Deanna Craig and M.Z. Naser

The extreme nature of fire makes structural fire engineering unique in that the load actions dictating design are intense and neither geographically nor seasonally bound. Simply…

Abstract

Purpose

The extreme nature of fire makes structural fire engineering unique in that the load actions dictating design are intense and neither geographically nor seasonally bound. Simply, fire can break out anywhere, at any time and for any number of reasons. Despite the apparent need, the fire design of structures still relies on expensive fire tests, complex finite element simulations and outdated procedures with little room for innovation. This paper aims to discuss the aforementioned issues.

Design/methodology/approach

This primer highlights the latest state of the art in this area with regard to performance-based design in fire structural engineering. In addition, this short review also presents a series of examples of successful implementation of performance-based fire design of structures from around the world.

Findings

A comparison between global efforts clearly shows the advances put forth by European and Oceanian efforts as opposed to the rest of the world. In addition, it can be clearly seen that most performance-based fire designs are related to steel and composite structures.

Originality/value

In one study, this paper presents a concise and global view to performance-based fire design of structures from success stories from around the world.

Details

Journal of Structural Fire Engineering, vol. 15 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 6 February 2024

Farshid Rashidiyan, Seyed Rasoul Mirghaderi, Saeed Mohebbi and Sina Kavei

This research study focuses on investigating the seismic performance of non-straight beams in steel structures and exploring the mechanism by which plastic hinges are formed…

Abstract

Purpose

This research study focuses on investigating the seismic performance of non-straight beams in steel structures and exploring the mechanism by which plastic hinges are formed within these beams. The findings contribute to the understanding of their behaviour under seismic loads and offer insights into their potential for enhancing the lateral resistance of the structure. The abstract of the study highlights the significance of corners in structural plans, where non-coaxial columns, diagonal elements or beams deviating from a straight path are commonly observed. Typically, these non-straight beams are connected to the columns using pinned connections, despite their unknown seismic behaviour. Recognizing the importance of generating plastic hinges in special moment resisting frames and the lack of previous research on the involvement of these non-straight beams, this study aims to address this knowledge gap.

Design/methodology/approach

This study examines the seismic behaviour and plastic hinge formation of non-straight beams in steel structures. Non-straight beams are beams that connect non-coaxial columns and diagonal elements, or deviate from a linear path. They are usually pinned to the columns, and their seismic contribution is unknown. A critical case with a 12-m non-straight beam is analysed using Abaqus software. Different models are created with varying cross-section shapes and connection types between the non-straight beams. The models are subjected to lateral monotonic and cyclic loads in one direction. The results show that non-straight beams increase the lateral stiffness, strength and energy dissipation of the models compared to disconnected beams that act as two cantilevers.

Findings

The analysis results reveal several key findings. The inclusion of non-straight beams in the models leads to increased lateral stiffness, strength and energy dissipation compared to the scenario where the beams are disconnected and act as two cantilever beams. Plastic hinges are formed at both ends of the non-straight beam when a 3% drift is reached, contributing to energy damping and introducing plasticity into the structure. These results strongly suggest that non-straight beams play a significant role in enhancing the lateral resistance of the system. Based on the seismic analysis results, this study recommends the utilization of non-straight beams in special moment frames due to the formation of plastic hinges within these beams and their effective participation in resisting lateral seismic loads. This research fills a critical gap in understanding the behaviour of non-straight beams and provides valuable insights for structural engineers involved in the design and analysis of steel structures.

Originality/value

The authors believe that this research will greatly contribute to the knowledge and understanding of the seismic performance of non-straight beams in steel structures.

Article
Publication date: 13 December 2022

Zhenhua Luo, Juntao Guo, Jianqiang Han and Yuhong Wang

Prefabricated technology is gradually being applied to the construction of subway stations due to its characteristic of mechanization. However, the prefabricated subway station in…

Abstract

Purpose

Prefabricated technology is gradually being applied to the construction of subway stations due to its characteristic of mechanization. However, the prefabricated subway station in China is in the initial stage of development, which is prone to construction safety issues. This study aims to evaluate the construction safety risks of prefabricated subway stations in China and formulate corresponding countermeasures to ensure construction safety.

