Search results
1 – 10 of 45Kesavan Devarayan, Yazhiniyan Palanisamy, Gangeswar Mohan, Anand Theivasigamani, Sabariswaran Kandasamy, Vimaladevi Sekar, Evon Umesh Siluvai John, Monikandon Sukumaran, Ramar Marimuthu and Hema Anjappan
This study aims to develop a pH-functional thin-film sensor for non-invasive measurement of spoilage of packed fish.
Abstract
Purpose
This study aims to develop a pH-functional thin-film sensor for non-invasive measurement of spoilage of packed fish.
Design/methodology/approach
At first, polymers of natural origin such as hydroxy(propyl)methyl cellulose, potato dextrose agar and starch alongside a pH sensitive-mixed indicator formulation were used to produce thin film sensor. The developed thin film sensor was tested for monitoring the spoilage of seafood stored at 4°C. Using ultraviolet-visible and Fourier-transform infrared spectroscopy, the halochromic sensor was characterised. In addition, the halochromic response of the thin film was directly correlated to the total volatile base nitrogen emitted by the packaged fish, pH, microbial activity and sensory evaluation.
Findings
The results suggested the developed biopolymer-based thin film sensor showed different colours in line with the spoilage of the packed fish, which could be well correlated with the total volatile base nitrogen, microbial activity and sensory evaluation. In addition, the thin film sensors exhibited a high degree of biodegradability. The biopolymers-based thin film halochromic sensor has exhibited excellent biodegradability along with sensitiveness towards the spoilage of the packed fish.
Originality/value
In the future, consumers and retailers may prefer seafood containers equipped with such halochromic sensors to determine the degree of food deterioration as a direct indicator of food quality.
Details
Keywords
Zhaozhao Tang, Wenyan Wu, Po Yang, Jingting Luo, Chen Fu, Jing-Cheng Han, Yang Zhou, Linlin Wang, Yingju Wu and Yuefei Huang
Surface acoustic wave (SAW) sensors have attracted great attention worldwide for a variety of applications in measuring physical, chemical and biological parameters. However…
Abstract
Purpose
Surface acoustic wave (SAW) sensors have attracted great attention worldwide for a variety of applications in measuring physical, chemical and biological parameters. However, stability has been one of the key issues which have limited their effective commercial applications. To fully understand this challenge of operation stability, this paper aims to systematically review mechanisms, stability issues and future challenges of SAW sensors for various applications.
Design/methodology/approach
This review paper starts with different types of SAWs, advantages and disadvantages of different types of SAW sensors and then the stability issues of SAW sensors. Subsequently, recent efforts made by researchers for improving working stability of SAW sensors are reviewed. Finally, it discusses the existing challenges and future prospects of SAW sensors in the rapidly growing Internet of Things-enabled application market.
Findings
A large number of scientific articles related to SAW technologies were found, and a number of opportunities for future researchers were identified. Over the past 20 years, SAW-related research has gained a growing interest of researchers. SAW sensors have attracted more and more researchers worldwide over the years, but the research topics of SAW sensor stability only own an extremely poor percentage in the total researc topics of SAWs or SAW sensors.
Originality/value
Although SAW sensors have been attracting researchers worldwide for decades, researchers mainly focused on the new materials and design strategies for SAW sensors to achieve good sensitivity and selectivity, and little work can be found on the stability issues of SAW sensors, which are so important for SAW sensor industries and one of the key factors to be mature products. Therefore, this paper systematically reviewed the SAW sensors from their fundamental mechanisms to stability issues and indicated their future challenges for various applications.
Details
Keywords
Majid Monajjemi and Fatemeh Mollaamin
Recently, powerful instruments for biomedical engineering research studies, including disease modeling, drug designing and nano-drug delivering, have been extremely investigated…
Abstract
Purpose
Recently, powerful instruments for biomedical engineering research studies, including disease modeling, drug designing and nano-drug delivering, have been extremely investigated by researchers. Particularly, investigation in various microfluidics techniques and novel biomedical approaches for microfluidic-based substrate have progressed in recent years, and therefore, various cell culture platforms have been manufactured for these types of approaches. These microinstruments, known as tissue chip platforms, mimic in vivo living tissue and exhibit more physiologically similar vitro models of human tissues. Using lab-on-a-chip technologies in vitro cell culturing quickly caused in optimized systems of tissues compared to static culture. These chipsets prepare cell culture media to mimic physiological reactions and behaviors.
