Search results

1 – 2 of 2
Article
Publication date: 3 March 2023

Anxia Wan, Qianqian Huang, Ehsan Elahi and Benhong Peng

The study focuses on drug safety regulation capture, reveals the inner mechanism and evolutionary characteristics of drug safety regulation capture and provides suggestions for…

Abstract

Purpose

The study focuses on drug safety regulation capture, reveals the inner mechanism and evolutionary characteristics of drug safety regulation capture and provides suggestions for effective regulation by pharmacovigilance.

Design/methodology/approach

The article introduces prospect theory into the game strategy analysis of drug safety events, constructs a benefit perception matrix based on psychological perception and analyzes the risk selection strategies and constraints on stable outcomes for both drug companies and drug regulatory authorities. Moreover, simulation was used to analyze the choice of results of different parameters on the game strategy.

Findings

The results found that the system does not have a stable equilibrium strategy under the role of cognitive psychology. The risk transfer coefficient, penalty cost, risk loss, regulatory benefit, regulatory success probability and risk discount coefficient directly acted in the direction of system evolution toward the system stable strategy. There is a critical effect on the behavioral strategies of drug manufacturers and drug supervisors, which exceeds a certain intensity before the behavioral strategies in repeated games tend to stabilize.

Originality/value

In this article, the authors constructed the perceived benefit matrix through the prospect value function to analyze the behavioral evolution game strategies of drug companies and FDA in the regulatory process, and to evaluate the evolution law of each factor.

Details

Kybernetes, vol. 53 no. 5
Type: Research Article
ISSN: 0368-492X

Keywords

Article
Publication date: 17 April 2024

Rafiu King Raji, Yini Wei, Guiqiang Diao and Zilun Tang

Devices for step estimation are body-worn devices used to compute steps taken and/or distance covered by the user. Even though textiles or clothing are foremost to come to mind in…

Abstract

Purpose

Devices for step estimation are body-worn devices used to compute steps taken and/or distance covered by the user. Even though textiles or clothing are foremost to come to mind in terms of articles meant to be worn, their prominence among devices and systems meant for cadence is overshadowed by electronic products such as accelerometers, wristbands and smart phones. Athletes and sports enthusiasts using knee sleeves should be able to track their performances and monitor workout progress without the need to carry other devices with no direct sport utility, such as wristbands and wearable accelerometers. The purpose of this study thus is to contribute to the broad area of wearable devices for cadence application by developing a cheap but effective and efficient stride measurement system based on a knee sleeve.

Design/methodology/approach

A textile strain sensor is designed by weft knitting silver-plated nylon yarn together with nylon DTY and covered elastic yarn using a 1 × 1 rib structure. The area occupied by the silver-plated yarn within the structure served as the strain sensor. It worked such that, upon being subjected to stress, the electrical resistance of the sensor increases and in turn, is restored when the stress is removed. The strip with the sensor is knitted separately and subsequently sewn to the knee sleeve. The knee sleeve is then connected to a custom-made signal acquisition and processing system. A volunteer was employed for a wearer trial.

Findings

Experimental results establish that the number of strides taken by the wearer can easily be correlated to the knee flexion and extension cycles of the wearer. The number of peaks computed by the signal acquisition and processing system is therefore counted to represent stride per minute. Therefore, the sensor is able to effectively count the number of strides taken by the user per minute. The coefficient of variation of over-ground test results yielded 0.03%, and stair climbing also obtained 0.14%, an indication of very high sensor repeatability.

Research limitations/implications

The study was conducted using limited number of volunteers for the wearer trials.

Practical implications

By embedding textile piezoresistive sensors in some specific garments and or accessories, physical activity such as gait and its related data can be effectively measured.

Originality/value

To the best of our knowledge, this is the first application of piezoresistive sensing in the knee sleeve for stride estimation. Also, this study establishes that it is possible to attach (sew) already-knit textile strain sensors to apparel to effectuate smart functionality.

Details

International Journal of Clothing Science and Technology, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0955-6222

Keywords

1 – 2 of 2