Search results

1 – 10 of 178
Article
Publication date: 20 April 2023

Fatemeh Goodarzi, Kavitha Palaniappan, Manikam Pillay and Mahmoud Ershadi

Exposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness…

Abstract

Purpose

Exposure to poor indoor air in refurbished buildings is a matter of health concern due to the growing concentrations of various contaminants as a result of building airtightness without amendment of ventilation, or the use of building materials such as glue, paint, thinner and varnishes. Recent studies have been conducted to measure indoor air pollutants and assess the health risks affecting the quality of life, productivity and well-being of human beings. However, limited review studies have been recently conducted to provide an overview of the state of knowledge. This study aims to conduct a scoping review of indoor air quality (IAQ) in the context of refurbished or energy-retrofitted buildings.

Design/methodology/approach

A systematic screening process based on the PRISMA protocol was followed to extract relevant articles. Web of Science, Scopus, Google Scholar and PubMed were searched using customised search formulas. Among 276 potentially relevant records, 38 studies were included in the final review covering a period from 2015 to 2022.

Findings

Researchers mapped out the measured compounds in the selected studies and found that carbon dioxide (CO2) (11%) and total volatile organic compounds (11%) were among the most commonly measured contaminants. Two trends of research were found including (1) the impact of ventilative properties on IAQ and (2) the impact of introducing building materials on IAQ.

Originality/value

The contribution of this study lies in summarising evidence on IAQ measurements in refurbished buildings, discussing recent advancements, revealing significant gaps and limitations, identifying the trends of research and drawing conclusions regarding future research directions on the topic.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 15 August 2023

Zul-Atfi Ismail

At the beginning of the Corona Virus Disease 2019 (COVID-19) pandemic, a digitalized construction environments surfaced in the heating, ventilation and air conditioning (HVAC…

Abstract

Purpose

At the beginning of the Corona Virus Disease 2019 (COVID-19) pandemic, a digitalized construction environments surfaced in the heating, ventilation and air conditioning (HVAC) systems in the form of a modern delivery system called demand controlled ventilation (DCV). Demand controlled ventilation has the potential to solve the building ventilation's biggest problem of managing indoor air quality (IAQ) for controlling COVID-19 transmission in indoor environments. However, the improper evaluation and information management of infection prevention on dense crowd activities such as measurement errors and volatile organic compound (VOC) generation failure rates, is fragmented so the aim of this research is to integrate this and explore potentials with machine learning algorithms (MLAs).

Design/methodology/approach

The method used is a thorough systematic literature review (SLR) approach. The results of this research consist of a detailed description of the DCV system and digitalized construction process of its IAQ elements.

Findings

The discussion revealed that DCV has a potential for being further integrated by perceiving it as a MLAs and hereby enabling the management of IAQ level from the perspective of health risk function mechanism (i.e. VOC and CO2) for maintaining a comfortable thermal environment and save energy of public and private buildings (PPBs). The appropriate MLA can also be selected in different occupancy patterns for seasonal variations, ventilation behavior, building type and locations, as well as current indoor air pollution control strategies. Furthermore, the conceptual framework showed that MLA application such as algorithm design/Model Predictive Control (MPC) integration can alleviate the high spread limitation of COVID-19 in the indoor environment.

Originality/value

Finally, the research concludes that a large unexploited potential within integration and innovation is recognized in the DCV system and MLAs which can be improved to optimize level of IAQ from the perspective of health throughout the building sector DCV process systems. The requirements of CO2 based DCV along with VOC concentrations monitoring practice should be taken into consideration through further research and experience with adaption and implementation from the ventilation control initial stage of the DCV process.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 28 September 2023

Williams Miller Appau, Elvis Attakora-Amaniampong and Iruka Chijindu Anugwo

To significantly adopt and improve indoor energy efficiency in building infrastructure in developing countries can be a challenging venture. Thus, this study aimed to assess the…

Abstract

Purpose

To significantly adopt and improve indoor energy efficiency in building infrastructure in developing countries can be a challenging venture. Thus, this study aimed to assess the satisfaction of indoor environmental quality and its effect on energy use intensity and efficient among student housing.

