Search results

1 – 10 of over 1000
Article
Publication date: 26 April 2024

Yansen Wu, Dongsheng Wen, Anmin Zhao, Haobo Liu and Ke Li

This study aims to study the thermal identification issue by harvesting both solar energy and atmospheric thermal updraft for a solar-powered unmanned aerial vehicle (SUAV) and…

Abstract

Purpose

This study aims to study the thermal identification issue by harvesting both solar energy and atmospheric thermal updraft for a solar-powered unmanned aerial vehicle (SUAV) and its electric energy performance under continuous soaring conditions.

Design/methodology/approach

The authors develop a specific dynamic model for SUAVs in both soaring and cruise modes. The support vector machine regression (SVMR) is adopted to estimate the thermal position, and it is combined with feedback control to implement the SUAV soaring in the updraft. Then, the optimal path model is built based on the graph theory considering the existence of several thermals distributed in the environment. The procedure is proposed to estimate the electricity cost of SUAV during flight as well as soaring, and making use of dynamic programming to maximize electric energy.

Findings

The simulation results present the integrated control method could allow SUAV to soar with the updraft. In addition, the proposed approach allows the SUAV to fly to the destination using distributed thermals while reducing the electric energy use.

Originality/value

Two simplified dynamic models are constructed for simulation considering there are different flight mode. Besides, the data-driven-based SVMR method is proposed to support SUAV soaring. Furthermore, instead of using length, the energy cost coefficient in optimization problem is set as electric power, which is more suitable for SUAV because its advantage is to transfer the three-dimensional path planning problem into the two-dimensional.

Details

Aircraft Engineering and Aerospace Technology, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 15 March 2024

Obed Ofori Yemoh, Richard Opoku, Gabriel Takyi, Ernest Kwadwo Adomako, Felix Uba and George Obeng

This study has assessed the thermal performance of locally fabricated bio-based building envelopes made of coconut and corn husk composite bricks to reduce building wall heat…

Abstract

Purpose

This study has assessed the thermal performance of locally fabricated bio-based building envelopes made of coconut and corn husk composite bricks to reduce building wall heat transmission load and energy consumption towards green building adaptation.

Design/methodology/approach

Samples of coconut fiber (coir) and corn husk fiber bricks were fabricated and tested for their thermophysical properties using the Transient Plane Source (TPS) 2500s instrument. A simulation was conducted using Dynamic Energy Response of Building - Lunds Tekniska Hogskola (DEROB-LTH) to determine indoor temperature variation over 24 h. The time lag and decrement factor, two important parameters in evaluating building envelopes, were also determined.

Findings

The time lag of the bio-based composite building envelope was found to be in the range of 4.2–4.6 h for 100 mm thickness block and 10.64–11.5 h for 200 mm thickness block. The decrement factor was also determined to be in the range of 0.87–0.88. The bio-based composite building envelopes were able to maintain the indoor temperature of the model from 25.4 to 27.4 °C, providing a closely stable indoor thermal comfort despite varying outdoor temperatures. The temperature variation in 24 h, was very stable for about 8 h before a degree increment, providing a comfortable indoor temperature for occupants and the need not to rely on air conditions and other mechanical forms of cooling. Potential energy savings also peaked at 529.14 kWh per year.

Practical implications

The findings of this study present opportunities to building developers and engineers in terms of selecting vernacular materials for building envelopes towards green building adaptation, energy savings, reduced construction costs and job creation.

Originality/value

This study presents for the first time, time lag and decrement factor for bio-based composite building envelopes for green building adaptation in hot climates, as found in Ghana.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Book part
Publication date: 5 June 2023

Harmeet Singh, Fatemeh Massah and Paul G. O'Brien

In this chapter the potential to use water-based Trombe walls to provide heated water for building applications during the summer months is investigated. Design Builder software…

Abstract

In this chapter the potential to use water-based Trombe walls to provide heated water for building applications during the summer months is investigated. Design Builder software is used to model a simple single-story building with a south-facing Trombe wall. The effects of using different thermal storage mediums within the Trombe wall on building heating loads during the winter and building cooling loads during the summer are modeled. The amount of thermal energy stored and temperature of water within the thermal storage medium during hot weather conditions were also simulated. On a sunny day on Toronto, Canada, the average temperature of the water in a Trombe wall integrated into a single-story building can reach ∼57°C, which is high enough to provide for the main hot water usages in buildings. Furthermore, the amount of water heated is three times greater than that required in an average household in Canada. The results from this work suggest that water-based Trombe walls have great potential to enhance the flexibility and utility of Trombe walls by providing heated water for building applications during summer months, without compromising performance during winter months.

