Search results

1 – 10 of over 1000
Article
Publication date: 12 April 2022

Jingbo Zhao, Yan Tao and Zhiming Sun

This paper aims to clarify voltage sourced converter’s (VSC’s) influence rules on the alternating current (AC) short-circuit current and identify the key factors, so as to propose…

131

Abstract

Purpose

This paper aims to clarify voltage sourced converter’s (VSC’s) influence rules on the alternating current (AC) short-circuit current and identify the key factors, so as to propose the short-circuit current suppression strategy.

Design/methodology/approach

This paper investigates the key factors which impact the short-circuit current supplied by the VSC based on the equivalent current source model. This study shows that the phase of the VSC equivalent current source is mainly affected by the type of fault, whereas the amplitude is mainly decided by the control mode, the amplitude limiter and the electrical distance. Based on the above influence mechanism, the dynamic limiter with short-circuit current limiting function is designed. The theoretical analysis is verified by simulations on PSCAD.

Findings

The short-circuit current feeding from VSC is closely related to the control mode and control parameters of the VSC, fault type at AC side and the electrical distance of the fault point. The proposed dynamic limiter can make VSC absorb more reactive power to suppress the short-circuit current.

Research limitations/implications

The dynamic limiter proposed in this paper is limited to suppress three-phase short-circuit fault current. The future work will focus more on improving and extending the dynamic limiter to the fault current suppression application in other fault scenarios.

Practical implications

The research results provide a reference for the design of protection system.

Originality/value

The key influence factors are conducive to put forward the measures to suppress the fault current, eliminate the risk of short-circuit current exceeding the standard and reduce the difficulty of protection design.

Details

Circuit World, vol. 49 no. 4
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 19 May 2022

Merlin Sajini M.L., Suja S. and Merlin Gilbert Raj S.

The purpose of the study is distributed generation planning in a radial delivery framework to identify an appropriate location with a suitable rating of DG units energized by…

Abstract

Purpose

The purpose of the study is distributed generation planning in a radial delivery framework to identify an appropriate location with a suitable rating of DG units energized by renewable energy resources to scale back the power loss and to recover the voltage levels. Though several algorithms have already been proposed through the target of power loss reduction and voltage stability enhancement, further optimization of the objectives is improved by using a combination of heuristic algorithms like DE and particle swarm optimization (PSO).

Design/methodology/approach

The identification of the candidate buses for the location of DG units and optimal rating of DG units is found by a combined differential evolution (DE) and PSO algorithm. In the combined strategy of DE and PSO, the key merits of both algorithms are combined. The DE algorithm prevents the individuals from getting trapped into the local optimum, thereby providing efficient global optimization. At the same time, PSO provides a fast convergence rate by providing the best particle among the entire iteration to obtain the best fitness value.

Findings

The proposed DE-PSO takes advantage of the global optimization of DE and the convergence rate of PSO. The different case studies of multiple DG types are carried out for the suggested procedure for the 33- and 69-bus radial delivery frameworks and a real 16-bus distribution substation in Tamil Nadu to show the effectiveness of the proposed methodology and distribution system performance. From the obtained results, there is a substantial decrease in the power loss and an improvement of voltage levels across all the buses of the system, thereby maintaining the distribution system within the framework of system operation and safety constraints.

Originality/value

A comparison of an equivalent system with the DE, PSO algorithm when used separately and other algorithms available in literature shows that the proposed method results in an improved performance in terms of the convergence rate and objective function values. Finally, an economic benefit analysis is performed if a photo-voltaic based DG unit is allocated in the considered test systems.

Article
Publication date: 30 March 2022

Karthick R., Ramakrishnan C. and Sridhar S.

This paper aims to introduce the quasi impedance source inverter (qZSI)-based static compensator (STATCOM), which is incorporated into the hybrid distributed power generation…

Abstract

Purpose

This paper aims to introduce the quasi impedance source inverter (qZSI)-based static compensator (STATCOM), which is incorporated into the hybrid distributed power generation system for enhancement of power quality. The distributed power generation system includes the photovoltaic (PV), wind energy conversion system (WECS) and battery energy storage system.

Design/methodology/approach

The WECS is used by the self-excited induction generator (SEIG) and the flywheel energy storage system (FESS). To regulate its terminal voltage and frequency, the SEIG requires adjustable volt-ampere reactive (VAR). A combination of a STATCOM and a fixed condenser bank usually serves to satisfy the VAR demand. The maximum correntropy criterion-based adaptive filter technique (AFT) is proposed to control the qZSI-STATCOM and to guarantee that the voltage at the SEIG terminal is harmonic-free while providing non-linear three-phase and single-phase loads.

