Search results

1 – 10 of 228
Article
Publication date: 1 August 2001

S.M.R. Tabatabai and K.M. Mosalam

A system for optimum reinforcement design and non‐linear analysis of reinforced concrete structures is presented. The specially‐tailored program ORCHID (Optimum Reinforced…

Abstract

A system for optimum reinforcement design and non‐linear analysis of reinforced concrete structures is presented. The specially‐tailored program ORCHID (Optimum Reinforced Concrete Highly Interactive Dimensioning) is utilized for the reinforcement design and optimization. The commercially available program DIANA (DIsplacement ANAlyzer) is adopted for the non‐linear analysis and evaluation of the different reinforcement designs provided by ORCHID. It is demonstrated how the two programs intended to complete two separate tasks can be integrated in an environment for performance‐based reinforcement design ensuring cost‐effectiveness through optimization and structural safety through satisfying serviceability conditions. Examples of a one‐way slab in bending and a deep beam in membrane action, highlighting the specific aspects of such an integrated analysis/design environment, are provided.

Details

Engineering Computations, vol. 18 no. 5/6
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 19 June 2019

Ziyu Jin, John Gambatese, Ding Liu and Vineeth Dharmapalan

The prevention through design (PtD) concept has been widely recognized as one of the most effective approaches to eliminate or reduce construction site hazards. It encourages…

2483

Abstract

Purpose

The prevention through design (PtD) concept has been widely recognized as one of the most effective approaches to eliminate or reduce construction site hazards. It encourages engineers and architects to consider occupational safety and health during the planning and design phases. Nevertheless, the implementation of PtD is often inhibited because designers lack adequate knowledge about construction safety and the construction process, and limited design-for-safety tools and procedures are available for designers to use. The purpose of this paper is to provide designers a tool for assessing construction risks during early phases of multistory building projects at an activity level and on a daily basis in a 4D environment. By using the tool, proactive measures could be taken in the design and planning phase to reduce site hazards.

Design/methodology/approach

The proposed method consists of four steps including risk quantification at a design element level, 4D model integration with risk values, risk assessment, and design alternative selection and model acceptance. A case study was carried out to test and verify the proposed method.

Findings

The proposed tool has the capability to assess the safety risk for an entire multistory project and visualize safety risk in a particular time period, work space and task prior to construction. It benefits designers in conducting risk assessments and selecting design alternatives concerning safety. Contractors could also utilize the visualization and simulation results of the 4D model for site safety planning so that a range of risk mitigation strategies could be implemented during construction.

Originality/value

The study provides an innovative PtD tool targeting designers as primary end-users. The proposed tool helps designers assess construction risks and has potential to incorporate the top levels of the hierarchy of risk controls.

Details

Engineering, Construction and Architectural Management, vol. 26 no. 11
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 31 August 2022

Aya Qatawna, Rabab Allouzi and Samih Qaqish

The primary objective of this study is to produce one-way slabs made of LWFC with low density and sufficient compressive strength suitable for structural purpose then investigate…

Abstract

Purpose

The primary objective of this study is to produce one-way slabs made of LWFC with low density and sufficient compressive strength suitable for structural purpose then investigate their flexural behavior under various types of reinforcement and thickness of the slab and the influence of addition of PP fibers reinforcement on the mechanical behavior of reinforced concrete slabs. The specimens were tested using four-point loading. The results concerning load capacity, deflection and failure mode and crack pattern for each specimen were obtained. Also, an analytical investigation of PP fiber and GFG contribution on the flexural behavior of foamed concrete slabs is studied to investigate the significant role of PP fiber on the stress distribution in reinforced foam concrete and predict the flexural moment capacity.

Design/methodology/approach

The materials used in this study are cement, fine aggregate (sand), water, PP fibers, foaming agent, chemical additives if required, steel reinforcing rebars and glass fiber grid. The combination of these constituent materials will be used to produce foamed concrete in this research Then this study will present the experimental program of one-way foamed concrete slabs including slabs reinforced with GFR grids and another with steel reinforcements. The slabs will be tested in the laboratory under static loading conditions to investigate their ultimate capacities. The flexural behavior is to the interest of the slabs reinforced with GFR grids reinforcements in comparison with that of one with steel reinforcing rebars. Three groups are considered. (1) Group I: two slabs of PP fiber foamed concrete with minimum required reinforcements. (2) Group II: two slabs of PP fiber foamed concrete with glass fiber grids. (3) Group III: two slabs of PP fiber foamed concrete with the minimum required reinforcements and glass fiber grids.