Design/methodology/approach

A construction safety risk evaluation index system for the prefabricated subway station was established through literature research and the Delphi method. Furthermore, based on the structure entropy weight method, matter-element theory and evidence theory, a hybrid evaluation model is developed to evaluate the construction safety risks of prefabricated subway stations. The basic probability assignment (BPA) function is obtained using the matter-element theory, the index weight is calculated using the structure entropy weight method to modify the BPA function and the risk evaluation level is determined using the evidence theory. Finally, the reliability and applicability of the evaluation model are verified with a case study of a prefabricated subway station project in China.

Findings

The results indicate that the level of construction safety risks in the prefabricated subway station project is relatively low. Man risk, machine risk and method risk are the key factors affecting the overall risk of the project. The evaluation results of the first-level indexes are discussed, and targeted countermeasures are proposed. Therefore, management personnel can deeply understand the construction safety risks of prefabricated subway stations.

Originality/value

This research fills the research gap in the field of construction safety risk assessment of prefabricated subway stations. The methods for construction safety risk assessment are summarized to establish a reliable hybrid evaluation model, laying the foundation for future research. Moreover, the construction safety risk evaluation index system for prefabricated subway stations is proposed, which can be adopted to guide construction safety management.

Details

Engineering, Construction and Architectural Management, vol. 31 no. 4
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 26 December 2023

Hiral Patel and Gabriela Zapata-Lancaster

This paper aims to highlight a broader definition of good building performance that goes beyond the traditional emphasis on technical aspects, only adopting the lens of the social…

Abstract

Purpose

This paper aims to highlight a broader definition of good building performance that goes beyond the traditional emphasis on technical aspects, only adopting the lens of the social construction of technology (SCOT) in the empirical space of the workplace sector. Several building performance evaluation (BPE) methods focus on technical aspects such as energy consumption, indoor environmental conditions and compliance with building regulations and standards. Technical aspects, albeit important goals, only embed a partial component of what buildings are expected to deliver. There is growing interest in considering the organisational and experiential expectations of building performance, particularly integrating various views of performance as expected by different user groups.

Design/methodology/approach

The paper adopts an archival research method to analyse the archive of the workplace consultants DEGW, particularly focusing on their work on London’s Broadgate development in the 1980s and the 1990s.

Findings

The findings reveal how voices from a pluralistic client organisation can be addressed to articulate a broad definition of building performance that integrates different viewpoints encompassing technical, organisational and experiential expectations. In DEGW’s work, the views on building performance of various stakeholders involved in the everyday use and management of buildings are identified without imposing predetermined agendas or research notions of performance. Particular emphasis is given to understanding clients as not a homogenous entity but consisting of different interest groups, which implies multiple conceptualisations of building performance and the building itself.

Research limitations/implications

The performance expectations of a building vary between organisations and even within any organisation. Moreover, the needs of an organisation will change over time, and the BPE criteria need to be changed to ensure better alignment between organisations and the physical spaces they occupy. A critical reflection on the conceptualisation of “users” and “building” in BPE methods is required to create an integrated approach towards building performance.

Originality/value

The paper offers insights by adopting the theoretical lens of SCOT to explore an integrated approach to building performance that captures the varied needs of building users through the example of London’s Broadgate development.

Details

Journal of Corporate Real Estate , vol. 26 no. 1
Type: Research Article
ISSN: 1463-001X

Keywords

Article
Publication date: 29 March 2024

Tugrul Oktay and Yüksel Eraslan

The purpose of this paper is to improve autonomous flight performance of a fixed-wing unmanned aerial vehicle (UAV) via simultaneous morphing wingtip and control system design…

Abstract

Purpose

The purpose of this paper is to improve autonomous flight performance of a fixed-wing unmanned aerial vehicle (UAV) via simultaneous morphing wingtip and control system design conducted with optimization, computational fluid dynamics (CFD) and machine learning approaches.

