Search results

1 – 10 of 116
Article
Publication date: 29 August 2023

Erik Velasco and Elvagris Segovia

Waiting for a bus may represent a period of intense exposure to traffic particles in hot and noisy conditions in the street. To lessen the particle load and tackle heat in bus…

Abstract

Purpose

Waiting for a bus may represent a period of intense exposure to traffic particles in hot and noisy conditions in the street. To lessen the particle load and tackle heat in bus stops a shelter was equipped with an electrostatic precipitator and a three-step adiabatic cooling system capable of dynamically adjust its operation according to actual conditions. This study evaluates the effectiveness of the Airbitat Oasis Smart Bus Stop, as the shelter was called, to provide clean and cool air.

Design/methodology/approach

The particle exposure experienced in this innovative shelter was contrasted with that in a conventional shelter located right next to it. Mass concentrations of fine particles and black carbon, and particle number concentration (as a proxy of ultrafine particles) were simultaneously measured in both shelters. Air temperature, relative humidity and noise level were also measured.

Findings

The new shelter did not perform as expected. It only slightly reduced the abundance of fine particles (−6.5%), but not of ultrafine particles and black carbon. Similarly, it reduced air temperature (−1 °C), but increased relative humidity (3%). Its operation did not generate additional noise.

Practical implications

The shelter's poor performance was presumably due to design flaws induced by a lack of knowledge on traffic particles and fluid dynamics in urban environments. This is an example where harnessing technology without understanding the problem to solve does not work.

Originality/value

It is uncommon to come across case studies like this one in which the performance and effectiveness of urban infrastructure can be assessed under real-life service settings.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 25 May 2023

Mohammed Alhaji Mohammed, Kyari Bulama, Alhaji Modu Bukar, Mala Ali Modu, Audu Alhaji Usman, Alhaji Kasir Lawan and Garba Abba Habib

The effects of dust exposure in buildings and its health and comfort consequences continue to concern occupants, particularly those who spend most of their time indoors. This…

Abstract

Purpose

The effects of dust exposure in buildings and its health and comfort consequences continue to concern occupants, particularly those who spend most of their time indoors. This study examines the influence of building opening characteristics on surface dust loading in indoor environments to determine the dust particles' impact on different opening configurations.

Design/methodology/approach

Indoor Harmattan dust surface loading data were collected from Maiduguri, Northeastern Nigeria, using model rooms with six different window configurations. A simple mathematical relationship was employed to assess surface dust loading characteristics in the model rooms. The study measured dust thrice between December and February for three days (72 h). The results were analyzed using descriptive statistics.

Findings

The results determined the highest average surface dust loading of 12.03 g/m2 in the room with awning windows at an indoor-to-outdoor (I/O) ratio of 0.7. In contrast, the experiment in the room with a closed window recorded the lowest average surface dust loading of 5.24 g/m2 at an I/O ratio of 0.30, which is infiltration. The outcomes further indicate that the average surface dust loading varies with the building opening type and position, as higher surface dust loadings were recorded in locations closer to the openings (doors and windows), reaffirming that the dominant source of the dust particles is outdoors. According to the study, dust incursion due to infiltration accounts for 30% of the outdoor surface loading.

Originality/value

Thus, Harmattan dust is a serious challenge to the health, productivity and hygiene of building occupants in the study area. The built-environment professionals must use the study's outcome to optimize building openings' designs (shape, size and form) for effective indoor dust control.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 20 April 2023

Fatemeh Goodarzi, Kavitha Palaniappan, Manikam Pillay and Mahmoud Ershadi

Exposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness…

Abstract

Purpose

Exposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness without amendment of ventilation, or the use of building materials such as glue, paint, thinner and varnishes. Recent studies have been conducted to measure indoor air pollutants and assess the health risks affecting the quality of life, productivity and well-being of human beings. However, limited review studies have been recently conducted to provide an overview of the state of knowledge. This study aims to conduct a scoping review of indoor air quality (IAQ) in the context of refurbished or energy-retrofitted buildings.

Design/methodology/approach

A systematic screening process based on the PRISMA protocol was followed to extract relevant articles. Web of Science, Scopus, Google Scholar and PubMed were searched using customised search formulas. Among 276 potentially relevant records, 38 studies were included in the final review covering a period from 2015 to 2022.