Details

Pragmatic Engineering and Lifestyle
Type: Book
ISBN: 978-1-80262-997-2

Keywords

Article
Publication date: 27 December 2021

Elahe Mirabi and Fatemeh Akrami Abarghuie

The earth-sheltered building is an adaptive strategy reducing energy consumption as well as increasing thermal comfort of the residents. Although this idea historically…

Abstract

Purpose

The earth-sheltered building is an adaptive strategy reducing energy consumption as well as increasing thermal comfort of the residents. Although this idea historically implemented in the city of Yazd, Iran, its effects on thermal comfort have not been studied thoroughly. This paper aims to discuss and analyze energy performance, in terms of parameters such as orientation, underground depth, nocturnal ventilation and its subsequent effects on thermal comfort in earth-sheltered buildings in Yazd.

Design/methodology/approach

Using EnergyPlus software, the obtained numeric data are precisely modeled, simulated and analyzed.

Findings

Results show that there is a direct relationship between depth of construction and energy consumption savings. The more construction depth of earth-sheltered buildings, the more percentage of energy consumption savings, that is of a higher rate in comparison to the aboveground ones. However, in south orientation, energy saving significantly reduces from depth of 2 m downwards and the annual indoor temperature fluctuation decreases by 50%. This subsequently yields to experiencing indoor thermal comfort for a significant number of days throughout the year. Considering the effects of orientation factor, the south orientation regardless of the depth provides the most desired outcome regarding energy savings.

Originality/value

Simulating the model generalized to the sunken courtyard can approve that the results of this research can be applied to the other models.

Details

International Journal of Building Pathology and Adaptation, vol. 41 no. 5
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 24 October 2021

Anges Akim Aminou Moussavou, Ayokunle Oluwaseun Ayeleso, Marco Adonis and Atanda Raji

This paper aims to develop a selective energy optimisation of the photovoltaic–thermal (PV/T) system performance. The PV cell inside the PV/T system could be periodically…

Abstract

Purpose

This paper aims to develop a selective energy optimisation of the photovoltaic–thermal (PV/T) system performance. The PV cell inside the PV/T system could be periodically manipulated to produce domestic hot water without applying an external power supply.

Design/methodology/approach

A numerical simulation model of the proposed PV/T model was developed in MATLAB/Simulink to analyse the selective energy optimisation of the model. The extrinsic cell resistance (Rse) is adjusted to control the ratio of thermal to the electrical energy, generated from the PV cell inside the PV/T system. Therefore, the internal heat of the PV cell inside the PV/T system is periodically used as a thermal element to produce electrical power and hot water.

Findings

The optimisation of PV/T energy shows that the electrical power efficiency can increase by 11.6% when Rse was 0 Ω, and the 200 L water tank temperature increased by 22ºC when Rse was 50 Ω.

Originality/value

This study showed that the use of the PV cell could be extended to domestic hot water and space heating, and not only for electricity.

Details

Journal of Engineering, Design and Technology , vol. 21 no. 5
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 11 January 2024

Burak Kiyak, Hakan Fehmi Oztop and Ishak Gökhan Aksoy

The purpose of this study is to examine the effects of inclination angle on the thermal energy storage capability of a phase change material (PCM) within a disc-shaped container…

Abstract

Purpose

The purpose of this study is to examine the effects of inclination angle on the thermal energy storage capability of a phase change material (PCM) within a disc-shaped container. Different container materials are also tested such as plexiglass and aluminium. This study aims to assess the energy storage capacity, melting behaviour and temperature distributions of PCM with a specific melting range (22°C–26°C) for various governing parameters such as inclination angles, aspect ratios (AR) and temperature differences (ΔT) and compare the melting behaviour and energy storage performance of PCM in aluminium containers to those in plexiglass containers.

Design/methodology/approach

A finite volume approach was adopted to evaluate the thermal energy storage capability of PCMs. Five inclination angles ranging from 0° to 180° were considered and the energy storage capacity. Also, the melting behaviour of the PCM and temperature distributions of the container with different materials were tested. Two different AR and ΔT values were chosen as parameters to analyse for their effects on the melting performance of the PCM. Conjugate heat transfer problem is solved to see the effects of conduction mode of heat transfer.

Findings

The results of the study indicate that as AR decreases, the effect of the inclination angles on the energy storage capacity of the PCM decreases. For lower ΔT, the difference between the maximum and minimum stored energies was 20.88% for AR = 0.20, whereas it was 6.85% for AR = 0.15. Furthermore, under the same conditions, the PCM stored 8.02% more energy in plexiglass containers than in aluminium containers.

