the repair scheme. In order to satisfy the owner's representatives about the effectiveness of proposed repairs, a trial area was first repaired and load‐tested.

Details

Structural Survey, vol. 6 no. 4
Type: Research Article
ISSN: 0263-080X

Article
Publication date: 1 January 1983

D.M. Tucker and R.E.H. Read

Buildings, or portions of buildings, look a sorry sight after a fire: some may have collapsed and be only twisted ruins, others may have mainly suffered damage from smoke. Between…

Abstract

Buildings, or portions of buildings, look a sorry sight after a fire: some may have collapsed and be only twisted ruins, others may have mainly suffered damage from smoke. Between these extremes there is a wide range of degree of damage. This paper provides some guidance and references on the effects of fire on building materials and structural components so that decisions as to repairability are not based wholly on superficial appearances.

Details

Structural Survey, vol. 1 no. 1
Type: Research Article
ISSN: 0263-080X

Article
Publication date: 27 July 2021

Mervin Ealiyas Mathews, Anand N, Diana Andrushia A, Tattukolla Kiran and Khalifa Al-Jabri

Building elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used…

Abstract

Purpose

Building elements that are damaged by fire are often strengthened by fiber wrapping techniques. Self-compacting concrete (SCC) is an advanced building material that is widely used in construction due to its ability to flow and pass through congested reinforcement and fill the required areas easily without compaction. The aim of the research work is to examine the flexural behavior of SCC subjected to elevated temperature. This research work examines the effect of natural air cooling (AC) and water cooling (WC) on flexural behavior of M20, M30, M40 and M50 grade fire-affected retro-fitted SCC. The results of the investigation will enable the designers to choose the appropriate repair technique for improving the service life of structures.

Design/methodology/approach

In this study, an attempt has been made to evaluate the flexural behavior of fire exposed reinforced SCC beams retrofitted with laminates of carbon fiber reinforced polymer (CFRP), basalt fiber reinforced polymer (BFRP) and glass fiber reinforced polymer (GFRP). Beam specimens were cast with M20, M30, M40 and M50 grades of SCC and heated to 925ºC using an electrical furnace for 60 min duration following ISO 834 standard fire curve. The heated SCC beams were cooled by either natural air or water spraying.

Findings

The reduction in the ultimate load carrying capacity of heated beams was about 42% and 55% for M50 grade specimens that were cooled by air and water, respectively, in comparison with the reference specimens. The increase in the ultimate load was 54%, 38% and 27% for the specimens retrofitted with CFRP, BFRP and GFRP, respectively, compared with the fire-affected specimens cooled by natural air. Water-cooled specimens had shown higher level of damage than the air-cooled specimens. The specimens wrapped with carbon fiber could able to improve the flexural strength than basalt and glass fiber wrapping.

Originality/value

SCC, being a high performance concrete, is essential to evaluate the performance under fire conditions. This research work provides the flexural behavior and physical characteristics of SCC subjected to elevated temperature as per ISO rate of heating. In addition attempt has been made to enhance the flexural strength of fire-exposed SCC with wrapping using different fibers. The experimental data will enable the engineers to choose the appropriate material for retrofitting.

Details

Journal of Structural Fire Engineering, vol. 12 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 April 2004

David A. McEntire and Amy Myers

This paper discusses what local governments must do to prepare for various disasters, including terrorist attacks. It provides background information on preparedness and…

5930

Abstract

This paper discusses what local governments must do to prepare for various disasters, including terrorist attacks. It provides background information on preparedness and highlights lessons from prior research. It also identifies the process of establishing local ordinances, assessing risk, creating emergency operations plans, acquiring resources, instituting mutual aid agreements, training, exercising and educating the public. Finally, it concludes with recommendations to implement these preparedness measures.

Details

Disaster Prevention and Management: An International Journal, vol. 13 no. 2
Type: Research Article
ISSN: 0965-3562

Keywords

Article
Publication date: 15 July 2021

Vishal M. and Satyanarayanan K.S.