Findings

The coordinated operation of the suggested voltage control and flywheel control systems ensures that load voltage and frequency are retained in their respective values at very low harmonic distortions regardless of wind speed and load variation. The simulation and experimental studies are carried out under different load conditions to validate the efficiencies of the PV-assisted STATCOM.

Originality/value

To improve system stability and minimize total costs, extra load current sensors can also be avoided. This paper proposes to control the SEIG terminal voltage and harmonic elimination in the standalone WECS systems using maximum correntropy criterion-based AFT with a fuzzy logic controller.

Article
Publication date: 3 April 2023

Sebi Neelamkavil Pappachan

This study aims to intend and implement the optimal power flow, where tuning the production cost is done with the inclusion of stochastic wind power and different kinds of…

Abstract

Purpose

This study aims to intend and implement the optimal power flow, where tuning the production cost is done with the inclusion of stochastic wind power and different kinds of flexible AC transmission systems (FACTS) devices. Here, the speed with fitness-based krill herd algorithm (SF-KHA) is adopted for deciding the FACTS devices’ optimal sizing and placement integrated with wind power. Here, the modified SF-KHA optimizes the sizing and location of FACTS devices for attaining the minimum average production cost and real power depletions of the system. Especially, the objective includes reserve cost for overestimation, cost of thermal generation of the wind power, direct cost of scheduled wind power and penalty cost for underestimation. The efficiency of the offered method over several popular optimization algorithms has been done, and the comparison over different algorithms establishes proposed KHA algorithm attains the accurate optimal efficiency for all other algorithms.

Design/methodology/approach

The proposed FACTS devices-based power system with the integration of wind generators is based on the accurate placement and sizing of FACTS devices for decreasing the actual power loss and total production cost of the power system.

Findings

Through the cost function evaluation of the offered SF-KHA, it was noted that the proposed SF-KHA-based power system had secured 13.04% superior to success history-based adaptive differential evolution, 9.09% enhanced than differential evolution, 11.5% better than artificial bee colony algorithm, 15.2% superior to particle swarm optimization and 9.09% improved than flower pollination algorithm.

Originality/value

The proposed power system with the accurate placement and sizing of FACTS devices and wind generator using the suggested SF-KHA was effective when compared with the conventional algorithm-based power systems.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Open Access
Article
Publication date: 28 February 2023

Mohammed Jawad Abed and Anis Mhalla

The paper aims to present a grid-connected multi-inverter for solar photovoltaic (PV) systems to enhance reliability indices after selected the placement and level of PV solar.

Abstract

Purpose

The paper aims to present a grid-connected multi-inverter for solar photovoltaic (PV) systems to enhance reliability indices after selected the placement and level of PV solar.

Design/methodology/approach

In this study, the associated probability is calculated based on the solar power generation capacity levels and outages conditions. Then, based on this probability, dependability indices like average energy not supplied (AENS), expected energy not supplied and loss of load expectations (LOLE) are computed, also, another indices have been computed such as (customer average interruption duration index (CAIDI), system average interruption frequency index (SAIFI) and system average interruption duration index (SAIDI)) addressing by affected customers with distribution networks reliability assessment, including PV. On the basis of their dependability indices and active power flow, several PV solar modules installed in several places are analyzed. A mechanism for assessing the performance of the grid's integration of renewable energy sources is also under investigation.

Findings

The findings of this study based on data extracted form a PV power plant connected to the power network system in Diyala, Iraq 132 kV, attempts to identify the system's weakest points in order to improve the system's overall dependability. In addition, enhanced reliability indices are given for measuring solar PV systems performance connected to the grid and reviewed for the benefit of the customers.

Originality/value

The main contributions of this study are two methods for determining the reliability of PV generators taking into consideration the system component failure rates and the power electronic component defect rates in a PV system which depend on the power input and the power loss using electrical transient analysis program (ETAP) program.

Details

Arab Gulf Journal of Scientific Research, vol. 42 no. 1
Type: Research Article
ISSN: 1985-9899

Keywords

Article
Publication date: 28 February 2023

Mingxiao Dai, Xu Peng, Xiao Liang, Xinyu Zhu, Xiaohan Liu, Xijun Liu, Pengcheng Han and Chao Wu

The purpose of this paper is to propose a DC-port voltage balance strategy realizing it by logic combination modulation (LCM). This voltage balance strategy is brief and high…

Abstract

Purpose

The purpose of this paper is to propose a DC-port voltage balance strategy realizing it by logic combination modulation (LCM). This voltage balance strategy is brief and high efficient, which can be used in many power electronic devices adopting the cascaded H-bridge rectifier (CHBR) such as power electronic transformer (PET).