Findings

The experimental results proved the effectiveness and efficiency of this the new system in producing a low density of concrete below 1900 kg/m3 had a corresponding strength of about 17 MPa at least. Besides, the presence of PP fibers had a noticeable improvement on the flexural strength values for all the examined slabs. It was found that the specimens reinforced with steel reinforcement mesh carried higher flexural capacity compared to these reinforced with GFG only. The specimens reinforced with GFG exhibited the lowest flexural capacity due to GFG separation from the concrete substrate. Also, an analytical investigation to predict the flexural strength of all tested specimens was carried out. The analytical results were agreed with the experimental results. Therefore, LWFC can be used as a substitute lightweight concrete material for the production of structural concrete applications in the construction industries today.

Research limitations/implications

Foamed concrete is a wide field to discuss. To achieve the objectives of the project, the study is focused on the foamed concrete with the following limitations: (1) because the aim of this research is to produce foamed concrete suitable for structural purposes, it is decided to produce mixes within the density range 1300–1900 kg/m3. (2) Simply-supported slabs are of considered. (3) This study also looks out by using GFR and without it.

Originality/value

The main objectives of this study were producing structural foamed concrete slabs and investigate their flexural response for residential uses.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 14 August 2024

Ala Taleb Obaidat, Yasmeen Taleb Obaidat and Ahmed Ashteyat

In this experimental investigation, the behavior of strengthened/repaired heat-damaged one-way self-compacted concrete (SCC) slabs with opening utilizing…

Abstract

Purpose

In this experimental investigation, the behavior of strengthened/repaired heat-damaged one-way self-compacted concrete (SCC) slabs with opening utilizing near-surface-mounted-carbon fiber reinforced polymers (NSM-CFRP) strips was explored.

Design/methodology/approach

CFRP strip configurations, number of strips and inclination were all investigated in this study. For three hours, slabs were exposed to temperatures of 23°C and 500°C. Four-point load was applied to control slabs, enhanced slabs and repaired slabs.

Findings

The results indicate that exposing the slabs to high temperatures reduces their load capability. The number of strips and angle of inclination around the slab opening have a considerable impact on the performance of the strengthened and/or repaired slabs, according to the experimental results. The load capacity, toughness and ductility index of a strengthened and/or repaired slab with opening increase as the number of CFRP strips increases by 143.8–150.5%, 137.3–149.9% and 122.3–124.5%, respectively. The use of NSM strips around the opening with zero inclination showed higher load compared to the NSM strips around the opening with other angles.

Originality/value

It is frequently important to construct openings in the slabs for ventilation, electrical supply, and other purposes. Making openings in slabs might affect the structure’s performance since the concrete and reinforcing would be cut off. SCC is a new type of concrete mixture that can fill in all the voids in the formwork with its own weight without the help of external vibration.  As a result, it is necessary to reinforce the slab under flexure and increase the flexural strength of the SCC slab. Therefore, this work investigates the effect of using NSM-CFRP strip  on the behavior of one way SCC slabs that have been heat-damaged.

Details

International Journal of Structural Integrity, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 2 December 2022

Naveen Revanna and Charles K.S. Moy

This paper employs a textile reinforcement strain comparison to study the response of Textile Reinforced Mortars (TRM) strengthened reinforced concrete one-way slab members in…

Abstract

Purpose

This paper employs a textile reinforcement strain comparison to study the response of Textile Reinforced Mortars (TRM) strengthened reinforced concrete one-way slab members in flexure using the finite element method. Basalt TRM (BTRM) is a relatively new composite in structural strengthening applications. Experimental data on BTRMs are limited in the literature and numerical analyses can help further the understanding of this composite. With this notion, Abaqus finite element software is utilised to create a numerical method to capture the mechanical response of strengthened slab members instead of time-consuming laboratory experiments.