This paper delineates a literature review on fire-induced progressive collapse on structures and the effect of high temperature on structures and elements. After the occurrences…

Abstract

Purpose

This paper delineates a literature review on fire-induced progressive collapse on structures and the effect of high temperature on structures and elements. After the occurrences of fire in the World Trade Center in the USA, the researchers started concentrating on the progressive collapse that happens due to high temperature. Currently, most of the researchers are working on fire-induced progressive collapse on structures using high-temperature behavior on materials which are used for construction. The researchers have been doing an intensive study to find a better strategy to prevent the building from structural fire damage or collapse with available codes and guidelines throughout the world. This paper aims to provide a better understanding and analytical solutions on the basis of the recent works done by researchers in fire-induced progressive collapse and methods adopted to find the collapse mechanism.

Design/methodology/approach

This paper is written by studying different literature papers of 109 related to progressive collapse on structures and fire-induced progressive collapse.

Findings

The behavior of structures due to high temperature and collapse conditions due to fire in different scenarios is identified.

Originality/value

This paper fulfills an identified need to study how the structure can withstand high-temperature conditions in our day-to-day lives.

Details

Journal of Structural Fire Engineering, vol. 12 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 December 2023

T.M. Jeyashree and P.R. Kannan Rajkumar

This study focused on identifying critical factors governing the fire response of prestressed hollow-core slabs. The hollow-core slabs used as flooring units can be subjected to…

Abstract

Purpose

This study focused on identifying critical factors governing the fire response of prestressed hollow-core slabs. The hollow-core slabs used as flooring units can be subjected to elevated temperatures during a fire. The fire response of prestressed hollow-core slabs is required to develop slabs with greater fire endurance. The present study aims to determine the extent to which the hollow-core slab can sustain load during a fire without undergoing progressive collapse under extreme fire and heating scenarios.

Design/methodology/approach

A finite element model was generated to predict the fire response of prestressed hollow core slabs under elevated temperatures. The accuracy of the model was predicted by examining thermal and structural responses through coupled temperature displacement analysis. A sensitivity analysis was performed to study the effects of concrete properties on prediction of system response. A parametric study was conducted by varying the thickness of the slab, fire and heating scenarios.

Findings

Thermal conductivity and specific heat of concrete were determined as sensitive parameters. The thickness of the slab was identified as a critical factor at a higher load level. Asymmetric heating of the slab resulted in higher fire resistance compared with symmetric heating.

Originality/value

This is the first study focused on studying the effect of modeling uncertainties on the system response by sensitivity analysis under elevated temperatures. The developed model with a parametric study helps in identifying critical factors for design purposes.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 7 July 2017

Muhammad Masood Rafi, Tariq Aziz and Sarosh Hashmat Lodi

This paper aims to present the results of testing of low-strength concrete specimens exposed to elevated temperatures. These data are limited in the existing literature and do not…

Abstract

Purpose

This paper aims to present the results of testing of low-strength concrete specimens exposed to elevated temperatures. These data are limited in the existing literature and do not exist in Pakistan.

Design/methodology/approach

An experimental testing programme has been employed. Cylindrical specimens of 100 × 200 mm were used in the testing programme. These were heated at temperatures which were varied from 100°C to 900°C in increment of 100°C. Similar specimens were tested at ambient temperature as control specimens. The compressive and tensile properties of heat treated specimens were determined.

Findings

The colour of concrete started to change at 300°C and hairline cracks appeared at 400°C. Explosive spalling was observed in few specimens in the temperature range of 400°C-650°C which could be attributed to the pore pressure generated by steam. Significant loss of concrete compressive strength occurred on heating temperatures larger than 600°C, and the residual compressive strength was found to be 15 per cent at 900°C. Residual tensile strength of concrete became less than 10 per cent at 900°C. The loss of concrete stiffness reached 85 per cent at 600°C. Residual Poisson’s ratio of concrete increased at high temperatures and became nearly six times larger at 900°C as compared to that at ambient temperature.

Research limitations/implications

The parameters of the study included heating temperature and effects of temperature on strength and stiffness properties of the concrete specimens.

Practical implications

Building fire incidents have increased in Pakistan. As a large number of reinforced concrete (RC) buildings exist in the country, the data related to elevated temperature properties of concrete are required. These data are not available in Pakistan presently. The study aims at providing this information for the design engineers to enable them to assess and increase fire resistance of RC structural members.

Originality/value

The presented study is unique in its nature in that there is no published contribution to date, to the best of authors’ knowledge, which has been carried out to assess the temperature-dependent mechanical properties of concrete in Pakistan.

Details

Journal of Structural Fire Engineering, vol. 8 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

1 – 10 of over 6000