Design/methodology/approach

The main wing of the UAV is redesigned with morphing wingtips capable of dihedral angle alteration by means of folding. Aircraft dynamic model is derived as equations depending only on wingtip dihedral angle via Nonlinear Least Squares regression machine learning algorithm. Data for the regression analyses are obtained by numerical (i.e. CFD) and analytical approaches. Simultaneous perturbation stochastic approximation (SPSA) is incorporated into the design process to determine the optimal wingtip dihedral angle and proportional-integral-derivative (PID) coefficients of the control system that maximizes autonomous flight performance. The performance is defined in terms of trajectory tracking quality parameters of rise time, settling time and overshoot. Obtained optimal design parameters are applied in flight simulations to test both longitudinal and lateral reference trajectory tracking.

Findings

Longitudinal and lateral autonomous flight performances of the UAV are improved by redesigning the main wing with morphing wingtips and simultaneous estimation of PID coefficients and wingtip dihedral angle with SPSA optimization.

Originality/value

This paper originally discusses the simultaneous design of innovative morphing wingtip and UAV flight control system for autonomous flight performance improvement. The proposed simultaneous design idea is conducted with the SPSA optimization and a machine learning algorithm as a novel approach.

Details

Aircraft Engineering and Aerospace Technology, vol. 96 no. 3
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 5 May 2023

Hikmat Ali, Amal Abed and Alaa Rababah

As numerous research studies have investigated the effect of the built environment on human contentment, building regulations have advanced as a direct impact on indoor…

Abstract

Purpose

As numerous research studies have investigated the effect of the built environment on human contentment, building regulations have advanced as a direct impact on indoor environmental quality (IEQ) to include thermal, lighting, air quality and acoustics systems. Yet, while IEQ and residents' satisfaction have been discussed thoroughly in previous research, only a few studies have researched the role of building regulations as motivating factors in the housing context, specifically in Jordan.

Design/methodology/approach

A mixed-method approach was adopted to address this issue involving genotype analysis for building morphology and simulation using Design Builder software. This helped to understand the impact of building regulations variables, including building setback, the height of an adjacent building, orientation and building geometry. Meanwhile, an online survey was conducted to include 410 residents spread out in various building categories (A, B, C and D).

Findings

The results of this study revealed that building regulation of setbacks, the height of adjacent buildings and orientation are significant parameters that directly affect IEQ and residents' satisfaction. In addition, based on this study, the matter was clear that the highest total satisfaction resulted based on the highest comfort level in terms of temperature and daylight obtained due to larger setback and lower building height. Yet, this finding undermined smart growth principles due to the limited scope of building regulation that focused only on spatial and physical dimensions, so improving to include environmental aspects such as passive design strategies that appreciate natural ventilation and lighting is necessary, which positively impact IEQ.

Originality/value

The concept of IEQ and residents' satisfaction have been discussed thoroughly, but only a few studies have researched the role of building regulations as motivating factors in the housing context specifically in Jordan.

Details

Archnet-IJAR: International Journal of Architectural Research, vol. 18 no. 1
Type: Research Article
ISSN: 2631-6862

Keywords

Article
Publication date: 5 June 2023

Takumi Yamaguchi and Fuminobu Ozaki

The main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope…

46

Abstract

Purpose

The main purpose of this study was to evaluate the tensile strengths of JIS G3549 super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections at fire and post fire.

Design/methodology/approach

Steady-state tests from ambient temperature (20 °C) to 800 °C, transient-state tests under the allowable design tensile force and tensile tests in an ambient temperature environment after heating (heating temperatures of 200–800 °C) were conducted.

Findings

The tensile strengths of the wire rope and end-connection specimens at both fire and post fire were obtained. The steel wire rope specimens possessed larger reduction factors than general hot-rolled mild steels (JIS SS400) and high-strength steel bolts (JIS F10T). The end-connection specimens with sufficient socket lengths exhibited ductile fracture of the wire rope part at both fire and post fire; however, those with short socket lengths experienced a pull-out fracture at the socket.

