1 – 10 of 10Hang Jia, Zhiming Gao, Shixiong Wu, Jia Liang Liu and Wenbin Hu
This study aims to investigate the corrosion inhibitor effect of migrating corrosion inhibitor (MCI) on Q235 steel in high alkaline environment under cathodic polarization.
Abstract
Purpose
This study aims to investigate the corrosion inhibitor effect of migrating corrosion inhibitor (MCI) on Q235 steel in high alkaline environment under cathodic polarization.
Design/methodology/approach
This study investigated the electrochemical characteristics of Q235 steel with and without MCI by polarization curve and electrochemical impedance spectroscopy. Besides, the surface composition of Q235 steel under different environments was analyzed by X-ray photoelectron spectroscopy. In addition, the migration characteristic of MCI and the adsorption behavior of MCI under cathodic polarization were studied using Raman spectroscopy.
Findings
Diethanolamine (DEA) and N, N-dimethylethanolamine (DMEA) can inhibit the increase of Fe(II) in the oxide film of Q235 steel under cathodic polarization. The adsorption stability of DMEA film was higher under cathodic polarization potential, showing a higher corrosion inhibition ability. The corrosion inhibition mechanism of DEA and DMEA under cathodic polarization potential was proposed.
Originality/value
The MCI has a broad application prospect in the repair of damaged reinforced concrete due to its unique migratory characteristics. The interaction between MCIs, rebar and concrete with different compositions has been studied, but the passivation behavior of the steel interface in the presence of both the migrating electric field and corrosion inhibitors has been neglected. And it was investigated in this paper.
Details
Keywords
Nehal Elshaboury, Tarek Zayed and Eslam Mohammed Abdelkader
Water pipes degrade over time for a variety of pipe-related, soil-related, operational, and environmental factors. Hence, municipalities are necessitated to implement effective…
Abstract
Purpose
Water pipes degrade over time for a variety of pipe-related, soil-related, operational, and environmental factors. Hence, municipalities are necessitated to implement effective maintenance and rehabilitation strategies for water pipes based on reliable deterioration models and cost-effective inspection programs. In the light of foregoing, the paramount objective of this research study is to develop condition assessment and deterioration prediction models for saltwater pipes in Hong Kong.
Design/methodology/approach
As a perquisite to the development of condition assessment models, spherical fuzzy analytic hierarchy process (SFAHP) is harnessed to analyze the relative importance weights of deterioration factors. Afterward, the relative importance weights of deterioration factors coupled with their effective values are leveraged using the measurement of alternatives and ranking according to the compromise solution (MARCOS) algorithm to analyze the performance condition of water pipes. A condition rating system is then designed counting on the generalized entropy-based probabilistic fuzzy C means (GEPFCM) algorithm. A set of fourth order multiple regression functions are constructed to capture the degradation trends in condition of pipelines overtime covering their disparate characteristics.
Findings
Analytical results demonstrated that the top five influential deterioration factors comprise age, material, traffic, soil corrosivity and material. In addition, it was derived that developed deterioration models accomplished correlation coefficient, mean absolute error and root mean squared error of 0.8, 1.33 and 1.39, respectively.
Originality/value
It can be argued that generated deterioration models can assist municipalities in formulating accurate and cost-effective maintenance, repair and rehabilitation programs.
Details
Keywords
Dejing Zhou, Yanming Xia, Zhiming Gao and Wenbin Hu
This study aims to investigate the influence mechanism of brazing and aging on the strengthening and corrosion behavior of novel multilayer sheets (AA4045/AA7072/AA3003M/AA4045).
Abstract
Purpose
This study aims to investigate the influence mechanism of brazing and aging on the strengthening and corrosion behavior of novel multilayer sheets (AA4045/AA7072/AA3003M/AA4045).
Design/methodology/approach
Polarization curve tests, immersion experiments and transmission electron microscopy analysis were used to study the corrosion behavior and tensile properties of the sheets before and after brazing and aging.
Findings
The strength of the sheet is weakened after brazing due to brittle eutectic phases, and recovered after aging due to enhanced precipitation strengthening in the AA7072 interlayer. The core of nonbrazed sheets cannot be protected due to the significant galvanic coupling effect between the intermetallic particles and the substrate. Brazing and aging treatments promote the redissolved of second phased and limit corrosion along the eutectic region in the clad, allowing the core to be protected.
Originality/value
AA7xxx alloy was added to conventional brazed sheets to form a novel Al alloy composite sheet with AA4xxx/AA7xxx/AA3xxx structure. The strengthening and corrosion mechanism of the sheet was proposed. The added interlayer can sacrificially protect the core from corrosion and improves strength after aging treatment.
Details
Keywords
Suyun Liu, Hu Liu, Ningning Shao, Zhijun Dong, Rui Liu, Li Liu and Fuhui Wang
Polyaniline (PANI) has garnered attention for its potential applications in anticorrosion fields because of its unique properties. Satisfactory outcomes have been achieved when…
Abstract
Purpose
Polyaniline (PANI) has garnered attention for its potential applications in anticorrosion fields because of its unique properties. Satisfactory outcomes have been achieved when using PANI as a functional filler in organic coatings. More recently, research has extensively explored PANI-based organic coatings with self-healing properties. The purpose of this paper is to provide a summary of the active agents, methods and mechanisms involved in the self-healing of organic coatings.
