Search results

1 – 10 of 794
Article
Publication date: 1 January 2024

Xingxing Li, Shixi You, Zengchang Fan, Guangjun Li and Li Fu

This review provides an overview of recent advances in electrochemical sensors for analyte detection in saliva, highlighting their potential applications in diagnostics and health…

Abstract

Purpose

This review provides an overview of recent advances in electrochemical sensors for analyte detection in saliva, highlighting their potential applications in diagnostics and health care. The purpose of this paper is to summarize the current state of the field, identify challenges and limitations and discuss future prospects for the development of saliva-based electrochemical sensors.

Design/methodology/approach

The paper reviews relevant literature and research articles to examine the latest developments in electrochemical sensing technologies for saliva analysis. It explores the use of various electrode materials, including carbon nanomaterial, metal nanoparticles and conducting polymers, as well as the integration of microfluidics, lab-on-a-chip (LOC) devices and wearable/implantable technologies. The design and fabrication methodologies used in these sensors are discussed, along with sample preparation techniques and biorecognition elements for enhancing sensor performance.

Findings

Electrochemical sensors for salivary analyte detection have demonstrated excellent potential for noninvasive, rapid and cost-effective diagnostics. Recent advancements have resulted in improved sensor selectivity, stability, sensitivity and compatibility with complex saliva samples. Integration with microfluidics and LOC technologies has shown promise in enhancing sensor efficiency and accuracy. In addition, wearable and implantable sensors enable continuous, real-time monitoring of salivary analytes, opening new avenues for personalized health care and disease management.

Originality/value

This review presents an up-to-date overview of electrochemical sensors for analyte detection in saliva, offering insights into their design, fabrication and performance. It highlights the originality and value of integrating electrochemical sensing with microfluidics, wearable/implantable technologies and point-of-care testing platforms. The review also identifies challenges and limitations, such as interference from other saliva components and the need for improved stability and reproducibility. Future prospects include the development of novel microfluidic devices, advanced materials and user-friendly diagnostic devices to unlock the full potential of saliva-based electrochemical sensing in clinical practice.

Details

Sensor Review, vol. 44 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 2 May 2024

Chengxiong Lin and Wenming Wu

This paper aims to introduce a custom-designed integrated nucleic acid detection polymerase chain reaction (PCR) instrument for clinical detection applications.

Abstract

Purpose

This paper aims to introduce a custom-designed integrated nucleic acid detection polymerase chain reaction (PCR) instrument for clinical detection applications.

Design/methodology/approach

The PCR instrument can make rapid, sensitive, low-cost and quantitative molecular diagnosis compared with the current routine test flow from the pipette, series reagent to RT-PCR by manual manipulation. By integrating the multichannel automatic pipetting module, heat amplification module and real-time fluorescence detection module for the first time, the custom-designed integrated nucleic acid detection PCR instrument can achieve sample collection, subpackage, mixing, extracting, measuring and result presentation.

Findings

The multichannel automatic pipetting module was assembled with an accuracy of 0.4% (2 microliters) for accuracy measurement. Besides, the accuracy and sensitivity of nucleic acid using integrated low-cost nucleic acid detection PCR instruments were checked with COV-2019 virus (staining method) and African swine fever virus (probe method) under different concentrations.

Practical implications

Because of its high cost, complex system and bulky laboratory settings, including sample subpackage, mixing, extracting, measuring and finally result in presentation, the current nucleic acid detection system is not suitable for field operation and disease diagnosis in remote areas. The group independently designed and assembled an integrated low-cost multichannel nucleic acid detection PCR instrument, including a multichannel automatic pipetting module, a heat amplification module and a real-time fluorescence detection module.

Originality/value

The above equipment showed better reliability compared with commercial qPCR. These results can lay the foundation for functional, fast and low-cost PCR equipment for trace measurements.

Details

Sensor Review, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 21 November 2023

Lochan Singh and Vijay Singh Sharanagat

Nature and occurrence of food-borne pathogens in raw and processed food products evolved greatly in the past few years due to new modes of transmission and resistance build-up…

155

Abstract

Purpose

Nature and occurrence of food-borne pathogens in raw and processed food products evolved greatly in the past few years due to new modes of transmission and resistance build-up against sundry micro-/macro-environmental conditions. Assurance of food health and safety thus gained immense importance, for which bio-sensing technology proved very promising in the detection and quantification of food-borne pathogens. Considering the importance, different studies have been performed, and different biosensors have been developed. This study aims to summarize the different biosensors used for the deduction of food-borne pathogens.

