Abstract

Purpose

Using passive techniques like twisted tapes and corrugated surface is an efficient method of heat transfer improvement, since the referred manners break the boundary layer and improve the heat exchange. This paper aims to present an improved dual-flow parabolic trough collector (PTC). For this purpose, the effect of an absorber roof, a type of turbulator and a grooved absorber tube in the presence of nanofluid is investigated separately and simultaneously.

Design/methodology/approach

The FLUENT was used for solution of governing equation using control volume scheme. The control volume scheme has been used for solving the governing equations using the finite volume method. The standard k–e turbulence model has been chosen.

Findings

Fluid flow and heat transfer features, as friction factor, performance evaluation criteria (PEC) and Nusselt number have been calculated and analyzed. It is showed that absorber roof intensifies the heat transfer ratio in PTCs. Also, the combination of inserting the turbulator, outer corrugated and inner grooved absorber tube surface can enhance the PEC of PTCs considerably.

Originality/value

Results of the current study show that the PTC with two heat transfer fluids, outer and inner surface corrugated absorber tube, inserting the twisted tape and absorber roof have the maximum Nusselt number ratio equal to 5, and PEC higher than 2.5 between all proposed arrangements for investigated Reynolds numbers (from 10,000 to 20,000) and nanoparticles [Boehmite alumina (“λ-AlOOH)”] volume fractions (from 0.005 to 0.03). Maximum Nusselt number and PEC correspond to nanoparticle volume fraction and Reynolds number equal to 0.03 and 20,000, respectively. Besides, it was found that the performance evaluation criteria index values continuously grow by an intensification of nanoparticle volume concentrations.

Keywords

Citation

Abbasian Arani, A.A. and Memarzadeh, A. (2024), "Nanofluid effect on dual-flow parabolic trough collector performance accompanies with passive technique using experimental data", International Journal of Numerical Methods for Heat & Fluid Flow, Vol. ahead-of-print No. ahead-of-print. https://doi.org/10.1108/HFF-03-2024-0247