Design/methodology/approach
This study uses specific doped acids and metal corrosion inhibitors as active and self-healing agents to modify PANI using the methods of oxidation polymerization, template synthesis, nanosheet carrier and nanocontainer loading methods. The anticorrosion performance of the coatings is evaluated using EIS, LEIS and salt spray tests.
Findings
Specific doped acids and metal corrosion inhibitors are used as active agents to modify PANI and confer self-healing properties to the coatings. The coatings’ active protection mechanism encompasses PANI’s own passivation ability, the adsorption of active agents and the creation of insoluble compounds or complexes.
Originality/value
This paper summarizes the active agents used to modify PANI, the procedures used for modification and the self-healing mechanism of the composite coatings. It also proposes future directions for developing PANI organic coatings with self-healing capabilities. The summaries and proposals presented may facilitate large-scale production of the PANI organic coatings, which exhibit outstanding anticorrosion competence and self-healing properties.
Details
Keywords
Shuangjiu Deng, Chang Li, Xing Han, Menghui Yu and Han Sun
The restoration and strengthening of QT600 is an industry bottleneck challenge. The Co-12 cladding layer has great wear and corrosion resistance. The purpose of this paper is to…
Abstract
Purpose
The restoration and strengthening of QT600 is an industry bottleneck challenge. The Co-12 cladding layer has great wear and corrosion resistance. The purpose of this paper is to quantitatively reveal the transient evolution law of the corrosion process of Co-12 cladding layer on QT600 surface.
Design/methodology/approach
In this paper, a three-dimensional numerical model of the corrosion process of Co-12 cladding layer by QT600 laser cladding is established. The interaction between pitting pits and corrosion medium is considered to reveal the transient evolution of ion concentration, electrode potential, pH and corrosion rate at different locations.
Findings
The calculation shows that the ion concentration in pitting pit changes Cl−>Co2+>Na+, pH value decreases from top to bottom and corrosion rate at bottom is greater than that at top. The electrochemical corrosion test of Co-12 cladding layer was carried out. It is shown that the current density of QT600 increases by an order of magnitude compared to the Co-12 cladding layer, and the corrosion rate is 4.862 times higher than that of the cladding layer.
Originality/value
The results show that Co-12 cladding layer has great corrosion resistance, which provides an effective way for QT600 protection.
Details
Keywords
Yaqi Diao, Jihui Wang, Renhong Song, Xue Fei, Zhichang Xue and Wenbin Hu
The purpose of this paper is to prepare a multifunctional nanocomposite that is slow-release and resistant to seawater corrosion and biofouling corrosion and to explore the…
Abstract
Purpose
The purpose of this paper is to prepare a multifunctional nanocomposite that is slow-release and resistant to seawater corrosion and biofouling corrosion and to explore the synergistic effect between the two corrosion inhibitors.
Design/methodology/approach
The morphology, structure and release properties of CAP@HNTs, BTA@HNTs and CAP/BTA@HNTs were investigated by scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, specific surface area analysis and UV spectrophotometry. The corrosion resistance and antimicrobial properties were investigated by electrochemical measurements and bioinhibition rate tests, and the synergistic effect between the two corrosion inhibitors was explored by X-ray photoelectron spectroscopy.
Findings
The CAP/BTA@HNTs are responsive to acidic environments and have significantly improved antibacterial and corrosion resistance compared with CAP@HNTs and BTA@HNTs. CAP and BTA have a positive synergistic effect on anticorrosion and antifouling.
Originality/value
Two types of inhibitors, anticorrosion and antifouling, were loaded into the same nanocontainer to prepare a slow-releasable and multifunctional nanocomposite with higher resistance to seawater corrosion and biocorrosion and to explore the synergistic effect of CAP and BTA on corrosion resistance.
Details
Keywords
Shahriar Abubakri, Pritpal S. Mangat, Konstantinos Grigoriadis and Vincenzo Starinieri
Microwave curing (MC) can facilitate rapid concrete repair in cold climates without using conventional accelerated curing technologies which are environmentally unsustainable…
Abstract
Purpose
Microwave curing (MC) can facilitate rapid concrete repair in cold climates without using conventional accelerated curing technologies which are environmentally unsustainable. Accelerated curing of concrete under MC can contribute to the decarbonisation of the environment and provide economies in construction in several ways such as reducing construction time, energy efficiency, lower cement content, lower carbonation risk and reducing emissions from equipment.
Design/methodology/approach
The paper investigates moisture loss and pore properties of six cement-based proprietary concrete repair materials subjected to MC. The impact of MC on these properties is critically important for its successful implementation in practice and current literature lacks this information. Specimens were microwave cured for 40–45 min to surface temperatures between 39.9 and 44.1 °C. The fast-setting repair material was microwave cured for 15 min to 40.7 °C. MC causes a higher water loss which shows the importance of preventing drying during MC and the following 24 h.