Findings

Researchers mapped out the measured compounds in the selected studies and found that carbon dioxide (CO2) (11%) and total volatile organic compounds (11%) were among the most commonly measured contaminants. Two trends of research were found including (1) the impact of ventilative properties on IAQ and (2) the impact of introducing building materials on IAQ.

Originality/value

The contribution of this study lies in summarising evidence on IAQ measurements in refurbished buildings, discussing recent advancements, revealing significant gaps and limitations, identifying the trends of research and drawing conclusions regarding future research directions on the topic.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 29 September 2023

Li Wang, Yanhong Lv, Tao Wang, Shuting Wan and Yanling Ye

The purpose of this research is to address the existing gap in the study of construction and demolition waste (C&DW) by focusing on its impact on human health throughout the…

Abstract

Purpose

The purpose of this research is to address the existing gap in the study of construction and demolition waste (C&DW) by focusing on its impact on human health throughout the entire life cycle. And this research provides a comprehensive assessment model that incorporates the release of gaseous pollutants and particulate matter during the whole life cycle of C&DW, thereby contributing to a more holistic understanding of its impact on human health.

Design/methodology/approach

The research was conducted in two stages. Firstly, the quantitative model framework of pollutants emitted by C&DW was established. Three types of pollutants were considered, namely nitrogen dioxide (NO2), sulfur dioxide (SO2) and inhalable particulate matter (PM10). Second, disability-adjusted life year (DALY) and willingness to pay (WTP) assessments were used to provide a monetary quantified health impact for pollutants released by C&DW.

Findings

The results show that the WTP value of PM10 is the highest among all pollutants and 8.68E+07 dollars/a, while the WTP value in the disposal stage accounts for the largest proportion compared to the generation and transportation stage. These findings emphasize the importance of PM10 and C&DW treatment stage for pollutant treatment.

Originality/value

The results of this study are of great significance for the management department to optimize the construction management scheme to reduce the total amount of pollutants produced by C&DW and its harm to human health. Meanwhile, this study fills the gap in existing research on the impact assessment of C&DW on human health throughout the whole life cycle, and provides reference and basis for future research and policy formulation.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 15 August 2023

Zul-Atfi Ismail

At the beginning of the Corona Virus Disease 2019 (COVID-19) pandemic, a digitalized construction environments surfaced in the heating, ventilation and air conditioning (HVAC…

Abstract

Purpose

At the beginning of the Corona Virus Disease 2019 (COVID-19) pandemic, a digitalized construction environments surfaced in the heating, ventilation and air conditioning (HVAC) systems in the form of a modern delivery system called demand controlled ventilation (DCV). Demand controlled ventilation has the potential to solve the building ventilation's biggest problem of managing indoor air quality (IAQ) for controlling COVID-19 transmission in indoor environments. However, the improper evaluation and information management of infection prevention on dense crowd activities such as measurement errors and volatile organic compound (VOC) generation failure rates, is fragmented so the aim of this research is to integrate this and explore potentials with machine learning algorithms (MLAs).

Design/methodology/approach

The method used is a thorough systematic literature review (SLR) approach. The results of this research consist of a detailed description of the DCV system and digitalized construction process of its IAQ elements.

Findings

The discussion revealed that DCV has a potential for being further integrated by perceiving it as a MLAs and hereby enabling the management of IAQ level from the perspective of health risk function mechanism (i.e. VOC and CO2) for maintaining a comfortable thermal environment and save energy of public and private buildings (PPBs). The appropriate MLA can also be selected in different occupancy patterns for seasonal variations, ventilation behavior, building type and locations, as well as current indoor air pollution control strategies. Furthermore, the conceptual framework showed that MLA application such as algorithm design/Model Predictive Control (MPC) integration can alleviate the high spread limitation of COVID-19 in the indoor environment.

Originality/value

Finally, the research concludes that a large unexploited potential within integration and innovation is recognized in the DCV system and MLAs which can be improved to optimize level of IAQ from the perspective of health throughout the building sector DCV process systems. The requirements of CO2 based DCV along with VOC concentrations monitoring practice should be taken into consideration through further research and experience with adaption and implementation from the ventilation control initial stage of the DCV process.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 7 May 2024

Nalinda Dissanayaka, Hamish Alexander, Danilo Carluccio, Michael Redmond, Luigi-Jules Vandi and James I. Novak

Three-dimensional (3D)printed skulls for neurosurgical training are increasingly being used due to the widespread access to 3D printing technology, their low cost and accuracy, as…

Abstract

Purpose

Three-dimensional (3D)printed skulls for neurosurgical training are increasingly being used due to the widespread access to 3D printing technology, their low cost and accuracy, as well as limitations and ethical concerns associated with using human cadavers. However, little is known about the risks of airborne particles or volatile organic compounds (VOCs) released while drilling into 3D-printed plastic models. The aim of this study is to assess the level of exposure to airborne contaminants while burr hole drilling.

