Search results

1 – 6 of 6
Article
Publication date: 26 July 2024

Rafiu King Raji, Ning Li, Guiqiang Diao, Qin Luo and Hai Jin Liu

The purpose of this research is to ascertain the feasibility of fabricating polymer optical fibers (POFs) based textile structures by knitting with Polymethylmethacrylate (PMMA…

Abstract

Purpose

The purpose of this research is to ascertain the feasibility of fabricating polymer optical fibers (POFs) based textile structures by knitting with Polymethylmethacrylate (PMMA) based optical fibers for textile sensor application. It has long been established that by using the principles of physics, POFs have the capability to function as sensors, detecting strain, temperature and other variables. However, POF applications such as strain and pressure sensing using knitting techniques has since not been very successful due to a number of reasons. Commercially available PMMA-based optical fibers tend to be fragile and susceptible to breakages when subjected to stress during the knitting processes. Also light transmitted within these fibers is prone to leakage due to the curvature that results when optical fibers are interlaced or interlooped within fabric structures.

Design/methodology/approach

Using Stoll’s multi-gauge CMS 350 HP knitting machine, five fabric structures namely, 1 × 4 float knit structure, tunnel inlay knit structure, 3:1 fleece fabric and 2:1 fleece fabric structure respectively were used to knit sensor samples. The samples were subsequently tested for length of illumination and sensitivity relative to applied pressure.

Findings

The results of this preliminary study establish that embedding plastic optical fibers into a knitted structure during the fabric formation process for soft strain sensor application possible. The best illumination performance was recorded for tunnel inlay structure which had an average of 94 cm course length of POF being illuminated. Sensor sensitivity experiments also establish that the relative spectral intensity of the fiber is sensitive to both light and pressure. Problems encountered and recommendations for further research have also been discussed and proffered.

Research limitations/implications

Due to resource limitations, an innovative technique (use of precision weight set) was used to apply pressure to the sensors. Consequently, information regarding the extent of corresponding sensor deformation has not been used in this initial analysis.

Practical implications

Because the fundamental step toward finding a solution to any engineering problem is the acquisition of reliable data, and considering the fact that most of the popular technologies used for soft textile sensors are still bedeviled with the problem of signal instability and noise, the success of this application thus has the tendency to promote the wide spread adoption of POF sensors for smart apparel applications.

Originality/value

As far as research on soft strain sensors is concerned, to the best of the authors’ knowledge, this is the first study to have attempted to knit deformable sensors using commercially available POFs.

Details

Sensor Review, vol. 44 no. 5
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 16 September 2024

Weiwei Yue, Yuwei Cao, Shuqi Xie, Kang Ning Cheng, Yue Ding, Cong Liu, Yan Jing Ding, Xiaofeng Zhu, Huanqing Liu and Muhammad Shafi

This study aims to improve detection efficiency of fluorescence biosensor or a graphene field-effect transistor biosensor. Graphene field-effect transistor biosensing and…

Abstract

Purpose

This study aims to improve detection efficiency of fluorescence biosensor or a graphene field-effect transistor biosensor. Graphene field-effect transistor biosensing and fluorescent biosensing were integrated and combined with magnetic nanoparticles to construct a multi-sensor integrated microfluidic biochip for detecting single-stranded DNA. Multi-sensor integrated biochip demonstrated higher detection reliability for a single target and could simultaneously detect different targets.

Design/methodology/approach

In this study, the authors integrated graphene field-effect transistor biosensing and fluorescent biosensing, combined with magnetic nanoparticles, to fabricate a multi-sensor integrated microfluidic biochip for the detection of single-stranded deoxyribonucleic acid (DNA). Graphene films synthesized through chemical vapor deposition were transferred onto a glass substrate featuring two indium tin oxide electrodes, thus establishing conductive channels for the graphene field-effect transistor. Using π-π stacking, 1-pyrenebutanoic acid succinimidyl ester was immobilized onto the graphene film to serve as a medium for anchoring the probe aptamer. The fluorophore-labeled target DNA subsequently underwent hybridization with the probe aptamer, thereby forming a fluorescence detection channel.

Findings

This paper presents a novel approach using three channels of light, electricity and magnetism for the detection of single-stranded DNA, accompanied by the design of a microfluidic detection platform integrating biosensor chips. Remarkably, the detection limit achieved is 10 pm, with an impressively low relative standard deviation of 1.007%.

Originality/value

By detecting target DNA, the photo-electro-magnetic multi-sensor graphene field-effect transistor biosensor not only enhances the reliability and efficiency of detection but also exhibits additional advantages such as compact size, affordability, portability and straightforward automation. Real-time display of detection outcomes on the host facilitates a deeper comprehension of biochemical reaction dynamics. Moreover, besides detecting the same target, the sensor can also identify diverse targets, primarily leveraging the penetrative and noninvasive nature of light.

Details

Sensor Review, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 18 July 2024

Anindya Bose, Sarthak Sengupta and Sayori Biswas

This study aims to provide a microfluidic blood glucose sensing platform based on integrated interdigitated electrode arrays (IDEAs) on a flexible quartz glass substrate, adhering…

Abstract

Purpose

This study aims to provide a microfluidic blood glucose sensing platform based on integrated interdigitated electrode arrays (IDEAs) on a flexible quartz glass substrate, adhering closely to pertinent electrochemical characterizations.

