To read this content please select one of the options below:

Analysis of iron loss under distorted elliptical rotating flux of SPM motor

N. Takahashi (Department Electrical and Electronic Engineering, Okayama University, Okayama, Japan)
A. Fukum (Department Electrical and Electronic Engineering, Okayama University, Okayama, Japan)
D. Miyagi (Department Electrical and Electronic Engineering, Okayama University, Okayama, Japan)

Abstract

Purpose

In this paper, a new method for estimating iron loss under a distorted elliptical rotating flux is proposed.

Design/methodology/approach

In order to precisely analyze the iron loss of rotating machines, the iron loss under distorted rotating flux should be taken into account. However, reports of precise analysis considering measured iron loss data under rotating flux are few.

Findings

The iron loss of surface permanent magnet (SPM) motor model proposed by the investigation committee of IEE of Japan is estimated using the proposed method. The experimental examination is carried out by measuring the iron loss of the motor using a torque meter.

Originality/value

Examines an estimation method of iron loss of motors.

Keywords

Citation

Takahashi, N., Fukum, A. and Miyagi, D. (2005), "Analysis of iron loss under distorted elliptical rotating flux of SPM motor", COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, Vol. 24 No. 2, pp. 385-395. https://doi.org/10.1108/03321640510586024