Originality/value

The fundamental and important tensile test results of the super high-strength steel strand wire ropes (1,570 MPa-class high-carbon steels) and wire rope open swaged socket connections were accumulated at fire and post fire, and the fracture modes were clarified. The obtained test results contribute to fire resistance performance-based design of cable steel structures at fire and fire-damage investigations to consider their reusability post fire.

Article
Publication date: 20 January 2023

Sabah Ben Messaoud

The purpose of this paper is to make a contribution to understanding the influence of factors such as the water/cement (W/C) ratio and the granular class on the mechanical and…

Abstract

Purpose

The purpose of this paper is to make a contribution to understanding the influence of factors such as the water/cement (W/C) ratio and the granular class on the mechanical and physical properties of high-strength concretes (HSCs). In the formulations of HSC, aggregates by their high mass and volume proportion play an important role. When selecting aggregates, it is necessary to know their intrinsic properties. These properties influence the performance of concrete, in particular the quality of the granulate cimentary adhesion.

Design/methodology/approach

This experimental study focused on the effect of W/C ratio (0.25, 0.30, 0.35), the effect of replacing a part of cement by silica fume (SF) (8%), the effect of fraction of aggregate on properties of fresh and hardened concrete, the effect of different environment conversation like drinking water and sea water on compressive strength and the study of absorption of water and softening using the mix design method of the University of Sherbrooke combined with the Dreux-Gorisse method which gives good results.

Findings

At the end of our work, the examination of the results obtained made it possible to establish the correlations between the formulations studied and the physicomechanical characteristics of the concrete compositions (HSC25, HSC16, HSC8). The results of this study show that the use of three granular classifications (DMAX8, DMAX16 and DMAX25) and three report W/C (0.25, 0.30 and 0.35) in two different conservation environment (drinking water and sea water) give HSCs, HSC25 with an W/C = 0.25 ratio has reached the largest mechanical strength of 90 MPa for different environments of conservation. For selecting aggregates, it is necessary to know their intrinsic properties, these properties influence the strength of concrete. In general, there is a slight decrease in the compressive resistance of the specimens stored in seawater, it can be said that the conservation life has not had effect on the resistance (28 days). The effect of aggressive environment can appear in the long term.

Research limitations/implications

Mixed design and concrete fabrication with a 28-day compressive strength of up to 68 MPa or more of 90 MPa can now be possible used in Jiel (Algeria), and it should no longer be considered to be used only in an experimental domain. Addition of SF in concrete showed good development of strength between 7 and 28 days, depending on the design of the mix.

Practical implications

Concrete containing 8% SF with W/B of 0.25 has higher compressive strength than the other concretes, and concretes with SF are more resistant than concretes without SF, so it is possible to have concrete with a compressive strength of 82 MPa for W/C 0.25 without SF. Like as a result, we can avoid the use of SF to affect the strength of concrete at compressive strength of 68 MPa, and a slump of 21 cm, because the SF is the most expensive ingredient used in the composition of concrete and is therefore very important economically. One of the main factors of production of HSC above 90 MPa is use of aggregate DMAX25, which is stronger with W/B of 0.25 and 0.30.

Social implications

This mixtures leads to a very dense microstructure and low porosity and produces increased permeability of HSC and is able to resist the penetration of aggressive agents. This combination has a positive effect on the economy of concrete.

Originality/value

The combination of the Dreux-Gorisse method with the Sherbrook method is very beneficial for determining the percentage of aggregates used, and the use of coarse aggregates of Jijel to obtain HSC with 90 MPa and 16 cm of workability.