Design/methodology/approach

The study is quantitative and hinged on the contrast theory. A survey of 1,078 student residents living in purpose-built student housing was contacted. Using Post-Occupancy Evaluation and Multiple Linear Regression, critical variables such as thermal comfort, visual comfort and indoor air quality and 21 indicators were assessed. Data on annual energy consumption and total square metre of the indoor area were utilised to assess energy use intensity.

Findings

The study found a direct relationship between satisfaction with indoor environmental quality and energy use intensity. The study showed that students were more satisfied with thermal comfort conditions than visual and indoor air quality. Overall, these indicators contributed to 75.9% kWh/m2 minimum and 43.2% kWh/m2 maximum energy use intensity in student housing in Ghana. High occupancy and small useable space in student housing resulted in high energy use intensity.

Practical implications

Inclusions of sustainable designs and installation of smart mechanical systems are feedback to student housing designers. Again, adaptation to retrofitting ideas can facilitate energy efficiency in the current state of student housing in Ghana.

Originality/value

Earlier studies have argued for and against the satisfaction of indoor environmental quality in student housing. However, these studies have neglected to examine the impact on energy use intensity. This is novel because the assessment of energy use intensity in this study has a positive influence on active design incorporation among student housing.

Details

Property Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0263-7472

Keywords

Open Access
Article
Publication date: 6 March 2024

Chuloh Jung, Muhammad Azzam Ismail, Mohammad Arar and Nahla AlQassimi

This study aims to evaluate the efficiency of various techniques for enhancing indoor air quality (IAQ) in construction. It analyzed the alterations in the concentration of indoor…

Abstract

Purpose

This study aims to evaluate the efficiency of various techniques for enhancing indoor air quality (IAQ) in construction. It analyzed the alterations in the concentration of indoor air pollutants over time for each product employed in controlling pollution sources and removing it, which included eco-friendly substances and adsorbents. The study will provide more precise and dependable data on the effectiveness of these control methods, ultimately supporting the creation of more efficient and sustainable approaches for managing indoor air pollution in buildings.

Design/methodology/approach

The research investigates the impact of eco-friendly materials and adsorbents on improving indoor air quality (IAQ) in Dubai's tall apartment buildings. Field experiments were conducted in six units of The Gate Tower, comparing the IAQ of three units built with “excellent” grade eco-friendly materials with three built with “good” grade materials. Another experiment evaluated two adsorbent products (H and Z) in the Majestic Tower over six months. Results indicate that “excellent” grade materials significantly reduced toluene emissions. Adsorbent product Z showed promising results in pollutant reduction, but there is concern about the long-term behavior of adsorbed chemicals. The study emphasizes further research on household pollutant management.

Findings

The research studied the effects of eco-friendly materials and adsorbents on indoor air quality in Dubai's new apartments. It found that apartments using “excellent” eco-friendly materials had significantly better air quality, particularly reduced toluene concentrations, compared to those using “good” materials. However, high formaldehyde (HCHO) emissions were observed from wood products. While certain construction materials led to increased ethylbenzene and xylene levels, adsorbent product Z showed promise in reducing pollutants. Yet, there is a potential concern about the long-term rerelease of these trapped chemicals. The study emphasizes the need for ongoing research in indoor pollutant management.

Research limitations/implications

The research, while extensive, faced limitations in assessing the long-term behavior of adsorbed chemicals, particularly the potential for rereleasing trapped pollutants over time. Despite the study spanning a considerable period, indoor air pollutant concentrations in target households did not stabilize, making it challenging to determine definitive improvement effects and reduction rates among products. Comparisons were primarily relative between target units, and the rapid rise in pollutants during furniture introduction warrants further examination. Consequently, while the research provides essential insights, it underscores the need for more prolonged and comprehensive evaluations to fully understand the materials' and adsorbents' impacts on indoor air quality.