Design/methodology/approach

The CHBR is typically as a core component in the power electronic devices to implement the voltage or current conversion. The modulation method presented here is aiming to solve the voltage imbalance problem occurred in the CHBR with more stable work station and higher reliability in ordinary operating conditions. In particular, by changing the switch states smoothly and quickly, the DC-port voltage can be controlled as the ideal value even one of the modules in CHBR is facing the load-removed problem.

Findings

By using the voltage balance strategy of LCM, the problem of voltage imbalance occurring in three-phase cascaded rectifiers has been solved properly. With the lower modulation depth, the efficiency of the strategy is shown to be better and stronger. The strategy can work reliably and quickly no matter facing the problem as load-removed change or the ordinary operating conditions.

Research limitations/implications

The limitation of the proposed DC-port voltage balance strategy is calculated and proved, in a three-module CHBR, the LCM could balance the DC-port voltage while one module facing the load-removed situation under 0.83 modulation depth.

Originality/value

This paper provides a useful and particular voltage balance strategy which can be used in the topology of three-phase cascaded rectifier. The value of the strategy is that a brief and reliable voltage balance method in the power electronic devices can be achieved. What is more, facing the problem, such as load-removed, in outport, the strategy can response quickly with no switch jump and switch frequency rising.

Details

Microelectronics International, vol. 40 no. 3
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 4 March 2024

Zeyu Xing, Tachia Chin, Jing Huang, Mirko Perano and Valerio Temperini

The ongoing paradigm shift in the energy sector holds paramount implications for the realization of the sustainable development goals, encompassing critical domains such as…

Abstract

Purpose

The ongoing paradigm shift in the energy sector holds paramount implications for the realization of the sustainable development goals, encompassing critical domains such as resource optimization, environmental stewardship and workforce opportunities. Concurrently, this transformative trajectory within the power sector possesses a dual-edged nature; it may ameliorate certain challenges while accentuating others. In light of the burgeoning research stream on open innovation, this study aims to examine the intricate dynamics of knowledge-based industry-university-research networking, with an overarching objective to elucidate and calibrate the equilibrium of ambidextrous innovation within power systems.

Design/methodology/approach

The authors scrutinize the role of different innovation organizations in three innovation models: ambidextrous, exploitative and exploratory, and use a multiobjective decision analysis method-entropy weight TOPSIS. The research was conducted within the sphere of the power industry, and the authors mined data from the widely used PatSnap database.

Findings

Results show that the breadth of knowledge search and the strength of an organization’s direct relationships are crucial for ambidextrous innovation, with research institutions having the highest impact. In contrast, for exploitative innovation, depth of knowledge search, the number of R&D patents and the number of innovative products are paramount, with universities playing the most significant role. For exploratory innovation, the depth of knowledge search and the quality of two-mode network relations are vital, with research institutions yielding the best effect. Regional analysis reveals Beijing as the primary hub for ambidextrous and exploratory innovation organizations, while Jiangsu leads for exploitative innovation.

Practical implications

The study offers valuable implications to cope with the dynamic state of ambidextrous innovation performance of the entire power system. In light of the findings, the dynamic state of ambidextrous innovation performance within the power system can be adeptly managed. By emphasizing a balance between exploratory and exploitative strategies, stakeholders are better positioned to respond to evolving challenges and opportunities. Thus, the study offers pivotal guidance to ensure sustained adaptability and growth in the power sector’s innovation landscape.

Originality/value

The primary originality is to extend and refine the theoretical understanding of ambidextrous innovation within power systems. By integrating several theoretical frameworks, including social network theory, knowledge-based theory and resource-based theory, the authors enrich the theoretical landscape of power system ambidextrous innovation. Also, this inclusive examination of two-mode network structures, including the interplay between knowledge and cooperation networks, unveils the intricate interdependencies between these networks and the ambidextrous innovation of power systems. This approach significantly widens the theoretical parameters of innovation network research.