Design/methodology/approach

Sensors are the key elements of the modern electronics era through which all the possible physical quantities can be detected and converted into their equivalent electrical form and processed further. But to make the sensing environment better, various types of innovative architectures are being developed nowadays and among them interdigitated electrodes are quite remarkable in terms of their sensing capability. They are a well-qualified candidate in the field of gas sensing and biosensing, but even their sensitivities are getting saturated due to their physical dimensions. Most of the thin film IDEAs fabricated by conventional optical lithographic techniques do not possess a high surface-to-volume ratio to detect the target specified and that reduces their sensitivity factor. In this context, a classic conductive carbon-based highly sensitive three dimensional (3D) IDEA-enabled biosensing system has been conceived on a transparent and flexible substrate to measure the amount of glucose concentration present in human blood. 3D IDEA possesses a way better capacitive sensing behavior compared to conventional thin film microcapacitive electrodes. To transmit the target biological analyte sample property for the detection purpose to the interdigitated array-based sensing platform, the design of a microfluidic channel is initiated on the same substrate. The complex 3D Inter Digital array structure improves the overall capacitance of the entire sensing platform and the reactive surface area as well. The manufactured integrated device displays a decent value of sensitivity in the order of 5.6 µA mM−1 cm−2.

Findings

Development of a low-cost array-based integrated and highly flexible microfluidic biochip to extract the quantity of glucose present in human blood.

Originality/value

Potential future research opportunities in the realm of integrated miniaturized, low-cost smart biosensing systems may arise from this study.

Details

Sensor Review, vol. 44 no. 5
Type: Research Article
ISSN: 0260-2288

Keywords

Abstract

Details

Intelligence and State Surveillance in Modern Societies
Type: Book
ISBN: 978-1-83549-098-3

Article
Publication date: 17 September 2024

Umabharati Rawat and Ramesh Anbanandam

The cyber-physical system (CPS) is a well proven technology for improving system performance, resilience, and interconnectivity. In emerging nations like India, the logistics…

Abstract

Purpose

The cyber-physical system (CPS) is a well proven technology for improving system performance, resilience, and interconnectivity. In emerging nations like India, the logistics industry lacks practices connecting logistical equipment with cyberspace. This paper aims to bridge this gap by identifying and evaluating the performance metrics of connectivity solutions. Its goal is to establish an appropriate infrastructure that enables seamless connectivity within the CPS-enabled logistics ecosystem.

Design/methodology/approach

A novel integrated decision method is employed to classify the optimal connectivity solution for CPS. It integrates Regret Theory (RT) and Preference Ranking for Organization Method for Enrichment Evaluation (PROMETHEE-1) method in a Hesitant Fuzzy (HF) environment. This method considers the psychological traits of decision-makers and effectively incorporates their hesitancy for the classification.

Findings

The findings highlight security (c10) as the foremost critical performance metric, followed by cost (c6), scalability (c9), traceability (c2) and trustworthiness (c1) to build connective infrastructure for CPS. For extensive coverage scenarios, like freight transportation, cellular connectivity (a2) emerges as the most suitable connectivity solution.

Practical implications

This study provides a roadmap to logistics managers for selecting a suitable connectivity infrastructure to enhance seamless connectivity in logistics operations and processes. Technology providers can utilize the findings to develop the CPS infrastructure for effective freight logistics management.

Originality/value

This research introduces a novel decision-making tool for making choices related to advanced technology assessment. It holds significant value in facilitating well-informed decisions in the digital transformation era.

Details

Benchmarking: An International Journal, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1463-5771

Keywords

Article
Publication date: 15 July 2024

Min Zhao, Wei He, Xiuyu He, Liang Zhang and Hongxue Zhao

Bionic flapping-wing aerial vehicles (FWAVs) mimic natural flyers to generate the lift and thrust, such as birds, bats and insects. As an important component of the FWAVs, the…

Abstract

Purpose

Bionic flapping-wing aerial vehicles (FWAVs) mimic natural flyers to generate the lift and thrust, such as birds, bats and insects. As an important component of the FWAVs, the flapping wings are crucial for the flight performance. The aim of this paper is to study the effects of different wings on aerodynamic performance.

Design/methodology/approach

Inspired by the wings structure of birds, the authors design four cambered wings to analyze the effect of airfoils on the FWAVs aerodynamic performance. The authors design the motor-driven mechanism of flapping wings, and realize the control of flapping frequency. Combined with the wind tunnel equipment, the authors build the FWAVs force test platform to test the static and dynamic aerodynamic performance of different flapping wings under the state variables of flapping frequency, wind speed and inclined angle.

Findings

The results show that the aerodynamic performance of flapping wing with a camber of 20 mm is the best. Compared with flat wing, the average lift can be improved by 59.5%.

Originality/value

Different from the traditional flat wing design of FWAVs, different cambered flapping wings are given in this paper. The influence of airfoils on aerodynamic performance of FWAVs is analyzed and the optimal flapping wing is obtained.

Details

Robotic Intelligence and Automation, vol. 44 no. 5
Type: Research Article
ISSN: 2754-6969

Keywords

1 – 6 of 6