Practical implications

The research underscores the importance of choosing eco-friendly materials in new apartment constructions for better IAQ. Specifically, using “excellent” graded materials can significantly reduce harmful pollutants like toluene. However, the study also highlights that certain construction activities, such as introducing furniture, can rapidly elevate pollutant levels. Moreover, while adsorbents like product Z showed promise in reducing pollutants, there is potential for adsorbed chemicals to be rereleased over time. For practical implementation, prioritizing higher-grade eco-friendly materials and further investigation into furniture emissions and long-term behavior of adsorbents can lead to healthier indoor environments in newly built apartments.

Originality/value

The research offers a unique empirical assessment of eco-friendly materials' impact on indoor air quality within Dubai's rapidly constructed apartment buildings. Through field experiments, it directly compares different material grades, providing concrete data on pollutant levels in newly built environments. Additionally, it explores the efficacy of specific adsorbents, which is of high value to the construction and public health sectors. The findings shed light on how construction choices can influence indoor air pollution, offering valuable insights to builders, policymakers and residents aiming to promote public health and safety in urban living spaces.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Open Access
Article
Publication date: 15 December 2023

Francis Olawale Abulude, Domenico Suriano, Samuel Dare Oluwagbayide, Akinyinka Akinnusotu, Ifeoluwa Ayodeji Abulude and Emmanuel Awogbindin

This study aimed to characterize the concentrations of indoor pollutants (such as carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2) and sulfur dioxide (SO2), as well as…

Abstract

Purpose

This study aimed to characterize the concentrations of indoor pollutants (such as carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2) and sulfur dioxide (SO2), as well as particulate matter (PM) (PM1, PM2.5 and PM10) in Akure, Nigeria, as well as the relationship between the parameters’ concentrations.

Design/methodology/approach

The evaluation, which lasted four months, used a low-cost air sensor that was positioned two meters above the ground. All sensor procedures were correctly carried out.

Findings

CO2 (430.34 ppm), NO2 (93.31 ppb), O3 (19.94 ppb), SO2 (40.87 ppb), PM1 (29.31 µg/m3), PM2.5 (43.56 µg/m3), PM10 (50.70 µg/m3), temperature (32.4°C) and relative humidity (50.53%) were the average values obtained. The Pearson correlation depicted the relationships between the pollutants and weather factors. With the exception of April, which had significant SO2 (18%) and low PM10 (49%) contributions, NO2 and PM10 were the most common pollutants in all of the months. The mean air quality index (AQI) for NO2 indicated that the AQI was “moderate” (51–100). In contrast to SO2, whose AQI ranged from “moderate” to “very unhealthy,” O3's AQI ranged from “good” (50) to “unhealthy” (151–200). Since PM1, PM2.5 and PM10 made up the majority of PC1’s contribution, both PM2.5 and PM10 were deemed “hazardous.”

Practical implications

The practical implication of indoor air pollution is long-term health effects, including heart disease, lung cancer and respiratory diseases such as emphysema. Indoor air pollution can also cause long-term damage to people’s nerves, brain, kidneys, liver and other organs.

Originality/value

Lack of literature in terms of indoor air quality (IAQ) in Akure, Ondo State. With this work, the information obtained will assist all stakeholders in policy formulation and implementation. Again, the low-cost sensor used is new to this part of the world.

Details

Arab Gulf Journal of Scientific Research, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1985-9899

Keywords

Article
Publication date: 31 January 2024

Tamer Refaat and Marwa El-Zoklah

This study aims to formulate a user-friendly pre-design model that could be a decision support tool for green wall systems to assist designers in selecting an optimal green wall…

Abstract

Purpose

This study aims to formulate a user-friendly pre-design model that could be a decision support tool for green wall systems to assist designers in selecting an optimal green wall system aligned with specified performance criteria while concurrently addressing project requirements linked to social and economic parameters. This approach seeks to enhance overall project satisfaction for the designer and the owner.