Design/methodology/approach
The authors used the application of lab chip instruments as a versatile tool for point of health-care (PHC) applications, and the authors applied a current progress in various platforms toward biochip DNA sensors as an alternative to the general bio electrochemical sensors. Basically, optical sensing is related to the intercalation between glass surfaces containing biomolecules with fluorescence and, subsequently, its reflected light that arises from the characteristics of the chemical agents. Recently, various techniques using optical fiber have progressed significantly, and researchers apply highlighted remarks and future perspectives of these kinds of platforms for PHC applications.
Findings
The authors assembled several microfluidic chips through cell culture and immune-fluorescent, as well as using microscopy measurement and image analysis for RNA sequencing. By this work, several chip assemblies were fabricated, and the application of the fluidic routing mechanism enables us to provide chip-to-chip communication with a variety of tissue-on-a-chip. By lab-on-a-chip techniques, the authors exhibited that coating the cell membrane via poly-dopamine and collagen was the best cell membrane coating due to the monolayer growth and differentiation of the cell types during the differentiation period. The authors found the artificial membrane, through coating with Collagen-A, has improved the growth of mouse podocytes cells-5 compared with the fibronectin-coated membrane.
Originality/value
The authors could distinguish the differences across the patient cohort when they used a collagen-coated microfluidic chip. For instance, von Willebrand factor, a blood glycoprotein that promotes hemostasis, can be identified and measured through these type-coated microfluidic chips.
Details
Keywords
Kesavan Devarayan, Deepika Anandakumar Muthurani, Geetha Kannusamy, Anand Theivasigamani, Yazhiniyan Palanisamy, Gangeswar Mohan, Monikandon Sukumaran, Evon Umesh Siluvai John, Ramar Marimuthu and Hema Anjappan
This study aims to describe on-site determination of pH in aquaculture using a portable colorimeter.
Abstract
Purpose
This study aims to describe on-site determination of pH in aquaculture using a portable colorimeter.
Design/methodology/approach
A basic and inexpensive portable colorimeter having light sources of different wavelength has been optimized for the determination of pH. A chromic reagent is optimized to develop colors depending on different pHs. Then, the color is measured using portable colorimeter in terms of resistance. Using the resistance to absorbance relationship, the resistance values are converted to absorbance. The performance of the developed colorimetric system is compared with commercially available colorimeter and pH meter. Eighty brackish water aquaculture samples were tested using the developed colorimetric system to check its adaptability in aquaculture farms.
Findings
A chromic reagent optimized in this study exhibited linear relationship with the pH changes of pH standards. Portable colorimeter having three different light sources is optimized using this chromic agent for determination of pH. Colorimeter possessing yellow light revealed more linear results than the others. The developed colorimetric system determines the pH of aquaculture water with an accuracy of ±0.14 in comparison with commercial colorimeter at the pH range of 6.0−9.0.
Originality/value
pH plays a pivotal role in aquaculture, impacting not only productivity but also profitability. The colorimetric system introduced in this research is promising for pH measurement in the field of brackish water aquaculture. The on-site pH assessment facilitated by this colorimetric system holds significant potential for adoption within the aquaculture sector, owing to its precision, portability, simplicity of use and user-friendly nature.
Details
Keywords
The purpose of this study is to develop a molecular imprinting electrochemical sensor for the specific detection of the anticancer drug amsacrine. The sensor used a composite of…
Abstract
Purpose
The purpose of this study is to develop a molecular imprinting electrochemical sensor for the specific detection of the anticancer drug amsacrine. The sensor used a composite of bacterial cellulose (BC) and silver nanoparticles (AgNPs) as a platform for the immobilization of a molecularly imprinted polymer (MIP) film. The main objective was to enhance the electrochemical properties of the sensor and achieve a high level of selectivity and sensitivity toward amsacrine molecules in complex biological samples.
Design/methodology/approach
The composite of BC-AgNPs was synthesized and characterized using FTIR, XRD and SEM techniques. The MIP film was molecularly imprinted to selectively bind amsacrine molecules. Electrochemical characterization, including cyclic voltammetry and electrochemical impedance spectroscopy, was performed to evaluate the modified electrode’s conductivity and electron transfer compared to the bare glassy carbon electrode (GCE). Differential pulse voltammetry was used for quantitative detection of amsacrine in the concentration range of 30–110 µM.
