Search results
1 – 10 of 27Xudong He, GuangYi Yang, E. Yang, Moli Zhang, Dan Luo, Jingjian Liu, Chongnan Zhao, Qinhua Chen and Fengying Ran
Based on DNase I and reduced graphene oxide (rGO)-magnetic silicon microspheres (MNPS), a highly sensitive and selective fluorescent probe for the detection of PD-L1 was developed.
Abstract
Purpose
Based on DNase I and reduced graphene oxide (rGO)-magnetic silicon microspheres (MNPS), a highly sensitive and selective fluorescent probe for the detection of PD-L1 was developed.
Design/methodology/approach
Here °C we present a feasibility of biosensor to detection of PD-L1 in lung tumors plasma. In the absence of PD-L1°C the PD-L1 aptamer is absorbed on the surface of graphene oxide modified magnetic nanoparticles °8rGO-MNPS°9 and leading to effective fluorescence quenching. Upon adding PD-L1°C the aptamer sequences could be specifically recognized by PD-L1 and the aptamer/PD-L1 complex is formed°C resulting in the recovery of quenched fluorescence.
Findings
This sensor can detect PD-L1 with a linear range from 100 pg mL−1 to 100 ng mL−1, and a detection limit of 10 pg•m−1 was achieved.
Originality/value
This method provides an easy and sensitive method for the detection of PD-L1 and will be beneficial to the early diagnosis and prognosis of tumors.
Details
Keywords
Tomasz Matusiak, Krzysztof Swiderski, Jan Macioszczyk, Piotr Jamroz, Pawel Pohl and Leszek Golonka
The purpose of this paper is to present a study on miniaturized instruments for analytical chemistry with a microplasma as the excitation source.
Abstract
Purpose
The purpose of this paper is to present a study on miniaturized instruments for analytical chemistry with a microplasma as the excitation source.
Design/methodology/approach
The atmospheric pressure glow microdischarge could be ignited inside a ceramic structure between a solid anode and a liquid cathode. As a result of the cathode sputtering of the solution, it was possible to determine its chemical composition by analyzing the emission spectra of the discharge. Cathodes with microfluidic channels and two types of anodes were constructed. Both types were tested through experimentation. Impact of the electrodes geometry on the discharge was established. A cathode aperture of various sizes and anodes made from different materials were used.
Findings
The spectroscopic properties of the discharge and its usefulness in the analysis depended on the ceramic structure. The surface area of the cathode aperture and the flow rate of the solution influence on the detection limits (DLs) of Zn and Cd.
Originality/value
Constructed ceramic structures were able to excite elements and their laboratory-size systems. During the experiments, Zn and Cd were detected with DLs 0.024 and 0.053 mg/L, respectively.
Details
Keywords
Abstract
Details
Keywords
Emmanuel Arhin, Raymond Webrah Kazapoe and Fulera Salami
The purpose of this study was to define and outline areas prone to disease causing elements by analyzing the spatial distribution and concentration of toxic and essential elements…
Abstract
Purpose
The purpose of this study was to define and outline areas prone to disease causing elements by analyzing the spatial distribution and concentration of toxic and essential elements in a section of the Voltaian sedimentary basin.
Design/methodology/approach
A total of 2,668 soil samples were analysed by the inductively coupled plasma mass spectrometry technique and were re-appraised by comparing with baseline values of elements accepted globally to be in soils. The concentrations of arsenic (As), chromium (Cr), iron (Fe) and magnesium (Mg) were evaluated. Factor analysis, hierarchical cluster analysis and principal component analysis multivariate techniques were used to identify the source patterns of the elements in the soils. The Getis-Ord Gi method was used to generate the optimised maps for these selected elements. These maps spatially defined and outlined high value clusters which imply potential pollution or areas with high background values (hotspots), whereas the low value clusters imply areas with low background values (cold-spots).
Findings
The multivariate analysis supports a dominant geogenic source of these heavy elements with obvious influences from variably metamorphosed mafic–ultramafic rocks known to have contributed to the deposition of sediments in the basin. The hotspots for As were located around Nalerigu and to the east of Nawchugu. A Cr hotspot was located to the east of Nawchugu with Cr cold-spots located within Nalerigu and Yunyuo. Fe hotspots were observed to the south of Nalerigu and the east of Nawchugu with Fe cold-spots around Yunyuo, Bongo-Da and Nagbo. The spatial maps demonstrated the presence of toxic and deficient areas of all the selected elements used in the investigation. Therefore, it suggested the likely health implications depending on the exposed elements, their pathways and recommended the usefulness of using the results displayed in the spatial maps to guide in devising appropriate remediation techniques.
Originality/value
This paper fulfils an identified need to study the distribution of elements and the possible effects it may have on the health and livelihoods of those residing in these areas.
Details
Keywords
Thomas Wopelka, Ulrike Cihak-Bayr, Claudia Lenauer, Ferenc Ditrói, Sándor Takács, Johannes Sequard-Base and Martin Jech
This paper aims to investigate the wear behaviour of different materials for cylinder liners and piston rings in a linear reciprocating tribometer with special focus on the wear…
Abstract
Purpose
This paper aims to investigate the wear behaviour of different materials for cylinder liners and piston rings in a linear reciprocating tribometer with special focus on the wear of the cylinder liner in the boundary lubrication regime.
Design/methodology/approach
Conventional nitrided steel, as well as diamond-like carbon and chromium nitride-coated piston rings, were tested against cast iron, AlSi and Fe-coated AlSi cylinder liners. The experiments were carried out with samples produced from original engine parts to have the original surface topography available. Radioactive tracer isotopes were used to measure cylinder liner wear continuously, enabling separation of running-in and steady-state wear.
Findings
A ranking of the material pairings with respect to wear behaviour of the cylinder liner was found. Post-test inspection of the cylinder samples by scanning electron microscopy (SEM) revealed differences in the wear mechanisms for the different material combinations. The results show that the running-in and steady-state wear of the liners can be reduced by choosing the appropriate material for the piston ring.
Originality/value
The use of original engine parts in a closely controlled tribometer environment under realistic loading conditions, in conjunction with continuous and highly sensitive wear measurement methods and a detailed SEM analysis of the wear mechanisms, forms an intermediate step between engine testing and laboratory environment testing.
Details
Keywords
Abstract
Details