Design/methodology/approach

A correlation between the green wall context and design requirements and its performance on the buildings have been defined by considering its social and economic parameters, which represented the owner preferences to ensure the most satisfaction from installation as it achieves the required performance that is defined by the designer such as maximizing thermal insulation, improving indoor air quality, reducing the needed heating and cooling loads, etc. and also to achieve the satisfaction in social and economic requirements defined by the owner such as system installation cost, system maintenance cost, adding beauty value, etc.

Findings

The research developed an easy pre-design model to be a tool for green wall system decision-making for the most suitable system, which contains three main steps: the first one is defining the required performance of the green wall (designer requirements), the second step is limiting the context of the project which is made by designer and the owner requirements and finally the third step is choosing the system components that ensures achieving the requirements of both owners and designer, related to the building and climate context.

Originality/value

The added value lies in developing a green wall decision-making tool, essentially a pre-design model. This model considers the correlation between the project’s context, encompassing climate and building conditions. It provides a structured approach for decision-making in the early stages of green wall design. It offers valuable insights into the optimal choices related to system type, installation methods and plant characteristics. This enhanced decision-making tool contributes to more informed and efficient design processes, considering each project’s specific needs and conditions.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 29 September 2023

Li Wang, Yanhong Lv, Tao Wang, Shuting Wan and Yanling Ye

The purpose of this research is to address the existing gap in the study of construction and demolition waste (C&DW) by focusing on its impact on human health throughout the…

Abstract

Purpose

The purpose of this research is to address the existing gap in the study of construction and demolition waste (C&DW) by focusing on its impact on human health throughout the entire life cycle. And this research provides a comprehensive assessment model that incorporates the release of gaseous pollutants and particulate matter during the whole life cycle of C&DW, thereby contributing to a more holistic understanding of its impact on human health.

Design/methodology/approach

The research was conducted in two stages. Firstly, the quantitative model framework of pollutants emitted by C&DW was established. Three types of pollutants were considered, namely nitrogen dioxide (NO2), sulfur dioxide (SO2) and inhalable particulate matter (PM10). Second, disability-adjusted life year (DALY) and willingness to pay (WTP) assessments were used to provide a monetary quantified health impact for pollutants released by C&DW.

Findings

The results show that the WTP value of PM10 is the highest among all pollutants and 8.68E+07 dollars/a, while the WTP value in the disposal stage accounts for the largest proportion compared to the generation and transportation stage. These findings emphasize the importance of PM10 and C&DW treatment stage for pollutant treatment.

Originality/value

The results of this study are of great significance for the management department to optimize the construction management scheme to reduce the total amount of pollutants produced by C&DW and its harm to human health. Meanwhile, this study fills the gap in existing research on the impact assessment of C&DW on human health throughout the whole life cycle, and provides reference and basis for future research and policy formulation.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 4 April 2024

Sze Yee Boo and Consilz Tan

This research intends to investigate the determinants that affect consumers’ purchase intention of electric vehicles (EVs) in Malaysia using an extended theory of planned…

Abstract

Purpose

This research intends to investigate the determinants that affect consumers’ purchase intention of electric vehicles (EVs) in Malaysia using an extended theory of planned behaviour (TPB).

Design/methodology/approach

Survey data were collected with a sample size of 306. The research used SmartPLS 4.0 structural equation modelling tool to analyse the data. Reliability and validity tests (discriminant and convergent validity) were used and subsequently assessed the measurement and structural models. Mediation analysis was conducted to identify the role of the latent constructs.

Findings

The findings indicated that a green purchase attitude plays a complete mediation role in the effect of environmental knowledge on the purchase intention of EVs. In the same notion, the effect of price perception and availability of charging facilities on the purchase intention of EVs passes completely through perceived behavioural control. However, the subjective norm was an insignificant mediator of the impact between government support and EV purchase intention.