Originality/value

This study contributes to the understanding of the influence of inclination angle, container material, AR and ΔT on the thermal energy storage capabilities of PCM in a novel designed container. The findings highlight the importance of AR in mitigating the effect of the inclination angle on energy storage capacity. Additionally, comparing aluminium and plexiglass containers provides insights into the effect of container material on the melting behaviour and energy storage properties of PCM.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 34 no. 3
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 22 December 2023

Priyadharsini Sivaraj and Sivaraj Chinnasamy

This paper aims to examine the thermal transmission and entropy generation of hybrid nanofluid filled containers with solid body inside. The solid body is seen as being both…

Abstract

Purpose

This paper aims to examine the thermal transmission and entropy generation of hybrid nanofluid filled containers with solid body inside. The solid body is seen as being both isothermal and capable of producing heat. A time-dependent non-linear partial differential equation is used to represent the transfer of heat through a solid body. The current study’s objective is to investigate the key properties of nanoparticles, external forces and particular attention paid to the impact of hybrid nanoparticles on entropy formation. This investigation is useful for researchers studying in the area of cavity flows to know features of the flow structures and nature of hybrid nanofluid characteristics. In addition, a detailed entropy generation analysis has been performed to highlight possible regimes with minimal entropy generation rates. Hybrid nanofluid has been proven to have useful qualities, making it an attractive coolant for an electrical device. The findings would help scientists and engineers better understand how to analyse convective heat transmission and how to forecast better heat transfer rates in cutting-edge technological systems used in industries such as heat transportation, power generation, chemical production and passive cooling systems for electronic devices.

Design/methodology/approach

Thermal transmission and entropy generation of hybrid nanofluid are analysed within the enclosure. The domain of interest is a square chamber of size L, including a square solid block. The solid body is considered to be isothermal and generating heat. The flow driven by temperature gradient in the cavity is two-dimensional. The governing equations, formulated in dimensionless primitive variables with corresponding initial and boundary conditions, are worked out by using the finite volume technique with the SIMPLE algorithm on a uniformly staggered mesh. QUICK and central difference schemes were used to handle convective and diffusive elements. In-house code is developed using FORTRAN programming to visualize the isotherms, streamlines, heatlines and entropy contours, which are handled by Tecplot software. The influence of nanoparticles volume fraction, heat generation factor, external magnetic forces and an irreversibility ratio on energy transport and flow patterns is examined.

Findings

The results show that the hybrid nanoparticles concentration augments the thermal transmission and the entropy production increases also while the augmentation of temperature difference results in a diminution of entropy production. Finally, magnetic force has the significant impact on heat transfer, isotherms, streamlines and entropy. It has been observed that the external magnetic force plays a good role in thermal regulations.

Research limitations/implications

Hybrid nanofluid is a desirable coolant for an electrical device. Various nanoparticles and their combinations can be analysed. Ferro-copper hybrid nanofluid considered with the help of prevailing literature review. The research would benefit scientists and engineers by improving their comprehension of how to analyses convective heat transmission and forecast more accurate heat transfer rates in various fields.

Practical implications

Due to its helpful characteristics, ferrous-copper hybrid nanofluid is a desirable coolant for an electrical device. The research would benefit scientists and engineers by improving their comprehension of how to analyse convective heat transmission and forecast more accurate heat transfer rates in cutting-edge technological systems used in sectors like thermal transportation, cooling systems for electronic devices, etc.

Social implications

Entropy generation is used for an evaluation of the system’s performance, which is an indicator of optimal design. Hence, in recent times, it does a good engineering sense to draw attention to irreversibility under magnetic force, and it has an indispensable impact on investigation of electronic devices.

Originality/value

An efficient numerical technique has been developed to solve this problem. The originality of this work is to analyse convective energy transport and entropy generation in a chamber with internal block, which is capable of maintaining heat and producing heat. Effects of irreversibility ratio are scrutinized for the first time. Analysis of convective heat transfer and entropy production in an enclosure with internal isothermal/heat generating blocks gives the way to predict enhanced heat transfer rate and avoid the failure of advanced technical systems in industrial sectors.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 34 no. 2
Type: Research Article
ISSN: 0961-5539

Keywords

Open Access
Article
Publication date: 10 January 2023

Anna Trubetskaya, Olivia McDermott and Seamus McGovern

This article aims to optimise energy use and consumption by integrating Lean Six Sigma methodology with the ISO 50001 energy management system standard in an Irish dairy plant…

2873

Abstract

Purpose

This article aims to optimise energy use and consumption by integrating Lean Six Sigma methodology with the ISO 50001 energy management system standard in an Irish dairy plant operation.