Findings
Portland cement-based normal density repair mortars, including materials incorporating pfa and polymer latex, benefit from the thermal effect of MC on hydration, resulting in up to 24% reduction in porosity relative to normal curing. Low density and flowing repair materials suffer an increase in porosity up to 16% due to MC. The moisture loss at the end of MC and after 24h is related to the mix water content and porosity, respectively.
Originality/value
The research on the application of MC for rapid repair of concrete is original. The research was funded by the European commission following a very rigorous and competitive review process which ensured its originality. Original data on the parameters of porosity and moisture loss under MC are provided for different generic cementitious repair materials which have not been studied before. Application of MC to concrete construction especially in cold climates will provide environmental, economic and energy benefits.
Details
Keywords
Ayad Alameeri, Gholamreza Abdollahzadeh and Seyedkomeil Hashemiheidari
This study aims to determine the effect of replacing a portion of the cement in the concrete mixture with silica fume (SF) on the corrosion resistance of reinforcing bars, the…
Abstract
Purpose
This study aims to determine the effect of replacing a portion of the cement in the concrete mixture with silica fume (SF) on the corrosion resistance of reinforcing bars, the compressive strength of concrete and the tensile strength of hook bars in both corroded and non-corroded external joints of structures. The external beam-column connection was studied because of its critical role in maintaining structural continuity in all three directions and providing resistance to rotation.
Design/methodology/approach
In external concrete joints, the bars at the end of the beams are often bent at 90° to form hooks that embed in columns. Owing to the importance of embedding distance and the need to understand its susceptibility to corrosion damage from chloride attack, a series of experiments were conducted on 12 specimens that accurately simulate real-site conditions in terms of dimensions, reinforcement and hook bars. SF was replaced with 10% and 15% of the weight of cement in the concrete mixture. To simulate corrosion, the specimens were subjected to accelerated corrosion in the laboratory by applying a low continuous current of 0.35 mA for 58 days.
Findings
The results revealed the effect of SF in improving the compressive strength of concrete, the pullout resistance of the hook bars and the corrosion resistance. In addition, it showed an apparent effect of the corrosion of reinforcing bars in reducing the bonding strength of hook bars with concrete and the effect of SF in improving this strength.
Originality/value
It was noted that the improvement of the results, achieved by replacing 10% of the weight of cement with SF, was significantly close to the results obtained by replacing 15% of the SF. It is recommended that an SF ratio of 10% be adopted to achieve the greatest economic savings.
Details
Keywords
Song Tang, Xiaowen Chen, Defen Zhang, Wanlin Xie, Qingzheng Ran, Bin Luo, Han Luo and Junwei Yang
The purpose of this study is to investigate the influence of varying concentrations of nano-SiO2 particle doping on the structure and properties of the micro-arc oxidation (MAO…
Abstract
Purpose
The purpose of this study is to investigate the influence of varying concentrations of nano-SiO2 particle doping on the structure and properties of the micro-arc oxidation (MAO) coating of 7075 aluminum alloy. This research aims to provide novel insights and methodologies for the surface treatment and protection of 7075 aluminum alloy.
Design/methodology/approach
The surface morphology of the MAO coating was characterized using scanning electron microscope. Energy spectrometer was used to characterize the elemental content and distribution on the surface and cross section of the MAO coating. The phase composition of the MAO coating was characterized using X-ray diffractometer. The corrosion resistance of the MAO coating was characterized using an electrochemical workstation.
Findings
The results showed that when the addition of nano-SiO2 particles is 3 g/L, the corrosion resistance is optimal.
Originality/value
This study investigated the influence of different concentrations of nano-SiO2 particles on the structure and properties of the MAO coating of 7075 aluminum alloy.
Details
Keywords
Bassem Assfour, Bassam Abdallah, Hour Krajian, Mahmoud Kakhia, Karam Masloub and Walaa Zetoune
The purpose of this study is to investigate the structural, surface roughness and corrosion properties of the zirconium oxide thin films deposited onto SS304 substrates using the…
Abstract
Purpose
The purpose of this study is to investigate the structural, surface roughness and corrosion properties of the zirconium oxide thin films deposited onto SS304 substrates using the direct current (DC) magnetron sputtering technique.
Design/methodology/approach
DC sputtering at different powers – 80, 100 and 120 W – was used to deposit ZrO2 thin films onto different substrates (Si/SS304) without annealing of the substrate. Atomic force microscope (AFM), energy-dispersive X-ray spectroscopy (EDS), Tafel extrapolation and contact angle techniques were applied to investigate the surface roughness, chemical compositions, corrosion behavior and hydrophobicity of these films.
Findings
Results showed that the thickness of the deposited film increased with power increase, while the corrosion current decreased with power increase. AFM images indicated that the surface roughness decreased with an increase in DC power. EDS analysis showed that the thin film has a stoichiometric ZrO2 (Zr:O 1:2) composition with basic uniformity. Water contact angle measurements indicated that the hydrophobicity of the synthesized films decreased with an increase in surface roughness.
Originality/value
DC magnetron sputtering technique is infrequently used to deposition thin films. The obtained thin films showed good hydrophobic and anticorrosion properties. Finally, results are compared with other deposition techniques.