Design/methodology/approach

The present review highlights different biosensors developed apropos to food matrices, factors governing their selection, their potential and applicability. The paper discusses some related key challenges and constraints and also focuses on the needs and future research prospects in this field.

Findings

The shift in consumers’ and industries’ perceptions directed the further approach to achieve portable, user and environmental friendly biosensing techniques. Despite of these developments, it was still observed that the comparison among the different biosensors and their categories proved tedious on a single platform; since the food matrices tested, pathogen detected or diagnosed, time of detection, etc., varied greatly and very few products have been commercially launched. Conclusively, a challenge lies in front of food scientists and researchers to maintain pace and develop techniques for efficiently catering to the needs of the food industry.

Research limitations/implications

Biosensors deduction limit varied with the food matrix, type of organism, material of biosensors’ surface, etc. The food matrix itself consists of complex substances, and various types of food are available in nature. Considering the diversity of food there is a need to develop a universal biosensor that can be used for all the food matrices for a pathogen. Further research is needed to develop a pathogen-specific biosensor that can be used for all the food products that may have accuracy to eliminate the traditional method of deduction.

Originality/value

The present paper summarized and categorized the different types of biosensors developed for food-borne pathogens.

Graphical abstract

Details

Nutrition & Food Science , vol. 54 no. 1
Type: Research Article
ISSN: 0034-6659

Keywords

Article
Publication date: 3 November 2022

Glory George-Ufot, JiuChang Wei, Oyinkansola Christiana Kevin-Israel, Mona Salim, Muhideen Sayibu, Halima Habuba Mohamed and Lincoln Jisuvei Sungu

This study explored whether the critical incident management systems (CIMS) model can predict the EMS performance in the COVID-19 context. Past research has established the…

Abstract

Purpose

This study explored whether the critical incident management systems (CIMS) model can predict the EMS performance in the COVID-19 context. Past research has established the significance of early detection and response (ER) in the context of Ebola virus disease (EVD), prompting a question of whether the model can also be helpful in the COVID-19 context. Consequently, the authors assessed whether ER influences the impact of communication capacity (CC), reliable information channel (RC) and environment (EN) on COVID-19 EMS performance. Assessing these relationships will advance emerging infectious disease (EID) preparedness.

Design/methodology/approach

The authors employed standardized measurement instruments of the CIMS model (CC, ER, RC and EN) to predict the performance of COVID-19 EMS using structural equation modeling (SEM) in a study of 313 participants from frontline responders.

Findings

The results show that the relationship of ER and EN with COVID-19 EMS performance is positive, while that of EN on CC is negative. The relationship between EN and COVID-19 EMS performance was insignificant. Contrary to the hypothesis, CC was negatively significant to COVID-19 EMS performance due to poor communication capacities.

Research limitations/implications

The authors acknowledge some limitations due to challenges faced in this study. First, Data collection was a significant limitation as these questionnaires were built and distributed in June 2020, but the response time was prolonged due to the recurring nature of the pandemic. The authors had wanted to implore the inputs of all stakeholders, and efforts were made to reach out to various Ministry of Health, the local CDC and related agencies in the region via repeated emails explaining the purpose of the study to no avail. The study finally used the frontline workers as the respondents. The authors used international students from various countries as the representatives to reach out to their countries' frontline workers. Second, since the study was only partially supported using the CIMS model, future studies may combine the CIMS model with other models or theories. Subsequent research reassesses this outcome in other contexts or regions. Consequently, further research can explore how CC can be improved with COVID-19 and another future EID in the region. This may improve the COVID-19 EMS performance, thereby expanding the lesson learned from the pandemic and sustaining public health EID response. Additionally, other authors may combine the CIMS model with other emergency management models or theories to establish a fully supported theoretical model in the context of COVID-19.