Design/methodology/approach

3D-printed skull samples were produced using three different materials (polyethylene terephthalate glycol [PETG], white resin and BoneSTN) across three different 3D print processes (fused filament fabrication, stereolithography [SLA] and material jetting). A neurosurgeon performed extended burr hole drilling for 10 min on each sample. Spot measurements of particulate matter (PM2.5 and PM10) were recorded, and air samples were analysed for approximately 90 VOCs.

Findings

The particulate matter for PETG was found to be below the threshold value for respirable particles. However, the particulate matter for white resin and BoneSTN was found to be above the threshold value at PM10, which could be harmful for long periods of exposure without personal protective equipment (PPE). The VOC measurements for all materials were found to be below safety thresholds, and therefore not harmful.

Originality/value

To the best of the authors’ knowledge, this is the first study to evaluate the safety of 3D-printed materials for burr hole surgical drilling. It recommends PETG as a safe material requiring minimal respiratory control measures, whereas resin-based materials will require safety controls to deal with airborne particles.

Details

Rapid Prototyping Journal, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 1 January 2024

Hongya Niu, Chunmiao Wu, Xinyi Ma, Xiaoteng Ji, Yuting Tian and Jinxi Wang

This study aims to better understand the morphological characteristics of single particle and the health risk characteristics of heavy metals in PM2.5 in different functional…

Abstract

Purpose

This study aims to better understand the morphological characteristics of single particle and the health risk characteristics of heavy metals in PM2.5 in different functional areas of Handan City.

Design/methodology/approach

High resolution transmission electron microscopy was used to observe the aerosol samples collected from different functional areas of Handan City. The morphology and size distribution of the particles collected on hazy and clear days were compared. The health risk evaluation model was applied to evaluate the hazardous effects of particles on human health in different functional areas on hazy days.

Findings

The results show that the particulate matter in different functional areas is dominated by spherical particles in different weather conditions. In particular, the proportion of spherical particles exceeds 70% on the haze day, and the percentage of soot aggregates increases significantly on the clear day. The percentage of each type of particle in the teaching and living areas varied less under different weather conditions. Except for the industrial area, the size distribution of each type of particle in haze samples is larger than that on the clear day. Spherical particles contribute more to the small particle size segment. Soot aggregate and other shaped particles contribute more to the large size segment. The mass concentrations of hazardous elements (HEs) in PM2.5 in different functional areas on consecutive haze pollution days were illustrated as industrial area > traffic area > living area > teaching area. Compared with the other functional areas, the teaching area had the lowest noncarcinogenic risk of HEs. The lifetime carcinogenic risk values of Cr and As elements in each functional area have exceeded residents’ threshold levels and are at high risk of carcinogenicity. Among the four functional areas, the industrial area has the highest carcinogenic and noncarcinogenic risks. But the effects of HEs on human health in the other functional areas should also be taken seriously and continuously controlled.

Originality/value

The significance of the study is to further understand the morphological characteristics of single particles and the health risks of heavy metals in different functional areas of Handan City. the authors hope to provide a reference for other coal-burning industrial cities to develop plans to improve air quality and human respiratory health.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 5 December 2023

Balamurali Kanagaraj, N. Anand, Johnson Alengaram and Diana Andrushia

The present work focuses on evaluating the physical and mechanical characteristics of geopolymer concrete (GPC) by replacing the sodium silicate waste (SSW) in place of…

Abstract

Purpose

The present work focuses on evaluating the physical and mechanical characteristics of geopolymer concrete (GPC) by replacing the sodium silicate waste (SSW) in place of traditional river sand. The aim is to create eco-friendly concrete that mitigates the depletion of conventional river sand and conserves natural resources. Additionally, the study seeks to explore how the moisture content of filler materials affects the performance of GPC.