Design/methodology/approach

A numerical method is developed and validated using existing experimental data set on one-way slabs strengthened using Basalt TRMs from the literature. An explicit solver is utilised to analyse the finite element model created using calibrated Concrete Damage Plasticity (CDP) parameters according to the experimental requirements. The generated model is applied to extract load, deflection and rebar strains sustained by strengthened reinforced concrete slabs as observed from the experimental reference chosen. The applicability of the developed model was studied beyond parametric studies by comparing the generated finite element tensile strain by the textile fibre with available formulae.

Findings

CDP calibration done has shown its adaptability. The predicted results in the form of load versus deflection, tensile and compressive damage patterns from the numerical analysis showed good agreement with the experimental data. A parametric study on various concrete strength, textile spacing and TRM bond length obtained shows TRM’s advantages and its favourability for external strengthening applications. A set of five formulae considered to predict the experimental strain showed varied accuracy.

Originality/value

The developed numerical model considers strain sustained by the textile fibre to make results more robust and reliable. The obtained strain from the numerical study showed good agreement with the experiment results.

Details

Multidiscipline Modeling in Materials and Structures, vol. 19 no. 1
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 27 December 2011

D. Matešan, J. Radnić, N. Grgić and V. Čamber

The paper first presents the results of experimental tests of limit strength capacity of a continuous reinforced concrete slab with two spans. The slab was loaded with point load…

Abstract

The paper first presents the results of experimental tests of limit strength capacity of a continuous reinforced concrete slab with two spans. The slab was loaded with point load in the middle of each span. The effect of the tensile rebars length above the inner support on the limit strength capacity of the slab was analyzed. Already developed numerical model by the authors for the analysis of reinforced and prestressed concrete slabs and shells, was additionally tested on the obtained experimental test results. The limit strength capacity of a one-way continuous reinforced concrete slab with two spans and different tensile reinforcement arrangements above the middle support, loaded by a uniformly distributed load, were analyzed by the model. The length of tensile reinforcement above the inner supports of one-way continuous slabs affects the limit strength capacity and deflection of slabs.

Details

World Journal of Engineering, vol. 8 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 19 September 2017

Li Zhang, Ya Wei, Francis Tat Kwong Au and Jing Li

This study aims to investigate the influence of tendon layout, pre-stressing force, bond condition and concrete spalling on the structural behaviour of two-way post-tensioned flat…

Abstract

Purpose

This study aims to investigate the influence of tendon layout, pre-stressing force, bond condition and concrete spalling on the structural behaviour of two-way post-tensioned flat slabs at elevated temperatures.

Design/methodology/approach

Fire tests of four scale specimens of two-way post-tensioned concrete flat slabs were performed and analysed. Three of them were provided with bonded tendons, while the other was unbonded for comparison. The fabrication of specimens, phenomena observed during testing, temperature distributions, deflections and occurrence of concrete spalling were examined.

Findings

Different degrees of concrete spalling observed at the soffit had significant effects on the temperature distribution and stress redistribution. This was the major reason for the progressive concrete spalling observed, resulting in loss of structural integrity and stiffness.

Originality/value

The structural behaviour of two-way post-tensioned concrete flat slabs at elevated temperatures is less understood compared to their one-way counterparts. Therefore, the present study has focused on the structural behaviour of two-way post-tensioned concrete flat slabs with bonded tendons in fire, a field in which relatively little information on experimental work can be found.

Details

Journal of Structural Fire Engineering, vol. 9 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 11 August 2023

Hanadi Al-Zubaidi and Rabab Allouzi

Cement can be replaced to reduce the energy consumption and the environmental impact of cement. Also, foamed concrete can be used structurally in residential buildings to reduce…

Abstract

Purpose

Cement can be replaced to reduce the energy consumption and the environmental impact of cement. Also, foamed concrete can be used structurally in residential buildings to reduce weight and improve thermal insulation. To achieve these two goals, this paper aims to investigate the effect of basalt powder as a partial replacement of either cement or sand.