Practical implications

The findings have practical implications for incident managers, local CDCs, governments, international organizations and scholars. The outcome of the study might inform these stakeholders on future direction and contribution to EID preparedness. This study unfolds the impact of lessons learned in the region demonstrated by moderating early detection and responses with other constructs to achieve COVID-19 EMS performance. The findings reveal that countries that experienced the 2013–2016 Ebola outbreak, were not necessarily more prepared for an epidemic or pandemic, judging by the negative moderating impact of early detection and response. However, these experiences provide a foundation for the fight against COVID-19. There is a need for localized plans tailored to each country's situation, resources, culture and lifestyle. The localized plan will be to mitigate and prevent an unsustainable EID management system, post-epidemic fund withdrawals and governance. This plan might be more adaptable and sustainable for the local health system when international interventions are withdrawn after an epidemic. Public health EID plans must be adapted to each country's unique situation to ensure sustainability and constantly improve EID management of epidemics and pandemics in emergency response. The high to moderate importation risk in African countries shows Africa's largest window of vulnerability to be West Africa (Gilbert et al., 2020). Therefore, they should be in the spotlight for heightened assistance towards the preparedness and response for a future pandemic like COVID-19. The West African region has a low capacity to manage the health emergency to match the population capacities. The COVID-19 outbreak in West Africa undoubtedly inflicted many disruptions in most countries' economic, social and environmental circumstances. The region's unique challenges observed in this study with CC and reliable information channels as being negatively significant highlight the poor maintenance culture and weak institutions due to brain drain and inadequate training and monitoring. This outcome practically informs West African stakeholders and governments on aspects to indulge when trying to improve emergency preparedness as the outcomes from other regions might not be applicable.

Originality/value

This study explored the relevance of the CIMS model in the context of the COVID-19 pandemic, revealing different patterns of influence on COVID-19 EMS performance. In contrast to the extant literature on EVD, the authors found the moderating effects of ER in the COVID-19 context. Thus, the authors contribute to the COVID-19 EMS performance domain by developing a context-driven EMS model. The authors discuss the theoretical and practical implications.

Details

Information Technology & People, vol. 36 no. 7
Type: Research Article
ISSN: 0959-3845

Keywords

Article
Publication date: 29 August 2023

Shakiba Narjabadi Fam and Ramona Massoud

Food safety is among the most important topics in the world. According to WHO guidelines, aflatoxins are one of the most hazardous food toxins. Therefore, their detection in food…

Abstract

Purpose

Food safety is among the most important topics in the world. According to WHO guidelines, aflatoxins are one of the most hazardous food toxins. Therefore, their detection in food products seems crucial due to health problems. The purpose of this paper is to discuss the different types of biosensors in aflatoxin determination.

Design/methodology/approach

Traditional detection methods are time consuming and expensive. As fast and accurate detection is important in monitoring food contaminants, alternative analytical methods would be essential. Biosensors are the intelligent design of sensitive sensors for precise detection of toxins in a short time. Various biosensors are being applied for aflatoxins detection in food products with many advantages over the traditional methods.

Findings

Biosensors are cost-effective, stable and have possessed high selectivity, specificity and accuracy in aflatoxins detection. Applying biosensors has been increased recently, so biosensing methods (optical, electrochemical, piezoelectrical, immunosensors, surface plasmon resonance and calorimetric) are discussed along with their advantages in this article.

Research limitations/implications

More efforts should be occurred to detect and decrease the aflatoxins by biosensors, and some traits like accuracy and selectivity would be the purpose of future projects. The combination of various techniques would also help in toxin detection issue in food products, so high efforts in this regard are also required for the upcoming years.

Originality/value

This article also reviews different types of biosensors simultaneously and explains their specificity for aflatoxin determination in different food products and also the future trends and requirements.

Details

Nutrition & Food Science , vol. 53 no. 8
Type: Research Article
ISSN: 0034-6659

Keywords

Open Access
Article
Publication date: 25 December 2023

Jiahe Wang, Huajian Li, Chengxian Ma, Chaoxun Cai, Zhonglai Yi and Jiaxuan Wang

This study aims to analyze the factors, evaluation techniques of the durability of existing railway engineering.

Abstract

Purpose

This study aims to analyze the factors, evaluation techniques of the durability of existing railway engineering.

Design/methodology/approach

China has built a railway network of over 150,000 km. Ensuring the safety of the existing railway engineering is of great significance for maintaining normal railway operation order. However, railway engineering is a strip structure that crosses multiple complex environments. And railway engineering will withstand high-frequency impact loads from trains. The above factors have led to differences in the deterioration characteristics and maintenance strategies of railway engineering compared to conventional concrete structures. Therefore, it is very important to analyze the key factors that affect the durability of railway structures and propose technologies for durability evaluation.

Findings

The factors that affect the durability and reliability of railway engineering are mainly divided into three categories: material factors, environmental factors and load factors. Among them, material factors also include influencing factors, such as raw materials, mix proportions and so on. Environmental factors vary depending on the service environment of railway engineering, and the durability and deterioration of concrete have different failure mechanisms. Load factors include static load and train dynamic load. The on-site rapid detection methods for five common diseases in railway engineering are also proposed in this paper. These methods can quickly evaluate the durability of existing railway engineering concrete.