Design/methodology/approach

This work utilised Lean Six Sigma methodology to identify methods to measure and optimise energy consumption. The authors use a single descriptive case study in an Irish dairy as the methodology to explain how DMAIC was applied to reduce energy consumption.

Findings

The replacement of heavy oil with liquid natural gas in combination with the new design of steam boilers led to a CO2 footprint reduction of almost 50%.

Practical implications

A further longitudinal study would be useful to measure and monitor the energy management system progress and carry out more case studies on LSS integration with energy management systems across the dairy industry.

Originality/value

The novelty of this study is the application of LSS in the dairy sector as an enabler of a greater energy-efficient facility, as well as the testing of the DMAIC approach to meet a key objective for ISO 50001 accreditation.

Details

The TQM Journal, vol. 35 no. 9
Type: Research Article
ISSN: 1754-2731

Keywords

Article
Publication date: 17 July 2023

Zahra Jalali, Asaad Y. Shamseldin and Sandeeka Mannakkara

Climate change reports from New Zealand claim that climate change will impact some cities such as Auckland from a heating-dominated to a cooling-dominated climate. The benefits…

Abstract

Purpose

Climate change reports from New Zealand claim that climate change will impact some cities such as Auckland from a heating-dominated to a cooling-dominated climate. The benefits and risks of climate change on buildings' thermal performance are still unknown. This paper examines the impacts of climate change on the energy performance of residential buildings in New Zealand and provides insight into changes in trends in energy consumption by quantifying the impacts of climate change.

Design/methodology/approach

The present paper used a downscaling method to generate weather data for three locations in New Zealand: Auckland, Wellington and Christchurch. The weather data sets were applied to the energy simulation of a residential case study as a reference building using a validated building energy analysis tool (EnergyPlus).

Findings

The result indicated that in Wellington and Christchurch, heating would be the major thermal load of residential buildings, while in Auckland, the main thermal load will change from heating to cooling in future years. The revised R-values for the building code will affect the pattern of dominant heating and cooling demands in buildings in Auckland in the future, while in Wellington and Christchurch, the heating load will be higher than the cooling load.

Originality/value

The findings of this study gave a broader insight into the risks and opportunities of climate change for the thermal performance of buildings. The results established the significance of considering climate change in energy performance analysis to inform the appropriate building codes for the design of residential buildings to avoid future costly changes to buildings.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 4 December 2023

Abdulbasit Almhafdy and Abdullah Mohammed Alsehail

This paper investigates the optimization of window design factors (WDFs) in hospital buildings, particularly in government hospitals within the arid climate of the Qassim region…

Abstract

Purpose

This paper investigates the optimization of window design factors (WDFs) in hospital buildings, particularly in government hospitals within the arid climate of the Qassim region, with the aim of achieving a better cooling load reduction. Continuous monitoring of the hospital ward section is crucial due to patients' needs, requiring optimal indoor air quality and cooling load.

Design/methodology/approach

The study identifies the optimal conditions for WDF design to mitigate cooling load, including window-to-wall ratio (WWR), window orientation (WO), room size and U-value (thermal properties), effectively reduce energy consumption in terms of sensible cooling load (MWh/m2) and comply with local codes. Data collection involved a smart weather station, while the Integrated Environmental Solution Virtual Environment (IESVE) software facilitated the simulation process.

Findings

Key findings reveal that larger patient rooms were about 40% more energy-efficient than smaller rooms. The northern orientation showed lower energy consumption, and specific WWRs and glazing U-values significantly affected energy loads. In an analysis of U-value changes in energy performance based on the Saudi Building Code (SBC), the presented values did not meet the minimum energy consumption standards. For a valid 40% WWR with a thermal permeability of 2.89, 0.181 MWh/m2 was consumed, while for an invalid 100% WWR with the same permeability but facing the north, 0.156 MWh/m2 was consumed, which is considered an invalid practice. It is vital to follow prescribed standards to ensure energy efficiency and avoid unnecessary costs.

Originality/value

Focus lies in emphasizing the significance of adhering to prescribed standards, such as SBC, to guarantee energy efficiency and prevent unwarranted expenses. Additionally, the authors highlight the crucial role of optimizing glazing properties and allocating the WWR appropriately to achieve energy-efficient building design, accounting for diverse orientations and climatic conditions.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

1 – 10 of over 1000