Details

World Journal of Engineering, vol. 21 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 13 October 2022

Yunis Ali Ahmed, Hafiz Muhammad Faisal Shehzad, Muhammad Mahboob Khurshid, Omayma Husain Abbas Hassan, Samah Abdelsalam Abdalla and Nashat Alrefai

Building information modelling (BIM) has transformed the traditional practices of the Architecture, Engineering and Construction (AEC) industry. BIM creates a collaborative…

Abstract

Purpose

Building information modelling (BIM) has transformed the traditional practices of the Architecture, Engineering and Construction (AEC) industry. BIM creates a collaborative digital representation of built environment data. Competitive advantage can be achieved with collaborative project delivery and rich information modelling. Despite the abundant benefits, BIM’s adoption in the AEC is susceptible to confrontation. A substantial impediment to BIM adoption often cited is data interoperability. Other facets of interoperability got limited attention. Other academic areas, including information systems, discuss the interoperability construct ahead of data interoperability. These interoperability factors have yet to be surveyed in the AEC industry. This study aims to investigate the effect of interoperability factors on BIM adoption and develop a comprehensive BIM adoption model.

Design/methodology/approach

The theoretical foundations of the proposed model are based on the European interoperability framework (EIF) and technology, organization, environment framework (TOE). Quantitative data collection from construction firms is gathered. The model has been thoroughly examined and validated using partial least squares structural equation modelling in SmartPLS software.

Findings

The study’s findings indicate that relative advantage, top management support, government support, organizational readiness and regulation support are determinants of BIM adoption. Financial constraints, complexity, lack of technical interoperability, semantic interoperability, organizational interoperability and uncertainty are barriers to BIM adoption. However, compatibility, competitive pressure and legal interoperability do not affect BIM adoption.

Practical implications

Finally, this study provides recommendations containing the essential technological, organizational, environmental and interoperability factors that AEC stakeholders can address to enhance BIM adoption.

Originality/value

To the best of the authors’ knowledge, this paper is one of the first studies to combine TOE and EIF in a single research model. This research provides empirical evidence for using the proposed model as a guide to promoting BIM adoption. As a result, the highlighted determinants can assist organizations in developing and executing successful policies that support BIM adoption in the AEC industry.

Details

Construction Innovation , vol. 24 no. 2
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 29 December 2023

Jyoti Ranjan Mohapatra and Manoj Kumar Moharana

This study aims to investigate a new circuitous minichannel cold plate (MCP) design involving flow fragmentation. The overall thermal performance and the temperature uniformity…

Abstract

Purpose

This study aims to investigate a new circuitous minichannel cold plate (MCP) design involving flow fragmentation. The overall thermal performance and the temperature uniformity analysis are performed and compared with the traditional serpentine design. The substrate thickness and its thermal conductivity are varied to analyse the effect of axial-back conduction due to the conjugate nature of heat transfer.

Design/methodology/approach

The traditional serpentine minichannel is modified into five new fragmented designs with two inlets and two outlets. A three-dimensional numerical model involving the effect of conjugate heat transfer with a single-phase laminar fluid flow subjected to constant heat flux is solved using a finite volume-based computational fluid dynamics solver.

Findings

The minimum and maximum temperature differences are observed for the two branch fragmented flow designs. The two-branch and middle channel fragmented design shows better temperature uniformity over other designs while the three-branch fragmented designs exhibited better hydrodynamic performance.

Practical implications

MCPs could be used as an indirect liquid cooling method for battery thermal management of pouch and prismatic cells. Coupling the modified cold plates with a battery module and investigating the effect of different battery parameters and environmental effects in a transient state are the prospects for further research.

Originality/value

The study involves several aspects of evaluation for a conclusive decision on optimum channel design by analysing the performance plot between the temperature uniformity index, average base temperature and overall thermal performance. The new fragmented channels are designed in a way to facilitate the fluid towards the outlet in the minimum possible path thereby reducing the pressure drop, also maximizing the heat transfer and temperature uniformity from the substrate due to two inlets and a reversed-flow pattern. Simplified minichannel designs are proposed in this study for practical deployment and ease of manufacturability.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 34 no. 3
Type: Research Article
ISSN: 0961-5539

Keywords

Access

Year

Last 3 months (4291)

Content type

Article (4291)