Originality/value

The research can provide some new evaluation techniques and methods for the durability of existing railway engineering.

Details

Railway Sciences, vol. 3 no. 1
Type: Research Article
ISSN: 2755-0907

Keywords

Article
Publication date: 23 April 2024

Xiaotong Zhang and Qiu Zhang

The purpose of this study is to develop a molecular imprinting electrochemical sensor for the specific detection of the anticancer drug amsacrine. The sensor used a composite of…

Abstract

Purpose

The purpose of this study is to develop a molecular imprinting electrochemical sensor for the specific detection of the anticancer drug amsacrine. The sensor used a composite of bacterial cellulose (BC) and silver nanoparticles (AgNPs) as a platform for the immobilization of a molecularly imprinted polymer (MIP) film. The main objective was to enhance the electrochemical properties of the sensor and achieve a high level of selectivity and sensitivity toward amsacrine molecules in complex biological samples.

Design/methodology/approach

The composite of BC-AgNPs was synthesized and characterized using FTIR, XRD and SEM techniques. The MIP film was molecularly imprinted to selectively bind amsacrine molecules. Electrochemical characterization, including cyclic voltammetry and electrochemical impedance spectroscopy, was performed to evaluate the modified electrode’s conductivity and electron transfer compared to the bare glassy carbon electrode (GCE). Differential pulse voltammetry was used for quantitative detection of amsacrine in the concentration range of 30–110 µM.

Findings

The developed molecular imprinting electrochemical sensor demonstrated significant improvements in conductivity and electron transfer compared to the bare GCE. The sensor exhibited a linear response to amsacrine concentrations between 30 and 110 µM, with a low limit of detection of 1.51 µM. The electrochemical response of the sensor showed remarkable changes before and after amsacrine binding, indicating the successful imprinting of amsacrine in the MIP film. The sensor displayed excellent selectivity for amsacrine in the presence of interfering substances, and it exhibited good stability and reproducibility.

Originality/value

This study presents a novel molecular imprinting electrochemical sensor design using a composite of BC and AgNPs as a platform for MIP film immobilization. The incorporation of BC-AgNPs improved the sensor’s electrochemical properties, leading to enhanced sensitivity and selectivity for amsacrine detection. The successful imprinting of amsacrine in the MIP film contributes to the sensor's specificity. The sensor's ability to detect amsacrine in a concentration range relevant to anticancer therapy and its excellent performance in complex sample matrices add significant value to the field of electrochemical sensing for pharmaceutical analysis.

Details

Sensor Review, vol. 44 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 16 October 2023

Reetu Yadav, Mamta Kushwah, Anna Nikolaevna Berlina and Mulayam Singh Gaur

The purpose of this study is determination of cadmium using silver-gold bimetallic nanoparticles (Ag-Au BMNPs) and an aptamer modified glassy carbon electrode.

Abstract

Purpose

The purpose of this study is determination of cadmium using silver-gold bimetallic nanoparticles (Ag-Au BMNPs) and an aptamer modified glassy carbon electrode.

Design/methodology/approach

The maximum response of modified electrode was obtained with, 50 mV pulse amplitude, 20 mV/s scan rate in phosphate buffer of pH 4.0. Ag-Au BMNPs, as the mediators improved electron transmit during the entire electron transfer process and the aptasensor response. Herein, the authors used aptamer as the capture probe to prepare an aptasensor with enhanced stability.

Findings

The proposed aptasensor exhibited a wide linearity to cadmium in the range of 0.001–0.100 µg/L with a low detection limit of 0.005×10−3 µg/L. The glassy carbon electrodes with Ag-Au BMNPs showed a lower detection limit.

Originality/value

This aptasensor has good reproducibility, stability and repeatability and is cost-effective to regenerate. The specificity and selectivity of the novel modified electrode is tested in the presence of other interfering metal ions such as Fe2+, Mn2+, Mg2+, Sb3+ and Bi3+. The aptasensor shows 10 times more sensitivity and selectivity for Cd2+ ions.