Design/methodology/approach

This paper investigates the effect of basalt powder as a partial replacement of either cement or sand on the mechanical properties of foamed concrete used to cast slabs. First, mechanical properties of foamed concrete are tested with and without replacement of basalt. Then, six slabs of different thicknesses and mixes are investigated. The thicknesses considered are 150- and 200-mm slabs. The three mixes used to construct these slabs are foamed concrete with no basalt powder, foamed concrete with replacement of 20% of cement by basalt powder and foamed concrete with replacement of 20% of sand by basalt powder. The flexural behavior of these slabs is investigated.

Findings

All the slabs failed in the commonly intended flexural mode. The results show that the basalt powder acted as a strong filler material in the foamed concrete mix based on mechanical properties and flexural behavior. The proposed foamed concrete slabs can be used structurally in residential buildings.

Originality/value

A natural waste material that can be used to promote energy efficiency and reduce emission is basalt. In this paper, basalt powder is suggested to be used due to its chemical composition that is similar to cement. Also, basalt powder is low in cost as it is waste, while basalt aggregate is prepared, and it is only used as filler in paved roads. Accordingly, basalt is partially used instead of cement to reduce the emission of carbon dioxide that results from the cement manufacturing. Also, it is used as a partial alternative to sand which can be considered as a new stronger source as filling material used in the production of concrete.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 14 March 2016

Ya Wei, Francis T.K. Au, Jing Li and Neil C.M. Tsang

This paper aims to understand the structural fire performance of two-way post-tensioned flat slabs, particularly their deformations and load-carrying mechanisms in fire, and to…

Abstract

Purpose

This paper aims to understand the structural fire performance of two-way post-tensioned flat slabs, particularly their deformations and load-carrying mechanisms in fire, and to explore the behaviour of post-tensioned high-strength self-compacting concrete flat slabs with unbonded tendons in fire.

Design/methodology/approach

Four tests of post-tensioned high-strength self-compacting concrete flat slabs were conducted under fire conditions. Numerical modelling using the commercial package ABAQUS was conducted to help interpret the test results.

Findings

Two of the specimens with lower moisture contents demonstrated excellent fire resistance performance, while the others with slightly higher moisture contents experienced severe concrete spalling.

Originality/value

The test results were discussed in respect of thermal profiles, deflections, crack patterns and concrete spalling. The performance of post-tensioned high-strength self-compacting concrete flat slabs with unbonded tendons under fire conditions was better understood.

Details

Journal of Structural Fire Engineering, vol. 7 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 21 December 2023

Nagat Zalhaf, Mariam Ghazy, Metwali Abdelatty and Mohamed Hamed Zakaria

Even though it is widely used, reinforced concrete (RC) is susceptible to damage from various environmental factors. The hazard of a fire attack is particularly severe because it…

Abstract

Purpose

Even though it is widely used, reinforced concrete (RC) is susceptible to damage from various environmental factors. The hazard of a fire attack is particularly severe because it may cause the whole structure to collapse. Furthermore, repairing and strengthening existing structures with high-performance concrete (HPC) has become essential from both technical and financial points of view. In particular, studying the postfire behavior of HPC with normal strength concrete substrate requires experimental and numerical investigations. Accordingly, this study aims to numerically investigate the post-fire behavior of reinforced composite RC slabs.

Design/methodology/approach

Consequently, in this study, a numerical analysis was carried out to ascertain the flexural behavior of simply supported RC slabs strengthened with HPC and exposed to a particularly high temperature of 600°C for 2 h. This behavior was investigated and analyzed in the presence of a number of parameters, such as HPC types (fiber-reinforced, 0.5% steel, polypropylene fibers [PPF], hybrid fibers), strengthening side (tension or compression), strengthening layer thickness, slab thickness, boundary conditions, reinforcement ratio and yield strength of reinforcement.

Findings

The results showed that traction-separation and full-bond models can achieve accuracy compared with experimental results. Also, the fiber type significantly affects the postfire performance of RC slab strengthened with HPC, where the inclusion of hybrid fiber recorded the highest ultimate load. While adding PPF to HPC showed a rapid decrease in the load-deflection curve after reaching the ultimate load.

Originality/value

The proposed model accurately predicted the thermomechanical behavior of RC slabs strengthened with HPC after being exposed to the fire regarding load-deflection response, crack pattern and failure mode. Moreover, the considered independent parametric variables significantly affect the composite slabs’ behavior.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 10 of 228