Search results

1 – 6 of 6
Article
Publication date: 28 June 2018

Haibo Feng, Yanwu Zhai and Yili Fu

Surgical robot systems have been used in single-port laparoscopy (SPL) surgery to improve patient outcomes. This study aims to develop a vision robot system for SPL surgery to…

Abstract

Purpose

Surgical robot systems have been used in single-port laparoscopy (SPL) surgery to improve patient outcomes. This study aims to develop a vision robot system for SPL surgery to effectively improve the visualization of surgical robot systems for relatively complex surgical procedures.

Design/methodology/approach

In this paper, a new master-slave magnetic anchoring vision robotic system for SPL surgery was proposed. A lighting distribution analysis for the imaging unit of the vision robot was carried out to guarantee illumination uniformity in the workspace during SPL surgery. Moreover, cleaning force for the lens of the camera was measured to assess safety for an abdominal wall, and performance assessment of the system was performed.

Findings

Extensive experimental results for illumination, control, cleaning force and functionality test have indicated that the proposed system has an excellent performance in providing the visual feedback.

Originality/value

The main contribution of this paper lies in the development of a magnetic anchoring vision robot system that successfully improves the ability of cleaning the lens and avoiding the blind area in a field of view.

Details

Industrial Robot: An International Journal, vol. 45 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 19 October 2015

Carlos Eduardo Díaz, Roemi Fernández, Manuel Armada and Felipe de Jesús García Gutiérrez

– This paper aims to provide an insight into recent advancements and developments of robotics for Natural Orifice Transluminal Surgery (NOTES) procedures.

Abstract

Purpose

This paper aims to provide an insight into recent advancements and developments of robotics for Natural Orifice Transluminal Surgery (NOTES) procedures.

Design/methodology/approach

Following an introduction that highlights the evolution from Minimally Invasive Surgery (MIS) to NOTES in the medical field, this paper reviews the main robotics systems that have been designed and implemented for MIS and NOTES, summarising their advantages and limitations and remarking the technological challenges and the requirements that still should be addressed and fulfilled.

Findings

The state-of-the-art presented in this paper shows that the majority of the platforms created for NOTES are laboratory prototypes, and their performances are still far from being optimal. New solutions are required to solve the problems confronted by the proposed systems such as the limited number of DOFs, the limited resolution, the optimal fixation and stiffening of the instruments for enabling stable and precise operation, the effective transmission of forces to the tip tools, the improvement of the force feedback feeling and the proper visualization and spatial orientation of the surgical field. Advances in robotics can contribute significantly to the development and future implementation of the NOTES procedure.

Originality/value

This paper highlights the current trends and challenges ahead in robotics applied to NOTES procedure.

Details

Industrial Robot: An International Journal, vol. 42 no. 6
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 8 September 2023

Fei Qi, Dongming Bai, Xiaoming Dou, Heng Zhang, Haishan Pei and Jing Zhu

This paper aims to present a kinematics analysis method and statics based control of the continuum robot with mortise and tenon joints to achieve better control performance of the…

Abstract

Purpose

This paper aims to present a kinematics analysis method and statics based control of the continuum robot with mortise and tenon joints to achieve better control performance of the robot.

Design/methodology/approach

The kinematics model is derived by the geometric analysis method under the piecewise constant curvature assumption, and the workspace and dexterity of the proposed robot are analyzed to optimize its structure parameters. Moreover, the statics model is established by the principle of virtual work, which is used to analyze the mapping relationship between the bending deformation and the applied forces/torques. To improve the control accuracy of the robot, a model-based controller is put forward.

Findings

Results of the experiments verify the feasibility of the proposed continuum structure and the correctness of the established model and the control method. The force deviation between the theoretical value and the actual value is relatively small, and the mean value of the deviation between the driving forces is only 0.46 N, which verify the established statics model and the controller.

Originality/value

The proposed model and motion controller can realize its accurate bending control with a few deviations, which can be used as the reference for the motion planning and dynamic model of the continuum robot.

Details

Industrial Robot: the international journal of robotics research and application, vol. 50 no. 6
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 30 April 2024

Yong Wang, Yuting Liu and Fan Xu

Soft robots are known for their excellent safe interaction ability and promising in surgical applications for their lower risks of damaging the surrounding organs when operating…

Abstract

Purpose

Soft robots are known for their excellent safe interaction ability and promising in surgical applications for their lower risks of damaging the surrounding organs when operating than their rigid counterparts. To explore the potential of soft robots in cardiac surgery, this paper aims to propose an adaptive iterative learning controller for tracking the irregular motion of the beating heart.

Design/methodology/approach

In continuous beating heart surgery, providing a relatively stable operating environment for the operator is crucial. It is highly necessary to use position-tracking technology to keep the target and the surgical manipulator as static as possible. To address the position tracking and control challenges associated with dynamic targets, with a focus on tracking the motion of the heart, control design work has been carried out. Considering the lag error introduced by the material properties of the soft surgical robotic arm and system delays, a controller design incorporating iterative learning control with parameter estimation was used for position control. The stability of the controller was analyzed and proven through the construction of a Lyapunov function, taking into account the unique characteristics of the soft robotic system.