Design/methodology/approach

SSW obtained from the sodium silicate industry was used as filler material in the production of GPC, which was cured at ambient temperature. Instead of the typical conventional river sand, SSW was substituted at 25 and 50% of its weight. Three distinct moisture conditions were applied to both river sand and SSW. These conditions were classified as oven dry (OD), air dry (AD) and saturated surface dry (SSD).

Findings

As the proportion of SSW increased, there was a decrease in the slump of the GPC. The setting time was significantly affected by the higher percentage of SSW. The presence of angular-shaped SSW particles notably improved the compressive strength of GPC when replacing a portion of the river sand with SSW. When exposed to elevated temperatures, the performance of the GPC with SSW exhibited similar behavior to that of the mix containing conventional river sand, but it demonstrated a lower residual strength following exposure to elevated temperatures.

Originality/value

Exploring the possible utilization of SSW as a substitute for river sand in GPC, and its effects on the performance of the proposed mix. Analyzing, how varying moisture conditions affect the performance of GPC containing SSW. Evaluating the response of the GPC with SSW exposed to elevated temperatures in contrast to conventional river sand.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 20 March 2024

Malav R. Sanghvi, Karan W. Chugh and S.T. Mhaske

This study aims to synthesize Prussian blue {FeIII4[FeII(CN)6]3} pigment by reacting ferric chloride with different ferrocyanides through the same procedure. The influence of the…

Abstract

Purpose

This study aims to synthesize Prussian blue {FeIII4[FeII(CN)6]3} pigment by reacting ferric chloride with different ferrocyanides through the same procedure. The influence of the ferrocyanide used on resulting pigment properties is studied.

Design/methodology/approach

Prussian blue is commonly synthesized by direct or indirect methods, through iron salt and ferrocyanide/ferricyanide reactions. In this study, the direct, single-step process was pursued by dropwise addition of the ferrocyanide into ferric chloride (both as aqueous solutions). Two batches – (K-PB) and (Na-PB) – were prepared by using potassium ferrocyanide and sodium ferrocyanide, respectively. The development of pigment was confirmed by an identification test and characterized by spectroscopic techniques. Pigment properties were determined, and light fastness was observed for acrylic emulsion films incorporating dispersed pigment.

Findings

The two pigments differed mainly in elemental detection owing to the dissimilar ferrocyanide being used; IR spectroscopy where only (Na-PB) showed peaks indicating water molecules; and bleeding tendency where (K-PB) was water soluble whereas (Na-PB) was not. The pigment exhibited remarkable blue colour and good bleeding resistance in several solvents and showed no fading in 24 h of light exposure though oil absorption values were high.

Originality/value

This article is a comparative study of Prussian blue pigment properties obtained using different ferrocyanides. The dissimilarity in the extent of water solubility will influence potential applications as a colourant in paints and inks. K-PB would be advantageous in aqueous formulations to confer a blue colour without any dispersing aid but unfavourable in systems where other coats are water-based due to their bleeding tendency.

Details

Pigment & Resin Technology, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 14 July 2023

Sweety Poornima Rau Merugu and Manjunath Y.M.

This study aims at designing consistent and durable concrete by making use of waste materials. An investigation has been carried out to evaluate the performance of conventional…

Abstract

Purpose

This study aims at designing consistent and durable concrete by making use of waste materials. An investigation has been carried out to evaluate the performance of conventional and optimal concrete (including 5% GP) at high temperatures for different exposure times.

Design/methodology/approach

An experimental work is carried out to compare the conventional and optimal concrete with respect to weight loss, mechanical strength characteristics (compressive, tensile and flexural) after exposed to 100, 200 and 300 °C with 1, 2 and 3 h duration of exposure followed by cooling in furnace for 24 h and then air cooling.

Findings

The workability of granite powder modified concrete decreases as percentage of replacement increases. Compressive, tensile and flexural strengths all increased at 100 °C when compared to strength characteristics at normal temperature, regardless of the exposure conditions, and there was no weight loss noticed. For 200 and 300 °C, the strengths were decreased compared to normal temperature and an elevated temperature of 100 °C, as weight loss of concrete specimens are observed to be decreased at these temperatures. So, the optimum elevated temperature can be concluded as 100 °C.

Originality/value

Incorporating pozzolanic binder (granite powder) as cement replacement subjecting to elevated temperatures in an electric furnace is the research gap in this area. Many of the works were carried out replacing GP for fine aggregate at normal temperatures and not at elevated temperatures.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords