Article
Publication date: 26 July 2021

Zhong Li, Xiaojia Yang, Jing Liu, Zhiyong Liu, Xiaogang Li and Yan Tingting

The purpose of this paper is to determine the failure reasons and failure mechanism of the commercially pure titanium air conditioning condenser.

Abstract

Purpose

The purpose of this paper is to determine the failure reasons and failure mechanism of the commercially pure titanium air conditioning condenser.

Design/methodology/approach

In this paper, chemical analysis, metallographic observation, visual examination and scanning electron microscope examination, corrosion products analysis and working conditions analysis were adopted for determining the reasons for the failure of the condenser.

Findings

The results indicated that TA2 titanium pipe perforation failure is caused by the synergistic effect of crevice corrosion and deposit corrosion. The corrosion processes can be divided into three steps.

Originality/value

This research is an originality study on the failure case of a commercially pure titanium air conditioning condenser. This study makes up for the shortage of titanium alloy failure cases and also gives the result of the failure reason and failure mechanism for titanium, which has an engineering significance.

Details

Anti-Corrosion Methods and Materials, vol. 68 no. 4
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 1 March 1989

Bennett J. Price

This article discusses the basics of computer‐room air conditioning, an important component of the special environment required by mainframe computers and many mini‐computers as…

Abstract

This article discusses the basics of computer‐room air conditioning, an important component of the special environment required by mainframe computers and many mini‐computers as well. Computer room air conditioners differ in some significant ways from “comfort” airconditioners, which are designed for the comfort of people rather than machines. These differences make it less than ideal to use air conditioning systems designed for human comfort for computer cooling. The author describes several different types of airconditioners, considerations related to the construction of a computer room, and factors that determine air‐conditioning requirements.

Details

Library Hi Tech, vol. 7 no. 3
Type: Research Article
ISSN: 0737-8831

Book part
Publication date: 5 June 2023

Sonali A. Deshmukh, Praveen Barmavatu, Mihir Kumar Das, Bukke Kiran Naik, Vineet Singh Sikarwar, Alety Shivakrishna, Radhamanohar Aepuru and Rathod Subash

This study has covered many types of solar-powered air-conditioning systems that may be used as an alternative to traditional electrically powered air-conditioning systems in…

Abstract

This study has covered many types of solar-powered air-conditioning systems that may be used as an alternative to traditional electrically powered air-conditioning systems in order to reduce energy usage. Solar adsorption air cooling is a great alternative to traditional vapor compression air-conditioning. Solar adsorption has several advantages over traditional vapor-compression systems, including being a green cooling technology which uses solar energy to drive the cycle, using pure water as an eco-friendly HFC-free refrigerant, and being mechanically simple with only the magnetic valves as moving parts. Several advancements and breakthroughs have been developed in the area of solar adsorption air-conditioners during the previous decade. However, further study is required before this technology can be put into practise. As a result, this book chapter highlights current research that adds to the understanding of solar adsorption air-conditioning technologies, with a focus on practical research. These systems have the potential to become the next iteration of air-conditioning systems, with the benefit of lowering energy usage while using plentiful solar energy supplies to supply the cooling demand.

Article
Publication date: 1 July 2006

Andrea Furlan, Pietro Romano and Arnaldo Camuffo

This paper explores what suppliers and customers do in order to integrate their operations across the supply chain. It also identifies on what contextual factors these specific…

1791

Abstract

Purpose

This paper explores what suppliers and customers do in order to integrate their operations across the supply chain. It also identifies on what contextual factors these specific CSI practices are contingent.

Design/methodology/approach

The paper uses the multiple case study methodology as a basis for theory formulation. Insights from nine cases of OEM‐supplier relationships in the Italian high precision air conditioning industry are used to address the research questions and formulate theoretical propositions.

Findings

The paper develops four theoretical propositions derived from a framework that identifies four CSI forms contingent on two contextual variables – the value impact of goods purchased from each supplier and the degree of purchasing goods customization.

Research limitations/implications

This paper provides a framework that advances the understanding of effective supplier relations management in two ways. Firstly, it gets over the traditional dichotomy between arm's length relationships and strategic partnerships by identifying a more articulated typology of CSI forms. Secondly, it characterizes each of the four CSI forms in terms of the practices buyers and suppliers apply to manage four key business processes.

Practical implications

The paper provides a template to configure integration in customer‐supplier relations and suggests the different mix of integrative practices business partners should use in diverse supply chain environments.

Originality/value

The proposed framework improves existing theory that either considers one single aspect of customer‐supplier relations (i.e. pricing, logistics, or new product development) or interprets interfirm collaboration as a single dimension phenomenon.

Details

Journal of Manufacturing Technology Management, vol. 17 no. 5
Type: Research Article
ISSN: 1741-038X

Keywords

Article
Publication date: 1 February 1986

New four‐frequency tube inspection system. Hocking NDT has introduced Phasec D8, a new four channel multi‐frequency non‐destructive test system for the internal inspection of heat…

Abstract

New four‐frequency tube inspection system. Hocking NDT has introduced Phasec D8, a new four channel multi‐frequency non‐destructive test system for the internal inspection of heat exchanger tubing in power stations, air conditioners and industrial processes.

Details

Anti-Corrosion Methods and Materials, vol. 33 no. 2
Type: Research Article
ISSN: 0003-5599

Book part
Publication date: 5 May 2017

Aditi D. Joshi and Surendra M. Gupta

In this chapter, a case of reverse supply chain is considered, where a product recovery facility receives sensors and Radio Frequency Identification (RFID) tags embedded…

Abstract

In this chapter, a case of reverse supply chain is considered, where a product recovery facility receives sensors and Radio Frequency Identification (RFID) tags embedded End-Of-Life (EOL) products. Sensors and RFID tags can capture and store component’s life cycle information during its economic life. This technology can provide data about contents and conditions of products and components without the need of actual disassembly and inspection. It also determines the remaining lives of the components which eventually translate into their quality levels.

The example considered here presents an advanced-repair-to-order-and-disassembly-to-order system. It disassembles the components to meet the components’ demands, repairs the products to meet the products’ demands and recycles the materials to meet the materials’ demands. The received EOL products may have different design alternatives. The objective of the proposed multi-criteria decision-making model is to determine which of the design alternatives is best in fulfilling the various criteria.

Details

Applications of Management Science
Type: Book
ISBN: 978-1-78714-282-4

Keywords

Article
Publication date: 1 October 1995

Gregory R. Doddrell

Today, information technology is fundamental to the operation ofmost businesses, whether they are small companies or multinationalcorporations. In recent times, the implementation…

1041

Abstract

Today, information technology is fundamental to the operation of most businesses, whether they are small companies or multinational corporations. In recent times, the implementation of local and wide area networks and the installation of computing equipment in office areas has brought information technology to nearly every working environment. The result is an increasing dependence on the availability, integrity and confidentiality of information stored and processed by these systems. As the trend shifts from “fortress” style central computer facilities to distributed systems located in generally less secure office environments, the risk of disruption increases, owing to lack of physical security, support services limitations and absence of site monitoring. The net result is higher business impact coupled with greater exposure. Identifies the elements that are at risk, discusses the issues businesses face when seeking to minimize exposures, suggests some practical solutions and describes some selected events that illustrate the hazards associated with having inadequate protection.

Details

Information Management & Computer Security, vol. 3 no. 4
Type: Research Article
ISSN: 0968-5227

Keywords

Article
Publication date: 18 January 2021

Jayati Athavale, Minami Yoda and Yogendra Joshi

This study aims to present development of genetic algorithm (GA)-based framework aimed at minimizing data center cooling energy consumption by optimizing the cooling set-points…

371

Abstract

Purpose

This study aims to present development of genetic algorithm (GA)-based framework aimed at minimizing data center cooling energy consumption by optimizing the cooling set-points while ensuring that thermal management criteria are satisfied.

Design/methodology/approach

Three key components of the developed framework include an artificial neural network-based model for rapid temperature prediction (Athavale et al., 2018a, 2019), a thermodynamic model for cooling energy estimation and GA-based optimization process. The static optimization framework informs the IT load distribution and cooling set-points in the data center room to simultaneously minimize cooling power consumption while maximizing IT load. The dynamic framework aims to minimize cooling power consumption in the data center during operation by determining most energy-efficient set-points for the cooling infrastructure while preventing temperature overshoots.

Findings

Results from static optimization framework indicate that among the three levels (room, rack and row) of IT load distribution granularity, Rack-level distribution consumes the least cooling power. A test case of 7.5 h implementing dynamic optimization demonstrated a reduction in cooling energy consumption between 21%–50% depending on current operation of data center.

Research limitations/implications

The temperature prediction model used being data-driven, is specific to the lab configuration considered in this study and cannot be directly applied to other scenarios. However, the overall framework can be generalized.

Practical implications

The developed framework can be implemented in data centers to optimize operation of cooling infrastructure and reduce energy consumption.

Originality/value

This paper presents a holistic framework for improving energy efficiency of data centers which is of critical value given the high (and increasing) energy consumption by these facilities.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 31 no. 10
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 26 August 2014

S. Sangiamsuk, B. Bubphachot, O. Watanabe and S. Rittidech

The purpose of this paper was to study the parameters affecting corrosion of the closed-loop oscillating heat-pipe with check valves (CLOHP/CV) in a system in clear that will be…

Abstract

Purpose

The purpose of this paper was to study the parameters affecting corrosion of the closed-loop oscillating heat-pipe with check valves (CLOHP/CV) in a system in clear that will be basic data to be used in future research. The majority of research focuses on the inner surface corrosion heat-pipe systems. The CLOHP/CV is commonly favored in cooling electronic devices, etc. Despite these common applications, limited reliable experimental research findings are available on the operation of the CLOHP/CV. Because of these reasons, the lack of detailed data, working fluids effect, working temperatures and duration of testing of the CLOHP/CV, this study focuses on determining the actual inner surface corrosion.

Design/methodology/approach

Seven types of copper tubes used in the CLOHP/CV set were sectioned to observe their inner surfaces. Seven different specimens with tube corrosion were examined by a visual inspection, scanning electron microscopy (SEM) and energy dispersive X-ray spectrometry (EDX). The technique for detecting metals solution in samples is based on the fact that ground state metals absorb light at specific wavelengths. Metal ions in a solution are converted to atomic state by means of a flame. In this study, concentration of copper particle in the working fluid was found by flame atomic absorption spectroscopy (Flame-AAS) and elements that occurred on inner surface tube were analyzed by EDX.

Findings

The analyses with SEM and EDX testing found that the character corrosion of inner surface of CLOHP/CV was pitting clearly. The analysis with Flame-AAS found that the concentration of copper particles in the distilled water and ethanol as working fluid is more than after 1,000 hours until 3,000 hours because of excess volume of oxygen in working fluid which causes many reactions at the beginning. When the oxygen decreases after 1,000 hours, it causes the reaction to decrease too and get the most concentration of copper particles, i.e. 18.57228 ppm or 0.40859 mg.

Originality/value

Corrosion-dependant maintenance must also be factored into the design. Producing reliable equipment that will become standardized and fixing the time for proper maintenance will require individuals that are knowledgeable about the materials that are going to be used in the design of such equipment. Nowadays, the lack of detailed data of working fluids effect, working temperatures and duration of testing of the CLOHP/CV focuses on determining the actual inner surface corrosion. Therefore, this research aimed to study the parameters affecting corrosion of the CLOHP/CV in a system in clear that will be basic data to be used in future research.

Details

Anti-Corrosion Methods and Materials, vol. 61 no. 5
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 6 February 2023

Nofirman Firdaus, Hasnida Ab-Samat and Bambang Teguh Prasetyo

This paper reviews the literature on maintenance strategies for energy efficiency as a potential maintenance approach. The purpose of this paper is to identify the main concept…

Abstract

Purpose

This paper reviews the literature on maintenance strategies for energy efficiency as a potential maintenance approach. The purpose of this paper is to identify the main concept and common principle for each maintenance strategy for energy efficiency.

Design/methodology/approach

A literature review has been carried out on maintenance and energy efficiency. The paper systematically classified the literature into three maintenance strategies (e.g. inspection-based maintenance [IBM], time-based maintenance [TBM] and condition-based maintenance [CBM]). The concept and principle of each maintenance strategy are identified, compared and discussed.

Findings

Each maintenance strategy's main concept and principle are identified based on the following criteria: data required and collection, data analysis/modeling and decision-making. IBM relies on human senses and common senses to detect energy faults. Any detected energy losses are quantified to energy cost. A payback period analysis is commonly used to justify corrective actions. On the other hand, CBM monitors relevant parameters that indicate energy performance indicators (EnPIs). Data analysis or deterioration modeling is needed to identify energy degradation. For the diagnostics approach, the energy degradation is compared with the threshold to justify corrective maintenance. The prognostics approach estimates when energy degradation reaches its threshold; therefore, proper maintenance tasks can be planned. On the other hand, TBM uses historical data from energy monitoring. Data analysis or deterioration modeling is required to identify degradation. Further analysis is performed to find the optimal time to perform a maintenance task. The comparison between housekeeping, IBM and CBM is also discussed and presented.

Practical implications

The literature on the classification of maintenance strategies for energy efficiency has been limited. On the other hand, the ISO 50001 energy management systems standard shows the importance of maintenance for energy efficiency (MFEE). Therefore, to bridge the gap between research and industry, the proposed concept and principle of maintenance strategies will be helpful for practitioners to apply maintenance strategies as energy conservation measures in implementing ISO 50001 standard.

Originality/value

The novelty of this paper is in-depth discussion on the concept and principle of each maintenance strategy (e.g. housekeeping or IBM, TBM and CBM) for energy efficiency. The relevant literature for each maintenance strategy was also summarized. In addition, basic rules for maintenance strategy selection are also proposed.

Details

Journal of Quality in Maintenance Engineering, vol. 29 no. 3
Type: Research Article
ISSN: 1355-2511

Keywords