Details

Sensor Review, vol. 43 no. 5/6
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 16 February 2022

Pragati Agarwal, Sanjeev Swami and Sunita Kumari Malhotra

The purpose of this paper is to give an overview of artificial intelligence (AI) and other AI-enabled technologies and to describe how COVID-19 affects various industries such as…

3620

Abstract

Purpose

The purpose of this paper is to give an overview of artificial intelligence (AI) and other AI-enabled technologies and to describe how COVID-19 affects various industries such as health care, manufacturing, retail, food services, education, media and entertainment, banking and insurance, travel and tourism. Furthermore, the authors discuss the tactics in which information technology is used to implement business strategies to transform businesses and to incentivise the implementation of these technologies in current or future emergency situations.

Design/methodology/approach

The review provides the rapidly growing literature on the use of smart technology during the current COVID-19 pandemic.

Findings

The 127 empirical articles the authors have identified suggest that 39 forms of smart technologies have been used, ranging from artificial intelligence to computer vision technology. Eight different industries have been identified that are using these technologies, primarily food services and manufacturing. Further, the authors list 40 generalised types of activities that are involved including providing health services, data analysis and communication. To prevent the spread of illness, robots with artificial intelligence are being used to examine patients and give drugs to them. The online execution of teaching practices and simulators have replaced the classroom mode of teaching due to the epidemic. The AI-based Blue-dot algorithm aids in the detection of early warning indications. The AI model detects a patient in respiratory distress based on face detection, face recognition, facial action unit detection, expression recognition, posture, extremity movement analysis, visitation frequency detection, sound pressure detection and light level detection. The above and various other applications are listed throughout the paper.

Research limitations/implications

Research is largely delimited to the area of COVID-19-related studies. Also, bias of selective assessment may be present. In Indian context, advanced technology is yet to be harnessed to its full extent. Also, educational system is yet to be upgraded to add these technologies potential benefits on wider basis.

Practical implications

First, leveraging of insights across various industry sectors to battle the global threat, and smart technology is one of the key takeaways in this field. Second, an integrated framework is recommended for policy making in this area. Lastly, the authors recommend that an internet-based repository should be developed, keeping all the ideas, databases, best practices, dashboard and real-time statistical data.

Originality/value

As the COVID-19 is a relatively recent phenomenon, such a comprehensive review does not exist in the extant literature to the best of the authors’ knowledge. The review is rapidly emerging literature on smart technology use during the current COVID-19 pandemic.

Details

Journal of Science and Technology Policy Management, vol. 15 no. 3
Type: Research Article
ISSN: 2053-4620

Keywords

Article
Publication date: 30 August 2022

Zhao Xu, Yangze Liang, Hongyu Lu, Wenshuo Kong and Gang Wu

Construction schedule delays and quality problems caused by construction errors are common in the field of prefabricated buildings. The effective monitoring of the construction…

Abstract

Purpose

Construction schedule delays and quality problems caused by construction errors are common in the field of prefabricated buildings. The effective monitoring of the construction project process is one of the key factors for the success of a project. How to effectively monitor the construction process of prefabricated building construction projects is an urgent problem to be solved. Aiming at the problems existing in the monitoring of the construction process of prefabricated buildings, this paper proposes a monitoring method based on the feature extraction of point cloud model.

Design/methodology/approach

This paper uses Trimble X7 3D laser scanner to complete field data collection experiments. The point cloud data are preprocessed, and the prefabricated component segmentation and geometric feature measurement are completed based on the PCL platform. Aiming at the problem of noisy points and large amount of data in the original point cloud data, the preprocessing is completed through the steps of constructing topological relations, thinning, and denoising. According to the spatial position relationship and geometric characteristics of prefabricated frame structure, the segmentation algorithm flow is designed in this paper. By processing the point cloud data of single column and beam members, the quality of precast column and beam members is measured. The as-built model and as-designed model are compared to realize the visual monitoring of construction progress.

Findings

The experimental results show that the dimensional measurement accuracy of beam and column proposed in this paper is more than 95%. This method can effectively detect the quality of prefabricated components. In the aspect of progress monitoring, the visualization of real-time progress monitoring is realized.

Originality/value

This paper proposed a new monitoring method based on feature extraction of the point cloud model, combined with three-dimensional laser scanning technology. This method allows for accurate monitoring of the construction process, rapid detection of construction information, and timely detection of construction quality errors and progress delays. The treatment process based on point cloud data has strong applicability, and the real-time point cloud data transfer treatment can guarantee the timeliness of monitoring.

Details

Engineering, Construction and Architectural Management, vol. 30 no. 10
Type: Research Article
ISSN: 0969-9988

Keywords

1 – 10 of 794