Details

Journal of Knowledge Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1367-3270

Keywords

Article
Publication date: 24 August 2023

Marko A. Dimitrijević and Milutin Petronijević

This paper aims to propose a new approach to testing distributed energy resources (DERs) in compliance with the IEEE 1547-2018 standard and describes a new, integrated testing and…

Abstract

Purpose

This paper aims to propose a new approach to testing distributed energy resources (DERs) in compliance with the IEEE 1547-2018 standard and describes a new, integrated testing and validation system.

Design/methodology/approach

The system is built on the virtual instrumentation paradigm, using acquisition modules to measure physical quantities, while signal processing, including intensive calculations of required parameters, data processing, manipulation and reporting are performed on a computing device.

Findings

Intensive laboratory measurements were performed on a laboratory prototype of a microgrid that emulates DERs. The results obtained using the system described were compared with the measurements obtained by the reference instruments. As all the results match, the usability of the system was verified.

Practical implications

This approach to the realization of the testing and validation system has obvious advantages compared to the classical instruments and provides significant flexibility in multiple aspects. First, the system described integrates all the functions of different instruments into one measuring system, making the entire testing and validation process significantly cheaper and faster. Second, the implementation of the system is possible on different computing platforms depending on specific needs. Third, the software implementation of the system functions enables simple upgrading and the introduction of new functions or changes to existing ones according to changes in the standard. Finally, the system described is designed to automatically provide reports on compliance with the standard.

Originality/value

This paper emphasizes the advantages of the proposed approach over classical testing. The value of the paper is reflected in the applicability and practical implications of the proposed and described hardware and software technical solutions.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 5
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 26 December 2023

Mukul Anand, Debashis Chatterjee and Swapan Kumar Goswami

The purpose of this study is to obtain the optimal frequency for low-frequency transmission lines while minimizing losses and maintaining the voltage stability of low-frequency…

Abstract

Purpose

The purpose of this study is to obtain the optimal frequency for low-frequency transmission lines while minimizing losses and maintaining the voltage stability of low-frequency systems. This study also emphasizes a reduction in calculations based on mathematical approaches.

Design/methodology/approach

Telegrapher’s method has been used to reduce large calculations in low-frequency high-voltage alternating current (LF-HVac) lines. The static compensator (STATCOM) has been used to maintain voltage stability. For optimal frequency selection, a modified Jaya algorithm (MJAYA) for optimal load flow analysis was implemented.

Findings

The MJAYA algorithm performed better than other conventional algorithms and determined the optimum frequency selection while minimizing losses. Voltage stability was also achieved with the proposed optimal load flow (OLF), and statistical analysis showed that the proposed OLF reduces the frequency deviation and standard error of the LF-HVac lines.

Originality/value

The optimal frequency for LF-HVac lines has been achieved, Telegrapher’s method has been used in OLF, and STATCOM has been used in LF-HVac transmission lines.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 43 no. 1
Type: Research Article
ISSN: 0332-1649

Keywords

Open Access
Article
Publication date: 23 February 2024

Yuliang Du

Auxiliary power system is an indispensable part of the train; the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways, which are…

113

Abstract

Purpose

Auxiliary power system is an indispensable part of the train; the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways, which are either from auxiliary windings of traction transformers or from DC-link voltage of traction converters. Powered by DC-link voltage of traction converters, the auxiliary systems were maintained of uninterruptable power supply with energy from electric braking. Meanwhile, powered by traction transformers, the auxiliary systems were always out of power while passing the neutral section of power supply grid and control system is powered by battery at this time.

Design/methodology/approach

Uninterrupted power supply of auxiliary power system powered by auxiliary winding of traction transformer was studied. Failure reasons why previous solutions cannot be realized are analyzed. An uninterruptable power supply scheme for the auxiliary systems powered by auxiliary windings of traction transformers is proposed in this paper. The validity of the proposed scheme is verified by simulation and experimental results and on-site operation of an upgraded HXD3C type locomotive. This scheme is attractive for upgrading practical locomotives with the auxiliary systems powered by auxiliary windings of traction transformers.

Findings

This scheme regenerates braking power supplied to auxiliary windings of traction transformers while a locomotive runs in the neutral section of the power supply grid. Control objectives of uninterrupted power supply technology are proposed, which are no overvoltage, no overcurrent and uninterrupted power supply.

Originality/value

The control strategies of the scheme ensure both overvoltage free and inrush current free when a locomotive enters or leaves the neutral section. Furthermore, this scheme is cost low by employing updated control strategy of software and add both the two current sensors and two connection wires of hardware.

Details

Railway Sciences, vol. 3 no. 2
Type: Research Article
ISSN: 2755-0907

Keywords

1 – 10 of over 1000