Search results

1 – 5 of 5
Article
Publication date: 5 August 2014

Mohammad Esmaeili, Nathanaël Jarrassé, Wayne Dailey, Etienne Burdet and Domenico Campolo

The purpose of this paper is to propose a method to avoid hyperstaticity and eventually reduce the magnitude of undesired force/torques. The authors also study the influence of…

331

Abstract

Purpose

The purpose of this paper is to propose a method to avoid hyperstaticity and eventually reduce the magnitude of undesired force/torques. The authors also study the influence of hyperstaticity on human motor control during a redundant task.

Design/methodology/approach

Increasing the level of transparency of robotic interfaces is critical to haptic investigations and applications. This issue is particularly important to robotic structures that mimic the human counterpart's morphology and attach directly to the limb. Problems arise for complex joints such as the wrist, which cannot be accurately matched with a traditional mechanical joint. In such cases, mechanical differences between human and robotic joint cause hyperstaticity (i.e. over-constrained) which, coupled with kinematic misalignment, leads to uncontrolled force/torque at the joint. This paper focusses on the prono-supination (PS) degree of freedom of the forearm. The overall force and torque in the wrist PS rotation is quantified by means of a wrist robot.

Findings

A practical solution to avoid hyperstaticity and reduce the level of undesired force/torque in the wrist is presented. This technique is shown to reduce 75 percent of the force and 68 percent of the torque. It is also shown an over-constrained mechanism could alter human motor strategies.

Practical implications

The presented solution could be taken into account in the early phase of design of robots. It could also be applied to modify the fixation points of commercial robots in order to reduce the magnitude of reaction forces and avoid changes in motor strategy during the robotic therapy.

Originality/value

In this paper for the first time the authors study the effect of hyperstaticity on both reaction forces and human motor strategies.

Details

International Journal of Intelligent Computing and Cybernetics, vol. 7 no. 3
Type: Research Article
ISSN: 1756-378X

Keywords

Article
Publication date: 26 September 2019

Leiyu Zhang, Jianfeng Li, Shuting Ji, Peng Su, Chunjing Tao and Run Ji

Upper-limb joint kinematics are highly complex and the kinematics of rehabilitation exoskeletons fail to reproduce them, resulting in hyperstaticity and human–machine…

Abstract

Purpose

Upper-limb joint kinematics are highly complex and the kinematics of rehabilitation exoskeletons fail to reproduce them, resulting in hyperstaticity and human–machine incompatibility. The purpose of this paper is to design and develop a compatible exoskeleton robot (Co-Exos II) to address these problems.

Design/methodology/approach

The configuration synthesis of Co-Exos II is completed using advanced mechanism theory. A compatible configuration is selected and four passive joints are introduced into the connecting interfaces based on optimal configuration principles. A Co-Exos II prototype with nine degrees of freedom (DOFs) is developed and still owns a compact structure and volume. A new approach is presented to compensate the vertical glenohumeral (GH) movements. Co-Exos II and the upper arm are simplified as a guide-bar mechanism at the elevating plane. The theoretical displacements of passive joints are calculated by the kinematic model of the shoulder loop. The compatible experiments are completed to measure the kinematics of passive joints.

Findings

The compatible configuration of the passive joints can effectively reduce the gravity influences of the exoskeleton device and the upper extremities. The passive joints exhibit excellent compensation effect for the GH joint movements by comparing the theoretical and measured results. Passive joints can compensate for most GH movements, especially vertical movements.

Originality/value

Co-Exos II possesses good human–machine compatibility and wearable comfort for the affected upper limbs. The proposed compensation method is convenient to therapists and stroke patients during the rehabilitation trainings.

Content available
Article
Publication date: 5 August 2014

Dr Guilherme N. DeSouza

103

Abstract

Details

International Journal of Intelligent Computing and Cybernetics, vol. 7 no. 3
Type: Research Article
ISSN: 1756-378X

Article
Publication date: 25 August 2021

Qiang Cao, Jianfeng Li and Mingjie Dong

The purpose of this paper is to evaluate three categories of four-degrees of freedom (4-DOFs) upper limb rehabilitation exoskeleton mechanisms from the perspective of relative…

Abstract

Purpose

The purpose of this paper is to evaluate three categories of four-degrees of freedom (4-DOFs) upper limb rehabilitation exoskeleton mechanisms from the perspective of relative movement offsets between the upper limb and the exoskeleton, so as to provide reference for the selection of exoskeleton mechanism configurations.

Design/methodology/approach

According to the configuration synthesis and optimum principles of 4-DOFs upper limb exoskeleton mechanisms, three categories of exoskeletons compatible with upper limb were proposed. From the perspective of human exoskeleton closed chain, through reasonable decomposition and kinematic characteristics analysis of passive connective joints, the kinematic equations of three categories exoskeletons were established and inverse position solution method were addressed. Subsequently, three indexes, which can represent the relative movement offsets of human–exoskeleton were defined.

Findings

Based on the presented position solution and evaluation indexes, the joint displacements and relative movement offsets of the three exoskeletons during eating movement were compared, on which the kinematic characteristics were investigated. The results indicated that the second category of exoskeleton was more suitable for upper limb rehabilitation than the other two categories.

Originality/value

This paper has a certain reference value for the selection of the 4-DOFs upper extremity rehabilitation exoskeleton mechanism configurations. The selected exoskeleton can ensure the safety and comfort of stroke patients with upper limb dyskinesia during rehabilitation training.

Details

Industrial Robot: the international journal of robotics research and application, vol. 49 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 1 August 1997

A. Cherki, T. Tison, T.M. Guerra and P. Level

Considers the problem of structures’ sensitivities to prescribed displacements uncertainties through the use of fuzzy numbers. Important properties of fuzzy subsets have been…

243

Abstract

Considers the problem of structures’ sensitivities to prescribed displacements uncertainties through the use of fuzzy numbers. Important properties of fuzzy subsets have been studied and used to model uncertainties, and to solve the fuzzy linear system resulting from taking into account the uncertainties on prescribed displacements. Develops a computer program to allow comparisons between several structural designs checking common specifications. Demonstrates the effectiveness of the present method for a cantilever structure modelled in the case of a static finite element analysis.

Details

Engineering Computations, vol. 14 no. 5
Type: Research Article
ISSN: 0264-4401

Keywords

1 – 5 of 5