Findings
The developed molecular imprinting electrochemical sensor demonstrated significant improvements in conductivity and electron transfer compared to the bare GCE. The sensor exhibited a linear response to amsacrine concentrations between 30 and 110 µM, with a low limit of detection of 1.51 µM. The electrochemical response of the sensor showed remarkable changes before and after amsacrine binding, indicating the successful imprinting of amsacrine in the MIP film. The sensor displayed excellent selectivity for amsacrine in the presence of interfering substances, and it exhibited good stability and reproducibility.
Originality/value
This study presents a novel molecular imprinting electrochemical sensor design using a composite of BC and AgNPs as a platform for MIP film immobilization. The incorporation of BC-AgNPs improved the sensor’s electrochemical properties, leading to enhanced sensitivity and selectivity for amsacrine detection. The successful imprinting of amsacrine in the MIP film contributes to the sensor's specificity. The sensor's ability to detect amsacrine in a concentration range relevant to anticancer therapy and its excellent performance in complex sample matrices add significant value to the field of electrochemical sensing for pharmaceutical analysis.
Details
Keywords
Jinwei Zhao, Shuolei Feng, Xiaodong Cao and Haopei Zheng
This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and…
Abstract
Purpose
This paper aims to concentrate on recent innovations in flexible wearable sensor technology tailored for monitoring vital signals within the contexts of wearable sensors and systems developed specifically for monitoring health and fitness metrics.
Design/methodology/approach
In recent decades, wearable sensors for monitoring vital signals in sports and health have advanced greatly. Vital signals include electrocardiogram, electroencephalogram, electromyography, inertial data, body motions, cardiac rate and bodily fluids like blood and sweating, making them a good choice for sensing devices.
Findings
This report reviewed reputable journal articles on wearable sensors for vital signal monitoring, focusing on multimode and integrated multi-dimensional capabilities like structure, accuracy and nature of the devices, which may offer a more versatile and comprehensive solution.
Originality/value
The paper provides essential information on the present obstacles and challenges in this domain and provide a glimpse into the future directions of wearable sensors for the detection of these crucial signals. Importantly, it is evident that the integration of modern fabricating techniques, stretchable electronic devices, the Internet of Things and the application of artificial intelligence algorithms has significantly improved the capacity to efficiently monitor and leverage these signals for human health monitoring, including disease prediction.
Nibu Babu Thomas, Lekshmi P. Kumar, Jiya James and Nibu A. George
Nanosensors have a wide range of applications because of their high sensitivity, selectivity and specificity. In the past decade, extensive and pervasive research related to…
Abstract
Purpose
Nanosensors have a wide range of applications because of their high sensitivity, selectivity and specificity. In the past decade, extensive and pervasive research related to nanosensors has led to significant progress in diverse fields, such as biomedicine, environmental monitoring and industrial process control. This led to better and more efficient detection and monitoring of physical and chemical properties at better resolution, opening new horizons in the development of novel technologies and applications for improved human health, environment protection, enhanced industrial processes, etc.
Design/methodology/approach
In this paper, the authors discuss the application of citation network analysis in the field of nanosensor research and development. Cluster analysis was carried out using papers published in the field of nanomaterial-based sensor research, and an in-depth analysis was carried out to identify significant clusters. The purpose of this study is to provide researchers to identify a pathway to the emerging areas in the field of nanosensor research. The authors have illustrated the knowledge base, knowledge domain and knowledge progression of nanosensor research using the citation analysis based on 3,636 Science Citation Index papers published during the period 2011 to 2021.
Findings
Among these papers, the bibliographic study identified 809 significant research publications, 11 clusters, 556 research sector keywords, 1,296 main authors, 139 referenced authors, 63 nations, 206 organizations and 42 journals. The authors have identified single quantum dot (QD)-based nanosensor for biological applications, carbon dot-based nanosensors, self-powered triboelectric nanogenerator-based nanosensor and genetically encoded nanosensor as the significant research hotspots that came to the fore in recent years. The future trend in nanosensor research might focus on the development of efficient and cost-effective designs for the detection of numerous environmental pollutants and biological molecules using mesostructured materials and QDs. It is also possible to optimize the detection methods using theoretical models, and generalized gradient approximation has great scope in sensor development.
Research limitations/implications
The future trend in nanosensor research might focus on the development of efficient and cost-effective designs for the detection of numerous environmental pollutants and biological molecules using mesostructured materials and QDs. It is also possible to optimize the detection methods using theoretical models, and generalized gradient approximation has great scope in sensor development.