Findings

The tracking performance of both the proportional-derivative (PD) position controller and the adaptive iterative learning controller are conducted on the simulated heart platform. The results of these two methods are compared and analyzed. The designed adaptive iterative learning control algorithm for position control at the end effector of the soft robotic system has demonstrated improved control precision and stability compared with traditional PD controllers. It exhibits effective compensation for periodic lag caused by system delays and material characteristics.

Originality/value

Tracking the beating heart, which undergoes quasi-periodic and complex motion with varying accelerations, poses a significant challenge even for rigid mechanical arms that can be precisely controlled and makes tracking targets located at the surface of the heart with the soft robot fraught with considerable difficulties. This paper originally proposes an adaptive interactive learning control algorithm to cope with the dynamic object tracking problem. The algorithm has theoretically proved its convergence and experimentally validated its performance at the cable-driven soft robot test bed.

Details

Robotic Intelligence and Automation, vol. 44 no. 3
Type: Research Article
ISSN: 2754-6969

Keywords

Article
Publication date: 16 May 2016

Shuntao Liu, Zhixiong Yang, Zhijun Zhu, Liangliang Han, Xiangyang Zhu and Kai Xu

Slim and dexterous manipulators with long reaches can perform various exploration and inspection tasks in confined spaces. This paper aims to present the development of such a…

Abstract

Purpose

Slim and dexterous manipulators with long reaches can perform various exploration and inspection tasks in confined spaces. This paper aims to present the development of such a dexterous continuum manipulator for potential applications in the aviation industry.

Design/methodology/approach

Benefiting from a newly conceived dual continuum mechanism and the improved actuation scheme, this paper proposes a design of a slim and dexterous continuum manipulator. Kinematics modeling, simulation-based dimension synthesis, structural constructions and system descriptions are elaborated.

Findings

Experimental validations show that the constructed prototype possesses the desired dexterity to navigate through confined spaces with its kinematics calibrated and actuation compensation implemented. The continuum manipulator with different deployed tools (e.g. graspers and welding guns) would be able to perform inspections and other tasks at remote locations in constrained environments.

Research limitations/implications

The current construction of the continuum manipulator possesses quite some friction inside its structure. The bending discrepancy caused by friction could accumulate to an obvious level. It is desired to further reduce the friction, even though the actuation compensation had been implemented.

Practical implications

The constructed continuum manipulator could perform inspection and other tasks in confined spaces, acting as an active multi-functional endoscopic platform. Such a device could greatly facilitate routine tasks in the aviation industry, such as guided assembling, inspection and maintenance.

Originality/value

The originality and values of this paper mainly lay on the design, modeling, construction and experimental validations of the slim and dexterous continuum manipulator for the desired mobility and functionality in confined spaces.

Details

Industrial Robot: An International Journal, vol. 43 no. 3
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 6 June 2019

Hao Wang, GuoHua Gao, Qixiao Xia, Han Ren, LianShi Li and Yuhang Zheng

The purpose of this paper is to present a novel stretch-retractable single section (SRSS) continuum manipulator which owns three degrees of freedom and higher motion range in…

Abstract

Purpose

The purpose of this paper is to present a novel stretch-retractable single section (SRSS) continuum manipulator which owns three degrees of freedom and higher motion range in three-dimension workspace than regular single continuum manipulator. Moreover, the motion accuracy was analyzed based on the kinematic model. In addition, the experiments were carried out for validation of the theory.

Design/methodology/approach

A kinematics model of the SRSS continuum manipulator is presented for analysis on bending, rotating and retracting in its workspace. To discuss the motion accuracy of the SRSS continuum manipulator, the dexterity theory was introduced based on the decomposing of the Jacobian matrix. In addition, the accuracy of motion is estimated based on the inverse kinematics and dexterity theory. To verify the presented theory, the motion of free end was tracked by an electromagnetic positioning system. According to the comparison of experimental value and theoretical analysis, the free end error of SRSS continuum manipulator is less than 6.24 per cent in the region with favorable dexterity.

Findings

This paper presents a new stretch-retractable continuum manipulator that the structure was composed of several springs as the backbone. Thus, the SRSS continuum manipulator could own wide motion range depending on its retractable structure. Then, the motion accuracy character of the SRSS continuum manipulator in the different regions of its workspace was obtained both theoretically and experimentally. The results show that the high accuracy region distributes in the vicinity of the outer boundary of the workspace. The motion accuracy gradually decreases with the motion position approaching to the center of its workspace.

Research limitations/implications

The presented SRSS continuum manipulator owns three degrees of freedom. The future work would be focused on the two-section structure which will own six degrees of freedom.

Practical implications

In this study, the SRSS continuum manipulator could be extended to six degrees of freedom continuum robot with two sections that is less one section than regular six degrees of freedom with three single section continuum manipulator.

Originality/value

The value of this study is to propose a SRSS continuum manipulator which owns three degrees of freedom and could stretch and retract to expend workspace, for which the accuracy in different regions of the workspace was analyzed and validated based on the kinematics model and experiments. The results could be feasible to plan the motion space of the SRSS continuum manipulator for keeping in suitable accuracy region.

Details

Industrial Robot: the international journal of robotics research and application, vol. 46 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

1 – 6 of 6