Research limitations/implications

This paper helps to examine the latent constructs that impact purchase intention using environmental knowledge, government support, price perception and the availability of charging facilities. Successful green marketing and a sustainable consumerism framework are seen as a booster to promote the usage of EVs in Malaysia.

Originality/value

An extended TPB model has been employed in this research to study the effects of the above-mentioned constructs. The results show that most of the extended constructs are significant in explaining the purchase intention. The empirical results address the gap in the consumer green attitude and provide insight into this area of study.

Details

Journal of Contemporary Marketing Science, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2516-7480

Keywords

Article
Publication date: 25 July 2023

Rasha Adel, Naglaa Megahed, Asmaa M. Hassan and Merhan Shahda

Passive design strategies contribute to improving indoor comfort conditions and reducing buildings' energy consumption. For several years, courtyards have received wide attention…

Abstract

Purpose

Passive design strategies contribute to improving indoor comfort conditions and reducing buildings' energy consumption. For several years, courtyards have received wide attention from researchers because of their significant role in reducing energy demand. However, the abundance of multi-story buildings and the courtyards' incompatibility with them, the courtyard is currently limited. Therefore, it is necessary to search for alternatives. This paper aims to bridge the gaps in previous limited studies considering skycourt as a passive alternative on the vertical plane of the facades in contrast to the courtyard.

Design/methodology/approach

This research presents an overview and a bibliometric analysis of the evolution of the courtyard to the skycourt via VOSviewer software and the bibliometrix R package.

Findings

The research provided various concepts related to skycourt as a promising passive design strategy, which can be suitable for multi-story buildings, starting with its evolution, characteristics, configurations, benefits, and challenges.

Practical implications

The findings can urge designers, researchers and policymakers to incorporate such an important passive alternative.

Social implications

Researchers, instructors, educational specialists, faculty members, and decision-makers can provide design motivation for skycourt in buildings, in addition to achieving awareness about skycourt and its significant benefits and its role as an important passive design strategy.

Originality/value

The research highlights the possibilities of the skycourt and its role as a passive design element as an extension of the courtyard in addition to identifying design indicators that help designers determine the appropriate designs.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 26 December 2023

Xueting Gong, Dinkneh Gebre Borojo and Jiang Yushi

Due to their limited capacity for adaptation and dependence on natural resources for economic growth, developing countries (DCs) tend to be more prone to climate change. It is…

Abstract

Purpose

Due to their limited capacity for adaptation and dependence on natural resources for economic growth, developing countries (DCs) tend to be more prone to climate change. It is argued that climate finance (CF) is a significant financial innovation to mitigate the negative effects of climate variation. However, the heterogeneous impacts of CF on environmental sustainability (ES) and social welfare (SW) have been masked. Thus, this study aims to investigate the heterogeneous effects of CF on ES and SW in 80 CF receipt DCs from 2002 to 2018. This study also aims to investigate the effects of CF on ES and SW based on population size, income heterogeneity and the type of CF.

Design/methodology/approach

The method of moments quantile regression (MMQR) with fixed effects is utilized. Alternatively, the fully modified least square (FMOLS) and dynamic least square (DOLS) estimators are used for the robustness test.

Findings

The findings revealed that DCs with the lowest and middle quantiles of EF, carbon dioxide (CO2) emissions and human development exhibit large beneficial impacts of CF on ES and SW. In contrast, the positive effects of CF on ES breakdown for countries with the largest distributions of EF and CO2 emissions. Besides, the impacts of CF on ES and SW depend on income heterogeneity, population size and the type of CF.

Practical implications

This study calls for a framework to integrate CF into all economic development decisions to strengthen climate-resilient SW and ES in DCs.

Originality/value

To the best of the authors’ knowledge, this is the first study to investigate the effects of CF on ES and SW in a wide range of DCs. Thus, it complements existing related literature focusing on the effects of CF on ES and SW.

Details

Kybernetes, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0368-492X

Keywords