Search results

1 – 3 of 3
Article
Publication date: 2 April 2024

Andrew Swan, Anne Schiffer, Peter Skipworth and James Huntingdon

This paper aims to present a literature review of remote monitoring systems for water infrastructure in the Global South.

Abstract

Purpose

This paper aims to present a literature review of remote monitoring systems for water infrastructure in the Global South.

Design/methodology/approach

Following initial scoping searches, further examination was made of key remote monitoring technologies for water infrastructure in the Global South. A standard literature search methodology was adopted to examine these monitoring technologies and their respective deployments. This hierarchical approach prioritised “peer-reviewed” articles, followed by “scholarly” publications, then “credible” information sources and, finally, “other” relevant materials. The first two search phases were conducted using academic search services (e.g. Scopus and Google Scholar). In the third and fourth phases, Web searches were carried out on various stakeholders, including manufacturers, governmental agencies and non-governmental organisations/charities associated with Water, Sanitation and Hygiene (WASH) in the Global South.

Findings

This exercise expands the number of monitoring technologies considered in comparison to earlier review publications. Similarly, preceding reviews have largely focused upon monitoring applications in sub-Saharan Africa (SSA). This paper explores opportunities in other geographical regions and highlights India as a significant potential market for these tools.

Research limitations/implications

This review predominantly focuses upon information/data currently available in the public domain.

Practical implications

Remote monitoring technologies enable the rapid detection of broken water pumps. Broken water infrastructure significantly impacts many vulnerable communities, often leading to the use of less protected water sources and increased exposure to water-related diseases. Further to these public health impacts, there are additional economic disadvantages for these user communities.

Originality/value

This literature review has sought to address some key technological omissions and to widen the geographical scope associated with previous investigations.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 2 May 2024

Xi Liang Chen, Zheng Yu Xie, Zhi Qiang Wang and Yi Wen Sun

The six-axis force/torque sensor based on a Y-type structure has the advantages of simple structure, small space volume, low cost and wide application prospects. To meet the…

Abstract

Purpose

The six-axis force/torque sensor based on a Y-type structure has the advantages of simple structure, small space volume, low cost and wide application prospects. To meet the overall structural stiffness requirements and sensor performance requirements in robot engineering applications, this paper aims to propose a Y-type six-axis force/torque sensor.

Design/methodology/approach

The performance indicators such as each component sensitivities and stiffnesses of the sensor were selected as optimization objectives. The multiobjective optimization equations were established. A multiple quadratic response surface in ANSYS Workbench was modeled by using the central composite design experimental method. The optimal manufacturing structural parameters were obtained by using multiobjective genetic algorithm.

Findings

The sensor was optimized and the simulation results show that the overload resistance of the sensor is 200%F.S., and the axial stiffness, radial stiffness, bending stiffness and torsional stiffness are 14.981 kN/mm, 16.855 kN/mm, 2.0939 kN m/rad and 6.4432 kN m/rad, respectively, which meet the design requirements, and the sensitivities of each component of the optimized sensor have been well increased to be 2.969, 2.762, 4.010, 2.762, 2.653 and 2.760 times as those of the sensor with initial structural parameters. The sensor prototype with optimized parameters was produced. According to the calibration experiment of the sensor, the maximum Class I and II errors and measurement uncertainty of each force/torque component of the sensor are 1.835%F.S., 1.018%F.S. and 1.606%F.S., respectively. All of them are below the required 2%F.S.

Originality/value

Hence, the conclusion can be drawn that the sensor has excellent comprehensive performance and meets the expected practical engineering requirements.

Details

Sensor Review, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 30 April 2024

Abhishek Barwar, Prateek Kala and Rupinder Singh

Some studies have been reported in the past on diaphragmatic hernia (DH) surgery techniques using additive manufacturing (AM) technologies, symptoms of a hernia and post-surgery…

Abstract

Purpose

Some studies have been reported in the past on diaphragmatic hernia (DH) surgery techniques using additive manufacturing (AM) technologies, symptoms of a hernia and post-surgery complications. But hitherto little has been reported on bibliographic analysis (BA) for health monitoring of bovine post-DH surgery for long-term management. Based on BA, this study aims to explore the sensor fabrication integrated with innovative AM technologies for health monitoring assistance of bovines post-DH surgery.

Design/methodology/approach

A BA based on the data extracted through the Web of Science database was performed using bibliometric tools (R-Studio and Biblioshiny).

Findings

After going through the BA and a case study, this review provides information on various 3D-printed meshes used over the sutured site and available Internet of Things-based solutions to prevent the recurrence of DH.

Originality/value

Research gaps exist for 3D-printed conformal sensors for health monitoring of bovine post-DH surgery.

Details

Rapid Prototyping Journal, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1355-2546

Keywords

Access

Year

Last month (3)

Content type

Earlycite article (3)
1 – 3 of 3