Originality/value
This is a novel bibliometric analysis in the area of “nanomaterial based sensor,” which is carried out in CiteSpace software.
Details
Keywords
Abhishek Barwar, Prateek Kala and Rupinder Singh
Some studies have been reported in the past on diaphragmatic hernia (DH) surgery techniques using additive manufacturing (AM) technologies, symptoms of a hernia and post-surgery…
Abstract
Purpose
Some studies have been reported in the past on diaphragmatic hernia (DH) surgery techniques using additive manufacturing (AM) technologies, symptoms of a hernia and post-surgery complications. But hitherto little has been reported on bibliographic analysis (BA) for health monitoring of bovine post-DH surgery for long-term management. Based on BA, this study aims to explore the sensor fabrication integrated with innovative AM technologies for health monitoring assistance of bovines post-DH surgery.
Design/methodology/approach
A BA based on the data extracted through the Web of Science database was performed using bibliometric tools (R-Studio and Biblioshiny).
Findings
After going through the BA and a case study, this review provides information on various 3D-printed meshes used over the sutured site and available Internet of Things-based solutions to prevent the recurrence of DH.
Originality/value
Research gaps exist for 3D-printed conformal sensors for health monitoring of bovine post-DH surgery.
Details
Keywords
Adhithya Sreeram and Jayaraman Kathirvelan
Artificial fruit ripening is hazardous to mankind. In the recent past, artificial fruit ripening is increasing gradually due to its commercial benefits. To discriminate the type…
Abstract
Purpose
Artificial fruit ripening is hazardous to mankind. In the recent past, artificial fruit ripening is increasing gradually due to its commercial benefits. To discriminate the type of fruit ripening involved at the vendors’ side, there is a great demand for on-sight ethylene detection in a nondestructive manner. Therefore, this study aims to deal with a comparison of various laboratory and portable methods developed so far with high-performance metrics to identify the ethylene detection at fruit ripening site.
Design/methodology/approach
This paper focuses on various types of technologies proposed up to date in ethylene detection, fabrication methods and signal conditioning circuits for ethylene detection in parts per million and parts per billion levels. The authors have already developed an infrared (IR) sensor to detect ethylene and also developed a lab-based setup belonging to the electrochemical sensing methods to detect ethylene for the fruit ripening application.
Findings
The authors have developed an electrochemical sensor based on multi-walled carbon nanotubes whose performance is relatively higher than the sensors that were previously reported in terms of material, sensitivity and selectivity. For identifying the best sensing technology for optimization of ethylene detection for fruit ripening discrimination process, authors have developed an IR-based ethylene sensor and also semiconducting metal-oxide ethylene sensor which are all compared with literature-based comparable parameters. This review paper mainly focuses on the potential possibilities for developing portable ethylene sensing devices for investigation applications.
Originality/value
The authors have elaborately discussed the new chemical and physical methods of ethylene detection and quantification from their own developed methods and also the key findings of the methods proposed by fellow researchers working on this field. The authors would like to declare that the extensive analysis carried out in this technical survey could be used for developing a cost-effective and high-performance portable ethylene sensing device for fruit ripening and discrimination applications.
Details
Keywords
Livio Cricelli, Roberto Mauriello and Serena Strazzullo
This study aims to analyse how the adoption of Industry 4.0 technologies can help different types of agri-food supply chains introduce and manage innovations in response to the…
Abstract
Purpose
This study aims to analyse how the adoption of Industry 4.0 technologies can help different types of agri-food supply chains introduce and manage innovations in response to the challenges and opportunities that emerged following the COVID-19 pandemic.
Design/methodology/approach
A systematic literature review methodology was used to bring together the most relevant contributions from different disciplines and provide comprehensive results on the use of I4.0 technologies in the agri-food industry.
Findings
Four technological clusters are identified, which group together the I4.0 technologies based on the applications in the agri-food industry, the objectives and the advantages provided. In addition, three types of agri-food supply chains have been identified and their configuration and dynamics have been studied. Finally, the I4.0 technologies most suited for each type of supply chain have been identified, and suggestions on how to effectively introduce and manage innovations at different levels of the supply chain are provided.
Originality/value
The study highlights how the effective adoption of I4.0 technologies in the agri-food industry depends on the characteristics of the supply chains. Technologies can be used for different purposes and managers should carefully consider the objectives to be achieved and the synergies between technologies and supply chain dynamics.
Details